965 resultados para video-assisted thoracoscopic surgery (VATS)


Relevância:

30.00% 30.00%

Publicador:

Resumo:

CONTEXT Robot-assisted surgery is increasingly used for radical cystectomy (RC) and urinary reconstruction. Sufficient data have accumulated to allow evidence-based consensus on key issues such as perioperative management, comparative effectiveness on surgical complications, and oncologic short- to midterm outcomes. OBJECTIVE A 2-d conference of experts on RC and urinary reconstruction was organized in Pasadena, California, and the City of Hope Cancer Center in Duarte, California, to systematically review existing peer-reviewed literature on robot-assisted RC (RARC), extended lymphadenectomy, and urinary reconstruction. No commercial support was obtained for the conference. EVIDENCE ACQUISITION A systematic review of the literature was performed in agreement with the PRISMA statement. EVIDENCE SYNTHESIS Systematic literature reviews and individual presentations were discussed, and consensus on all key issues was obtained. Most operative, intermediate-term oncologic, functional, and complication outcomes are similar between open RC (ORC) and RARC. RARC consistently results in less blood loss and a reduced need for transfusion during surgery. RARC generally requires longer operative time than ORC, particularly with intracorporeal reconstruction. Robotic assistance provides ergonomic value for surgeons. Surgeon experience and institutional volume strongly predict favorable outcomes for either open or robotic techniques. CONCLUSIONS RARC appears to be similar to ORC in terms of operative, pathologic, intermediate-term oncologic, complication, and most functional outcomes. RARC consistently results in less blood loss and a reduced need for transfusion during surgery. RARC can be more expensive than ORC, although high procedural volume may attenuate this difference. PATIENT SUMMARY Robot-assisted radical cystectomy (RARC) is an alternative to open surgery for patients with bladder cancer who require removal of their bladder and reconstruction of their urinary tract. RARC appears to be similar to open surgery for most important outcomes such as the rate of complications and intermediate-term cancer-specific survival. Although RARC has some ergonomic advantages for surgeons and may result in less blood loss during surgery, it is more time consuming and may be more expensive than open surgery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECT In ventriculoperitoneal (VP) shunt surgery, laparoscopic assistance can be used for placement of the peritoneal catheter. Until now, the efficacy of laparoscopic shunt placement has been investigated only in retrospective and nonrandomized prospective studies, which have reported decreased distal shunt dysfunction rates in patients undergoing laparascopic placement compared with mini-laparotomy cohorts. In this randomized controlled trial the authors compared rates of shunt failure in patients who underwent laparoscopic surgery for peritoneal catheter placement with rates in patients who underwent traditional mini-laparotomy. METHODS One hundred twenty patients scheduled for VP shunt surgery were randomized to laparoscopic surgery or mini-laparotomy for insertion of the peritoneal catheter. The primary endpoint was the rate of overall shunt complication or failure within the first 12 months after surgery. Secondary endpoints were distal shunt failure, overall complication/ failure, duration of surgery and hospitalization, and morbidity. RESULTS The overall shunt complication/failure rate was 15% (9 of 60 cases) in the laparoscopic group and 18.3% (11 of 60 cases) in the mini-laparotomy group (p = 0.404). Patients in the laparoscopic group had no distal shunt failures; in contrast, 5 (8%) of 60 patients in the mini-laparotomy group experienced distal shunt failure (p = 0.029). Intraoperative complications occurred in 2 patients (both in the laparoscopic group), and abdominal pain led to catheter removal in 1 patient per group. Infections occurred in 1 patient in the laparoscopic group and 3 in the mini-laparotomy group. The mean durations of surgery and hospitalization were similar in the 2 groups. CONCLUSIONS While overall shunt failure rates were similar in the 2 groups, the use of laparoscopic shunt placement significantly reduced the rate of distal shunt failure compared with mini-laparotomy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

HYPOTHESIS To evaluate the feasibility and the results of insertion of two types of electrode arrays in a robotically assisted surgical approach. BACKGROUND Recent publications demonstrated that robot-assisted surgery allows the implantation of free-fitting electrode arrays through a cochleostomy drilled via a narrow bony tunnel (DCA). We investigated if electrode arrays from different manufacturers could be used with this approach. METHODS Cone-beam CT imaging was performed on fivecadaveric heads after placement of fiducial screws. Relevant anatomical structures were segmented and the DCA trajectory, including the position of the cochleostomy, was defined to target the center of the scala tympani while reducing the risk of lesions to the facial nerve. Med-El Flex 28 and Cochlear CI422 electrodes were implanted on both sides, and their position was verified by cone-beam CT. Finally, temporal bones were dissected to assess the occurrence of damage to anatomical structures during DCA drilling. RESULTS The cochleostomy site was directed in the scala tympani in 9 of 10 cases. The insertion of electrode arrays was successful in 19 of 20 attempts. No facial nerve damage was observed. The average difference between the planned and the postoperative trajectory was 0.17 ± 0.19 mm at the level of the facial nerve. The average depth of insertion was 305.5 ± 55.2 and 243 ± 32.1 degrees with Med-El and Cochlear arrays, respectively. CONCLUSIONS Robot-assisted surgery is a reliable tool to allow cochlear implantation through a cochleostomy. Technical solutions must be developed to improve the electrode array insertion using this approach.