344 resultados para ALGINATE
Resumo:
The response surface methodology as a tool for assessing the production of alginate and polyhydroxybutirate by Azotobacter vinelandii. Alginate is a polysaccharide extracted from cell walls of brown algae and used in the food, pharmaceuticals and biotech industries. Production is concentrated on the cultivation of brown seaweed, but several bacteria of the genus Pseudomonas and Azotobacter produce alginate. The chemical structure of alginates produced by algae is similar to those synthesized by A. vinelandii. The bacteria also produce intracellular polymers such as polyhydroxybutyrate (PHB), known as bioplastic. This work studied the simultaneous alginate and PHB production by A. vinelandii using sucrose and different parameters of fermentation in an orbital shaker. The optimal values for the production of these compounds were determined by the MSR. The first experiment was a 2(6-2) factorial design. The second was based on significant variables of the first, resulting in a full 3(3-0) factorial design. From the first to the second, an increase was observed in the PHB productivity from 12 to 45 mg g(-1) cell h(-1) and alginate from 100 to 1,600 mg g(-1) of cell h(-1). The productivity of both compounds was in the maximum incubation temperature of 62 degrees C, in the shortest time of incubation (18h) and the sucrose concentration, 11 g L(-1). In both experiments the PHB extracted presented purity of 94%.
Resumo:
Due to an increasing interest, a vast number of biodegradable polymers have been obtained recently. Polymers naturally produced, such as cellulose, starch, chitosan and alginate, represent biodegradable materials, with low toxicity and low cost. Among polysaccharides, chitosan has been of great interest of the industrial and academic research, due to its special qualities of biodegradability and biocompatibility and, on the other hand, to the versatility of its use in several physical forms and products. A significant growth in the development of new dosage forms capable to deliver the drug in a controlled and targeted way has been observed in these last years. Such pharmaceutical forms search, mainly, the reduction of the dose administered and of the administration frequency, the reduction of adverse side effects and, consequently, a better patient compliance. The present paper describes the use of chitosan in pharmaceutical products, especially in drug controlled delivery systems.
Resumo:
In this study, the aim was to measure the concentration of fluoride ions in dental alginates and the quantity released from alginate molds immersed in milliQ water, 0.1N hydrochloric acid and artificial saliva. Two separate lots of each of seven brands of alginate commercially available in Brazil were analyzed: Avagel, Deguprint, Hydrogum, Orthoprint, Jeltrate, Jeltrate Plus and Jeltrate Chromatic. Fluoride was measured in each sample by direct potentiometry, using the combined fluoride-ion selective electrode. The brands with the highest fluoride concentrations were Hydrogum (7052.87 μg/g), Jeltrate Plus (6519.68 μg/g) and Orthoprint (6218.18 μg/g). Only in Hydrogum and Jeltrate were different fluoride concentrations found in lots one and two. The various materials showed differences in the amount of fluoride released from the molds into the immersion medium, the mean concentration being highest in Hydrogum and Orthoprint, in all three media. The immersion medium also influenced the release of fluoride, which was lower in saliva than in water and highest in acid. Considering that the concentrations of fluoride found in the alginates tested were high and that various sources of exposure to fluoride exist, there is a need for constant monitoring of alginates intended for dental use.
Resumo:
Alginate is one the materials most employed in practice to make dental impressions. Substances like zinc, cadmium and lead silicate, which are included in several alginate brands with the aim of improving their physical, chemical and mechanical properties, are a source of serious concern as regards their toxicity. The most serious chronic effect of oral exposure to cadmium is renal toxicity. Assimilation of lead has deleterious effects on the gastrointestinal tract, hematopoietic system, cardiovascular system, central and peripheral nervous systems, kidneys, immune system, and reproductive system. Chronic oral exposures to zinc have resulted in hypochromic and microcyte anemia in some individuals. The aim of the present study was to measure the cadmium, lead and zinc contents of seven brands of alginate for dental use on sale in Brazil. The samples were weighed and placed in the Teflon cups of a closed-system microwave oven. Aqua regia (4mL concentrated HCI:HNO3, 3:1 v/v) and hydrofluoric acid (2mL concentrated HF) were added to the samples, which were then subjected to heating. The samples were then cooled to room temperature and diluted to 25 mL in deionized water in a volumetric glass flask. The samples were diluted in duplicate and analyzed against a reagent blank. The analyses were performed in an atomic absorption flame spectrophotometer. Neither lead nor cadmium was detected. Zinc contents ranged from 0.001% to 1.36% by weight. The alginates exhibited low contents of the metals under study and gave no cause for concern regarding toxicity; even so, it is advisable to monitor potentially toxic materials continually and to analyze their plasmatic levels in the professionals working with them.
