937 resultados para pitch interpolation


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to explore the potential advantages, both theoretical and applied, of preserving low-frequency acoustic hearing in cochlear implant patients. Several hypotheses are presented that predict that residual low-frequency acoustic hearing along with electric stimulation for high frequencies will provide an advantage over traditional long-electrode cochlear implants for the recognition of speech in competing backgrounds. A simulation experiment in normal-hearing subjects demonstrated a clear advantage for preserving low-frequency residual acoustic hearing for speech recognition in a background of other talkers, but not in steady noise. Three subjects with an implanted "short-electrode" cochlear implant and preserved low-frequency acoustic hearing were also tested on speech recognition in the same competing backgrounds and compared to a larger group of traditional cochlear implant users. Each of the three short-electrode subjects performed better than any of the traditional long-electrode implant subjects for speech recognition in a background of other talkers, but not in steady noise, in general agreement with the simulation studies. When compared to a subgroup of traditional implant users matched according to speech recognition ability in quiet, the short-electrode patients showed a 9-dB advantage in the multitalker background. These experiments provide strong preliminary support for retaining residual low-frequency acoustic hearing in cochlear implant patients. The results are consistent with the idea that better perception of voice pitch, which can aid in separating voices in a background of other talkers, was responsible for this advantage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The XSophe-Sophe-XeprView((R)) computer simulation software suite enables scientists to easily determine spin Hamiltonian parameters from isotropic, randomly oriented and single crystal continuous wave electron paramagnetic resonance (CW EPR) spectra from radicals and isolated paramagnetic metal ion centers or clusters found in metalloproteins, chemical systems and materials science. XSophe provides an X-windows graphical user interface to the Sophe programme and allows: creation of multiple input files, local and remote execution of Sophe, the display of sophelog (output from Sophe) and input parameters/files. Sophe is a sophisticated computer simulation software programme employing a number of innovative technologies including; the Sydney OPera HousE (SOPHE) partition and interpolation schemes, a field segmentation algorithm, the mosaic misorientation linewidth model, parallelization and spectral optimisation. In conjunction with the SOPHE partition scheme and the field segmentation algorithm, the SOPHE interpolation scheme and the mosaic misorientation linewidth model greatly increase the speed of simulations for most spin systems. Employing brute force matrix diagonalization in the simulation of an EPR spectrum from a high spin Cr(III) complex with the spin Hamiltonian parameters g(e) = 2.00, D = 0.10 cm(-1), E/D = 0.25, A(x) = 120.0, A(y) = 120.0, A(z) = 240.0 x 10(-4) cm(-1) requires a SOPHE grid size of N = 400 (to produce a good signal to noise ratio) and takes 229.47 s. In contrast the use of either the SOPHE interpolation scheme or the mosaic misorientation linewidth model requires a SOPHE grid size of only N = 18 and takes 44.08 and 0.79 s, respectively. Results from Sophe are transferred via the Common Object Request Broker Architecture (CORBA) to XSophe and subsequently to XeprView((R)) where the simulated CW EPR spectra (1D and 2D) can be compared to the experimental spectra. Energy level diagrams, transition roadmaps and transition surfaces aid the interpretation of complicated randomly oriented CW EPR spectra and can be viewed with a web browser and an OpenInventor scene graph viewer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Prepulse inhibition and facilitation of the blink reflex are said to reflect different responses elicited by the lead stimulus, transient detection and orienting response respectively. Two experiments investigated the effects of trial repetition and lead stimulus change on blink modification. It was hypothesized that these manipulations will affect orienting and thus blink facilitation to a greater extent than they will affect transient detection and thus blink inhibition. In Experiment 1 (N = 64), subjects were trained with a sequence of 12 lead stimulus and 12 blink stimulus alone presentations, and 24 lead stimulus-blink stimulus pairings. Lead interval was 120 ms for 12 of the trials and 2000 ms for the other 12. For half the subjects this sequence was followed by a change in pitch of the lead stimulus. In Experiment 2 (N = 64), subjects were trained with a sequence of 36 blink alone stimuli and 36 lead stimulus-blink stimulus pairings. The lead interval was 120 ms for half the subjects and 2000 ms for the other half. The pitch of the lead stimulus on prestimulus trials 31-33 was changed for half the subjects in each group. In both experiments, the amount of blink inhibition decreased during training whereas the amount of blink facilitation remained unchanged. Lead stimulus change had no effect on blink modification in either experiment although it resulted in enhanced skin conductance responses and greater heart rate deceleration in Experiment 2. The present results are not consistent with the notion that blink facilitation is linked to orienting whereas blink inhibition reflects a transient detection mechanism. (C) 1998 Elsevier Science B.V.