996 resultados para quality characteristic
Resumo:
Aims Trials of disease management programmes (DMP) in heart failure (HF) have shown controversial results regarding quality of life. We hypothesized that a DMP applied over the long-term could produce different effects on each of the quality-of-life components. Methods and results We extended the prospective, randomized REMADHE Trial, which studied a DMP in HF patients. We analysed changes in Minnesota Living with Heart Failure Questionnaire components in 412 patients, 60.5% male, age 50.2 +/- 11.4 years, left ventricular ejection fraction 34.7 +/- 10.5%. During a mean follow-up of 3.6 +/- 2.2 years, 6.3% of patients underwent heart transplantation and 31.8% died. Global quality-of-life scores improved in the DMP intervention group, compared with controls, respectively: 57.5 +/- 3.1 vs. 52.6 +/- 4.3 at baseline, 32.7 +/- 3.9 vs. 40.2 +/- 6.3 at 6 months, 31.9 +/- 4.3 vs. 41.5 +/- 7.4 at 12 months, 26.8 +/- 3.1 vs. 47.0 +/- 5.3 at the final assessment; P<0.01. Similarly, the physical component (23.7 +/- 1.4 vs. 21.1 +/- 2.2 at baseline, 16.2 +/- 2.9 vs. 18.0 +/- 3.3 at 6 months, 17.3 +/- 2.9 vs. 23.1 +/- 5.7 at 12 months, 11.4 +/- 1.6 vs. 19.9 +/- 2.4 final; P<0.01), the emotional component (13.2 +/- 1.0 vs. 12.1 +/- 1.4 at baseline, 11.7 +/- 2.7 vs. 12.3 +/- 3.1 at 6 months, 12.4 +/- 2.9 vs. 16.8 +/- 5.9 at 12 months, 6.7 +/- 1.0 vs. 10.6 +/- 1.4 final; P<0.01) and the additional questions (20.8 +/- 1.2 vs. 19.3 +/- 1.8 at baseline, 14.3 +/- 2.7 vs. 17.3 +/- 3.1 at 6 months, 12.4 +/- 2.9 vs. 21.0 +/- 5.5 at 12 months, 6.7 +/- 1.4 vs. 17.3 +/- 2.2 final; P<0.01) were better (lower) in the intervention group. The emotional component improved earlier than the others. Post-randomization quality of life was not associated with events. Conclusion Components of the quality-of-life assessment responded differently to DMP. These results indicate the need for individualized DMP strategies in patients with HF. Trial registration information www.clincaltrials.gov NCT00505050-REMADHE.
Resumo:
Background: A previous study associated CD34(+) levels with NYHA functional class in heart failure patients. The aim of this study was to correlate CD34(+) levels to exercise capacity, functional class, quality of life and norepinephrine in heart failure patients. Methods: Twenty three sedentary patients (52 +/- 7 years, 78% male) answered the Minnesota Living with Heart Failure Questionnaire and rested for 20 minutes before an investigator collect a blood sample. After this, patients performed a cardiopulmonary exercise test to determine the heart rate at anaerobic and ventilatory threshold and oxygen consumption at peak effort, at anaerobic and ventilatory threshold. One other blood sample was collected during the peak effort to investigate the norepinephrine and CD34(+) levels. Results: Rest percentage of CD34(+) did not show correlation with: left ventricle ejection fraction (r = 0.03, p = 0.888), peakVO(2) (r = 0.32, p = 0.13), VO(2) at anaerobic threshold (VO(2)AT) (r = 0.03, p = 0.86), VO(2) at ventilatory threshold (VO(2)VT) (r = 0.36, p = 0.08), NYHA functional class (r = -0.2, p = 0.35), quality of life (Minnesota) (r = -0.17, p = 0.42). CD34(+) did not show correlation, either, with: peak VO(2) (r = 0.38, p = 0.06), VO(2)AT (r = 0.09, p = 0.65), VO(2)VT (r = 0.43, p = 0.4), NYHA functional class (r = -0.13, p = 0.54), quality of life (r = 0.00, p = 0.99). Conclusions: CD34(+) levels did not correlate with exercise capacity, functional class, quality of life and norepinephrine. Percentage of CD34(+) levels did not increase during the cardiopulmonary exercise test in heart failure patients. (Cardiol J 2009; 16, 5: 426-431)
Resumo:
A full set of (higher-order) Casimir invariants for the Lie algebra gl(infinity) is constructed and shown to be well defined in the category O-FS generated by the highest weight (unitarizable) irreducible representations with only a finite number of nonzero weight components. Moreover, the eigenvalues of these Casimir invariants are determined explicitly in terms of the highest weight. Characteristic identities satisfied by certain (infinite) matrices with entries from gl(infinity) are also determined and generalize those previously obtained for gl(n) by Bracken and Green [A. J. Bracken and H. S. Green, J. Math. Phys. 12, 2099 (1971); H. S. Green, ibid. 12, 2106 (1971)]. (C) 1997 American Institute of Physics.
