975 resultados para ATRIAL-FIBRILLATION
Resumo:
Vitamin K antagonists (VKAs) are still largely employed, even in nonvalvular atrial fibrillation (AF). Our aim was to study the clinical profile of octogenarians treated with oral anticoagulation and to study the effect of age on the quality of VKAs anticoagulation. Data are from a prospective national registry in an adult Spanish population of nonvalvular AF. We included 1637 patients who had been receiving VKAs for at least 6 months before enrolment. Mean age was 73.8 ± 9.4 years. Patients aged > 80 years (N = 429) had a high risk profile with higher risk of stroke and bleeding than younger patients; CHA2DS2-VASc (Cardiac failure, Hypertension, Age > 74, Diabetes, Stroke, Vascular disease, Age 65–74 years, and Sex category) 4.5 ± 1.3 vs. 3.5 ± 1.6, p < 0.001, HAS-BLED (Hypertension, Abnormal renal/liver function, Stroke, Bleeding history or predisposition, Labile international normalized ratio, Elderly (> 64 years), Drugs/alcohol concomitantly) 2.4 ± 0.9 vs. 1.9 ± 1.1, p < 0.001. Creatinine clearance was lower in octogenarians than in younger patients (54.3 ± 16.1 ml/min vs. 69.5 ± 23.7 ml/min, p < 0.001) and severe renal disease with creatinine clearance < 30 ml/min was more frequent in octogenarians (5.2% vs. 2.2%, p < 0.001). In patients treated with VKAs (N = 1637), the international normalized ratio values of the 6 months previous to enrollment were similar in all age quartiles, as was the time in the therapeutic range. In this large registry octogenarians with nonvalvular AF had high risk of stroke and bleeding and frequent renal disease. VKAs anticoagulation quality was similar in octogenarians and in younger patients.
Resumo:
Background Edoxaban, an oral factor Xa inhibitor, is non-inferior for prevention of stroke and systemic embolism in patients with atrial fibrillation and is associated with less bleeding than well controlled warfarin therapy. Few safety data about edoxaban in patients undergoing electrical cardioversion are available. Methods We did a multicentre, prospective, randomised, open-label, blinded-endpoint evaluation trial in 19 countries with 239 sites comparing edoxaban 60 mg per day with enoxaparin–warfarin in patients undergoing electrical cardioversion of non-valvular atrial fibrillation. The dose of edoxaban was reduced to 30 mg per day if one or more factors (creatinine clearance 15–50 mL/min, low bodyweight [≤60 kg], or concomitant use of P-glycoprotein inhibitors) were present. Block randomisation (block size four)—stratified by cardioversion approach (transoesophageal echocardiography [TEE] or not), anticoagulant experience, selected edoxaban dose, and region—was done through a voice-web system. The primary efficacy endpoint was a composite of stroke, systemic embolic event, myocardial infarction, and cardiovascular mortality, analysed by intention to treat. The primary safety endpoint was major and clinically relevant non-major (CRNM) bleeding in patients who received at least one dose of study drug. Follow-up was 28 days on study drug after cardioversion plus 30 days to assess safety. This trial is registered with ClinicalTrials.gov, number NCT02072434. Findings Between March 25, 2014, and Oct 28, 2015, 2199 patients were enrolled and randomly assigned to receive edoxaban (n=1095) or enoxaparin–warfarin (n=1104). The mean age was 64 years (SD 10·54) and mean CHA2DS2-VASc score was 2·6 (SD 1·4). Mean time in therapeutic range on warfarin was 70·8% (SD 27·4). The primary efficacy endpoint occurred in five (<1%) patients in the edoxaban group versus 11 (1%) in the enoxaparin–warfarin group (odds ratio [OR] 0·46, 95% CI 0·12–1·43). The primary safety endpoint occurred in 16 (1%) of 1067 patients given edoxaban versus 11 (1%) of 1082 patients given enoxaparin–warfarin (OR 1·48, 95% CI 0·64–3·55). The results were independent of the TEE-guided strategy and anticoagulation status. Interpretation ENSURE-AF is the largest prospective randomised clinical trial of anticoagulation for cardioversion of patients with non-valvular atrial fibrillation. Rates of major and CRNM bleeding and thromboembolism were low in the two treatment groups. Funding Daiichi Sankyo provided financial support for the study. © 2016 Elsevier Ltd
