942 resultados para power spectral density


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Autonomic control of heart rate variability and the central location of vagal preganglionic neurones (VPN) were examined in the rattlesnake ( Crotalus durissus terrificus), in order to determine whether respiratory sinus arrhythmia (RSA) occurred in a similar manner to that described for mammals. Resting ECG signals were recorded in undisturbed snakes using miniature datalogging devices, and the presence of oscillations in heart rate (f(H)) was assessed by power spectral analysis (PSA). This mathematical technique provides a graphical output that enables the estimation of cardiac autonomic control by measuring periodic changes in the heart beat interval. At fH above 19 min(-1) spectra were mainly characterised by low frequency components, reflecting mainly adrenergic tonus on the heart. By contrast, at f(H) below 19 min(-1) spectra typically contained high frequency components, demonstrated to be cholinergic in origin. Snakes with a f(H) > 19 min(-1) may therefore have insufficient cholinergic tonus and/or too high an adrenergic tonus acting upon the heart for respiratory sinus arrhythmia ( RSA) to develop. A parallel study monitored f(Hd) simultaneously with the intraperitoneal pressures associated with lung inflation. Snakes with a fH < 19 min(-1) exhibited a high frequency (HF) peak in the power spectrum, which correlated with ventilation rate (f(V)). Adrenergic blockade by propranolol infusion increased the variability of the ventilation cycle, and the oscillatory component of the f(H) spectrum broadened accordingly. Infusion of atropine to effect cholinergic blockade abolished this HF component, confirming a role for vagal control of the heart in matching f(H) and f(V) in the rattlesnake. A neuroanatomical study of the brainstem revealed two locations for vagal preganglionic neurones (VPN). This is consistent with the suggestion that generation of ventilatory components in the heart rate variability (HRV) signal are dependent on spatially distinct loci for cardiac VPN. Therefore, this study has demonstrated the presence of RSA in the HRV signal and a dual location for VPN in the rattlesnake. We suggest there to be a causal relationship between these two observations.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A linearly-tunable ULV transconductor featuring excellent stability of the processed signal common-mode voltage upon tuning, critical for very-low voltage applications, is presented. Its employment to the synthesis of CMOS gm-C high-frequency and voiceband filters is discussed. SPICE data describe the filter characteristics. For a 1.3 V-supply, their nominal passband frequencies are 1.0 MHz and 3.78 KHz, respectively, with tuning rates of 12.52 KHz/mV and 0.16 KHz/m V, input-referred noise spectral density of 1.3 μV/Hz1/2 and 5.0μV/Hz1/2 and standby consumption of 0.87 mW and 11.8 μW. Large-signal distortion given by THD = 1% corresponds to a differential output-swing of 360 mVpp and 480 mVpp, respectively. Common-mode voltage deviation is less than 4 mV over tuning interval.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper considers the importance of using a top-down methodology and suitable CAD tools in the development of electronic circuits. The paper presents an evaluation of the methodology used in a computational tool created to support the synthesis of digital to analog converter models by translating between different tools used in a wide variety of applications. This tool is named MS 2SV and works directly with the following two commercial tools: MATLAB/Simulink and SystemVision. Model translation of an electronic circuit is achieved by translating a mixed-signal block diagram developed in Simulink into a lower level of abstraction in VHDL-AMS and the simulation project support structure in SystemVision. The method validation was performed by analyzing the power spectral of the signal obtained by the discrete Fourier transform of a digital to analog converter simulation model. © 2011 IEEE.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Whole-body vibration exposure of locomotive engineers and the vibration attenuation of seats in 22 U.S. locomotives (built between 1959 and 2000) was studied during normal revenue service and following international measurement guidelines. Triaxial vibration measurements (duration mean 155 min, range 84-383 min) on the seat and on the floor were compared. In addition to the basic vibration evaluation (aw rms), the vector sum (av), the maximum transient vibration value (MTVV/aw), the vibration dose value (VDV/(aw T1/4)), and the vibration seat effective transmissibility factor (SEAT) were calculated. The power spectral densities are also reported. The mean basic vibration level (aw rms) was for the fore-aft axis x = 0.18 m/sec2, the lateral axis y = 0.28 m/sec2, and the vertical axis z = 0.32 m/sec2. The