841 resultados para AIP
Resumo:
The effects of different forage mixtures on duodenal flow and faecal output of phosphorus (P) were measured in lactating dairy cows in two experiments. The forages comprised grass silage (GS) alone or mixtures of GS and urea-treated whole crop wheat (WCW). Replacement of GS by high levels of WCW resulted in a significant decrease in total P (TP), water-soluble P (WSP) and acid-soluble P (ASP) intakes, but increased phytate P (PP) and acid-insoluble P (AIP) intakes. Duodenal flows of all P fractions were unaffected by dietary treatments. However, the amounts of all fractions flowing to the intestine were much higher than the amounts consumed-with the exception of AIP, which was unchanged, and PP, which was considerably reduced. Diets did not significantly affect faecal outputs of TP, ASP, PP and AIP; however, faecal outputs of WSP were significantly higher on WCW than GS diets. Inclusion of WCW significantly decreased TP and WSP availabilities in the total tract but did not affect PP and AIP availabilities. A new fraction of P, which was not present in the feeds, was found in significant amounts in the intestines and proved to be soluble in dilute acid but insoluble in water. Estimated annual excretions for a herd of 100 cows ranged from 1550 to 1721 kg for total P of which 337-786 kg was WSP. The results suggest that GS based diets deposit more P in the environment. However, the potential to cause P pollution depends not only on the quantity but also on the nature of faecal P and on soil parameters. © 2004 Elsevier B.V. All rights reserved.
Resumo:
A proper method to assess contractor competitiveness is important both for assisting clients in the selection of proper contractors and for assisting contractors in the development of more competitive bidding strategies. Previous studies have identified various indicators for assessing contractor competitiveness, and several assessment methods have been introduced. Nevertheless, these studies are limited because they are unable to tell which indicators are more important in different market environments. This paper identifies the key competitiveness indicators �KCIs� for assessing contractor competitiveness in the Chinese construction market. An index value is used to indicate the relative significance of various competitiveness indicators based on which KCIs are identified. The data applied in this study are from a survey of the construction industry in mainland China. The research findings provide valuable information for both existing businesses and the construction professionals who plan to compete for construction works in the Chinese market. The study provides useful references for further studies that compare the KCIs used in the Chinese construction industry and those used in other construction industries.
Resumo:
This paper identifies the major challenges in the area of pattern formation. The work is also motivated by the need for development of a single framework to surmount these challenges. A framework based on the control of macroscopic parameters is proposed. The issue of transformation of patterns is specifically considered. A definition for transformation and four special cases, namely elementary and geometrical transformations by repositioning all or some robots in the pattern are provided. Two feasible tools for pattern transformation namely, a macroscopic parameter method and a mathematical tool - Moebius transformation also known as the linear fractional transformation are introduced. The realization of the unifying framework considering planning and communication is reported.
Resumo:
Virulence in Staphylococcus aureus is regulated via agr-dependent quorum sensing in which an autoinducing peptide (AIP) activates AgrC, a histidine protein kinase. AIPs are usually thiolactones containing seven to nine amino acid residues in which the thiol of the central cysteine is linked to the alpha-carboxyl of the C-terminal amino acid residue. The staphylococcal agr locus has diverged such that the AIPs of the four different S. aureus agr groups self-activate but cross-inhibit. Consequently, although the agr system is conserved among the staphylococci, it has undergone significant evolutionary divergence whereby to retain functionality, any changes in the AIP-encoding gene (agrD) that modifies AIP structure must be accompanied by corresponding changes in the AgrC receptor. Since AIP-1 and AIP-4 only differ by a single amino acid, we compared the transmembrane topology of AgrC1 and AgrC4 to identify amino acid residues involved in AIP recognition. As only two of the three predicted extracellular loops exhibited amino acid differences, site-specific mutagenesis was used to exchange the key AgrC1 and AgrC4 amino acid residues in each loop either singly or in combination. A novel lux-based agrP3 reporter gene fusion was constructed to evaluate the response of the mutated AgrC receptors. The data obtained revealed that while differential recognition of AIP-1 and AIP-4 depends primarily on three amino acid residues in loop 2, loop 1 is essential for receptor activation by the cognate AIP. Furthermore, a single mutation in the AgrC1 loop 2 resulted in conversion of (Ala5)AIP-1 from a potent antagonist to an activator, essentially resulting in the forced evolution of a new AIP group. Taken together, our data indicate that loop 2 constitutes the predicted hydrophobic pocket that binds the AIP thiolactone ring while the exocyclic amino acid tail interacts with loop 1 to facilitate receptor activation.
