933 resultados para year four
Resumo:
This study evaluated the five-year clinical performance of ceramic inlays and onlays made with two systems: sintered Duceram (Dentsply-Degussa) and pressable IPS Empress (Ivoclar Vivadent). Eighty-six restorations were placed by a single operator in 35 patients with a median age of 33 years. The restorations were cemented with dual-cured resin cement (Variolink II, Ivoclar Vivadent) and Syntac Classic adhesive under rubber dam. The evaluations were conducted by two independent investigators at baseline, and at one, two, three, and five years using the modified United States Public Health Service (USPHS) criteria. At the five-year recall, 26 patients were evaluated (74.28%), totalling 62 (72.09%) restorations. Four IPS restorations were fractured, two restorations presented secondary caries (one from IPS and one from Duceram), and two restorations showed unacceptable defects at the restoration margin and needed replacement (one restoration from each ceramic system). A general success rate of 87% was recorded. The Fisher exact test revealed no significant difference between Duceram and IPS Empress ceramic systems for all aspects evaluated at different recall appointments (p>0.05). The McNemar chi-square test showed significant differences in relation to marginal discoloration, marginal integrity, and surface texture between the baseline and five-year recall for both systems (p<0.001), with an increased percentage of Bravo scores. However, few Charlie or Delta scores were attributed to these restorations. In conclusion, these two types of ceramic materials demonstrated acceptable clinical performance after five years
Resumo:
The aim of the study was to investigate the characteristics of infant development at four, eight and twelve months of age, as result of postpartum depression. The prevalence of Postpartum Depression - measured by the Edinburgh Postnatal Depression Scale - at four months after delivery was 30.3%; at eight months, 26.4%; and at 12 months, 25.0%. Chi-square tests were used to compare children of mothers with and without Postpartum Depression in relation to developmental milestones. It was found developmental delay in infants of mothers with Postpartum Depression in: two interactional indicators at four months, two motor indicators at eight months and one gross motor indicator at twelve months. However, children of mothers with Postpartum Depression showed better results in one fine motor and in two language items at 12 months. The results point to the necessity of considering external and internal factors of mother and infant in the study of the effects of maternal depression on child development.
Resumo:
AIM: To compare the 10-year peri-implant bone loss (BL) rate in periodontally compromised (PCP) and periodontally healthy patients (PHP) around two different implant systems supporting single-unit crowns. MATERIALS AND METHODS: In this retrospective, controlled study, the mean BL (mBL) rate around dental implants placed in four groups of 20 non-smokers was evaluated after a follow-up of 10 years. Two groups of patients treated for periodontitis (PCP) and two groups of PHP were created. For each category (PCP and PHP), two different types of implant had been selected. The mBL was calculated by subtracting the radiographic bone levels at the time of crown cementation from the bone levels at the 10-year follow-up. RESULTS: The mean age, mean full-mouth plaque and full-mouth bleeding scores and implant location were similar between the four groups. Implant survival rates ranged between 85% and 95%, without statistically significant differences (P>0.05) between groups. For both implant systems, PCP showed statistically significantly higher mBL rates and number of sites with BL> or =3 mm compared with PHP (P<0.0001). CONCLUSIONS: After 10 years, implants in PCP yielded lower survival rates and higher mean marginal BL rates compared with those of implants placed in PHP. These results were independent of the implant system used or the healing modality applied.
Resumo:
Three horses (age 17 - 23 years) were referred to the equine clinic of the University of Berne due to colic, fever, tachycardia and tachypnea. All horses showed pleural effusion. Clinical findings in 2 of the horses were highly suggestive of an intra-thoracic esophageal perforation. Severe septic pleuropneumonia without suspicion of an esophageal lesion was diagnosed in the 3rd horse. In addition, an 11 year old stallion was referred to the equine clinic for treatment of a presumptive large colon impaction. The horse was given laxatives after nasogastric intubation. Subsequent dramatic clinical deterioration and signs consistent with severe pleuropneumonia suggest that esophageal perforation had occurred when passing the nasogastric tube. All 4 horses were euthanized due to a poor prognosis. Esophageal perforation was diagnosed or confirmed post mortem in all cases. A hypertrophy of the tunica muscularis of the intra-thoracic esophagus was found in 3 of 4 horses.