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The performance of three different techniques for determining proton rotating frame relaxation rates (T1pH) in charred and uncharred woods is compared. The variable contact time (VCT) experiment is shown to over-estimate T1pH, particularly for the charred samples, due to the presence of slowly cross-polarizing C-13 nuclei. The variable spin (VSL) or delayed contact experiment is shown to overcome these problems; however, care is needed in the analysis to ensure rapidly relaxing components are not overlooked. T1pH is shown to be non-uniform for both charred and uncharred wood samples; a rapidly relaxing component (T1pH = 0.46-1.07 ms) and a slowly relaxing component (T1pH = 3.58-7.49) is detected in each sample. T1pH for each component generally decreases with heating temperature (degree of charring) and the proportion of rapidly relaxing component increases. Direct T1pH determination (via H-1 detection) shows that all samples contain an even faster relaxing component (0.09-0.24 ms) that is virtually undetectable by the indirect (VCT and VSL) techniques. A new method for correcting for T1pH signal losses in spin counting experiments is developed to deal with the rapidly relaxing component detected in the VSL experiment. Implementation of this correction increased the proportion of potential C-13 CPMAS NMR signal that can be accounted for by up to 50% for the charred samples. An even greater proportion of potential signal can be accounted for if the very rapidly relaxing component detected in the direct T1pH determination is included; however, it must be kept in mind that this experiment also detects H-1 pools which may not be involved in H-1-C-13 cross-polarization. (C) 2002 Elsevier Science (USA).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Concerns exist regarding the effect of radiation dose from paediatric pelvic CT scans and the potential later risk of radiation-induced neoplasm and teratogenic outcomes in these patients. Objective: To assess the diagnostic quality of CT images of the paediatric pelvis using either reduced mAs or increased pitch compared with standard settings. Materials and methods: A prospective study of pelvic CT scans of 105 paediatric patients was performed using one of three protocols: (1) 31 at a standard protocol of 200 mA with rotation time of 0.75 s at 120 kVp and a pitch factor approximating 1.4; (2) 31 at increased pitch factor approaching 2 and 200 mA; and (3) 43 at a reduced setting of 100 mA and a pitch factor of 1.4. All other settings remained the same in all three groups. Image quality was assessed by radiologists blinded to the protocol used in each scan. Results: No significant difference was found between the quality of images acquired at standard settings and those acquired at half the standard mAs. The use of increased pitch factor resulted in a higher proportion of poor images. Conclusions: Images acquired at 120 kVp using 75 mAs are equivalent in diagnostic quality to those acquired at 150 mAs. Reduced settings can provide useful imaging of the paediatric pelvis and should be considered as a standard protocol in these situations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work investigated listeners` sense of the temporal expression of tonal modulation. One experiment described the effects on retrospective reproductions of sudden and gradual modulations to close and distant keys. The results showed that modulations elicit time underestimations as an inverse function of interkey distances, with a major impact for sudden modulations. A proposed vectorial model - ""Expected Development Fraction"" (EDF) - describes the development of expectations when an interkey distance is traversed during a certain time interval. This expected development is longer than the perceived duration, leading to underestimation of the time.