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a case of successful interventional laser-assisted extraction of an endovascularly trapped long-term implanted ventriculoatrial shunt in a patient with shunt-associated septicemia. This approach is based on modified techniques for explantation of pacemaker leads and might be considered an additional option for extraction of otherwise nonremovable trapped endovascular catheters in experienced centers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE To evaluate a low-cost, inertial sensor-based surgical navigation solution for periacetabular osteotomy (PAO) surgery without the line-of-sight impediment. METHODS Two commercial inertial measurement units (IMU, Xsens Technologies, The Netherlands), are attached to a patient's pelvis and to the acetabular fragment, respectively. Registration of the patient with a pre-operatively acquired computer model is done by recording the orientation of the patient's anterior pelvic plane (APP) using one IMU. A custom-designed device is used to record the orientation of the APP in the reference coordinate system of the IMU. After registration, the two sensors are mounted to the patient's pelvis and acetabular fragment, respectively. Once the initial position is recorded, the orientation is measured and displayed on a computer screen. A patient-specific computer model generated from a pre-operatively acquired computed tomography scan is used to visualize the updated orientation of the acetabular fragment. RESULTS Experiments with plastic bones (eight hip joints) performed in an operating room comparing a previously developed optical navigation system with our inertial-based navigation system showed no statistically significant difference on the measurement of acetabular component reorientation. In all eight hip joints the mean absolute difference was below four degrees. CONCLUSION Using two commercially available inertial measurement units we show that it is possible to accurately measure the orientation (inclination and anteversion) of the acetabular fragment during PAO surgery and therefore to successfully eliminate the line-of-sight impediment that optical navigation systems have.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

CONTEXT Enhanced Recovery after Surgery (ERAS) programs are multimodal care pathways that aim to decrease intra-operative blood loss, decrease postoperative complications, and reduce recovery times. OBJECTIVE To overview the use and key elements of ERAS pathways, and define needs for future clinical trials. EVIDENCE ACQUISITION A comprehensive systematic MEDLINE search was performed for English language reports published before May 2015 using the terms "postoperative period," "postoperative care," "enhanced recovery after surgery," "enhanced recovery," "accelerated recovery," "fast track recovery," "recovery program," "recovery pathway", "ERAS," and "urology" or "cystectomy" or "urologic surgery." EVIDENCE SYNTHESIS We identified 18 eligible articles. Patient counseling, physical conditioning, avoiding excessive alcohol and smoking, and good nutrition appeared to protect against postoperative complications. Fasting from solid food for only 6h and perioperative liquid-carbohydrate loading up to 2h prior to surgery appeared to be safe and reduced recovery times. Restricted, balanced, and goal-directed fluid replacement is effective when individualized, depending on patient morbidity and surgical procedure. Decreased intraoperative blood loss may be achieved by several measures. Deep vein thrombosis prophylaxis, antibiotic prophylaxis, and thermoregulation were found to help reduce postsurgical complications, as was a multimodal approach to postoperative nausea, vomiting, and analgesia. Chewing gum, prokinetic agents, oral laxatives, and an early resumption to normal diet appear to aid faster return to normal bowel function. Further studies should compare anesthetic protocols, refine analgesia, and evaluate the importance of robot-assisted surgery and the need/timing for drains and catheters. CONCLUSIONS ERAS regimens are multidisciplinary, multimodal pathways that optimize postoperative recovery. PATIENT SUMMARY This review provides an overview of the use and key elements of Enhanced Recovery after Surgery programs, which are multimodal, multidisciplinary care pathways that aim to optimize postoperative recovery. Additional conclusions include identifying effective procedures within Enhanced Recovery after Surgery programs and defining needs for future clinical trials.