Resumo:
Control of contagious bovine pleuropneumonia (CBPP), caused by Mycoplasma mycoides subsp. mycoides Small Colony (MmmSC), remains an important goal in Africa. Subunit vaccines triggering B and T-cell responses could represent a promising approach. To this aim, the T-cell immunogenicity of four MmmSC lipoproteins (LppA, LppB, LppC and LppQ), present in African strains and able to elicit humoral response, was evaluated. In vitro assays revealed that only LppA was recognized by lymph node lymphocytes taken from three cattle, 3 weeks after MmmSC exposure. Maintenance of the LppA-specific response, relying on CD4 T-cells and IFN gamma production, was then demonstrated 1 year after infection. LppA is thus an important target for the CD4 T-cells generated early after MmmSC infection and persisting in the lymph nodes of recovered cattle. Its role as a protective antigen and ability to in vivo trigger both arms of the host immune response remain to be evaluated.
Resumo:
A dynamic deterministic simulation model was developed to assess the impact of different putative control strategies on the seroprevalence of Neospora caninum in female Swiss dairy cattle. The model structure comprised compartments of "susceptible" and "infected" animals (SI-model) and the cattle population was divided into 12 age classes. A reference model (Model 1) was developed to simulate the current (status quo) situation (present seroprevalence in Switzerland 12%), taking into account available demographic and seroprevalence data of Switzerland. Model 1 was modified to represent four putative control strategies: testing and culling of seropositive animals (Model 2), discontinued breeding with offspring from seropositive cows (Model 3), chemotherapeutic treatment of calves from seropositive cows (Model 4), and vaccination of susceptible and infected animals (Model 5). Models 2-4 considered different sub-scenarios with regard to the frequency of diagnostic testing. Multivariable Monte Carlo sensitivity analysis was used to assess the impact of uncertainty in input parameters. A policy of annual testing and culling of all seropositive cattle in the population reduced the seroprevalence effectively and rapidly from 12% to <1% in the first year of simulation. The control strategies with discontinued breeding with offspring from all seropositive cows, chemotherapy of calves and vaccination of all cattle reduced the prevalence more slowly than culling but were still very effective (reduction of prevalence below 2% within 11, 23 and 3 years of simulation, respectively). However, sensitivity analyses revealed that the effectiveness of these strategies depended strongly on the quality of the input parameters used, such as the horizontal and vertical transmission factors, the sensitivity of the diagnostic test and the efficacy of medication and vaccination. Finally, all models confirmed that it was not possible to completely eradicate N. caninum as long as the horizontal transmission process was not interrupted.
Resumo:
PURPOSE: To report a case of bilateral central crystalline keratopathy in the anterior stroma occurring 4 years after Intacs implantation. METHODS: A 45-year-old woman underwent bilateral uncomplicated Intacs implantation for myopia. The postoperative course was uneventful. However, between 3 and 4 years after surgery, the patient developed central opacifications of the anterior stroma in both eyes, reducing best spectacle-corrected visual acuity. RESULTS: Intacs were explanted. Confocal microscopy, electron microscopy of the explanted ring segments, and microbiology studies were performed. Opacities were still detectable at the slit-lamp microscope up to 8 months after explantation. CONCLUSIONS: This is the first report on central corneal opacifications after Intacs implantation for myopia. The opacities could be the result of chronic metabolic stress or the beginning of lipid-like changes in another more central corneal localization.
Resumo:
The aim of this study was to assess the influence on the infrared laser fluorescence response of some storage methods commonly used in dental research. Forty extracted permanent teeth, selected from a pool of frozen teeth, were divided into four groups of 10. Three groups were stored at 4 degrees C in 1% chloramine, 10% formalin or 0.02% thymol solution. The fourth group was stored at -20 degrees C (no storage solution added). Fluorescence measurements were performed at 14, 77, 113, 168, 232, 486 and 737 days. After 2 years, significant decreases in fluorescence (p<0.01) for the samples in formalin (-60%), chloramine (-72%) and thymol (-54%) were observed. The frozen teeth showed a slight but non-significant increase in fluorescence of 5% (p>0.01). Storing solutions have a significant influence on the fluorescence yield. Samples used for in vitro purposes stored frozen do not significantly change their fluorescence response. Thus, cut-off values obtained under the latter conditions could be extrapolated to the in vivo situation.
