517 resultados para piezoelectric polyers


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The information gathered with intravascular ultrasound (IVUS) are of great value in endovascular techniques. The aim of this study was to evaluate the reliability of IVUS when measuring vessel dimensions by comparison with an established reference method. The left carotid artery was exposed in 4 pigs (45-55 kg) and two piezoelectric crystals were sutured on the adventitia in the same cross-sectional plane. The distance between them was measured either by IVUS and by sonomicrometers. The mean distance between the two crystals calculated by the sonomicrometer was 4.7+/-0.4 mm (mean systolic distance was 4.9+/-0.2 mm, mean diastolic distance was 4.6+/-0.1 mm). The mean distance between the two targets calculated by IVUS was 4. 5+/-0.2 mm (mean systolic distance was 4.6+/-0.2 mm and mean diastolic 4.4+/-0.2 mm). Regression analysis of the two series of data shows a R(2)=0.9984. IVUS measurements are an average 5% smaller than sonomicrometer measurements (3.6% up to 8.3%) and the difference is statistically significant ( p <0.05). The underestimation of IVUS measurements will affect the accuracy, and probably the long-term outcome, of endovascular procedures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Non-invasive monitoring of respiratory muscle function is an area of increasing research interest, resulting in the appearance of new monitoring devices, one of these being piezoelectric contact sensors. The present study was designed to test whether the use of piezoelectric contact (non-invasive) sensors could be useful in respiratory monitoring, in particular in measuring the timing of diaphragmatic contraction.Methods: Experiments were performed in an animal model: three pentobarbital anesthetized mongrel dogs. The motion of the thoracic cage was acquired by means of a piezoelectric contact sensor placed on the costal wall. This signal is compared with direct measurements of the diaphragmatic muscle length, made by sonomicrometry. Furthermore, to assess the diaphragmatic function other respiratory signals were acquired: respiratory airflow and transdiaphragmatic pressure. Diaphragm contraction time was estimated with these four signals. Using diaphragm length signal as reference, contraction times estimated with the other three signals were compared with the contraction time estimated with diaphragm length signal.Results: The contraction time estimated with the TM signal tends to give a reading 0.06 seconds lower than the measure made with the DL signal (-0.21 and 0.00 for FL and DP signals, respectively), with a standard deviation of 0.05 seconds (0.08 and 0.06 for FL and DP signals, respectively). Correlation coefficients indicated a close link between time contraction estimated with TM signal and contraction time estimated with DL signal (a Pearson correlation coefficient of 0.98, a reliability coefficient of 0.95, a slope of 1.01 and a Spearman's rank-order coefficient of 0.98). In general, correlation coefficients and mean and standard deviation of the difference were better in the inspiratory load respiratory test than in spontaneous ventilation tests.Conclusion: The technique presented in this work provides a non-invasive method to assess the timing of diaphragmatic contraction in canines, using a piezoelectric contact sensor placed on the costal wall.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We describe the design, calibration, and performance of surface forces apparatus with the capability of illumination of the contact interface for spectroscopic investigation using optical techniques. The apparatus can be placed in the path of a Nd-YAG laser for studies of the linear response or the second harmonic and sum-frequency generation from a material confined between the two surfaces. In addition to the standard fringes of equal chromatic order technique, which we have digitized for accurate and fast analysis, the distance of separation can be measured with a fiber-optic interferometer during spectroscopic measurements (2 Å resolution and 10 ms response time). The sample approach is accomplished through application of a motor drive, piezoelectric actuator, or electromagnetic lever deflection for variable degrees of range, sensitivity, and response time. To demonstrate the operation of the instrument, the stepwise expulsion of discrete layers of octamethylcyclotetrasiloxane from the contact is shown. Lateral forces may also be studied by using piezoelectric bimorphs to induce and direct the motion of one surface.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The report documents the development and installation of an instrumented pavement on I-80 in Iowa for the purposes of demonstration and answering current pavement questions. Its two primary objectives include documentation of the installation and verification of existing design procedures through monitoring of the continuous traffic stream reactions in the pavement. Some 120 instruments were installed in a forty foot segment of reconstructed pavement. The instruments included concrete strain gages, weldable strain gages on dowels, LVDT-deflection gages and temperature sensors in the concrete and base material. Five tubes were placed under three joints and two midslabs to measure the relative moisture and density at the interface between the pavement and base with atomic equipment. The instruments were placed ahead of the paving and over 92% of the instruments responded after paving. Planning requirements, problems encountered and costs of installation are presented. The site will use piezoelectric cables in a weigh-in-motion arrangement to trigger the data collection, a microcomputer controlled data acquisition system to analyze multiple sensors simultaneously, and telemetry to monitor the site remotely. Details provide the first time user of instrumentation with valuable information on the planning, problems, costs and coordination required to establish and operate such a site.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