mean vector sum was 0.59 m/sec2 (range 0.27 to 1.44). The crest factors were generally at or above 9 in the horizontal and vertical axis. The mean MTVV/aw was 5.3 (x), 5.1 (y), and 4.8 (z), and the VDV/(aw T1/4) values ranged from 1.32 to 2.3 (x-axis), 1.33 to 1.7 (y-axis), and 1.38 to 1.86 (z-axis), generally indicating high levels of shocks. The mean seat transmissibility factor (SEAT) was 1.4 (x) and 1.2 (y) and 1 (z), demonstrating a general ineffectiveness of any of the seat suspension systems. In conclusion, these data indicate that locomotive rides are characterized by relatively high shock content (acceleration peaks) of the vibration signal in all directions. Locomotive vertical and lateral vibrations are similar, which appears to be characteristic for rail vehicles compared with many road/off-road vehicles. Tested locomotive cab seats currently in use (new or old) appear inadequate to reduce potentially harmful vibration and shocks transmitted to the seated operator, and older seats particularly lack basic ergonomic features regarding adjustability and postural support.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Palaeoclimatic information can be retrieved from the diffusion of the stable water isotope signal during firnification of snow. The diffusion length, a measure for the amount of diffusion a layer has experienced, depends on the firn temperature and the accumulation rate. We show that the estimation of the diffusion length using power spectral densities (PSDs) of the record of a single isotope species can be biased by uncertainties in spectral properties of the isotope signal prior to diffusion. By using a second water isotope and calculating the difference in diffusion lengths between the two isotopes, this problem is circumvented. We study the PSD method applied to two isotopes in detail and additionally present a new forward diffusion method for retrieving the differential diffusion length based on the Pearson correlation between the two isotope signals. The two methods are discussed and extensively tested on synthetic data which are generated in a Monte Carlo manner. We show that calibration of the PSD method with this synthetic data is necessary to be able to objectively determine the differential diffusion length. The correlation-based method proves to be a good alternative for the PSD method as it yields precision equal to or somewhat higher than the PSD method. The use of synthetic data also allows us to estimate the accuracy and precision of the two methods and to choose the best sampling strategy to obtain past temperatures with the required precision. In addition to application to synthetic data the two methods are tested on stable-isotope records from the EPICA (European Project for Ice Coring in Antarctica) ice core drilled in Dronning Maud Land, Antarctica, showing that reliable firn temperatures can be reconstructed with a typical uncertainty of 1.5 and 2 °C for the Holocene period and 2 and 2.5 °C for the last glacial period for the correlation and PSD method, respectively.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Ten ODP sites drilled in a depth transect (2164-4775 m water depth) during Leg 172 recovered high-deposition rate (>20 cm/kyr) sedimentary sections from sediment drifts in the western North Atlantic. For each site an age model covering the past 0.8-0.9 Ma has been developed. The time scales have a resolution of 10-20 kyr and are derived by tuning variations of estimated carbonate content to the orbital parameters precession and obliquity. Based on the similarity in the signature of proxy records and the spectral character of the time series, the sites are divided into two groups: precession cycles are better developed in carbonate records from a group of shallow sites (2164-2975 m water depth, Sites 1055-1058) while the deeper sites (2995-4775 m water depth, Sites 1060-1063) are characterized by higher spectral density in the obliquity band. The resulting time scales show excellent coherence with other dated carbonate and isotope records from low latitudes. Besides the typical Milankovitch cyclicity significant variance of the resulting carbonate time series is concentrated at millennial-scale changes with periods of about 12, 6, 4, 2.5, and 1.5 kyr. Comparisons of carbonate records from the Blake Bahama Outer Ridge and the Bermuda Rise reveal a remarkable similarity in the time and frequency domain indicating a basin-wide uniform sedimentation pattern during the last 0.9 Ma.