947 resultados para time pressure
Resumo:
In order to understand how unburned hydrocarbons emerge from SI engines and, in particular, how non-fuel hydrocarbons are formed and oxidized, a new gas sampling technique has been developed. A sampling unit, based on a combination of techniques used in the Fast Flame Ionization Detector (FFID) and wall-mounted sampling valves, was designed and built to capture a sample of exhaust gas during a specific period of the exhaust process and from a specific location within the exhaust port. The sampling unit consists of a transfer tube with one end in the exhaust port and the other connected to a three-way valve that leads, on one side, to a FFID and, on the other, to a vacuum chamber with a high-speed solenoid valve. Exhaust gas, drawn by the pressure drop into the vacuum chamber, impinges on the face of the solenoid valve and flows radially outward. Once per cycle during a specified crank angle interval, the solenoid valve opens and traps exhaust gas in a storage unit, from which gas chromatography (GC) measurements are made. The port end of the transfer tube can be moved to different locations longitudinally or radially, thus allowing spatial resolution and capturing any concentration differences between port walls and the center of the flow stream. Further, the solenoid valve's opening and closing times can be adjusted to allow sampling over a window as small as 0.6 ms during any portion of the cycle, allowing resolution of a crank angle interval as small as 15°CA. Cycle averaged total HC concentration measured by the FFID and that measured by the sampling unit are in good agreement, while the sampling unit goes one step further than the FFID by providing species concentrations. Comparison with previous measurements using wall-mounted sampling valves suggests that this sampling unit is fully capable of providing species concentration information as a function of air/fuel ratio, load, and engine speed at specific crank angles. © Copyright 1996 Society of Automotive Engineers, Inc.
Resumo:
A laboratory-based methodology to launch cylindrical sand slugs at high velocities is developed. The methodology generates well-characterised soil ejecta without the need for detonation of an explosive; this laboratory-based tool thereby allows for the experimental investigation of the soil-structure events. The experimental set-up comprises a launcher with a cylindrical cavity and a piston to push out the sand slug. The apparatus is used to launch both dry and water-saturated sand slugs. High speed photography is used to characterise the evolution of the sand slugs after launch. We find that the diameter of the slugs remains unchanged, and the sand particles possess only an axial component of velocity. However, the sand particles have a uniform spatial gradient of axial velocity and this results in lengthening of the slugs as they travel towards their target. Thus, the density of the sand slugs remains spatially homogenous but decreases with increasing time. The velocity gradient is typically higher in the dry sand slugs than that of the water-saturated slugs. The pressure exerted by the slugs on a rigid-stationary target is measured by impacting the slugs against a direct impact Kolsky bar. After an initial high transient pressure, the pressure reduces to a value of approximately ρv 2 where ρ is the density of the impacting sand slug and v is the particle velocity. This indicates that loading due to the sand is primarily inertial in nature. The momentum transmitted to the Kolsky bar was approximately equal to the incident momentum of the sand slugs, regardless of whether they are dry or water-saturated. © 2013 Elsevier Ltd. All rights reserved.
Resumo:
The transition of a separated shear layer over a flat plate, in the presence of periodic wakes and elevated free-stream turbulence (FST), is numerically investigated using Large Eddy Simulation (LES). The upper wall of the test section is inviscid and specifically contoured to impose a streamwise pressure distribution over the flat plate to simulate the suction surface of a low-pressure turbine (LPT) blade. Two different distributions representative of a 'high-lift' and an 'ultra high-lift' turbine blade are examined. Results obtained from the current LES compare favourably with the extensive experimental data previously obtained for these configurations. The LES results are then used to further investigate the flow physics involved in the transition process.In line with experimental experience, the benefit of wakes and FST obtained by suppressing the separation bubble, is more pronounced in 'ultra high-lift' design when compared to the 'high-lift' design. Stronger 'Klebanoff streaks' are formed in the presence of wakes when compared to the streaks due to FST alone. These streaks promoted much early transition. The weak Klebanoff streaks due to FST continued to trigger transition in between the wake passing cycles.The experimental inference regarding the origin of Klebanoff streaks at the leading edge has been confirmed by the current simulations. While the wake convects at local free-stream velocity, its impression in the boundary layer in the form of streaks convects much slowly. The 'part-span' Kelvin-Helmholtz structures, which were observed in the experiments when the wake passes over the separation bubble, are also captured. The non-phase averaged space-time plots manifest that reattachment is a localized process across the span unlike the impression of global reattachment portrayed by phase averaging. © 2013 Elsevier Inc.
Resumo:
In steam power plants condensation already starts in the flow path of the low pressure part of the steam turbine, which leads to a complex three-dimensional two-phase flow. Wetness losses are caused due to thermodynamic and mechanical relaxation processes during condensation and droplet transport. The present investigation focuses on the unsteady effects due to rotor-stator interaction on the droplet formation process. Results of unsteady three dimensional flow simulations of a two-stage steam turbine are presented, whereby this is the first time that non-equilibrium condensation is considered in such simulations. The numerical approach is based on RANS equations, which are extended by a wet steam specific nucleation and droplet growth model. Despite the use of a high performance cluster the unsteady simulation has a considerably high simulation time of approximately 60 days by use of 48 CPUs. © Springer-Verlag Berlin Heidelberg 2012.