Resumo:
Two vertical cosmic ray telescopes for atmospheric cosmic ray ionization event detection are compared. Counter A, designed for low power remote use, was deployed in the Welsh mountains; its event rate increased with altitude as expected from atmospheric cosmic ray absorption. Independently, Counter B’s event rate was found to vary with incoming particle acceptance angle. Simultaneous colocated comparison of both telescopes exposed to atmospheric ionization showed a linear relationship between their event rates.
Resumo:
Techniques for the coherent generation and detection of electromagnetic radiation in the far infrared, or terahertz, region of the electromagnetic spectrum have recently developed rapidly and may soon be applied for in vivo medical imaging. Both continuous wave and pulsed imaging systems are under development, with terahertz pulsed imaging being the more common method. Typically a pump and probe technique is used, with picosecond pulses of terahertz radiation generated from femtosecond infrared laser pulses, using an antenna or nonlinear crystal. After interaction with the subject either by transmission or reflection, coherent detection is achieved when the terahertz beam is combined with the probe laser beam. Raster scanning of the subject leads to an image data set comprising a time series representing the pulse at each pixel. A set of parametric images may be calculated, mapping the values of various parameters calculated from the shape of the pulses. A safety analysis has been performed, based on current guidelines for skin exposure to radiation of wavelengths 2.6 µm–20 mm (15 GHz–115 THz), to determine the maximum permissible exposure (MPE) for such a terahertz imaging system. The international guidelines for this range of wavelengths are drawn from two U.S. standards documents. The method for this analysis was taken from the American National Standard for the Safe Use of Lasers (ANSI Z136.1), and to ensure a conservative analysis, parameters were drawn from both this standard and from the IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields (C95.1). The calculated maximum permissible average beam power was 3 mW, indicating that typical terahertz imaging systems are safe according to the current guidelines. Further developments may however result in systems that will exceed the calculated limit. Furthermore, the published MPEs for pulsed exposures are based on measurements at shorter wavelengths and with pulses of longer duration than those used in terahertz pulsed imaging systems, so the results should be treated with caution.
Resumo:
A radiometric analysis of the light coupled by optical fiber amplitude modulating extrinsic-type reflectance displacement sensors is presented. Uncut fiber sensors show the largest range but a smaller responsivity. Single cut fiber sensors exhibit an improvement in responsivity at the expense of range. A further increase in responsivity as well as a reduction in the operational range is obtained when the double cut sensor configuration is implemented. The double cut configuration is particularly suitable in applications where feedback action is applied to the moving reflector surface. © 2000 American Institute of Physics.
Resumo:
The precision of quasioptical null-balanced bridge instruments for transmission and reflection coefficient measurements at millimeter and submillimeter wavelengths is analyzed. A Jones matrix analysis is used to describe the amount of power reaching the detector as a function of grid angle orientation, sample transmittance/reflectance and phase delay. An analysis is performed of the errors involved in determining the complex transmission and reflection coefficient after taking into account the quantization error in the grid angle and micrometer readings, the transmission or reflection coefficient of the sample, the noise equivalent power of the detector, the source power and the post-detection bandwidth. For a system fitted with a rotating grid with resolution of 0.017 rad and a micrometer quantization error of 1 μm, a 1 mW source, and a detector with a noise equivalent power 5×10−9 W Hz−1/2, the maximum errors at an amplitude transmission or reflection coefficient of 0.5 are below ±0.025.
Resumo:
A low cost, disposable instrument for measuring solar radiation during meteorological balloon flights through cloud layers is described. Using a photodiode detector and low thermal drift signal conditioning circuitry, the device showed less than 1% drift for temperatures varied from +20 °C to −35 °C. The angular response to radiation, which declined less rapidly than the cosine of the angle between the incident radiation and normal incidence, is used for cloud detection exploiting the motion of the platform. Oriented upwards, the natural motion imposed by the balloon allows cloud and clear air to be distinguished by the absence of radiation variability within cloud, where the diffuse radiation present is isotropic. The optical method employed by the solar radiation instrument has also been demonstrated to provide higher resolution measurements of cloud boundaries than relative humidity measurements alone.