Resumo:
OBJECTIVE: To assess the memory of various subdimensions of the birth experience in the second year postpartum, and to identify women in the first weeks postpartum at risk of developing a long-term negative memory. DESIGN, METHOD, OUTCOME MEASURES: New mothers' birth experience (BE) was assessed 48-96 hours postpartum (T1) by means of the SIL-Ger and the BBCI (perception of intranatal relationships); early postnatal adjustment (week 3 pp: T1(bis)) was also assessed. Then, four subgroups of women were defined by means of a cluster-analysis, integrating the T1/T1(bis) variables. To evaluate the memory of the BE, the SIL-Ger was again applied in the second year after childbirth (T2). First, the ratings of the SIL-Ger dimensions of T1 were compared to those at T2 in the whole sample. Then, the four subgroups were compared with respect to their ratings of the birth experience at T2 (correlations, ANOVAs and t-tests). RESULTS: In general, fulfillment, emotional adaptation, physical discomfort, and anxiety improve spontaneously over the first year postpartum, whereas in negative emotional experience, control, and time-going-slowly no shift over time is observed. However, women with a negative overall birth experience and a low level of perceived intranatal relationship at T1 run a high risk of retaining a negative memory in all of the seven subdimensions of the birth experience. CONCLUSIONS: Women at risk of developing a negative long-term memory of the BE can be identified at the time of early postpartum, when the overall birth experience and the perceived intranatal relationship are taken into account.
Resumo:
The new Swiss implant system SPI became available three years ago and is used in combination with fixed and removable prosthetic reconstructions. In a pilot study the clinical procedures were evaluated and data of prosthetic complications of maintenance service were collected. 25 patients participated in the study with a total of 79 SPI implants during the time period from 2003-2004. 37 implants were located in the maxilla and 42 implants in the mandible. Two implants failed during the healing period, but no loaded implant was lost. Thus, the survival rate was 97.5% (77/79). 44 implants supported a fixed prosthesis, including nine single crowns and 33 implants were used in combination with removable partial denture. Four implants were used with ball anchor retention, 29 with bar support. The ELEMENT implant with the low implant shoulder allows very good esthetics. Prosthetic complications and maintenance service during the first year of function was comparable with other implant systems. Since the design of the abutment screws, healing caps and screwdriver was changed, the system has become easier in its application.
Resumo:
Stem cells of various tissues are typically defined as multipotent cells with 'self-renewal' properties. Despite the increasing interest in stem cells, surprisingly little is known about the number of times stem cells can or do divide over a lifetime. Based on telomere-length measurements of hematopoietic cells, we previously proposed that the self-renewal capacity of hematopoietic stem cells is limited by progressive telomere attrition and that such cells divide very rapidly during the first year of life. Recent studies of patients with aplastic anemia resulting from inherited mutations in telomerase genes support the notion that the replicative potential of hematopoietic stem cells is directly related to telomere length, which is indirectly related to telomerase levels. To revisit conclusions about stem cell turnover based on cross-sectional studies of telomere length, we performed a longitudinal study of telomere length in leukocytes from newborn baboons. All four individual animals studied showed a rapid decline in telomere length (approximately 2-3 kb) in granulocytes and lymphocytes in the first year after birth. After 50-70 weeks the telomere length appeared to stabilize in all cell types. These observations suggest that hematopoietic stem cells, after an initial phase of rapid expansion, switch at around 1 year of age to a different functional mode characterized by a markedly decreased turnover rate.
Resumo:
A 20-year retrospective study of inhalant deaths in South Australia, autopsied at Forensic Science SA, was undertaken from January 1983 to December 2002. Thirty-nine cases were identified from an autopsy pool of 18,880 cases, with a male to female ratio of 12:1. Sixty-four percent of the victims (N = 25) died during voluntary inhalation of volatile substances and 28% (N = 11) committed suicide utilizing a volatile substance or gas. The remaining 3 cases involved a workplace accident (N = 1) and 2 cases of autoerotic death where inhalants were being used to augment solitary sexual activity. The mean age of the 28 victims of accidental inhalant death of 21 years (range, 13-45 years) was considerably less than that of the 11 suicide victims of 31.5 years (range, 17-48 years). No homicides were found. Approximately one quarter of the victims were Aboriginal (N = 11), 10 of whom had died as a result of gasoline inhalation ("petrol sniffing"). Other common substances of abuse were aliphatic hydrocarbons such as butane. The study has shown that those most at risk for accidental or suicidal inhalant deaths were young males, with 92% of victims overall being male, and with 77% of victims being under 31 years of age. Gasoline inhalation remains a significant problem in Aboriginal communities in South Australia.