Resumo:
This paper describes a novel method that applies pressure-assisted field-amplified sample injection with reverse migrating micelles (PA-FASI-RMM) for the online concentration of neutral analytes in MEKC with a low-pH BGE. After injection of a plug of water into the separation capillary, negative voltage and positive pressure were simultaneously applied to initialize PA-FASI-RMM injection. The hydrodynamic flow generated by the positive pressure compensated the reverse EOF in the water plug and allowed the water plug to remain in the capillary during FASI with reverse migrating micelles (FASI-RMM) to obtain a much longer injection time than usual, which improved stacking efficiency greatly. Equations describing this injection mode were introduced and were supported by experimental results. For a 450-s online PA-FASI-RMM injection, three orders of magnitude sample enhancement in terms of peak area could be observed for the steroids and an achievement of detection limits was between 1 and 10 ng/mL.
Resumo:
Under a high-pressure mercury lamp (HPML) and using an exposure time of 4 h, the photoproduction of hydroxyl radicals ((OH)-O-.) could be induced in an aqueous solution containing humic acid (HA). Hydroxyl radicals were determined by high-performance liquid chromatography using benzene as a probe. The results showed that (OH)-O-. photoproduction increased from 1.80 to 2.74 muM by increasing the HA concentration from 10 to 40 mg L-1 at an exposure time of 4 h (pH 6.5). Hydroxyl radical photoproduction in aqueous solutions of HA containing algae was greater than that in the aqueous solutions of HA without algae. The photoproduction of (OH)-O-. in the HA solution with Fe(111) was greater than that of the solution without Fe(III) at pH ranging from 4.0 to 8.0. The photoproduction of (OH)-O-. in HA solution with algae with or without Fe(111) under a 250 W HPML was greater than that under a 125 W HPML. The photoproduction of (OH)-O-. in irradiated samples was influenced by the pH. The results showed that HPML exposure for 4 h in the 4-8 pH range led to the highest (OH)-O-. photoproduction at pH 4.0.
Resumo:
We study the two samples of AIInGaN, i.e., 1-mum GaN grown at 1030degreesC on the buffer and followed by a 0.6-mum-thick epilayer of AIInGaN under the low pressure of 76 Torr and the AIInGaN layer deposited directly on the buffer layer without the high-temperature GaN layer, by temperature-dependent photoluminescence (PL) spectroscopy and picosecond time-resolved photoluminescence (TRPL) spectroscopy. The TRPL signals of both the samples were fitted well as a stretched exponential decay at all temperatures, indicating significant disorder in the material. We attribute the disorder to nanoscale quantum dots or discs of high indium concentration. Temperature dependence of dispersive exponent beta shows that the stretched exponential decay of the two samples comes from different mechanisms. The different depths of the localization potential account for the difference, which is illustrated by the results of temperature dependence of radiative recombination lifetime and PL peak energy.
Resumo:
We studied, for the first time, the strong coupling between exciton and cavity mode within semiconductor microcavity under hydrostatic pressure, and measured the Rabi splitting. The strong coupling between exciton and cavity mode, and so Rabi splitting appear clearly as the applied pressure reaches 0.37-0.41 GPa. The experiment result shows that hydrostatic pressure not only can tune the coupling between exciton and cavity mode effectively, but also can keep exciton property almost unchanged during the whole tuning procedure in contrast to other tuning method (temperature field et al). Our result agrees with the related theory very well. The Rabi splitting, extracted from fitting the measured mode-energy vs pressure curves with correspanding theoretical model, is equal to 6 meV.
Resumo:
Pressure sensitivity of the fiber optic mandrel hydrophone is analyzed in this paper. Based on the theory of elasticity, the mechanism of the pressure response is studied. The influence of the optical fiber on the compliant mandrel on the pressure response is taken into consideration for the first time. The radial deformation of the mandrel under the pressure of the fiber optic and the underwater pressure is analyzed in details. Based on the theory of photo-elasticity, the phase shift of the Mach-Zehnder interferometer is given. The pressure sensitivity is evaluated both theoretically and experimentally, and the results show a good correlation between the theoretical and experimental results.