Resumo:
A programmable data acquisition system to allow novel use of meteorological radiosondes for atmospheric science measurements is described. In its basic form it supports four analogue inputs at 16 bit resolution, and up to two further inputs at lower resolution configurable instead for digital instruments. It also provides multiple instrument power supplies (+8V, +16V, +5V and -8V) from the 9V radiosonde battery. During a balloon flight encountering air temperatures from +17°C to -66°C, the worst case voltage drift in the 5V unipolar digitisation circuitry was 20mV. The system liberates a new range of low cost atmospheric research measurements, by utilising radiosondes routinely launched internationally for weather forecasting purposes. No additional receiving equipment is required. Comparisons between the specially instrumented and standard meteorological radiosondes show negligible effect of the additional instrumentation on the standard meteorological data.
Resumo:
Measurements of atmospheric corona currents have been made for over 100 years to indicate the atmospheric electric field. Corona currents vary substantially, in polarity and in magnitude. The instrument described here uses a sharp point sensor connected to a temperature compensated bi-polar logarithmic current amplifier. Calibrations over a range of currents from ±10 fA to ±3 μA and across ±20 ◦C show it has an excellent logarithmic response over six orders of magnitude from 1 pA to 1 μA in both polarities for the range of atmospheric temperatures likely to be encountered in the southern UK. Comparison with atmospheric electric field measurements during disturbed weather confirms that bipolar electric fields induce corona currents of corresponding sign, with magnitudes ∼0.5 μA.
Resumo:
Atmospheric profiles of cosmic rays and radioactivity can be obtained using adapted meteorologi- cal radiosondes, for which Geiger tubes remain widely used detectors. Simultaneous triggering of two tubes provides an indication of energetic events. As, however, only small volume detectors can be carried, the event rate is small, which, due to the rapid balloon ascent, cannot be circumvented using long averaging periods. To derive count rates at low altitudes, a microcontroller is used to de- termine the inter-event time. This yields estimates of the coincidence rate below 5 km, where the coincidence rate is too small to determine solely by event counting
Resumo:
An optically transparent thin-layer electrochemical (OTTLE) cell with a locally extended optical path has been developed in order to perform vibrational circular dichroism (VCD) spectroscopy on chiral molecules prepared in specific oxidation states by means of electrochemical reduction or oxidation. The new design of the electrochemical cell successfully addresses the technical challenges involved in achieving sufficient infrared absorption. The VCD-OTTLE cell proves to be a valuable tool for the investigation of chiral redox-active molecules.
Resumo:
Charged aerosol particles and water droplets are abundant throughout the lower atmosphere, and may influence interactions between small cloud droplets. This note describes a small, disposable sensor for the measurement of charge in non-thunderstorm cloud, which is an improvement of an earlier sensor [K. A. Nicoll and R. G. Harrison, Rev. Sci. Instrum. 80, 014501 (2009)]. The sensor utilizes a self-calibrating current measurement method. It is designed for use on a free balloon platform alongside a standard meteorological radiosonde, measuring currents from 2 fA to 15 pA and is stable to within 5 fA over a temperature range of 5 °C to −60 °C. During a balloon flight with the charge sensor through a stratocumulus cloud, charge layers up to 40 pC m−3 were detected on the cloud edges.
Resumo:
We present an efficient method of combining wide angle neutron scattering data with detailed atomistic models, allowing us to perform a quantitative and qualitative mapping of the organisation of the chain conformation in both glass and liquid phases. The structural refinement method presented in this work is based on the exploitation of the intrachain features of the diffraction pattern and its intimate linkage with atomistic models by the use of internal coordinates for bond lengths, valence angles and torsion rotations. Atomic connectivity is defined through these coordinates that are in turn assigned by pre-defined probability distributions, thus allowing for the models in question to be built stochastically. Incremental variation of these coordinates allows for the construction of models that minimise the differences between the observed and calculated structure factors. We present a series of neutron scattering data of 1,2 polybutadiene at the region 120-400K. Analysis of the experimental data yield bond lengths for C-C and C=C of 1.54Å and 1.35Å respectively. Valence angles of the backbone were found to be at 112° and the torsion distributions are characterised by five rotational states, a three-fold trans-skew± for the backbone and gauche± for the vinyl group. Rotational states of the vinyl group were found to be equally populated, indicating a largely atactic chan. The two backbone torsion angles exhibit different behaviour with respect to temperature of their trans population, with one of them adopting an almost all trans sequence. Consequently the resulting configuration leads to a rather persistent chain, something indicated by the value of the characteristic ratio extrapolated from the model. We compare our results with theoretical predictions, computer simulations, RIS models and previously reported experimental results.