Resumo:
Atrial fibrillation is associated with a five-fold increase in the risk of cerebrovascular events,being responsible of 15-18% of all strokes.The morphological and functional remodelling of the left atrium caused by atrial fibrillation favours blood stasis and, consequently, stroke risk. In this context, several clinical studies suggest that stroke risk stratification could be improved by using haemodynamic information on the left atrium (LA) and the left atrial appendage (LAA). The goal of this study was to develop a personalized computational fluid-dynamics (CFD) model of the left atrium which could clarify the haemodynamic implications of atrial fibrillation on a patient specific basis. The developed CFD model was first applied to better understand the role of LAA in stroke risk. Infact, the interplay of the LAA geometric parameters such as LAA length, tortuosity, surface area and volume with the fluid-dynamics parameters and the effects of the LAA closure have not been investigated. Results demonstrated the capabilities of the CFD model to reproduce the real physiological behaviour of the blood flow dynamics inside the LA and the LAA. Finally, we determined that the fluid-dynamics parameters enhanced in this research project could be used as new quantitative indexes to describe the different types of AF and open new scenarios for the patient-specific stroke risk stratification.
Resumo:
Objectives This prospective study evaluated the association of obesity and hypertension with left atrial (LA) volume over 10 years. Background Although left atrial enlargement (LAE) is an independent risk factor for atrial fibrillation, stroke, and death, little information is available about determinants of LA size in the general population. Methods Participants (1,212 men and women, age 25 to 74 years) originated from a sex-and age-stratified random sample of German residents of the Augsburg area (MONICA S3). Left atrial volume was determined by standardized echocardiography at baseline and again after 10 years. Left atrial volume was indexed to body height (iLA). Left atrial enlargement was defined as iLA >= 35.7 and >= 33.7 ml/m in men and women, respectively. Results At baseline, the prevalence of LAE was 9.8%. Both obesity and hypertension were independent predictors of LAE, obesity (odds ratio [OR]: 2.4; p < 0.001) being numerically stronger than hypertension (OR: 2.2; p < 0.001). Adjusted mean values for iLA were significantly lower in normal-weight hypertensive patients (25.4 ml/m) than in obese normotensive individuals (27.3 ml/m; p = 0.016). The highest iLA was found in the obese hypertensive subgroup (30.0 ml/m; p < 0.001 vs. all other groups). This group also presented with the highest increase in iLA (+6.0 ml/m) and the highest incidence (31.6%) of LAE upon follow-up. Conclusions In the general population, obesity appears to be the most important risk factor for LAE. Given the increasing prevalence of obesity, early interventions, especially in young obese individuals, are essential to prevent premature onset of cardiac remodeling at the atrial level. (J Am Coll Cardiol 2009; 54: 1982-9) (C) 2009 by the American College of Cardiology Foundation
Management of posterior atrial wall perforation during transseptal approach for left atrium ablation
Resumo:
A patient with heart failure and acute atrial fibrillation received the final diagnosis of atrial infarction associated with ventricular infarction based on clinical findings of ischemia in association with atrial fibrillation and heart failure (mechanisms probably involved: contractile dysfunction and loss of atrial contribution). Although a transesophageal echocardiography, which could refine the diagnosis of anatomic abnormalities, was not performed, all evidence led to the diagnosis of atrial involvement. Electrocardiographic findings were consistent with Liu's major criterion 3. Therapy with digitalis, quinidine and angiotensin-converting enzyme inhibitors was chosen, as the patient had acute pulmonary edema. The use of beta-blockers and verapamil was restricted. No other complications, such as thrombo-embolism or atrial rupture, were noted.