Resumo:
AIMS: To assess the impact of different implant systems on the clinical conditions and the microbiota at implants, and whether the presence of bacteria at tooth sites was predictive of the presence at implant sites. MATERIALS AND METHODS: Subjects with either AstraTech or Brånemark in function for 7 years were enrolled. Sub-gingival bacterial samples at tooth and implant sites were collected with sterile endodontic paper points, and analyzed by the checkerboard DNA-DNA hybridization method (40 species). RESULTS: Fifty-four subjects, 27 supplied with AstraTech (n=132 implants) and 27 with Brånemark (n=102) implants, were studied. Test tooth sites had significantly less evidence of bleeding on probing (P<0.001) and presence of plaque (P<0.001) than implant test sites. Implant sites presented with deeper probing pocket depth than tooth sites (mean difference: 1.1 mm, standard error of differences: 0.08, 95% confidence intervals (CI): 0.9-1.3, P<0.001). Tannerella forsythia (P<0.05), Capnocytophaga sputigena (P<0.05), Actinomyces israelii (P<0.05) and Lactobacillus acidophilus (P<0.05) were found at higher levels at tooth surfaces. No differences in bacterial load for any species were found between the two implant systems. The odds of being present/absent at tooth and implants sites were only significant for Staphylococcus aureus [odds ratio (OR): 5.2 : 1, 95% CI: 1.4-18.9, P<0.01]. CONCLUSIONS: After 7 years in function, implants presented with deeper probing depths than teeth. S. aureus was commonly present at both teeth and implants sites. S. aureus at tooth sites was predictive of also being present at implant sites.
Resumo:
PURPOSE: To compare objective fellow and expert efficiency indices for an interventional radiology renal artery stenosis skill set with the use of a high-fidelity simulator. MATERIALS AND METHODS: The Mentice VIST simulator was used for three different renal artery stenosis simulations of varying difficulty, which were used to grade performance. Fellows' indices at three intervals throughout 1 year were compared to expert baseline performance. Seventy-four simulated procedures were performed, 63 of which were captured as audiovisual recordings. Three levels of fellow experience were analyzed: 1, 6, and 12 months of dedicated interventional radiology fellowship. The recordings were compiled on a computer workstation and analyzed. Distinct measurable events in the procedures were identified with task analysis, and data regarding efficiency were extracted. Total scores were calculated as the product of procedure time, fluoroscopy time, tools, and contrast agent volume. The lowest scores, which reflected efficient use of tools, radiation, and time, were considered to indicate proficiency. Subjective analysis of participants' procedural errors was not included in this analysis. RESULTS: Fellows' mean scores diminished from 1 month to 12 months (42,960 at 1 month, 18,726 at 6 months, and 9,636 at 12 months). The experts' mean score was 4,660. In addition, the range of variance in score diminished with increasing experience (from a range of 5,940-120,156 at 1 month to 2,436-85,272 at 6 months and 2,160-32,400 at 12 months). Expert scores ranged from 1,450 to 10,800. CONCLUSIONS: Objective efficiency indices for simulated procedures can demonstrate scores directly comparable to the level of clinical experience.
Resumo:
OBJECTIVES: The aim of the present split-mouth study is to assess the peri-implant conditions around early-loaded sandblasted and acid-etched (SLA) implants, 5 years after abutment connection and to compare, in the same patients, the results obtained with a standard protocol using identical implants with a TPS surface. MATERIAL AND METHODS: Surgical procedure was performed by the same operator and was identical at test (SLA) and control (TPS) sites, in 32 healthy patients. Abutment connection was carried out at 35 N cm 6 weeks postsurgery for test sites and 12 weeks for the controls. Patients were seen regularly, for control and professional cleaning. At 60 months, clinical measures and radiographic bone changes were recorded by the same operator, blind to the type of surface of the implant, on 27 patients, as five patients were lost to follow-up. RESULTS: A total number of 106 implants were examined. No implant was lost. No significant differences were found with respect to the presence of plaque [modified plaque index (mPI) 0.27+/-0.56 vs. 0.32+/-0.54], bleeding on probing (29% vs. 32%), mean pocket depth (3.2+/-1 vs. 3.2+/-1 mm) or mean marginal bone loss (0.32+/-1.04 vs. 0.44+/-1.12 mm) between test and control. Four implants that presented 'spinning' at the time of abutment connection presented no significant differences from the rest of the test sites. CONCLUSION: The results of this prospective study confirm that SLA implants, under defined conditions, are suitable for early loading at 6 weeks in both the mandible and the maxilla. Limited implant spinning, occasionally found at abutment connection, produces no detrimental effect on the clinical outcome when properly handled.