Resumo:
The applicability of on-line coupling of reversed-phase high-performance liquid chromatography to atmospheric pressure ionization tandem mass spectrometry for the separation and characterization of hop acids mixture from the crude extract of Humulus lupulus was investigated. The solvent system consisting of acetonitrile-aqueous formic acid was used to give proper separation of the six main hop bitter acids within 30 min. Further structural information about the components was acquired by collision-induced dissociation (CID). On the basis of analyses of the fragmentation patterns of the major alpha- and beta-bitter acids respectively, identification of the minor ones was performed using selected reaction monitoring (SRM) with a group of qualitatively relevant selected precursor-product ion transitions for each bitter acid in a single high performance liquid chromatography (HPLC) run. Using this technique, six minor hop acids, including "adprelupulone" observed for the first time in natural resources, were detected along with the six major acids. This hyphenated techniques provides potency for rapid qualitative determination of analogs and homologs in mixtures. (C) 2004 American Society for Mass Spectrometry.
Resumo:
Pure (W0.4Al0.6)C powder of about 1 mu m in diameter was sintered by the high pressure sintering (HPS) process without the addition of any binder phase. The microstructure, Vickers micro hardness and density versus the sintering time and temperature are well described. The most suitable sintering condition under pressure of 4.5 GPa is 1873 K for 8 min. Under this sintering condition, the hardness can reach 2295 kg mm(-2) and the relative density can reach 98.6%.
Resumo:
Ultrahigh pressure technique was employed to extract ginsenosides from roots of ginseng (Panax ginseng C.A. Meyer). The optimal conditions for ultrahigh pressure extraction (UPE) of total ginsenosides were quantified by UV-vis spectrophotometry with the ginsenoside Re as standard, the signal ginsenosides were quantified by HPLC and ELSD with ginsenosides Re, Rg(1), Rb-1, Rc and Rb-2 as standards. Orthogonal design was applied to evaluate the effects of four independent factors (extraction pressure, extraction temperature, extraction time and ethanol concentration) on the yield and 1,1-diphenyl-2-picrylhydrazyl (DPPH) radical scavenging activity of ginsenoside, which are based on microwave extraction (ME), ultrasound extraction (UE), soxhlet extraction (SE) and heat reflux extraction (HRE) method. The results showed that UPE method can produce ginsenoside with the highest yield and the best radical scavenging activity compared to other used ones. Scanning electron microscopic (SEM) images of the plant cells after ultrahigh pressure treatment was obtained to provide visual evidence of the disruption effect.
Resumo:
A novel hard material of (W0.5Al0.5)C-0.5 has been successfully sintered under high-pressure (4.5 GPa). The influence of sintering time and temperature on the microstructure, Vickers microhardness and density of the as-prepared specimens are well described. Interestingly, sintering temperature has an amazing influence on the hardness, density and microstructure of the specimen while the sintering time does not. It is found that the most suitable sintering condition from our work is 1600 degrees C and 10 min under pressure of 4.5 GPa. The hardness and relative density of the as-prepared sample can reach 2340 kg mm(-2) and 98.62%, respectively. The cell parameters of the sintered specimen is found to be little smaller than that of the powder, which we propose is related to the high pressure.
Resumo:
High-pressure synthesis of garnet Gd3In2Ga3O12 is reported. It was found that the pressure-temperature region for the synthesis of Gd3In2Ga3O12 can be expressed as T(degrees C) < 2350-250P(GPa), and high pressure greatly reduced the reaction time. It was also found that the garnet Gd3In2Ga3O12 decomposed to GdGaO3 and In2O3 under 3.5 GPa and 1650 degrees C, and this process was accompanied by an increasing density of the products and an increasing coordination number for Ga3+ (4 to 6).
Resumo:
A simple, sensitive, and mild method for the determination of amino compounds based on a condensation reaction with 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide hydrochloride (EDC-HCI) as the dehydrant with fluorescence detection has been developed. Amines were derivatized to their acidamides with labeling reagent 2-(2-phenyl-1H-phenanthro-[9,10-d]imidazole-1-yl)-acetic acid (PPIA). Studies on derivatization conditions indicated that the coupling reaction proceeded rapidly and smoothly in the presence of a base catalyst in acetonitrile to give the corresponding sensitively fluorescent derivatives with an excitation maximum at lambda(ex) 260nm and an emission maximum at lambda(em) 380nm. The labeled derivatives exhibited high stability and were enough to be efficiently analyzed by high-performance liquid chromatography. Identification of derivatives was carried out by online post-column mass spectrometry (LC/APCI-MS/MS) and showed an intense protonated molecular ion corresponding m/z [MH](+) under APCI in positive-ion mode. At the same time, the fluorescence properties of derivatives in various solvents or at different temperature were investigated. The method, in conjunction with a gradient elution, offered a baseline resolution of the common amine derivatives on a reversed-phase Eclipse XDB-C-8 column. LC separation for the derivatized amines showed good reproducibility with acetonitrile-water as mobile phase. Detection limits calculated from 0.78 pmol injection, at a signal-to-noise ratio of 3, were 3.1-18.2 fmol. The mean intra- and inter-assay precision for all amine levels were < 3.85% and 2.11%, respectively. Excellent linear responses were observed with coefficients of > 0.9996. The established method for the determination of aliphatic amines from real wastewater and biological samples was satisfactory. (c) 2006 Elsevier B.V. All rights reserved.