958 resultados para ACID ETCHING TIME
Resumo:
Molecules are the smallest possible elements for electronic devices, with active elements for such devices typically a few Angstroms in footprint area. Owing to the possibility of producing ultrahigh density devices, tremendous effort has been invested in producing electronic junctions by using various types of molecules. The major issues for molecular electronics include (1) developing an effective scheme to connect molecules with the present micro- and nano-technology, (2) increasing the lifetime and stabilities of the devices, and (3) increasing their performance in comparison to the state-of-the-art devices. In this work, we attempt to use carbon nanotubes (CNTs) as the interconnecting nanoelectrodes between molecules and microelectrodes. The ultimate goal is to use two individual CNTs to sandwich molecules in a cross-bar configuration while having these CNTs connected with microelectrodes such that the junction displays the electronic character of the molecule chosen. We have successfully developed an effective scheme to connect molecules with CNTs, which is scalable to arrays of molecular electronic devices. To realize this far reaching goal, the following technical topics have been investigated. 1. Synthesis of multi-walled carbon nanotubes (MWCNTs) by thermal chemical vapor deposition (T-CVD) and plasma-enhanced chemical vapor deposition (PECVD) techniques (Chapter 3). We have evaluated the potential use of tubular and bamboo-like MWCNTs grown by T-CVD and PE-CVD in terms of their structural properties. 2. Horizontal dispersion of MWCNTs with and without surfactants, and the integration of MWCNTs to microelectrodes using deposition by dielectrophoresis (DEP) (Chapter 4). We have systematically studied the use of surfactant molecules to disperse and horizontally align MWCNTs on substrates. In addition, DEP is shown to produce impurityfree placement of MWCNTs, forming connections between microelectrodes. We demonstrate the deposition density is tunable by both AC field strength and AC field frequency. 3. Etching of MWCNTs for the impurity-free nanoelectrodes (Chapter 5). We show that the residual Ni catalyst on MWCNTs can be removed by acid etching; the tip removal and collapsing of tubes into pyramids enhances the stability of field emission from the tube arrays. The acid-etching process can be used to functionalize the MWCNTs, which was used to make our initial CNT-nanoelectrode glucose sensors. Finally, lessons learned trying to perform spectroscopic analysis of the functionalized MWCNTs were vital for designing our final devices. 4. Molecular junction design and electrochemical synthesis of biphenyl molecules on carbon microelectrodes for all-carbon molecular devices (Chapter 6). Utilizing the experience gained on the work done so far, our final device design is described. We demonstrate the capability of preparing patterned glassy carbon films to serve as the bottom electrode in the new geometry. However, the molecular switching behavior of biphenyl was not observed by scanning tunneling microscopy (STM), mercury drop or fabricated glassy carbon/biphenyl/MWCNT junctions. Either the density of these molecules is not optimum for effective integration of devices using MWCNTs as the nanoelectrodes, or an electroactive contaminant was reduced instead of the ionic biphenyl species. 5. Self-assembly of octadecanethiol (ODT) molecules on gold microelectrodes for functional molecular devices (Chapter 7). We have realized an effective scheme to produce Au/ODT/MWCNT junctions by spanning MWCNTs across ODT-functionalized microelectrodes. A percentage of the resulting junctions retain the expected character of an ODT monolayer. While the process is not yet optimized, our successful junctions show that molecular electronic devices can be fabricated using simple processes such as photolithography, self-assembled monolayers and dielectrophoresis.