Evaluation of oral-motor movements and speech in patients with tetanus of a public service in Brazil
Resumo:
The characterisation of oral-motor movements and speech of patients with tetanus were investigated to determine the existence of possible signs that are characteristic of this pathology. Thirteen patients clinically diagnosed with tetanus (10 with severe tetanus and three with very severe tetanus) and admitted to an intensive care unit underwent clinical evaluation of oral-motor movements and speech. Statistical analysis indicated significant between-group differences for speech motor functions, suggesting that individuals with very severe tetanus present rigidity as a characteristic interfering in articulatory precision (P = 0 035) and movement rate (P = 0 038). For lip closure, tongue movement, palatal elevation, gag reflex and voice quality, no between-group differences were identified for the specific abnormal characteristics. The observed abnormal results indicate that muscle strength and functional status of the oral-motor system presented by most of the participants of the study did not ensure the necessary integrity for satisfactory performance. The characterisation of the oral myofunctional aspects of patients with tetanus provides medical teams, patients and families with a wider and better description of the clinical situation, giving support to the diagnosis, prognostics and treatment.
Resumo:
Morbid obesity is highly prevalent in the Western World, and its consequences present a real public health challenge. Voice alterations can represent one of these consequences and represent an opportunity for interference with therapeutic methods. This particularly features of the individual`s voice was the goal of the present study. A group of 45 adult volunteers of both sexes with a BMI greater than 35 Kg/m(2) was selected among patients of the Obesity Ambulatory of the Digestive Surgery Division. The control group consisted of volunteers matched by sex, age (+/- 1 year), and smoking habits, but with a BMI bellow 30 Kg/m(2). All subjects were submitted to laryngoscopic examination, audio perceptive analysis, and voice acoustics determination. Examinations were always performed by the same doctor, and diagnoses were provided by two different physician specialists in laryngology and voice. Obese individuals exhibit the following modifications in voice feature: hoarseness, murmuring, vocal instability, altered jitter and shimmer, and reduced maximum phonation times as well the presence of voice strangulation at the end of emission. The voices of individuals with morbid obesity are different of the voice of nonobese people and demonstrate significant changes in vocal characteristics.
Resumo:
Background:The Nasal Obstruction Symptom Evaluation (NOSE) instrument is a disease-specific questionnaire for assessing the outcome of an intervention in nasal obstruction in trials. This instrument is only available in the English language and cross-culturally valid questionnaires are very important for all research, including nasal obstruction. The aim of the current study was to reproduce the cross-cultural adaptation process for the NOSE questionnaire in the Portuguese language (NOSE-p). Methodology: Cross-cultural adaptation and validation of the instrument were divided into two stages. Stage I involved four bilingual professionals, an expert committee and the author of the original instrument. In Stage 2, the NOSE-p was tested on 33 patients undergoing septoplasty for internal consistency, test-retest reliability, construct validity. discriminant validity, criterion validity, and response sensitivity. Results: The cross-cultural adaptation process was completed and the NOSE-p was demonstrated to be a valid instrument with satisfactory construct validity. It showed an adequate internal consistency reliability and adequate test-retest reliability. It could discriminate between patients with and without nasal obstruction and it has a high response sensitivity to change. Conclusions: The cross-cultural adaptation and validation process demonstrated to be valid and the NOSE-p proved to be applicable in Brazil.