Resumo:
Alginate or irreversible hydrocolloid is one the most accepted and frequently employed impression materials in dental practice. Substances like zinc, cadmium, lead silicate and fluorides, which are included in several alginate brands with the aim of improving their physical, chemical and mechanical properties, are a source of serious concern as regards their toxicity. Some brands of alginate have been reported to contain potentially toxic fluorides and metals such as cadmium, lead and zinc silicates, either singly or combined. Consequently, special care should be taken while preparing of these materials. It is necessary to monitor potentially toxic chemicals and metals in the alginates continually to avoid contamination of dental professionals and patients. In this review, alginates used in dentistry are analyzed for potential toxicity.
Resumo:
The Laboratory of Industrial Biotechnology at the Biological Sciences Department in Sao Paulo State University, Brazil is working to improve the technologies involved with isomaltulose production. The study evaluated enzymatic reaction parameters with the goal of improving isomaltulose production which is grown with a medium of 1% cane molasses and 0.5% yeast extract thereby using calcium alginate, glutaraldehyde and polyethyleneimine. The best results were obtained using P. rubrum immobilized pellets in calcium alginate with 705 and 60% sucrose solution. The developed technology apparently allows the reuse of the cell-containing enzymes more times compared to conventional technologies, which ultimately results in decreased costs. The researchers are also involved in alcohol and biopolymer production and seeking interested industrial collaborators.
Resumo:
This study evaluated the influence of tooth embedding media on the accuracy ofan electronic apex locator. The root canal length of 20 human mandibular canines was measured by inserting a 15 K-file into the root canal up to the apical foramen. The distance was measured with a digital caliper. The embedding media evaluated were alginate, saline, floral foam or gauze soaked in saline. Electronic root canal length measurement was performed with Root ZX II. Data were analysed using ANOVA for repeated measurements and Tukey test, at a significance level of 5%. There was no difference between the actual root canal length measurement and the electronic reading recorded with alginate medium. The readings obtained with the other media differed from the actual root canal length measurements. Alginate provided greater accuracy in electronic root canal length determination by Root ZX II than saline, floral foam and gauze.
Resumo:
The interpretation of the set of radiographs taken during the follow-up period after tooth replantation might pose several difficulties, especially the inability to adequately reproduce the projection geometry of the exposures. This article describes a method for the geometric standardization of intraoral radiographs using a custom-made apparatus comprising a film-holder attached to an occlusal splint for the long-term follow up of dentoalveolar trauma. The method was applied in a patient who suffered an avulsion of the maxillary central incisors and had the teeth replanted after 4 h in saline storage. Endodontic treatment started 7 days after the trauma with changes of a calcium hydroxide intracanal medication every 15 days in the first 2 months and thereafter at 30-day intervals for 8 months. Root canal filling was carried out after this period. The radiographic exposures taken at the follow-up visits were standardized to identify the possible alterations during the repair process, such as root resorptions. A maxillary arch impression was made with alginate, and the model was cast in stone for fabrication of an acetate occlusal splint. The custom-made apparatus used for standardization of the radiographic exposures was fabricated by fixing a Rinn X-C-P film-holder and a 5-mm-long piece of 0.7-mm orthodontic wire to the occlusal splint with autopolymerized acrylic resin. Radiographs were taken at 4-month intervals, starting 10 months after replantation up to 76 months. The images were digitized and analysed using the Digora system. The length of the central incisors was determined to verify the reproduction of the projection geometry of the exposures and the orthodontic wire served to assess accuracy during length estimations in the radiographs. The method described in this article for geometric standardization of intraoral radiographs provided a consistent reproduction of the geometric exposure parameters, being indicated for use in the radiographic follow up of cases of dentoalveolar trauma. © 2012 John Wiley & Sons A/S.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Biotecnologia - IQ
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Pesquisa e Desenvolvimento (Biotecnologia Médica) - FMB
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)