Resumo:
BACKGROUND: Gastroesophageal reflux is implicated in the pathogenesis of asthma and chronic cough. To date most studies have focused on acid reflux measured by pH below the upper esophageal sphincter (UES). The aim of this study was to assess the relationship between cough and reflux through the UES into the pharynx. METHODS: Thirty-seven patients with asthma (19) and chronic cough (18) were recruited from the respiratory clinic. Reflux was monitored using a combined multichannel intraluminal impedance and pH probe by detecting (1) bolus reflux episodes within the esophagus and in the pharynx and (2) acidic reflux episodes within the esophagus and in the pharynx. All acid suppressive therapy was stopped for at least 7 days before the study. Demonstration of cough being linked to reflux was achieved using the symptom association probability (SAP). This was calculated using a 2-minute association window between symptoms and bolus entry into the esophagus. SAP was considered positive if >95%. RESULTS: A positive SAP for cough was noted in 7/26 patients reporting symptoms on the day of monitoring. Compared with SAP-negative patients, SAP-positive patients had both a greater number [median (interquartile range), 5(2 to 8) vs. 2(0 to 4), P<0.05] and a higher proportion of reflux episodes crossing the UES into the pharynx [25%(14% to 28%) vs. 7% (2% to 14%), P<0.02]. There was no difference in the number of reflux episodes or acid exposure time in the distal esophagus between SAP-positive and SAP-negative patients. Only 1% to 2% of episodes were detected by the pharyngeal pH sensor. CONCLUSIONS: Impedance detected pharyngeal reflux episodes are important factors in symptom production in cough patients.
Resumo:
INTRODUCTION: Functional dyspepsia and non-erosive reflux disease (NERD) are prevalent gastrointestinal conditions with accumulating evidence regarding an overlap between the two. Still, patients with NERD represent a very heterogeneous group and limited data on dyspeptic symptoms in various subgroups of NERD are available. AIM: To evaluate the prevalence of dyspeptic symptoms in patients with NERD subclassified by using 24 h impedance-pH monitoring (MII-pH). METHODS: Patients with typical reflux symptoms and normal endoscopy underwent impedance-pH monitoring off proton pump inhibitor treatment. Oesophageal acid exposure time (AET), type of acid and non-acid reflux episodes, and symptom association probability (SAP) were calculated. A validated dyspepsia questionnaire was used to quantify dyspeptic symptoms prior to reflux monitoring. RESULTS: Of 200 patients with NERD (105 female; median age, 48 years), 81 (41%) had an abnormal oesophageal AET (NERD pH-POS), 65 (32%) had normal oesophageal AET and positive SAP for acid and/or non-acid reflux (hypersensitive oesophagus), and 54 (27%) had normal oesophageal AET and negative SAP (functional heartburn). Patients with functional heartburn had more frequent (p<0.01) postprandial fullness, bloating, early satiety and nausea compared to patients with NERD pH-POS and hypersensitive oesophagus. CONCLUSION: The increased prevalence of dyspeptic symptoms in patients with functional heartburn reinforces the concept that functional gastrointestinal disorders extend beyond the boundaries suggested by the anatomical location of symptoms. This should be regarded as a further argument to test patients with symptoms of gastro-oesophageal reflux disease in order to separate patients with functional heartburn from patients with NERD in whom symptoms are associated with gastro-oesophageal reflux.
Resumo:
OBJECTIVES: To determine the effect on resin composite-to-dentin bond strength of incorporation of an acidic tin-chloride pretreatment in two adhesive systems. MATERIALS AND METHODS: Human molars were ground to expose mid-coronal dentin. For microtensile bond strength (μTBS) testing, dentin was treated with Optibond FL or Clearfil SE according to one of six protocols (n = 22/group). Group 1: Phosphoric acid etching, Optibond FL Prime, Optibond FL Adhesive (manufacturer's instructions; control); Group 2: Tin-chloride pretreatment, Optibond FL Prime, Optibond FL Adhesive; Group 3: Phosphoric acid etching, tin-chloride pretreatment, Optibond FL Prime, Optibond FL Adhesive; Group 4: Clearfil SE Primer, Clearfil SE Bond (manufacturer's instructions; control); Group 5: Phosphoric acid etching, Clearfil SE Primer, Clearfil SE Bond; and Group 6: Tin-chloride pretreatment, Clearfil SE Primer, Clearfil SE Bond. The molars were then built up with resin composite (Clearfil Majesty Esthetic). After storage (1 week, 100 % humidity, 37 °C) the μTBS was measured and failure mode was determined. Additionally, pretreated dentin surfaces were evaluated using SEM and EDX. The μTBS results were analyzed statistically by a Welch Two Sample t-test and a Kruskal-Wallis test followed by exact Wilcoxon rank sum tests with Bonferroni-Holm adjustment for multiple testing (α = 0.05). RESULTS: When Optibond FL was used, partial or total replacement of phosphoric acid with tin-chloride decreased μTBS significantly. In contrast, when Clearfil SE was used, inclusion of a tin-chloride pretreatment in the adhesive procedure increased μTBS significantly. CONCLUSIONS: Tin-chloride pretreatment had a beneficial influence on the bond promoting capacity of the MDP-containing adhesive system Clearfil SE.