With the aim of improving human health, scientists have been using an approach referred to as translational research, in which they aim to convey their laboratory discoveries into clinical applications to help prevent and cure disease. Such discoveries often arise from cellular, molecular, and physiological studies that progress to the clinical level. Most of the translational work is done using animal models that share common genes, molecular pathways, or phenotypes with humans. In this article, we discuss how translational work is carried out in various animal models and illustrate its relevance for human sleep research and sleep-related disorders.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a viscometric affinity biosensor that can potentially allow continuous multi-analyte monitoring in biological fluids like blood or plasma. The sensing principle is based on the detection of viscosity changes of a polymeric solution which has a selective affinity for the analyte of interest. The chemico-mechanical sensor incorporates an actuating piezoelectric diaphragm, a sensing piezoelectric diaphragm and a flow-resisting microchannel for viscosity detection. A free-standing Anodic Alumina Oxide (AAO) porous nano-membrane is used as selective interface. A glucose-sensitive sensor was fabricated and extensively assessed in buffer solution. The sensor reversibility, stability and sensitivity were excellent during at least 65 hours. Results showed also a good degree of stability for a long term measurement (25 days). The sensor behaviour was furthermore tested in fetal bovine serum (FBS). The obtained results for glucose sensing are very promising, indicating that the developed sensor is a candidate for continuous monitoring in biological fluids. Sensitive solutions for ionized calcium and pH are currently under development and should allow multi-analyte sensing in the near future.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work concerns the experimental study of rapid granular shear flows in annular Couette geometry. The flow is induced by continuous driving of the horizontal plate at the top of the granular bed in an annulus. The compressive pressure, driving torque, instantaneous bed height and rotational speed of the shearing plate are measured. Moreover, local stress fluctuations are measured in a medium made of steel spheres 2 and 3 mm in diameter. Both monodisperse packing and bidisperse packing are investigated to reveal the influence of size diversity in intermittent features of granular materials. Experiments are conducted in an annulus that can contain up to 15 kg of spherical steel balls. The shearing granular medium takes place via the rotation of the upper plate which compresses the material loaded inside the annulus. Fluctuations of compressive force are locally measured at the bottom of the annulus using a piezoelectric sensor. Rapid shear flow experiments are pursued at different compressive forces and shear rates and the sensitivity of fluctuations are then investigated by different means through monodisperse and bidisperse packings. Another important feature of rapid granular shear flows is the formation of ordered structures upon shearing. It requires a certain range for the amount of granular material (uniform size distribution) loaded in the system in order to obtain stable flows. This is studied more deeply in this thesis. The results of the current work bring some new insights into deformation dynamics and intermittency in rapid granular shear flows. The experimental apparatus is modified in comparison to earlier investigations. The measurements produce data for various quantities continuously sampled from the start of shearing to the end. Static failure and dynamic shearing ofa granular medium is investigated. The results of this work revealed some important features of failure dynamics and structure formation in the system. Furthermore, some computer simulations are performed in a 2D annulus to examine the nature of kinetic energy dissipation. It is found that turbulent flow models can statistically represent rapid granular flows with high accuracy. In addition to academic outcomes and scientific publications our results have a number of technological applications associated with grinding, mining and massive grain storages.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A piezoelectric detector based on a commercial quartz crystal of 3.57MHz is shown. A PTFE cell attached to the GC-column outlet holds the polymer-coated crystal, whose terminals were removed. Two TTL oscillators (reference and sensor) are used and the beating of their frequencies is monitored through a home-made counter card inserted in a microcomputer. The original thermal conductivity detector was also interfaced, but through a 12-bit analog-to-digital converter. In spite of the well-known fact that QCM has low sensitivity at high temperatures, results show significant peak deformation for low temperatures. In addition, the phenomenon is also dependent on the chemical composition of the absorbent film besides instantaneous partial pressure and chemical composition of the analyte.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Resulting from ion displacement in a solid under pressure, piezoelectricity is an electrical polarization that can be observed in perovskite-type electronic ceramics, such as PbTiO3, which present cubic and tetragonal symmetries at different pressures. The transition between these crystalline phases is determined theoretically through the bulk modulus from the relationship between material energy and volume. However, the change in the material molecular structure is responsible for the piezoelectric effect. In this study, density functional theory calculations using the Becke 3-Parameter-Lee-Yang-Parr hybrid functional were employed to investigate the structure and properties associated with the transition state of the tetragonal-cubic phase change in PbTiO3 material.