932 resultados para stability study


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This research aims to compare the public and private sectors with regard to satisfaction at work. We conducted a survey with 670 professionals from both sectors in Brazil. The results of variance analysis confirm previous researches indicating that public officials are less satisfied with their work than private sector workers. However, this result does not repeat when we evaluate the satisfaction dimensions. For instance, public officials reported being more satisfied than private sector workers with regard to social environment and work stability. Unexpectedly, the results suggest that there is no difference between these sectors when we analyze the satisfaction with supervision. Therefore, this article is relevant for Brazilian managers, by offering an empirical research on the distinction between public and private. The article also discusses the theoretical implications, since Brazilian findings do not completely support the international literature.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Captopril, an inhibitor of angiotensin converting enzyme (ACE), is used to treat medical conditions like hypertension and heart failure, and it is usually administered in tablet form for adults. Since this dosage form is not recommended for infants and children up to 6 years, hospital pharmacies have to prepare liquid formulations for oral administration of captopril. Traditionally, concentration of captopril used in the formulations is 1mg/ml. The problem is that captopril is prone to oxidation, and its stability in solution is affected by pH, concentration of captopril, the presence of oxygen or metal ions. The influence of different formulation ingredients on the properties of physical and chemical stability of captopril in liquid preparations has been evaluated. Main of the study: to evaluate the stability of captopril for 30 days when formulated in a 1 mg/ml suspension adjuvanted with citric acid.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To carry out a survey data collection from health care workers in Brazil, Croatia, Poland, Ukraine and the USA with two primary goals: (1) to provide information about which aspects of well-being are most likely to need attention when shiftwork management solutions are being developed, and (2) to explore whether nations are likely to differ with respect to the impacts of night work on the well-being of workers involved in health care work. METHODS: The respondents from each nation were sorted into night worker and non-night worker groups. Worker perceptions of being physically tired, mentally tired, and tense at the end of the workday were examined. Subjective reports of perceived felt age were also studied. For each of these four dependent variables, an ANCOVA analysis was carried out. Hours worked per week, stability of weekly work schedule, and chronological age were the covariates for these analyses. RESULTS: The results clearly support the general proposal that nations differ significantly in worker perceptions of well-being. In addition, perceptions of physical and mental tiredness at the end of the workday were higher for night workers. For the perception of being physically tired at the end of a workday, the manner and degree to which the night shift impacts the workers varies by nation. CONCLUSIONS: Additional research is needed to determine if the nation and work schedule differences observed are related to differences in job tasks, work schedule structure, off-the-job variables, and/or other worker demographic variables.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In memory of our beloved Professor José Rodrigues Santos de Sousa Ramos (1948-2007), who João Cabral, one of the authors of this paper, had the honor of being his student between 2000 and 2006, we wrote this paper following the research by experimentation, using the new technologies to capture a new insight about a problem, as him so much love to do it. His passion was to create new relations between different fields of mathematics. He was a builder of bridges of knowledge, encouraging the birth of new ways to understand this science. One of the areas that Sousa Ramos researched was the iteration of maps and the description of its behavior, using the symbolic dynamics. So, in this issue of this journal, honoring his memory, we use experimental results to find some stable regions of a specific family of real rational maps, the ones that he worked with João Cabral. In this paper we describe a parameter space (a,b) to the real rational maps fa,b(x) = (x2 −a)/(x2 −b), using some tools of dynamical systems, as the study of the critical point orbit and Lyapunov exponents. We give some results regarding the stability of these family of maps when we iterate it, specially the ones connected to the order 3 of iteration. We hope that our results would help to understand better the behavior of these maps, preparing the ground to a more efficient use of the Kneading Theory on these family of maps, using symbolic dynamics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The initial goal of this work was the development of a supported liquid membrane (SLM) bioreactor for the remediation of vaccine production effluents contaminated with a highly toxic organomercurial – thiomersal. Therefore, two main aspects were focused on: 1) the development of a stable supported liquid membrane – using room temperature ionic liquids (RTILs) – for the selective transport of thiomersal from the wastewater to a biological compartment, 2) study of the biodegradation kinetics of thiomersal to metallic mercury by a Pseudomonas putida strain. The first part of the work focused on the evaluation of the physicochemical properties of ionic liquids and on the SLMs’ operational stability. The results obtained showed that, although it is possible to obtain a SLM with a high stability, water possesses nonnegligible solubility in the RTILs studied. The formation of water clusters inside the hydrophobic ionic liquid was identified and found to regulate the transport of water and small ions. In practical terms, this meant that, although it was possible to transport thiomersal from the vaccine effluent to the biological compartment, complete isolation of the microbial culture could not be guaranteed and the membrane might ultimately be permeable to other species present in the aqueous vaccine wastewater. It was therefore decided not to