Resumo:
BACKGROUND & AIMS: Esophageal impedance measurements have been proposed to indicate the status of the esophageal mucosa, and might be used to study the roles of the impaired mucosal integrity and increased acid sensitivity in patients with heartburn. We compared baseline impedance levels among patients with heartburn who did and did not respond to proton pump inhibitor (PPI) therapy, along with the pathophysiological characteristics of functional heartburn (FH). METHODS: In a case-control study, we collected data from January to December 203 on patients with heartburn and normal findings from endoscopy who were not receiving PPI therapy and underwent impedance pH testing at hospitals in Italy. Patients with negative test results were placed on an 8-week course of PPI therapy (84 patients received esomeprazole and 36 patients received pantoprazole). Patients with more than 50% symptom improvement were classified as FH/PPI responders and patients with less than 50% symptom improvement were classified as FH/PPI nonresponders. Patients with hypersensitive esophagus and healthy volunteers served as controls. In all patients and controls, we measured acid exposure time, number of refluxes, baseline impedance, and swallow-induced peristaltic wave indices. RESULTS: FH/PPI responders had higher acid exposure times, numbers of reflux events, and acid refluxes compared with FH/PPI nonresponders (P < .05). Patients with hypersensitive esophagus had mean acid exposure times and numbers of reflux events similar to those of FH/PPI responders. Baseline impedance levels were lower in FH/PPI responders and patients with hypersensitive esophagus, compared with FH/PPI nonresponders and healthy volunteers (P < .001). Swallow-induced peristaltic wave indices were similar between FH/PPI responders and patients with hypersensitive esophagus. CONCLUSIONS: Patients with FH who respond to PPI therapy have impedance pH features similar to those of patients with hypersensitive esophagus. Baseline impedance measurements might allow for identification of patients who respond to PPIs but would be classified as having FH based on conventional impedance-pH measurements.
Resumo:
Background: Dental erosion is a complication of gastro-oesophageal reflux disease (GORD) according to the Montreal consensus statement. However, GORD has not been comprehensively characterized in patients with dental erosions and pH-impedance measures have not been reported. Objectives: Characterize GORD in patients with dental erosions using 24-h multichannel intraluminal pH-impedance measurements (pH-MII) and endoscopy. Methods: This single-centre study investigated reflux in successive patients presenting to dentists with dental erosion using pH-MII and endoscopy. Results: Of the 374 patients, 298 (80%) reported GORD symptoms <2 per week, 72 (19%) had oesophagitis and 59 (16%) had a hiatal hernia. In the 349 with pH-MII the mean percentage time with a pH <4 (95% CI) was 11.0 (9.3–12.7), and 34.4% (31.9–36.9) for a pH <5.5, a critical threshold for dental tissue. The mean numbers of total, acidic and weakly acidic reflux episodes were 71 (63–79), 43 (38–49) and 31 (26–35), respectively. Of the reflux episodes, 19% (17–21) reached the proximal oesophagus. In 241 (69%) patients reflux was abnormal using published normal values for acid exposure time and reflux episodes. No significant associations between the severity of dental erosions and any reflux variables were found. The presence of GORD symptoms and of oesophagitis or a hiatal hernia was associated with greater reflux, but not with increased dental erosion scores. Conclusions: Significant oligosymptomatic gastro-oesophageal reflux occurs in the majority of patients with dental erosion. The degree of dental erosion did not correlate with any of the accepted quantitative reflux indicators. Definition of clinically relevant reflux parameters by pH-MII for dental erosion and of treatment guidelines are outstanding. Gastroenterologists and dentists need to be aware of the widely prevalent association between dental erosion and atypical GORD.