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The suprathermal particles, electrons and protons, coming from the magnetosphere and precipitating into the high-latitude atmosphere are an energy source of the Earth's ionosphere. They interact with ambient thermal gas through inelastic and elastic collisions. The physical quantities perturbed by these precipitations, such as the heating rate, the electron production rate, or the emission intensities, can be provided in solving the kinetic stationary Boltzmann equation. This equation yields particle fluxes as a function of altitude, energy, and pitch angle. While this equation has been solved through different ways for the electron transport and fully tested, the proton transport is more complicated. Because of charge-changing reactions, the latter is a set of two-coupled transport equations that must be solved: one for protons and the other for H atoms. We present here a new approach that solves the multistream proton/hydrogen transport equations encompassing the collision angular redistributions and the magnetic mirroring effect. In order to validate our model we discuss the energy conservation and we compare with another model under the same inputs and with rocket observations. The influence of the angular redistributions is discussed in a forthcoming paper.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The metallic voice is usually confused with ring or nasality by singers and nontrained listeners. who are not used to perceptual vocal analysis. They believe a metallic voice results from a rise in fundamental frequency. A diagnostic error in this aspect may lead to lowering pitch, an incorrect procedure that Could Cause vocal overload and fatigue. The purpose of this article is to Study the quality of metallic voice considering the correlation between information of the physiological and acoustic plans, based on a perceptive consensual assumption. Fiberscopic video pharyngolaryngoscopy was performed on 21 professional singers while speaking vowel [e]-in normal and metallic modes to observe muscular movements and structural changes of the velopharynx, pharynx, and larynx. Vocal samples captured simultaneously to the fiberscopic examination were acoustically analyzed. Frequency and amplitude of the first four formants (F(1), F(2), F(3), and F(4)) were extracted by means of linear predictor coefficients (LPC) Spectrum and were statistically analyzed. Vocal tract adjustments such as velar lowering, pharyngeal wall narrowing, laryngeal rise, aryepiglottic, and lateral laryngeal constrictions were frequently found: there were no significant changes in frequency and amplitude of F(1) in the metallic voiced there were significant increases in amplitudes of F(2), F(3), and F(4) and in frequency for F, metallic Voice perceived as louder was correlated to an increase ill amplitude of F(3) and F(4). Physiological adjustments of velopharynx, pharynx, and larynx are combined in characterizing the metallic voice and can be acoustically related to changes in formant pattern.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study was designed to explore the correlation between the frequency of micronuclei in Trad-MN, measured across 28 biomonitoring stations during the period comprised between 11 of May and 2 of October, 2006, and adjusted mortality rates due to cardiovascular, respiratory diseases and cancer in Sao Jose dos Campos, Brazil, an area with different sources of air pollution. For controlling purposes, mortality rate due to gastrointestinal diseases (an event less prone to be affected by air pollution) was also considered in the analysis. Spatial distribution of micronuclei frequency was determined using average interpolation. The association between health estimators and micronuclei frequency was determined by measures of Pearson`s correlation. Higher frequencies of micronuclei were detected in areas with high traffic and close to a petrochemical pole. Significant associations were detected between micronuclei frequency and adjusted mortality rate due to cardiovascular diseases (r = 0.841, p = 0.036) and cancer (r = 0.890, p = 0.018). The association between mortality due to chronic obstructive pulmonary diseases was positive but did not reach statistical significance (r = 0.640, p = 0.172), probably because of the small number of events. Gastrointestinal mortality did not exhibit significant association with micronuclei frequency. Because the small number of observations and the nature of an ecological study, the present findings must be considered with caution and considered as preliminary. Further studies, performed in different conditions of contamination and climate should be done before considering Trad-MN in the evaluation of human health risk imposed by air pollutants. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present research investigated blink startle modulation during the anticipation of pleasant, unpleasant, or neutral pictures. In Experiment 1 (N = 18), participants were presented with three different tone-picture pairings. Tones differed in pitch and were followed by pleasant, neutral or unpleasant pictures. Acoustic blink reflexes were elicited during some tones and during stimulus free intervals. Blink facilitation during tones that preceded pleasant and unpleasant pictures was larger than during the tone that preceded neutral pictures. Experiment 2 (N = 10) assessed whether this difference was due to a difference in the presentation frequency of the three conditions. No difference in blink facilitation between the conditions was found when pictures of flowers and mushrooms replaced the pleasant and unpleasant pictures, indicating that picture content was instrumental in causing the differential blink facilitation in Experiment 1. The results from Experiment 1 seem to indicate that startle modulation during the anticipation of pictorial material reflects the interest in or the arousal associated with the pictures rather than picture valence.