Resumo:
OBJECTIVE: To identify useful clinical characteristics for selecting patients eligible for mapping and ablation of atrial fibrillation. METHODS: We studied 9 patients with atrial fibrillation, without structural heart disease, associated with: 1) antiarrhythmic drugs, 2) symptoms of low cardiac output, and 3) intention to treat. Seven patients had paroxysmal atrial fibrillation and 2 had recurrent atrial fibrillation. RESULTS: In the 6 patients who underwent mapping (all had paroxysmal atrial fibrillation), catheter ablation was successfully carried out in superior pulmonary veins in 5 patients (the first 3 in the left superior pulmonary vein and the last 2 in the right superior pulmonary vein). One patient experienced a recurrence of atrial fibrillation after 10 days. We observed that patients who had short episodes of atrial fibrillation on 24-hour Holter monitoring before the procedure were those in whom mapping the focus of tachycardia was possible. Tachycardia was successfully suppressed in 4 of 6 patients. The cause of failure was due to the impossibility of maintaining sinus rhythm long enough for efficient mapping. CONCLUSION: Patients experiencing short episodes of atrial fibrillation during 24-hour Holter monitoring were the most eligible for mapping and ablation, with a final success rate of 66%, versus the global success rate of 44%. Patients with persistent atrial fibrillation were not good candidates for focal ablation.
Resumo:
BACKGROUND: Atrial arrhythmias increase disease burden in the general adult population. Adults with congenital heart lesions constitute a rapidly growing group of patients with cardiovascular disease. We hypothesized that atrial arrhythmias increase with age and impair health outcomes in this population. METHODS AND RESULTS: We conducted a population-based analysis of prevalence, lifetime risk, mortality, and morbidity associated with atrial arrhythmias in adults with congenital heart disease from l983 to 2005. In 38 428 adults with congenital heart disease in 2005, 5812 had atrial arrhythmias. Overall, the 20-year risk of developing atrial arrhythmia was 7% in a 20-year-old subject and 38% in a 50-year-old subject. More than 50% of patients with severe congenital heart disease reaching age 18 years developed atrial arrhythmias by age 65 years. In patients with congenital heart disease, the hazard ratio of any adverse event in those with atrial arrhythmias compared with those without was 2.50 (95% confidence interval, 2.38 to 2.62; P<0.0001), with a near 50% increase in mortality (hazard ratio, 1.47; 95% confidence interval, 1.37 to 1.58; P<0.001), more than double the risk of morbidity (stroke or heart failure) (hazard ratio, 2.21; 95% confidence interval, 2.07 to 2.36; P<0.001), and 3 times the risk of cardiac interventions (hazard ratio, 3.00; 95% confidence interval, 2.81 to 3.20; P<0.001). CONCLUSIONS: Atrial arrhythmias occurred in 15% of adults with congenital heart disease. The lifetime incidence increased steadily with age and was associated with a doubling of the risk of adverse events. An increase in resource allocation should be anticipated to deal with this increasing burden.
Resumo:
OBJECTIVE: Atrial fibrillation is a very common heart arrhythmia, associated with a five-fold increase in the risk of embolic strokes. Treatment strategies encompass palliative drugs or surgical procedures all of which can restore sinus rhythm. Unfortunately, atria often fail to recover their mechanical function and patients therefore require lifelong anticoagulation therapy. A motorless volume displacing device (Atripump) based on artificial muscle technology, positioned on the external surface of atrium could avoid the need of oral anticoagulation and its haemorrhagic complications. An animal study was conducted in order to assess the haemodynamic effects that such a pump could provide. METHODS: Atripump is a dome-shape siliconecoated nitinol actuator sewn on the external surface of the atrium. It is driven by a pacemaker-like control unit. Five non-anticoagulated sheep were selected for this experiment. The right atrium was surgically exposed, the device sutured and connected. Haemodynamic parameters and intracardiac ultrasound (ICUS) data were recorded in each animal and under three conditions; baseline; atrial fibrillation (AF); atripump assisted AF (aaAF). RESULTS: In two animals, after 20 min of AF, small thrombi appeared in the right atrial appendix and were washed out once the pump was turned on. Assistance also enhanced atrial ejection fraction. 31% baseline; 5% during AF; 20% under aaAF. Right atrial systolic surfaces (cm2) were; 5.2 +/- 0.3 baseline; 6.2 +/- 0.1 AF; 5.4 +/- 0.3 aaAF. CONCLUSION: This compact and reliable pump seems to restore the atrial "kick" and prevents embolic events. It could avoid long-term anticoagulation therapy and open new hopes in the care of end-stage heart failure.
