986 resultados para polarized light


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: This study aimed to evaluate the survival probability of four narrow-diameter implant systems when subjected to fatigue loading. Materials and Methods: Seventy-two narrow-diameter implants to be restored with single-unit crowns were divided into four groups (n = 18): Astra Tech (3.5-mm diameter), with a standard connection (ASC); BioHorizon (3.4-mm diameter), with a standard connection (BSC); Intra-Lock (3.4-mm diameter), with a standard multilobular connection (ISC); and Intra-Lock (3.4-diameter), with a modified square connection (IMC). The corresponding abutments were screwed onto the implants, and standardized metal crowns (maxillary central incisors) were cemented and subjected to step-stress accelerated life testing in water. Use-level probability Weibull curves and reliability for 100,000 cycles at 150 and 200 N (90% two-sided confidence intervals) were calculated. Polarized light and scanning electron microscopes were used to access the failure modes. Results: The calculated survival probability for 100,000 cycles at 150 N was approximately 93% in group ASC, 98% in group BSC, 94% in group ISC, and 99% in group IMC. At 200 N, the survival rate was estimated to be approximately < 0.1% for ASC, 77% for BSC, 34% for ISC, and 93% for IMC. Abutment screw fracture was the main failure mode for all groups. Conclusions: Although the probability of survival was not significantly different among systems at a load of 150 N, a significant decrease was observed at 200 N for all groups except IMC.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To evaluate and compare the reliability of implant-supported single crowns cemented onto abutments retained with coated (C) or noncoated (NC) screws and onto platform-switched abutments with coated screws. Materials and Methods: Fifty-four implants (DT Implant 4-mm Standard Platform, Intra-Lock International) were divided into three groups (n = 18 each) as follows: matching-platform abutments secured with noncoated abutment screws (MNC); matching-platform abutments tightened with coated abutment screws (MC); and switched-platform abutments secured with coated abutment screws (SC). Screws were characterized by scanning electron microscopy and x-ray photoelectron spectroscopy (XPS). The specimens were subjected to step-stress accelerated life testing. Use-level probability Weibull curves and reliability for 100,000 cycles at 200 N and 300 N (90% two-sided confidence intervals) were calculated. Polarized light and scanning electron microscopes were used for fractographic analysis. Results: Scanning electron microscopy revealed differences in surface texture; noncoated screws presented the typical machining grooves texture, whereas coated screws presented a plastically deformed surface layer. XPS revealed the same base components for both screws, with the exception of higher degrees of silicon in the SiO2 form for the coated samples. For 100,000 cycles at 300 N, reliability values were 0.06 (0.01 to 0.16), 0.25 (0.09 to 0.45), and 0.25 (0.08 to 0.45), for MNC, MC, and SC, respectively. The most common failure mechanism for MNC was fracture of the abutment screw, followed by bending, or its fracture, along with fracture of the abutment or implant. Coated abutment screws most commonly fractured along with the abutment, irrespective of abutment type. Conclusion: Reliability was higher for both groups with the coated screw than with the uncoated screw. Failure modes differed between coated and uncoated groups.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives: The aim of this study was to evaluate the anticaries effect of low-fluoride toothpastes combined with hexametaphosphate (HMP) on enamel demineralization.Methods: Bovine enamel blocks were subjected to pH cycling and treatment with toothpaste's slurries (15 groups; 2x/day). Toothpaste mixtures contained the following: no fluoride (F) plus HMP (from 0 to 3.0%); 250 ppm F plus HMP (from 0 to 3.0%); 500 ppm F; 1100 ppm F; and a commercial toothpaste (1100 ppm F). After pH cycling, surface and cross-sectional hardness, as well as F present in the enamel were determined. The demineralization depth was analyzed using polarized light microscopy. The variables were subjected to 1-way ANOVA, followed by Student-Newman-Keuls' test (p < 0.05).Results: In the absence of fluoride, 0.5% HMP promoted the lowest mineral loss and its effect was similar to that of a 250 ppm F toothpaste (p > 0.05). The combination of 0.5% HMP and 250 ppm F resulted in lower mineral loss (p < 0.05) and similar lesion depth when compared to the 1100 ppm F toothpaste (p > 0.05).Conclusion: To conclude, the combination of 0.5% HMP and 250 ppm fluoride in a toothpaste has a similar inhibitory effect on enamel demineralization in vitro when compared to a toothpaste containing 1100 ppm F.Clinical significance: The anticaries effect of toothpaste containing 250 ppm F combined with 0.5% HMP was similar to that of a 1100 ppm F toothpaste, despite the 4-fold difference in F concentration. Although such effects still need to be demonstrated in clinical studies, it may be a viable alternative for preschool children. (C) 2013 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study aims to characterize the microstructure of the complex phase steel (CP). Using the conventional and colored metallographic analysis with 3% Nital etchant, sodium metabisulfite 10% and LePera. Techniques were applied in this work of optical microscopy, using, besides the lighting in bright field, dark field illumination of the reverse contrast in bright field illumination, the method of polarized light, which generates colorful contrast, providing a complementary identification phases present in the microstructure, and the system by differential interference contrast (DIC). The results obtained by metallography CP indicates that the steel has a microstructure composed of ferrite, retained austenite, bainite and martensite and precipitates arranged in a refined and complex morphology. Besides bright field illumination others' optical microscopy's techniques such as dark field illumination were applied.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Since the use of bovine instead of human dentine to evaluate cariogenic and anticariogenic substances is not well established, this in situ study was conducted. Eleven volunteers wore palatal acrylic devices containing 4 dentine slabs (2 human and 2 bovine). Sucrose solution (20%) was dripped over all slabs 4 times a day, simulating a cariogenic challenge. Dentifrice slurries, fluoridated or not, were dripped over specified dentine slabs 3 times a day to evaluate caries reduction. After 14 days, the biofilm formed on the dentine slabs was collected for microbiological analysis. In dentine, mineral loss (DeltaZ) and lesion depth (LD) were determined by cross-sectional microhardness and by polarized light microscopy, respectively. The total streptococci and mutans streptococci counts in the biofilm formed either on human or on bovine slabs, whether treated or not with fluoride dentifrice, were not statistically different. The DeltaZ and the LID values of dentine treated with fluoride dentifrice were significantly lower than the values of dentine treated with non-fluoride dentifrice. The differences in the DeltaZ and LD values between the human and bovine dentine were not statistically significant. The results suggest that bovine dentine can be used instead of human to evaluate caries development and inhibition. Copyright (C) 2003 S. Karger AG, Basel.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)