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Las técnicas de cirugía de mínima invasión (CMI) se están consolidando hoy en día como alternativa a la cirugía tradicional, debido a sus numerosos beneficios para los pacientes. Este cambio de paradigma implica que los cirujanos deben aprender una serie de habilidades distintas de aquellas requeridas en cirugía abierta. El entrenamiento y evaluación de estas habilidades se ha convertido en una de las mayores preocupaciones en los programas de formación de cirujanos, debido en gran parte a la presión de una sociedad que exige cirujanos bien preparados y una reducción en el número de errores médicos. Por tanto, se está prestando especial atención a la definición de nuevos programas que permitan el entrenamiento y la evaluación de las habilidades psicomotoras en entornos seguros antes de que los nuevos cirujanos puedan operar sobre pacientes reales. Para tal fin, hospitales y centros de formación están gradualmente incorporando instalaciones de entrenamiento donde los residentes puedan practicar y aprender sin riesgos. Es cada vez más común que estos laboratorios dispongan de simuladores virtuales o simuladores físicos capaces de registrar los movimientos del instrumental de cada residente. Estos simuladores ofrecen una gran variedad de tareas de entrenamiento y evaluación, así como la posibilidad de obtener información objetiva de los ejercicios. Los diferentes estudios de validación llevados a cabo dan muestra de su utilidad; pese a todo, los niveles de evidencia presentados son en muchas ocasiones insuficientes. Lo que es más importante, no existe un consenso claro a la hora de definir qué métricas son más útiles para caracterizar la pericia quirúrgica. El objetivo de esta tesis doctoral es diseñar y validar un marco de trabajo conceptual para la definición y validación de entornos para la evaluación de habilidades en CMI, en base a un modelo en tres fases: pedagógica (tareas y métricas a emplear), tecnológica (tecnologías de adquisición de métricas) y analítica (interpretación de la competencia en base a las métricas). Para tal fin, se describe la implementación práctica de un entorno basado en (1) un sistema de seguimiento de instrumental fundamentado en el análisis del vídeo laparoscópico; y (2) la determinación de la pericia en base a métricas de movimiento del instrumental. Para la fase pedagógica se diseñó e implementó un conjunto de tareas para la evaluación de habilidades psicomotoras básicas, así como una serie de métricas de movimiento. La validación de construcción llevada a cabo sobre ellas mostró buenos resultados para tiempo, camino recorrido, profundidad, velocidad media, aceleración media, economía de área y economía de volumen. Adicionalmente, los resultados obtenidos en la validación de apariencia fueron en general positivos en todos los grupos considerados (noveles, residentes, expertos). Para la fase tecnológica, se introdujo el EVA Tracking System, una solución para el seguimiento del instrumental quirúrgico basado en el análisis del vídeo endoscópico. La precisión del sistema se evaluó a 16,33ppRMS para el seguimiento 2D de la herramienta en la imagen; y a 13mmRMS para el seguimiento espacial de la misma. La validación de construcción con una de las tareas de evaluación mostró buenos resultados para tiempo, camino recorrido, profundidad, velocidad media, aceleración media, economía de área y economía de volumen. La validación concurrente con el TrEndo® Tracking System por su parte presentó valores altos de correlación para 8 de las 9 métricas analizadas. Finalmente, para la fase analítica se comparó el comportamiento de tres clasificadores supervisados a la hora de determinar automáticamente la pericia quirúrgica en base a la información de movimiento del instrumental, basados en aproximaciones lineales (análisis lineal discriminante, LDA), no lineales (máquinas de soporte vectorial, SVM) y difusas (sistemas adaptativos de inferencia neurodifusa, ANFIS). Los resultados muestran que en media SVM presenta un comportamiento ligeramente superior: 78,2% frente a los 71% y 71,7% obtenidos por ANFIS y LDA respectivamente. Sin embargo las diferencias estadísticas medidas entre los tres no fueron demostradas significativas. En general, esta tesis doctoral corrobora las hipótesis de investigación postuladas relativas a la definición de sistemas de evaluación de habilidades para cirugía de mínima invasión, a la utilidad del análisis de vídeo como fuente de información y a la importancia de la información de movimiento de instrumental a la hora de caracterizar la pericia quirúrgica. Basándose en estos cimientos, se han de abrir nuevos campos de investigación que contribuyan a la definición de programas de formación estructurados y objetivos, que puedan garantizar la acreditación de cirujanos sobradamente preparados y promocionen la seguridad del paciente en el quirófano. Abstract Minimally invasive surgery (MIS) techniques have become a standard in many surgical sub-specialties, due to their many benefits for patients. However, this shift in paradigm implies that surgeons must acquire a complete different set of skills than those normally attributed to open surgery. Training and assessment of these skills has become a major concern in surgical learning programmes, especially considering the social demand for better-prepared professionals and for the decrease