Resumo:
BACKGROUND: An elevated early (E) to late (A) diastolic filling velocities ratio, typically seen in advanced diastolic dysfunction, has also been observed after cardioversion of atrial fibrillation as a consequence of the depressed left atrial (LA) contractility. We hypothesized that the impaired LA contractile function demonstrated after orthotopic cardiac transplantation (OCT) could also lead to this "pseudorestrictive" pattern. METHOD: E/A ratio related to the tissue Doppler early mitral annular velocity (Ea) as preload-independent index of LV relaxation was evaluated in all consecutive OCT patients between 2005 and 2007. RESULTS: The study population comprised 48 patients 97 ± 77 months after OCT. Thirty-two patients (67%) had an E/A ratio > 2. LV systolic function and myocardial relaxation assessed by the Ea velocity were similar compared to patients with normal ratio (61 ± 6% vs. 60 ± 12%, P = 0.854 and 15 ± 4 cm/s vs. 14 ± 3 cm/s, r = 0.15, P = 0.323, respectively). On the other hand, the proportion of the recipient and donor LA cuffs as estimated by the recipient/global LA area ratio and the LA emptying fraction significantly correlated with the E/A ratio (r = 0.40, P = 0.005 and r =-0.33, P = 0.022, respectively). CONCLUSION: Our study shows that there is a high prevalence of elevated E/A ratio after standard OCT which seems mainly related to reduced LA contractility. Recognition of this "pseudorestrictive" pattern may avoid misdiagnosis of diastolic dysfunction.
Resumo:
It has been shown that repolarization alternans, a beat-to-beat alternation in action potential duration, enhances dispersion of repolarization above a critical heart rate and promotes susceptibility to ventricular arrhythmias. It is unknown whether repolarization alternans is measurable in the atria using standard pacemakers and whether it plays a role in promoting atrial fibrillation. In this work, atrial repolarization alternans amplitude and periodicity are studied in a sheep model of pacing-induced atrial fibrillation. Two pacemakers, each with one right atrial and ventricular lead, were implanted in 4 male sheep after ablation of the atrioventricular junction. The first one was used to deliver rapid pacing for measurements of right atrial repolarization alternans and the second one to record a unipolar electrogram. Atrial repolarization alternans appeared rate-dependent and its amplitude increased as a function of pacing rate. Repolarization alternans was intermittent but no periodicity was detected. An increase of repolarization alternans preceding episodes of non-sustained atrial fibrillation suggests that repolarization alternans is a promising parameter for assessment of atrial fibrillation susceptibility.