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BioMet®Tools is a set of software applications developed for the biometrical characterization of voice in different fields as voice quality evaluation in laryngology, speech therapy and rehabilitation, education of the singing voice, forensic voice analysis in court, emotional detection in voice, secure access to facilities and services, etc. Initially it was conceived as plain research code to estimate the glottal source from voice and obtain the biomechanical parameters of the vocal folds from the spectral density of the estimate. This code grew to what is now the Glottex®Engine package (G®E). Further demands from users in medical and forensic fields instantiated the development of different Graphic User Interfaces (GUI’s) to encapsulate user interaction with the G®E. This required the personalized design of different GUI’s handling the same G®E. In this way development costs and time could be saved. The development model is described in detail leading to commercial production and distribution. Study cases from its application to the field of laryngology and speech therapy are given and discussed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Hollow heart is a problem quite specific to seedless watermelon, affecting to all varieties. Percentage of fruits affected range from nil to up to more than 50% of the fruits. The acoustic impulse response of 158 watermelons was measured using a prepolarized free-field microphone. After carrying out a fast Fourier transformation on the time signal of the generated sound several acoustic parameters were evaluated. Values of spectral density were significantly different between 'good watermelons' and 'hollow heart watermelons'.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BioMet®Phon is a software application developed for the characterization of voice in voice quality evaluation. Initially it was conceived as plain research code to estimate the glottal source from voice and obtain the biomechanical parameters of the vocal folds from the spectral density of the estimate. This code grew to what is now the Glottex®Engine package (G®E). Further demands from users in laryngology and speech therapy fields instantiated the development of a specific Graphic User Interface (GUI’s) to encapsulate user interaction with the G®E. This gave place to BioMet®Phon, an application which extracts the glottal source from voice and offers a complete parameterization of this signal, including distortion, cepstral, spectral, biomechanical, time domain, contact and tremor parameters. The semantic capabilities of biomechanical parameters are discussed. Study cases from its application to the field of laryngology and speech therapy are given and discussed. Validation results in voice pathology detection are also presented. Applications to laryngology, speech therapy, and monitoring neurological deterioration in the elder are proposed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper aims to set out the influence of the flow field around high speed trains in open field. To achieve this parametric analysis of the sound pressure inside the train was performed. Three vibroacoustic models of a characteristic train section are used to predict the noise inside the train in open field by using finite element method FEM, boundary element method (BEM) and statistical energy analysis (SEA) depending on the frequency range of analysis. The turbulent boundary layer excitation is implemented as the only airborne noise source, in order to focus on the study of the attached and detached flow in the surface of the train. The power spectral densities of the pressure fluctuation in the train surface proposed by [Cockburn and Roberson 1974, Rennison et al. 2009] are applied on the exterior surface of the structural subsystems in the vibroacoustic models. An increase in the sound pressure level up to10 dB can be appreciated due to the detachment of the flow around the train. These results highlight the importance to determine the detached regions prediction, making critical the airborne noise due to turbulent boundary layer.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The application of a recently developed model of sonic anemometers measuring process has revealed that these sensors cannot be considered as absolute ones when measuring spectral characteristics of turbulent wind speed since it is demonstrated that the ratios of measured to real spectral density functions depend on the composition and temperature of the considered planetary atmosphere. The new model of the measuring process of sonic anemometers is applied to describe the measuring characteristics of these sensors as fluid/flow dependent (against the traditional hypothesis of fluid/flow independence) and hence dependent on the considered planetary atmosphere. The influence of fluid and flow characteristics (quantified via the Mach number of the flow) and the influence of the design parameters of sonic anemometers (mainly represented by time delay between pulses shots and geometry) on turbulence measurement are quantified for the atmospheres of Mars, Jupiter, and Earth. Important differences between the behavior of these sensors for the same averaged wind speed in the three considered atmospheres are detected in terms of characteristics of turbulence measurement as well as in terms of optimum values of anemometer design parameters for application on the different considered planetary atmospheres. These differences cannot be detected by traditional models of sonic anemometer measuring process based on line averaging along the sonic acoustic paths.