Resumo:
Objective. Refractory, disabling pain associated with knee osteoarthritis (OA) is usually treated with total knee replacement. However, pain in these patients might be associated with central nervous sensitization rather than peripheral inflammation and injury. We evaluated the presence of hyperalgesia in patients scheduled for a total knee replacement due to knee osteoarthritis with refractory pain, and we assessed the impact of pressure pain threshold measurements (PPT) on pain, disability, and quality of life of these patients. Methods. Sixty-two female patients were compared with 22 age-matched healthy controls without reported pain for the last year. PPT was measured at the lower extremities subcutaneous dermatomes, over the vastus medialis, adductor longus, rectus femoris, vastus lateralis, tibialis anterior, peroneus longus, iliacus, quadratus lumborum and popliteus muscles and at the supraspinous ligaments from L1-L5, over the L5-S1 and S1-S2 sacral areas and at the pes anserinus bursae and patellar tendon. Results. Patients with knee OA had significantly lower PPT over all evaluated structures versus healthy control subjects (P < 0.001). Lower PPT values were correlated with higher pain intensity, higher disability scores, and with poorer quality of life, except for the role-emotional and general health status. Combined PPT values over the patellar tendon, at the S2 subcutaneous dermatome and at the adductor longus muscle were the best predictors for visual analog scale and Western Ontario and McMaster Universities Osteoarthritis Index pain scores. Conclusion. Patients with pain due to osteoarthritis who were scheduled for total knee replacement showed hyperalgesia of nervous system origin that negatively impacted pain, knee functional capacity, and most aspects of quality of life.
Cross-cultural adaptation and validation of a Brazilian Portuguese version of the chronic pain grade
Resumo:
To verify the reliability and validity of a Brazilian Portuguese version of the chronic pain grade (CPG-Br). Cultural adaptation was made in accordance with established guidelines, with modifications aiming at improving this process. Adaptations were made based on interviews with 45 chronic pain patients from So Paulo city. Validation was studied by concurrent application of the short-form-36 health survey (SF-36) and other questionnaires to 283 participants with chronic pain from the general population. Temporal stability was verified by a second application to 131 individuals. Factor analysis resulted in a two-factor solution with factors named characteristic pain intensity and activity limitation due to pain. Alpha coefficients of 0.78 and 0.70 and intraclass correlation coefficients of 0.76 and 0.72 for each factor indicated good internal consistency and temporal stability. Significant correlations between CPG-Br and SF-36, Roland-Morris disability questionnaire and neck disability index scores were noted. A consistent linear trend was also observed between pain grades and SF-36 scores. Frequency of use of pain medications and of pain-related medical visits increased with pain grade. This Brazilian Portuguese version of the chronic pain grade, tested on a sample of the Brazilian population, demonstrated good reliability and validity.