of medical errors. Therefore, much effort is being put in the definition of structured MIS learning programmes, where practice with real patients in the operating room (OR) can be delayed until the resident can attest for a minimum level of psychomotor competence. To this end, skills’ laboratory settings are being introduced in hospitals and training centres where residents may practice and be assessed on their psychomotor skills. Technological advances in the field of tracking technologies and virtual reality (VR) have enabled the creation of new learning systems such as VR simulators or enhanced box trainers. These systems offer a wide range of tasks, as well as the capability of registering objective data on the trainees’ performance. Validation studies give proof of their usefulness; however, levels of evidence reported are in many cases low. More importantly, there is still no clear consensus on topics such as the optimal metrics that must be used to assess competence, the validity of VR simulation, the portability of tracking technologies into real surgeries (for advanced assessment) or the degree to which the skills measured and obtained in laboratory environments transfer to the OR. The purpose of this PhD is to design and validate a conceptual framework for the definition and validation of MIS assessment environments based on a three-pillared model defining three main stages: pedagogical (tasks and metrics to employ), technological (metric acquisition technologies) and analytical (interpretation of competence based on metrics). To this end, a practical implementation of the framework is presented, focused on (1) a video-based tracking system and (2) the determination of surgical competence based on the laparoscopic instruments’ motionrelated data. The pedagogical stage’s results led to the design and implementation of a set of basic tasks for MIS psychomotor skills’ assessment, as well as the definition of motion analysis parameters (MAPs) to measure performance on said tasks. Validation yielded good construct results for parameters such as time, path length, depth, average speed, average acceleration, economy of area and economy of volume. Additionally, face validation results showed positive acceptance on behalf of the experts, residents and novices. For the technological stage the EVA Tracking System is introduced. EVA provides a solution for tracking laparoscopic instruments from the analysis of the monoscopic video image. Accuracy tests for the system are presented, which yielded an average RMSE of 16.33pp for 2D tracking of the instrument on the image and of 13mm for 3D spatial tracking. A validation experiment was conducted using one of the tasks and the most relevant MAPs. Construct validation showed significant differences for time, path length, depth, average speed, average acceleration, economy of area and economy of volume; especially between novices and residents/experts. More importantly, concurrent validation with the TrEndo® Tracking System presented high correlation values (>0.7) for 8 of the 9 MAPs proposed. Finally, the analytical stage allowed comparing the performance of three different supervised classification strategies in the determination of surgical competence based on motion-related information. The three classifiers were based on linear (linear discriminant analysis, LDA), non-linear (support vector machines, SVM) and fuzzy (adaptive neuro fuzzy inference systems, ANFIS) approaches. Results for SVM show slightly better performance than the other two classifiers: on average, accuracy for LDA, SVM and ANFIS was of 71.7%, 78.2% and 71% respectively. However, when confronted, no statistical significance was found between any of the three. Overall, this PhD corroborates the investigated research hypotheses regarding the definition of MIS assessment systems, the use of endoscopic video analysis as the main source of information and the relevance of motion analysis in the determination of surgical competence. New research fields in the training and assessment of MIS surgeons can be proposed based on these foundations, in order to contribute to the definition of structured and objective learning programmes that guarantee the accreditation of well-prepared professionals and the promotion of patient safety in the OR.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: The EVA (Endoscopic Video Analysis) tracking system a new tracking system for extracting motions of laparoscopic instruments based on non-obtrusive video tracking was developed. The feasibility of using EVA in laparoscopic settings has been tested in a box trainer setup. METHODS: EVA makes use of an algorithm that employs information of the laparoscopic instrument's shaft edges in the image, the instrument's insertion point, and the camera's optical centre to track the 3D position of the instrument tip. A validation study of EVA comprised a comparison of the measurements achieved with EVA and the TrEndo tracking system. To this end, 42 participants (16 novices, 22 residents, and 4 experts) were asked to perform a peg transfer task in a box trainer. Ten motion-based metrics were used to assess their performance. RESULTS: Construct validation of the EVA has been obtained for seven motion-based metrics. Concurrent validation revealed that there is a strong correlation between the