Resumo:
Kinetics of Atrial Repolarization Alternans. INTRODUCTION: Repolarization alternans (Re-ALT), a beat-to-beat alternation in action potential repolarization, promotes dispersion of repolarization, wavebreaks, and reentry. Recently, Re-ALT has been shown to play an important role in the transition from rapid pacing to atrial fibrillation (AF) in humans. The detailed kinetics of atrial Re-ALT, however, has not been reported so far. We developed a chronic free-behaving ovine pacing model to study the kinetics of atrial Re-ALT as a function of pacing rate. METHODS: Thirteen sheep were chronically implanted with 2 pacemakers for the recording of broadband right atrial unipolar electrograms and delivery of rapid pacing protocols. Beat-to-beat differences in the atrial T-wave apex amplitude as a measure of Re-ALT and activation time were analyzed at incremental pacing rates until the effective refractory period (ERP) defined as stable 2:1 capture. RESULTS: Atrial Re-ALT appeared intermittently but without periodicity, and increased in amplitude as a function of pacing rate until ERP. Intermittent 2:1 atrial capture was observed at pacing cycle lengths 40 ms above ERP, and increased in duration as a function of pacing rate. Episodes of rapid pacing-induced AF were rare, and were preceded by Re-ALT or complex oscillations of atrial repolarization, but without intermittent capture. CONCLUSION: We show in vivo that atrial Re-ALT developed and increased in magnitude with rate until stable 2:1 capture. In rare instances where capture failure did not occur, Re-ALT and complex oscillations of repolarization surged and preceded AF initiation. (J Cardiovasc Electrophysiol, Vol. 23, pp. 1003-1012, September 2012).
Resumo:
Atrial arrhythmias (AAs) are a common complication in adult patients with congenital heart disease. We sought to compare the lifetime prevalence of AAs in patients with right- versus left-sided congenital cardiac lesions and their effect on the prognosis. A congenital heart disease diagnosis was assigned using the International Disease Classification, Ninth Revision, diagnostic codes in the administrative databases of Quebec, from 1983 to 2005. Patients with AAs were those diagnosed with an International Disease Classification, Ninth Revision, code for atrial fibrillation or intra-atrial reentry tachycardia. To ensure that the diagnosis of AA was new, a washout period of 5 years after entry into the database was used, a period during which the patient could not have received an International Disease Classification, Ninth Revision, code for AA. The cumulative lifetime risk of AA was estimated using the Practical Incidence Estimators method. The hazard ratios (HRs) for mortality, morbidity, and cardiac interventions were compared between those with right- and left-sided lesions after adjustment for age, gender, disease severity, and cardiac risk factors. In a population of 71,467 patients, 7,756 adults developed AAs (isolated right-sided, 2,229; isolated left-sided, 1,725). The lifetime risk of developing AAs was significantly greater in patients with right- sided than in patients with left-sided lesions (61.0% vs 55.4%, p <0.001). The HR for mortality and the development of stroke or heart failure was similar in both groups (HR 0.96, 95% confidence interval [CI] 0.86 to 1.09; HR 0.94, 95% CI 0.80 to 1.09; and HR 1.10, 95% CI 0.98 to 1.23, respectively). However, the rates of cardiac catheterization (HR 0.63, 95% CI 0.55 to 0.72), cardiac surgery (HR 0.40, 95% CI 0.36 to 0.45), and arrhythmia surgery (HR 0.77, 95% CI 0.6 to 0.98) were significantly less for patients with right-sided lesions. In conclusion, patients with right-sided lesions had a greater lifetime burden of AAs. However, their morbidity and mortality were no less than those with left-sided lesions, although the rate of intervention was substantially different.
Resumo:
De déterminer si une stratégie de contrôle du rythme améliore la qualité de vie et / ou la capacité fonctionnelle par rapport à une stratégie de contrôle de la fréquence cardiaque chez les patients atteints de fibrillation auriculaire et d'insuffisance cardiaque congestive. Méthode: Pour évaluer la qualité de vie, le questionnaire SF-36 a été administré à l'inclusion et à 4 mois chez 749 patients de l’étude AF-CHF. Les paramètres de capacité fonctionnelle évalués ont été la classe fonctionnelle NYHA (1376 patients) et la distance de marche de six minutes (1099 patients). Résultats: Le type du traitement assigné n'a pas eu un impact significatif sur la qualité de vie ou la capacité fonctionnelle. Conclusion: La qualité de vie et la capacité fonctionnelle sont similaires chez les patients randomisés au contrôle du rythme par rapport au contrôle de la fréquence. Les hommes non-obèses avec moins de comorbidités semblent plus susceptibles de s'améliorer.