operate the initially targeted integrated system but, instead, the biological system by itself. Additionally, attention was given to the development of a thorough understanding of the transport mechanisms involved in the solubilisation and transport of water through supported liquid membranes with RTILs as well as to the evaluation of the effect of water uptake by the SLM in the transport mechanisms of water-soluble solutes and its effect on SLM performance. The results obtained highlighted the determinant role played by water – solubilised inside the ionic liquids – on the transport mechanism. It became clear that the transport mechanism of water and water-soluble solutes through SLMs with [CnMIM][PF6] RTILs was regulated by the dynamics of water clusters inside the RTIL, rather than by molecular diffusion through the bulk of the ionic liquid. Although the stability tests vi performed showed that there were no significant losses of organic phase from the membrane pores, the formation of water clusters inside the ionic liquid, which constitute new, non-selective environments for solute transport, leads to a clear deterioration of SLM performance and selectivity. Nevertheless, electrical impedance spectroscopy characterisation of the SLMs showed that the formation of water clusters did not seem to have a detrimental effect on the SLMs’ electrical characteristics and highlighted the potential of using this type of membranes in electrochemical applications with low resistance requirements. The second part of the work studied the kinetics of thiomersal degradation by a pure culture of P. putida spi3 strain, in batch culture and using a synthe tic wastewater. A continuous ly stirred tank reactor fed with the synthetic wastewater was also operated and the bioreactor’s performance and robustness, when exposed to thiomersal shock loads, were evaluated. Finally, a bioreactor for the biological treatment of a real va ccine production effluent was set up and operated at different dilution rates. Thus it was possible to treat a real thiomersal-contaminated effluent, lowering the outlet mercury concentration to values below the European limit for mercury effluent discharges.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To study luminescence, reflectance, and color stability of dental composites and ceramics. Materials and Methods: IPS e.max, IPS Classic, Gradia, and Sinfony materials were tested, both unpolished (as-cast) and polished specimens. Coffee, tea, red wine, and distilled water (control) were used as staining drinks. Disk-shaped specimens were soaked in the staining drinks for up to 5 days. Color was measured by a colorimeter. Fluorescence was recorded using a spectrofluorometer, in the front-face geometry. Time-resolved fluorescence spectra were recorded using a laser nanosecond spectrofluorometer. Results: The exposure of the examined dental materials to staining drinks caused changes in color of the composites and ceramics, with the polished specimens exhibiting significantly lower color changes as compared to unpolished specimens. Composites exhibited lower color stability as compared to ceramic materials. Water also caused perceptible color changes in most materials. The materials tested demonstrated significantly different initial luminescence intensities. Upon exposure to staining drinks, luminescence became weaker by up to 40%, dependent on the drink and the material. Time-resolved luminescence spectra exhibited some red shift of the emission band at longer times, with the lifetimes in the range of tens of nanoseconds. Conclusions: Unpolished specimens with a more developed surface have lower color stability. Specimens stored in water develop some changes in their visual appearance. The presently proposed methods are effective in evaluating the luminescence of dental materials. Luminescence needs to be tested in addition to color, as the two characteristics are uncorrelated. It is important to further improve the color and luminescence stability of dental materials.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The susceptibility of the MAP Brazilian strain (F1 to F5 progenies) of S. mansoni to four antischistosomal drugs has been reported in a previous study. In the present investigation, progeny F14 of the same strain, was tested for stability to the same 4 drugs. A new medication, Oltipraz (35,972 RP), was added to the study. Five groups of 12 mice infected with cercariae by tail immersion were treated with hycanthone, oxamniquine, niridazole, praziquantel and Oltipraz. An untreated group was used as control. Schistosomal activity was assessed by the localization of worms in the portal vein system, by oogram changes, and percentage of parasite reduction. The stability of the susceptibility of progeny F14 did not change in relation to generations F1 to F5; the progeny was resistant to hycanthone and oxamniquine; but sensitive to niridazole, praziquantel and Oltipraz. We emphasize the importance of the phenomenon of resistance of the worm in view of the fact that oxamniquine has been widely used in Brazilian areas where mansonic schistosomiasis is endemic.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Motivated by the dark matter and the baryon asymmetry problems, we analyze a complex singlet extension of the Standard Model with a Z(2) symmetry (which provides a dark matter candidate). After a detailed two-loop calculation of the renormalization group equations for the new scalar sector, we study the radiative stability of the model up to a high energy scale (with the constraint that the 126 GeV Higgs boson found at the LHC is in the spectrum) and find it requires the existence of a new scalar state mixing with the Higgs with a mass larger than 140 GeV. This bound is not very sensitive to the cutoff scale as long as the latter is larger than 10(10) GeV. We then include all experimental and observational constraints/measurements from collider data, from dark matter direct detection experiments, and from the Planck satellite and in addition force stability at least up to the grand unified theory scale, to find that the lower bound is raised to about 170 GeV, while the dark matter particle must be heavier than about 50 GeV.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação apresentada para obtenção do Grau de Doutor em Conservação e Restauro, especialidade de Ciências da Conservação, pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Journal of Proteome Research (2006)5: 2720-2726