Resumo:
Background: The cerebrospinal fluid (CSF) biomarkers amyloid beta (A beta)-42, total-tau (T-tau), and phosphorylated-tau (P-tau) demonstrate good diagnostic accuracy for Alzheimer`s disease (AD). However, there are large variations in biomarker measurements between studies, and between and within laboratories. The Alzheimer`s Association has initiated a global quality control program to estimate and monitor variability of measurements, quantify batch-to-batch assay variations, and identify sources of variability. In this article, we present the results from the first two rounds of the program. Methods: The program is open for laboratories using commercially available kits for A beta, T-tau, or P-tau. CSF samples (aliquots of pooled CSF) are sent for analysis several times a year from the Clinical Neurochemistry Laboratory at the Molndal campus of the University of Gothenburg, Sweden. Each round consists of three quality control samples. Results: Forty laboratories participated. Twenty-six used INNOTEST enzyme-linked immunosorbent assay kits, 14 used Luminex xMAP with the INNO-BIA AlzBio3 kit (both measure A beta-(1-42), P-tau(181P), and T-tau), and 5 used Mesa Scale Discovery with the A beta triplex (A beta N-42, A beta N-40, and A beta N-38) or T-tau kits. The total coefficients of variation between the laboratories were 13% to 36%. Five laboratories analyzed the samples six times on different occasions. Within-laboratory precisions differed considerably between biomarkers within individual laboratories. Conclusions: Measurements of CSF AD biomarkers show large between-laboratory variability, likely caused by factors related to analytical procedures and the analytical kits. Standardization of laboratory procedures and efforts by kit vendors to increase kit performance might lower variability, and will likely increase the usefulness of CSF AD biomarkers. (C) 2011 The Alzheimer`s Association. All rights reserved.
Resumo:
Toxoplasma gondii causes severe disease both to man and livestock and its detection in meat after slaughtering requires PCR or biological tests. Meat packages contain retained exudate that could be used for serology due to its blood content. Similar studies reported false negative assays in those tests. We standardized an anti-T. gondii IgG ELISA in muscle juices from experimentally infected rabbits, with blood content determination by cyanhemoglobin spectrophotometry. IgG titers and immunoblotting profiles were similar in blood, serum or meat juice, after blood content correction. These assays were adequate regardless of the storage time up to 120 days or freeze-thaw cycles, without false negative results. We also found 1.35% (1/74) positive sample in commercial Brazilian rabbit meat cuts, by this assay. The blood content determination shows ELISA of meat juice may be useful for quality control for toxoplasmosis monitoring. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
Dizziness is frequent in elderly people. Aims: To evaluate the Quality of Life (QoL) in elderly subjects with dizziness, relate it with gender and age. Material and Method: A prospective study comprising 120 elderly patients with dizziness evaluated with Brazilian versions of the Whoqol-bref and the dizziness handicap inventory (DHI). The factor analysis (FA), the Mann Whitney and Kruskal Wallis tests, and the Spearman correlation were applied to study the results. Results: The most compromised domains were the DHI physical domain and the Whoqol-bref physical and environment domains. FA resulted in 3 factors in the DHI and 5 factors in the Whoqol-bref. There was a moderate correlation (-0.596) in the total scores of both instruments. Males had a better QoL in the ""environment perception and introspectivity"" and ""health perception"" factors of the Whoqol-bref test. Females had a better QoL in the ""functionality perception"" factor of the Whoqol-bref test. There were no significant age differences. Conclusions: Elderly patients with dizziness have a worse QoL. Elderly females with dizziness have worse QoL scores in ""environment perception and introspectivity"" and ""health perception"" and better QoL in the ""functionality perception"" factor compared to elderly males.
Resumo:
The goal of the current study was to compare the quality of esophageal speech and voice to videofluoroscopic features of the esophagus and pharyngoesophageal (PE) segment. The speech and voice characteristics of 30 laryngectomized patients were rated by 5 speech-language pathologists. Based on these ratings, patients were divided into 3 categories: fluent (n = 9), moderately fluent (n = 10) and nonfluent (n = 11). Videofluoroscopy of the PE region was then performed during both swallowing and voice production. An insufflation test and percutaneous pharyngeal plexus block were required in 9 patients to determine the etiology of poor esophageal voice production. The strongest videofluoroscopic indicators of nonfluent speakers were: (1) small or absent air reservoir and (2) lack of a vibrating PE segment. Fluent speakers presented with shorter PE segments (1.17 mm) compared to moderately fluent speakers (17.1-29.9 mm). Perceptually, fluent speakers presented with a predominantly rough vocal quality. In contrast, moderately fluent speakers presented with a tense quality. In addition, stoma blast noise was reduced in fluent speakers. Videofluoroscopic findings highly correlated with the quality of esophageal speech. Copyright (C) 2009 S. Karger AG, Basel