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A proposta do presente estudo foi avaliar os efeitos do laser de baixa intensidade na regeneração óssea no procedimento de expansão rápida da maxila. Utilizou-se 27 indivíduos com média de idade de 10,2 anos, divididos em dois grupos: grupo laser (n=14), no qual se realizou a expansão rápida da maxila, associada ao laser e grupo sem laser (n=13), que realizou somente a expansão rápida da maxila. O protocolo de ativação do parafuso expansor foi de 1 volta completa no primeiro dia e ½ volta diária até a sobrecorreção. O laser utilizado foi o de diodo (TWIN Laser MMOptics®, São Carlos), seguindo o protocolo de aplicação: comprimento de onda de 780nm, potência de 40mW, densidade de 10J/cm2, em 10 pontos localizados ao redor da sutura palatina mediana. Os estágios de aplicação foram: L1 (do primeiro ao quinto dia de aplicação), L2 (travamento do parafuso e 3 dias seguidos), L3, L4 e L5 (após 7, 14 e 21 dias do L2, respectivamente). Radiografias oclusais da maxila foram realizadas com auxílio de uma escala de alumínio, para referencial densitométrico, em diferentes tempos: T1 (inicial), T2 (dia de travamento do parafuso), T3 (3 a 5 dias do T2), T4 (30 dias do T3), T5 (60 dias do T4). As radiografias foram digitalizadas e submetidas a um programa de imagem (Image Tool - UTHSCSA, Texas, USA), para mensuração da densidade óptica das áreas previamente selecionadas. Para realização do teste estatístico, utilizou-se a Análise de Covariância usando como covariável o tempo para a fase avaliada. Em todos os testes foi adotado nível de significância de 5% (p<0,05).Para o Grupo Laser, os dados mostram que houve uma queda significante de densidade durante a abertura do parafuso (T2-T1), um aumento significante da mesma no período final de avaliação (T5-T4), e um aumento também da densidade no período de regeneração propriamente dito (T5-T2), ou seja, a partir do momento em que finalizou a fase de abertura do parafuso expansor. Enquanto que no Grupo Sem Laser, a densidade não mostrou diferença estatisticamente significantemente em nenhum período analisado. Os resultados mostraram que o laser propiciou consideravelmente uma melhor abertura da sutura palatina mediana, além de influenciar no processo de regeneração óssea da sutura, acelerando seus processos de reparo.(AU)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A proposta do presente estudo foi avaliar os efeitos do laser de baixa intensidade na regeneração óssea no procedimento de expansão rápida da maxila. Utilizou-se 27 indivíduos com média de idade de 10,2 anos, divididos em dois grupos: grupo laser (n=14), no qual se realizou a expansão rápida da maxila, associada ao laser e grupo sem laser (n=13), que realizou somente a expansão rápida da maxila. O protocolo de ativação do parafuso expansor foi de 1 volta completa no primeiro dia e ½ volta diária até a sobrecorreção. O laser utilizado foi o de diodo (TWIN Laser MMOptics®, São Carlos), seguindo o protocolo de aplicação: comprimento de onda de 780nm, potência de 40mW, densidade de 10J/cm2, em 10 pontos localizados ao redor da sutura palatina mediana. Os estágios de aplicação foram: L1 (do primeiro ao quinto dia de aplicação), L2 (travamento do parafuso e 3 dias seguidos), L3, L4 e L5 (após 7, 14 e 21 dias do L2, respectivamente). Radiografias oclusais da maxila foram realizadas com auxílio de uma escala de alumínio, para referencial densitométrico, em diferentes tempos: T1 (inicial), T2 (dia de travamento do parafuso), T3 (3 a 5 dias do T2), T4 (30 dias do T3), T5 (60 dias do T4). As radiografias foram digitalizadas e submetidas a um programa de imagem (Image Tool - UTHSCSA, Texas, USA), para mensuração da densidade óptica das áreas previamente selecionadas. Para realização do teste estatístico, utilizou-se a Análise de Covariância usando como covariável o tempo para a fase avaliada. Em todos os testes foi adotado nível de significância de 5% (p<0,05).Para o Grupo Laser, os dados mostram que houve uma queda significante de densidade durante a abertura do parafuso (T2-T1), um aumento significante da mesma no período final de avaliação (T5-T4), e um aumento também da densidade no período de regeneração propriamente dito (T5-T2), ou seja, a partir do momento em que finalizou a fase de abertura do parafuso expansor. Enquanto que no Grupo Sem Laser, a densidade não mostrou diferença estatisticamente significantemente em nenhum período analisado. Os resultados mostraram que o laser propiciou consideravelmente uma melhor abertura da sutura palatina mediana, além de influenciar no processo de regeneração óssea da sutura, acelerando seus processos de reparo.(AU)