973 resultados para safety communication


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. To evaluate the safety and immunogenicity of varicella vaccine (VV) in susceptible patients with juvenile rheumatic diseases receiving methotrexate and corticosteroids. Methods. Twenty-five patients with juvenile rheumatic diseases (ages 2-19 years) and 18 healthy children and adolescents (ages 3-18 years) received a single dose of VV. All 25 patients were receiving methotrexate; 13 were also receiving prednisone and 5 were also receiving other disease-modifying antirheumatic drugs. None of the vaccinated patients or controls had a previous history of varicella. Anti-varicella-zoster virus IgG antibody (anti-VZV-IgG) titers were measured by enzyme-linked immunosorbent assay immediately before, 4-6 weeks after, and 1 year after vaccination. The patients were monitored prospectively for adverse reactions related to the vaccine, exposure, and occurrence of varicella. Disease activity was assessed 3 months before and 3 months after VV. Results. Twenty patients and all of the controls had negative preimmunization titers of VZV-IgG, and 5 patients had equivocal levels. Positive VZV-IgG titers were detected in 10 (50%) of 20 seronegative patients and 13 (72.2%) of 18 controls 4-6 weeks after VV (P = 0.2). One year after vaccination, 8 of 10 patients maintained positive VZV-IgG titers. No overt varicella episodes and no severe adverse reactions were observed during the followup period. No worsening of clinical parameters and no flares of juvenile rheumatic diseases or changes in doses of medications used were detected after vaccination. In fact, the number of active joints in patients with juvenile idiopathic arthritis was significantly lower after VV (P = 0.009). Conclusion. VV appears to be safe in patients with juvenile rheumatic diseases receiving methotrexate, as long as continuous prospective vigilance for side effects is performed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Reports of iatrogenic thermal injuries during laparoscopic surgery using new generation vessel-sealing devices, as well as anecdotal reports of hand burn injuries during hand-assisted surgeries, have evoked questions about the temperature safety profile and the cooling properties of these instruments. Methods This study involved video recording of temperatures generated by different instruments (Harmonic ACE [ACE], Ligasure V [LV], and plasma trisector [PT]) applied according the manufacturers` pre-set settings (ACE setting 3; LV 3 bars, and the PT TR2 50W). The video camera used was the infrared Flex Cam Pro directed to three different types of swine tissue: (1) peritoneum (P), (2) mesenteric vessels (MV), and (3) liver (L). Activation and cooling temperature and time were measured for each instrument. Results The ACE device produced the highest temperatures (195.9 degrees +/- 14.5 degrees C) when applied against the peritoneum, and they were significantly higher than the other instruments (LV = 96.4 degrees +/- 4.1 degrees C, and PT = 87 degrees +/- 2.2 degrees C). The LV and PT consistently yielded temperatures that were < 100 degrees C independent of type of tissue or ""on""/ ""off"" mode. Conversely, the ACE reached temperatures higher than 200 degrees C, with a surprising surge after the instrument was deactivated. Moreover, temperatures were lower when the ACE was applied against thicker tissue (liver). The LV and PT cooling times were virtually equivalent, but the ACE required almost twice as long to cool. Conclusions The ACE increased the peak temperature after deactivation when applied against thick tissue (liver), and the other instruments inconsistently increased peak temperatures after they were turned off, requiring few seconds to cool down. Moreover, the ACE generated very high temperatures (234.5 degrees C) that could harm adjacent tissue or the surgeon`s hand on contact immediately after deactivation. With judicious use, burn injury from these instruments can be prevented during laparoscopic procedures. Because of the high temperatures generated by the ACE device, particular care should be taken when it is used during laparoscopy.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Subclinical mastitis is a common and easily disseminated disease in dairy herds. Its routine diagnosis via bacterial culture and biochemical identification is a difficult and time-consuming process. In this work, we show that matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) allows bacterial identification with high confidence and speed (1 d for bacterial growth and analysis). With the use of MALDI-TOF MS, 33 bacterial culture isolates from milk of different dairy cows from several farms were analyzed, and the results were compared with those obtained by classical biochemical methods. This proof-of-concept case demonstrates the reliability of MALDI-TOF MS bacterial identification, and its increased selectivity as illustrated by the additional identification of coagulase-negative Staphylococcus species and mixed bacterial cultures. Matrix-assisted laser desorption-ionization mass spectrometry considerably accelerates the diagnosis of mastitis pathogens, especially in cases of subclinical mastitis. More immediate and efficient animal management strategies for mastitis and milk quality control in the dairy industry can therefore be applied.