Resumo:
OBJECTIVE The aim of this study was to investigate the effect of different energy settings of Er:YAG laser irradiation on dentin surface morphology with respect to the number of opened dentinal tubules. BACKGROUND DATA An ideally prepared dentin surface with opened dentinal tubules is a prerequisite for adhesive fixation. No study, however, has yet compared the numbers of opened dentinal tubules with regard to statistical differences. METHODS Conventional preparations using a bur with or without additional acid etching acted as control groups. Dentin specimens were prepared from human third molars and randomly divided into eight groups according to the energy settings of the laser (1, 1.5, 4, 6, 7.5, and 8 W) and two controls (bur and bur plus acid etching). After surface preparation, dentin surfaces were analyzed with a scanning electron microscope, and the number of opened dentinal tubules in a defined area was counted. RESULTS The control groups showed smooth surfaces with (bur plus acid etching) and without opened dentinal tubules (bur), whereas all laser-irradiated surfaces showed rough surfaces. Using the energy setting of 4 W resulted in significantly more opened dentinal tubules than the conventional preparation technique using the bur with additional acid etching. In contrast, the energy setting of 8 W showed significantly fewer opened dentinal tubules, and also exhibited signs of thermal damage. CONCLUSIONS The Er:YAG laser with an energy setting of 4 W generates a dentin surface with opened dentinal tubules, a prerequisite for adhesive fixation.
Resumo:
The aim of the study was to compare fissure sealant quality after mechanical conditioning of erbium-doped yttrium aluminium garnet (Er:YAG) laser or air abrasion prior to chemical conditioning of phosphoric acid etching or of a self-etch adhesive. Twenty-five permanent molars were initially divided into three groups: control group (n = 5), phosphoric acid etching; test group 1 (n = 10), air abrasion; and test group 2, (n = 10) Er:YAG laser. After mechanical conditioning, the test group teeth were sectioned buccolingually and the occlusal surface of one half tooth (equal to one sample) was acid etched, while a self-etch adhesive was applied on the other half. The fissure system of each sample was sealed, thermo-cycled and immersed in 5% methylene dye for 24 h. Each sample was sectioned buccolingually, and one slice was analysed microscopically. Using specialized software microleakage, unfilled margin, sealant failure and unfilled area proportions were calculated. A nonparametric ANOVA model was applied to compare the Er:YAG treatment with that of air abrasion and the self-etch adhesive with phosphoric acid (α = 0.05). Test groups were compared to the control group using Wilcoxon rank sum tests (α = 0.05). The control group displayed significantly lower microleakage but higher unfilled area proportions than the Er:YAG laser + self-etch adhesive group and displayed significantly higher unfilled margin and unfilled area proportions than the air-abrasion + self-etch adhesive group. There was no statistically significant difference in the quality of sealants applied in fissures treated with either Er:YAG laser or air abrasion prior to phosphoric acid etching, nor in the quality of sealants applied in fissures treated with either self-etch adhesive or phosphoric acid following Er:YAG or air-abrasion treatment.