results obtained by EVA and the TrEndo for metrics such as path length (p=0,97), average speed (p=0,94) or economy of volume (p=0,85), proving the viability of EVA. CONCLUSIONS: EVA has been successfully used in the training setup showing potential of endoscopic video analysis to assess laparoscopic psychomotor skills. The results encourage further implementation of video tracking in training setups and in image guided surgery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Cognitive skills training for minimally invasive surgery has traditionally relied upon diverse tools, such as seminars or lectures. Web technologies for e-learning have been adopted to provide ubiquitous training and serve as structured repositories for the vast amount of laparoscopic video sources available. However, these technologies fail to offer such features as formative and summative evaluation, guided learning, or collaborative interaction between users. Methodology: The "TELMA" environment is presented as a new technology-enhanced learning platform that increases the user's experience using a four-pillared architecture: (1) an authoring tool for the creation of didactic contents; (2) a learning content and knowledge management system that incorporates a modular and scalable system to capture, catalogue, search, and retrieve multimedia content; (3) an evaluation module that provides learning feedback to users; and (4) a professional network for collaborative learning between users. Face validation of the environment and the authoring tool are presented. Results: Face validation of TELMA reveals the positive perception of surgeons regarding the implementation of TELMA and their willingness to use it as a cognitive skills training tool. Preliminary validation data also reflect the importance of providing an easy-to-use, functional authoring tool to create didactic content. Conclusion: The TELMA environment is currently installed and used at the Jesús Usón Minimally Invasive Surgery Centre and several other Spanish hospitals. Face validation results ascertain the acceptance and usefulness of this new minimally invasive surgery training environment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Laparoscopic instrument tracking systems are an essential component in image-guided interventions and offer new possibilities to improve and automate objective assessment methods of surgical skills. In this study we present our system design to apply a third generation optical pose tracker (Micron- Tracker®) to laparoscopic practice. A technical evaluation of this design is performed in order to analyze its accuracy in computing the laparoscopic instrument tip position. Results show a stable fluctuation error over the entire analyzed workspace. The relative position errors are 1.776±1.675 mm, 1.817±1.762 mm, 1.854±1.740 mm, 2.455±2.164 mm, 2.545±2.496 mm, 2.764±2.342 mm, 2.512±2.493 mm for distances of 50, 100, 150, 200, 250, 300, and 350 mm, respectively. The accumulated distance error increases with the measured distance. The instrument inclination covered by the system is high, from 90 to 7.5 degrees. The system reports a low positional accuracy for the instrument tip.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Video on Demand (VoD) service is becoming a dominant service in the telecommunication market due to the great convenience regarding the choice of content items and their independent viewing time. However, it comes with the downsides of high server storage and capacity demands because of the large variety of content items and the high amount of traffic generated for serving all requests. Storing part of the popular contents on the peers brings certain advantages but, it still has issues regarding the overall traffic in the core of the network and the scalability. Therefore, we propose a P2P assisted model for streaming VoD contents that takes advantage of the clients unused uplink and storage capacity to serve requests of other clients and we present popularity based schemes for distribution of both the popular and unpopular contents on the peers. The proposed model and the schemes prove to reduce the streaming traffic in the core of the network, improve the responsiveness of the system and increase its scalability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Video on Demand (VoD) service is becoming a dominant service in the telecommunication market due to the great convenience regarding the choice of content items and their independent viewing time. However, due to its high traffic demand nature, the VoD streaming systems are faced with the problem of huge amounts of traffic generated in the core of the network, especially for serving the requests for content items that are not in the top popularity range. Therefore, we propose a peer assisted VoD model that takes advantage of the clients unused uplink and storage capacity to serve requests for less popular items with the objective to keep the traffic on the periphery of the network, reduce the transport cost in the core of the network and make the system more scalable.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