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Febs Journal (2009)276:1776-1786

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Doutor em Bioquímica – Ramo Bioquímica Estrutural

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: In the haemodynamically unstable patient the method of treatment of acute renal failure is still largely controversial. The purpose of our study was to compare slow extended dialysis with continuous haemodiafiltration in the critical patient with indication for renal replacement therapy and haemodynamic instability. Patients and Methods: This is a cohort study comparing in 63 ventilated critical patients a 12 month period when only continuous haemodiafiltration was used (n=25) with an equal period of slow extended dialysis (n=38). Our primary objective was to evaluate the impact of the dialytic procedure on cardiovascular stability in those patients. As secondary aims we considered system coagulation/thrombosis and predictors of mortality. In the two groups we analysed the first session performed, the second session performed and the average of all the sessions performed in each patient. Results: In these patients, mortality in the intensive care unit was high (68% in the continuous haemodiafiltration group and 63% in the slow extended dialysis group). We did not find any association between the dialytic technique used and death; only the APACHE score was a predictor of death. Slow extended dialysis was a predictor of haemodynamic stability, a negative predictor of sessions that had to be interrupted for haemodynamic instability, and a predictor of achieving the volume removal initially sought. Slow extended dialysis was also associated with less coagulation of the system. Conclusions: Our data suggested that slow extended dialysis use was not inferior to continuous haemodiafiltration use in terms of cardiovascular tolerability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertation presented to Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa for obtaining the master degree in Membrane Engineering

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis is a study of how heat is transported in non-steady-state conditions from a superconducting Rutherford cable to a bath of superfluid helium (He II). The same type of superconducting cable is used in the dipole magnets of the Large Hadron Collider (LHC). The dipole magnets of the LHC are immersed in a bath of He II at 1.9 K. At this temperature helium has an extremely high thermal conductivity. During operation, heat needs to be efficiently extracted from the dipole magnets to keep their superconducting state. The thermal stability of the magnets is crucial for the operation of the LHC, therefore it is necessary to understand how heat is transported from the superconducting cables to the He II bath. In He II the heat transfer can be described by the Landau regime or by the Gorter-Mellink regime, depending on the heat flux. In this thesis both measurements and numerical simulation have been performed to study the heat transfer in the two regimes. A temperature increase of 8 2 mK of the superconducting cables was successfully measured experimentally. A new numerical model that covers the two heat transfer regimes has been developed. The numerical model has been validated by comparison with existing experimental data. A comparison is made between the measurements and the numerical results obtained with the developed model.