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Time-dependent wavepacket evolution techniques demand the action of the propagator, exp(-iHt/(h)over-bar), on a suitable initial wavepacket. When a complex absorbing potential is added to the Hamiltonian for combating unwanted reflection effects, polynomial expansions of the propagator are selected on their ability to cope with non-Hermiticity. An efficient subspace implementation of the Newton polynomial expansion scheme that requires fewer dense matrix-vector multiplications than its grid-based counterpart has been devised. Performance improvements are illustrated with some benchmark one and two-dimensional examples. (C) 2001 Elsevier Science B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A scheme is presented to incorporate a mixed potential integral equation (MPIE) using Michalski's formulation C with the method of moments (MoM) for analyzing the scattering of a plane wave from conducting planar objects buried in a dielectric half-space. The robust complex image method with a two-level approximation is used for the calculation of the Green's functions for the half-space. To further speed up the computation, an interpolation technique for filling the matrix is employed. While the induced current distributions on the object's surface are obtained in the frequency domain, the corresponding time domain responses are calculated via the inverse fast Fourier transform (FFT), The complex natural resonances of targets are then extracted from the late time response using the generalized pencil-of-function (GPOF) method. We investigate the pole trajectories as we vary the distance between strips and the depth and orientation of single, buried strips, The variation from the pole position of a single strip in a homogeneous dielectric medium was only a few percent for most of these parameter variations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Resistively loaded helical antennas, used in the normal mode and horizontally polarised, are modelled using the moment method above typical lossy ground. The distributed resistive loading was adjusted to maintain a two octave bandwidth. The centre frequency of 1 m dipoles was reduced from 250 MHz for the straight resistive wire to 50 MHz for a helix of pitch 2.5 cm and diameter 5 cm. The reduction in efficiency required to maintain the bandwidth for this helix was 12 dB. This agrees reasonably with the theory for small antennas in free space. The results were also verified by comparing measurements performed on a monopole resistively loaded helical antenna in a watertank with the numerical model used elsewhere.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo deste trabalho foi determinar o efeito dos parâmetros que compõem os dentes de serra de fita na produção e qualidade da madeira serrada de eucalipto. Analisou-se o efeito de dois passos de dentes (57,15 mm e passo variado: 50,8 - 50,8 - 50,39 - 50,71 - 60,03 - 60,35 mm), de dois ângulos de ataque (26 e 270) e de duas alturas (22 e 25,4 mm) em duas classes diamétricas (25 a 34 cm e 35 e 47 cm) de clones de híbridos Eucalyptus grandis x Eucalyptus urophylla com 15 anos de idade. Não houve ganho de qualidade quando se trabalhou com passo variado. As lâminas de serra que possuíam ângulo de ataque de 270 e passo único tanto com altura do dente de 22 mm quanto com 25,4 mm geraram desvios acima da espessura-meta. A menor variação em torno da espessura-meta foi obtida quando se utilizaram lâminas de serra de ângulo de ataque de 270 e altura do dente de 25,4 mm. O maior desvio ocorreu quando o desdobro foi efetuado com passo variado e ângulo de ataque de 260. A utilização de passo variado, de modo geral, foi o que apresentou maiores desvios na espessura das tábuas em relação à espessura desejada.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O conhecimento do valor da erosividade da chuva (R) de determinada localidade é fundamental para a estimativa das perdas de solo feitas a partir da Equação Universal de Perdas de Solo, sendo, portanto, de grande importância no planejamento conservacionista. A fim de obter estimativas do valor de R para localidades onde este é desconhecido, desenvolveu-se uma rede neural artificial (RNA) e analisou-se a acurácia desta com o método de interpolação "Inverso de uma Potência da Distância" (ID). Comparando a RNA desenvolvida com o método de interpolação ID, verificou-se que a primeira apresentou menor erro relativo médio na estimativa de R e melhor índice de confiança, classificado como "Ótimo", podendo, portanto, ser utilizada no planejamento de uso, manejo e conservação do solo no Estado de São Paulo.