La demanda de contenidos de vídeo ha aumentado rápidamente en los últimos años como resultado del gran despliegue de la TV sobre IP (IPTV) y la variedad de servicios ofrecidos por los operadores de red. Uno de los servicios que se ha vuelto especialmente atractivo para los clientes es el vídeo bajo demanda (VoD) en tiempo real, ya que ofrece una transmisión (streaming) inmediata de gran variedad de contenidos de vídeo. El precio que los operadores tienen que pagar por este servicio es el aumento del tráfico en las redes, que están cada vez más congestionadas debido a la mayor demanda de contenidos de VoD y al aumento de la calidad de los propios contenidos de vídeo. Así, uno de los principales objetivos de esta tesis es encontrar soluciones que reduzcan el tráfico en el núcleo de la red, manteniendo la calidad del servicio en el nivel adecuado y reduciendo el coste del tráfico. La tesis propone un sistema jerárquico de servidores de streaming en el que se ejecuta un algoritmo para la ubicación óptima de los contenidos de acuerdo con el comportamiento de los usuarios y el estado de la red. Debido a que cualquier algoritmo óptimo de distribución de contenidos alcanza un límite en el que no se puede llegar a nuevas mejoras, la inclusión de los propios clientes del servicio (los peers) en el proceso de streaming puede reducir aún más el tráfico de red. Este proceso se logra aprovechando el control que el operador tiene en las redes de gestión privada sobre los equipos receptores (Set-Top Box) ubicados en las instalaciones de los clientes. El operador se reserva cierta capacidad de almacenamiento y streaming de los peers para almacenar los contenidos de vídeo y para transmitirlos a otros clientes con el fin de aliviar a los servidores de streaming. Debido a la incapacidad de los peers para sustituir completamente a los servidores de streaming, la tesis propone un sistema de streaming asistido por peers. Algunas de las cuestiones importantes que se abordan en la tesis son saber cómo los parámetros del sistema y las distintas distribuciones de los contenidos de vídeo en los peers afectan al rendimiento general del sistema. Para dar respuesta a estas preguntas, la tesis propone un modelo estocástico preciso y flexible que tiene en cuenta parámetros como las capacidades de enlace de subida y de almacenamiento de los peers, el número de peers, el tamaño de la biblioteca de contenidos de vídeo, el tamaño de los contenidos y el esquema de distribución de contenidos para estimar los beneficios del streaming asistido por los peers. El trabajo también propone una versión extendida del modelo matemático mediante la inclusión de la probabilidad de fallo de los peers y su tiempo de recuperación en el conjunto de parámetros del modelo. Estos modelos se utilizan como una herramienta para la realización de exhaustivos análisis del sistema de streaming de VoD asistido por los peers para la amplia gama de parámetros definidos en los modelos. Abstract The demand of video contents has rapidly increased in the past years as a result of the wide deployment of IPTV and the variety of services offered by the network operators. One of the services that has especially become attractive to the customers is real-time Video on Demand (VoD) because it offers an immediate streaming of a large variety of video contents. The price that the operators have to pay for this convenience is the increased traffic in the networks, which are becoming more congested due to the higher demand for VoD contents and the increased quality of the videos. Therefore, one of the main objectives of this thesis is finding solutions that would reduce the traffic in the core of the network, keeping the quality of service on satisfactory level and reducing the traffic cost. The thesis proposes a system of hierarchical structure of streaming servers that runs an algorithm for optimal placement of the contents according to the users’ behavior and the state of the network. Since any algorithm for optimal content distribution reaches a limit upon which no further improvements can be made, including service customers themselves (the peers) in the streaming process can further reduce the network traffic. This process is achieved by taking advantage of the control that the operator has in the privately managed networks over the Set-Top Boxes placed at the clients’ premises. The operator reserves certain storage and streaming capacity on the peers to store the video contents and to stream them to the other clients in order to alleviate the streaming servers. Because of the inability of the peers to completely substitute the streaming servers, the thesis proposes a system for peer-assisted streaming. Some of the important questions addressed in the thesis are how the system parameters and the various distributions of the video contents on the peers would impact the overall system performance. In order to give answers to these questions, the thesis proposes a precise and flexible stochastic model that takes into consideration parameters like uplink and storage capacity of the peers, number of peers, size of the video content library, size of contents and content distribution scheme to estimate the benefits of the peer-assisted streaming. The work also proposes an extended version of the mathematical model by including the failure probability of the peers and their recovery time in the set of parameters. These models are used as tools for conducting thorough analyses of the peer-assisted system for VoD streaming for the wide range of defined parameters.