957 resultados para AXIAL DIVERGENCE


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider an extension of the axial model where local gauge symmetries are taken into account. The result is a mixing of the axial and Schwinger models. The anomaly of the axial current is calculated by means of the Fujikawa path integral technique and the model is also solved. Besides the well-known features of the particular models (axial and Schwinger) an effective interaction of scalar and gauge fields via a topological current is obtained. This term is responsible for the appearance of massive poles in the propagators that are different from those of both models.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work we consider the two-point Green's functions in (1 + 1)-dimensional quantum electrodynamics and show that the correct implementation of analytic regularization gives a gauge invariant result for the vacuum polarization amplitude and the correct coefficient for the axial anomaly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We analyze double Higgs boson production at the Large Hadron Collider in the context of Little Higgs models. In double Higgs production, the diagrams involved are directly related to those that cause the cancellation of the quadratic divergence of the Higgs self-energy, providing a robust prediction for this class of models. We find that in extensions of this model with the inclusion of a so-called T-parity, there is a significant enhancement in the cross sections as compared to the Standard Model. © SISSA 2006.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The genetic divergence in 20 Eucalyptus spp. clones was evaluated by multivariate techniques based on 167 RAPD markers, of which 155 were polymorphic and 12 monomorphic. The measures of genetic distances were obtained by the arithmetic complement of the coefficients of Jaccard and of Sorenso-Nei and Li and evaluated by the hierarchical methods of Single Linkage clustering and Unweighted Pair Group Method with Arithmetic Mean (UPGMA). Independent of the dissimilarity coefficient, the greatest divergence was found between clones 7 and 17 and the smallest between the clones 11 and 14. Clone clustering was little influenced by the applied procedure so that, adopting the same percentage of divergence, the UPGMA identified two groups less for the coefficient of Sorenso-Nei and Li. The clones evidenced considerable genetic divergence, which is partly associated to the origin of the study material. The clusters formed by the UPGMA clustering algorithm associated to the arithmetic complement of Jaccard were most consistent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The evaluation of diversity in germplasm collections is important for both plant breeders and germplasm curators to optimize the use of the variability available. Diversity can be estimated by different genetic markers. The purpose of this study was to estimate the genetic divergence of 30 morphological and agronomic traits in 108 sesame genotypes by multivariate analysis. The Cole-Rodgers index was used to establish the dissimilarity matrices. The principal component analysis identified the traits that contributed most to the divergence and the genotypes were clustered by Tocher's optimization. Despite the narrow genetic basis, the markers were efficient to characterize the genotypes and identify the most similar groups or duplicate and divergent genotypes. Greatest variation was found for the traits number of capsules per plant and grain yield.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The correct radiographic identification of ossification of the pterygospinous and pterygoalar ligaments plays an important role in surgical procedures for the treatment of trigeminal neuralgia. Most of these procedures are performed through the foramen ovale, a site where these ligaments can be found to be partially or completely ossified. We studied the radiographic features of these ossified ligaments and their location in relation to the foramen ovale by the Hirtz axial technique. For this purpose, 93 dry skulls from the Discipline of Anatomy, São José dos Campos Dental School, UNESP, which presented partial or complete ossification of these ligaments, were radiographed. The pterygospinous ligament was detected on 27.97% of radiographs and was partially ossified in 19.36% of cases and completely ossified in 8.61%. The pterygoalar ligament was present in 62.35% of radiographs, being partially ossified in 49.44% and completely ossified in 12.91%. The pterygospinous ligaments was found to be partially and completely ossified on the same radiograph in 3.23% of cases, whereas the pterygoalar ligament appeared partially and completely ossified on the same radiograph in 6.45%. Furthermore, the pterygospinous ligament was thinner than the pterygoalar ligament and located more medially in relation to the foramen ovale. The pterygoalar ligament formed a large bone bar lateral to the foramen ovale, often obliterating the lumen of the latter. The Hirtz axial technique is an excellent tool for the observation of complete or partial ossification of the pterygospinous and pterygoalar ligaments in surgical procedures for the treatment of trigeminal neuralgia performed through the foramen ovale.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Includes Bibliography

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Considering that the cutaneous flap can be affected by isquemic complications the extra corporeal shock wave therapy (ESWT) was described as rescue techniques. The present study was developed to analyze histological and with morfometry, twenty one skin samples treated or not with the shock wave therapy, obtained from flap's distal border, used in this study to repair eyelids' experimental defects in dogs. The flap with or without ESWT did not show any histological sign of inflammatory or atrophic alterations. Both group treated showed similar morphometrical characteristics. The ESWT with the protocol used in this study (2500 impulses at 0,15 mJ/mm 2) did not demonstrate significant clinical outcomes as a rescue technique when applied over the oris angularis flap, however results showed no signals of collateral deleterious effects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The present study used strain gauge analysis to perform an in vitro evaluation of the effect of axial loading on 3 elements of implant-supported partial fixed prostheses, varying the type of prosthetic cylinder and the loading points. Material and methods: Three internal hexagon implants were linearly embedded in a polyurethane block. Microunit abutments were connected to the implants applying a torque of 20 Ncm, and prefabricated Co-Cr cylinders and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n = 5). Four strain gauges (SG) were bonded onto the surface of the block tangentially to the implants, SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments with a 10 Ncm torque and an axial load of 30 kg was applied at five predetermined points (A, B, C, D, E). The data obtained from the strain gauge analyses were analyzed statistically by RM ANOVA and Tukey's test, with a level of significance of p<0.05. Results: There was a significant difference for the loading point (p=0.0001), with point B generating the smallest microdeformation (239.49 με) and point D the highest (442.77 με). No significant difference was found for the cylinder type (p=0.748). Conclusions: It was concluded that the type of cylinder did not affect in the magnitude of microdeformation, but the axial loading location influenced this magnitude.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The substitution of steel as a raw material in the production of axial pistons for pressure washers by polyphthalamide, polytetrafluoroethylene and glass fiber-based composite was studied. The new production process with composite consists of only two steps, while the production of the steel piston is to comprise of thirteen steps. This replacement would result in an estimated reduction of 80% of water consumption, 83% of electricity consumption, 73% of the total cost and 88% of the final mass. With regard to the main mechanical properties required for the end product, the composite was found to withstand the critical axial loads and it shows acceptable wear resistance in an environment without lubrication, an additional advantage of this replacement. © 2012 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)