Resumo:
Production of back contact solar cells requires holes generations on the wafers to keep both positive and negative contacts on the back side of the cell. This drilling process weakens the wafer mechanically due to the presence of the holes and the damage introduced during the process as microcracks. In this study, several chemical processes have been applied to drilled wafers in order to eliminate or reduce the damage generated during this fabrication step. The treatments analyzed are the followings: alkaline etching during 1, 3 and 5 minutes, acid etching for 2 and 4 minutes and texturisation. To determine mechanical strength of the samples a common mechanical study has been carried out testing the samples by the Ring on Ring bending test and obtaining the stress state in the moment of failure by FE simulation. Finally the results obtained for each treatment were fitted to a three parameter Weibull distribution
Resumo:
A celulose é o polímero natural renovável disponível em maior abundância atualmente. Por possuir estrutura semicristalina, é possível extrair seus domínios cristalinos através de procedimentos que ataquem sua fase amorfa, como a hidrólise ácida, obtendo-se assim partículas cristalinas chamadas nanopartículas de celulose (NCs). Estas nanopartículas têm atraído enorme interesse científico, uma vez que possuem propriedades mecânicas, como módulo de elasticidade e resistência à tração, semelhantes a várias cargas inorgânicas utilizadas na fabricação de compósitos. Além disso, possuem dimensões nanométricas, o que contribui para menor adição de carga à matriz polimérica, já que possuem maior área de superfície, quando comparadas às cargas micrométricas. Nanocompósitos formados pela adição destas cargas em matrizes poliméricas podem apresentar propriedades comerciais atraentes, como barreira a gases, melhores propriedades térmicas e baixa densidade, quando comparados aos compósitos tradicionais. Como se trata de uma carga com dimensões nanométricas, obtida de fontes renováveis, uma das principais áreas de interesse para aplicação deste reforço é em biopolímeros biodegradáveis. O poli(ácido lático) (PLA), é um exemplo de biopolímero com propriedades mecânicas, térmicas e de processamento superiores a de outros biopolímeros comerciais. No presente trabalho foram obtidas nanopartículas de celulose (NCs), por meio de hidrólise ácida, utilizando-se três métodos distintos, com o objetivo de estudar o método mais eficiente para a obtenção de NCs adequadas à aplicação em compósitos de PLA. Os Métodos I e II empregam extração das NCs por meio do H2SO4, diferenciando-se apenas pela neutralização, a qual envolve diálise ou neutralização com NaHCO3, respectivamente. No Método III a extração das NCs foi realizada com H3PO4. As NCs foram caracterizadas por diferentes técnicas, como difração de raios X (DRX), análise termogravimétrica (TG), espectroscopia vibracional de absorção no infravermelho (FTIR), microscopia eletrônica de transmissão (MET) e microscopia de força atômica (MFA). Os resultados de caracterização das NCs indicaram que, a partir de todos os métodos utilizados, há formação de nanocristais de celulose (NCCs), entretanto, apenas os NCCs obtidos pelos Métodos II e III apresentaram estabilidade térmica suficiente para serem empregados em compósitos preparados por adição da carga no polímero em estado fundido. A incorporação das NCs em matriz de PLA foi realizada em câmara de mistura, com posterior moldagem por prensagem a quente. Compósitos obtidos por adição de NCs obtidas pelo Método II foram caracterizados por calorimetria exploratória diferencial (DSC), análise termogravimétrica, microscopia óptica, análises reológicas e microscopia eletrônica de varredura (MEV). A adição de NCs, extraídas pelo Método II, em matriz de PLA afetou o processo de cristalização do polímero, o qual apresentou maior grau de cristalinidade. Além disso, a adição de 3% em massa de NCs no PLA foi suficiente para alterar seu comportamento reológico. Os resultados reológicos indicaram que a morfologia do compósito é, predominantemente, composta por uma dispersão homogênea e fina da carga na fase matriz. Micrografias obtidas por MEV corroboram os resultados reológicos, mostrando, predominantemente a presença de partículas de NC em escala nanométrica. Compósitos de PLA com NCs obtidas pelo Método III apresentaram aglomerados de partículas de NC em escala micro e milimétrica, ao longo da fase matriz, e não foram extensivamente caracterizados.