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Carbon monoxide was detected and determined by a piezoelectric quartz crystal sensor coated with nickel(II)-phthalocyanine 50 % (v/v) solution in glycerine. Studies on the effect of temperature, flow rate, and some possible interferents were carried out. Calibration curves, sensor stability (lifetime) and the precision of measurements were also verified. The resulting selectivity is probably due to the coordinative binding between the electronically unsatured metal complexes and the analyte. The analytical curve is linear in the concentration range 0.10 to 1.0 % (v/v).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In general, the traditional Physics courses needs examples of the aplications of the Physics concepts in other areas such as Chemistry and Biology. This lacks tend to demotivate Chemistry and Biology students regarding to deal with Physical concepts developed in classroom. In this work, the analogy among mechanic and electric oscillators is investigated to be applied in Chemistry and Biology areas, showing to be valuable due to its aplication in techniques that aims to measure mass variation with high precision. This measure could be made in a direct or indirect way. These techniques are known as electrogravimetric techniques and they are important in biosensor aplications. Thus, this paper explores the electromechanic analogy in an interdisciplinary way involving areas like Physics, Chemistry and Biology. Based on this analogy, it is proposed an experiment that can be applied in different ways, i.e. by an basic approach or more deeper, depending on the students specific formation, in other words, Physics, Chemistry or Biology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pulsed electroacoustic (PEA) method is a commonly used non-destructive technique for investigating space charges. It has been developed since early 1980s. These days there is continuing interest for better understanding of the influence of space charge on the reliability of solid electrical insulation under high electric field. The PEA method is widely used for space charge profiling for its robust and relatively inexpensive features. The PEA technique relies on a voltage impulse used to temporarily disturb the space charge equilibrium in a dielectric. The acoustic wave is generated by charge movement in the sample and detected by means of a piezoelectric film. The spatial distribution of the space charge is contained within the detected signal. The principle of such a system is already well established, and several kinds of setups have been constructed for different measurement needs. This thesis presents the design of a PEA measurement system as a systems engineering project. The operating principle and some recent developments are summarised. The steps of electrical and mechanical design of the instrument are discussed. A common procedure for measuring space charges is explained and applied to verify the functionality of the system. The measurement system is provided as an additional basic research tool for the Corporate Research Centre of ABB (China) Ltd. It can be used to characterise flat samples with thickness of 0.2–0.5 mm under DC stress. The spatial resolution of the measurement is 20 μm.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper examines two passive techniques for vibration reduction in mechanical systems: the first one is based on dynamic vibration absorbers (DVAs) and the second uses resonant circuit shunted (RCS) piezoceramics. Genetic algorithms are used to determine the optimal design parameters with respect to performance indexes, which are associated with the dynamical behavior of the system over selected frequency bands. The calculation of the frequency response functions (FRFs) of the composite structure (primary system + DVAs) is performed through a substructure coupling technique. A modal technique is used to determine the frequency response function of the structure containing shunted piezoceramics which are bonded to the primary structure. The use of both techniques simultaneously on the same structure is investigated. The methodology developed is illustrated by numerical applications in which the primary structure is represented by simple Euler-Bernoulli beams. However, the design aspects of vibration control devices presented in this paper can be extended to more complex structures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pulseri on laite, joka tuottaa noin 10 MHz:n taajuudella olevan sähköisen pulssin, joka ohjataan kiteeseen. Kide lähettää korkeataajuuksisen ääniaallon ja toimii samalla vastaanottimena kaikuna heijastuneille ääniaalloille. Kide ja membraanikalvo ovat vedessä. Ääniaalto heijastuu takaisin suodatusmembraanikalvosta, jolla on tarkoitus erotella epäpuhtauksia. Membraanikalvo ja kide ovat millimetrin etäisyydellä toisistaan ja ääniaalloilla kestää noin 1,3 mikrosekuntia kulkea kiteestä membraanikalvon pinnalle ja siitä kaikuna takaisin kiteeseen. Saadaksemme luotettavia tuloksia ääniaallon kulkuajasta, kiteen tulee olla värähtelemättömässä tilassa silloin, kun kaikuna palaava pulssi saapuu takaisin. Työssä keskitytään kiteen vaimentamiseen mahdollisimman nopeasti lähetetyn pulssin jälkeen ja siihen liittyviin ongelmiin.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Luotiaseilla tapahtuvaan ampumaharjoitteluun on käytössä monia erilaisia maalitauluja. Perinteisesti maalitauluna on toiminut puukehikkoon kiinnitetty pahvitaulu ja osumat on todettu siihen jääneiden reikien perusteella. Nykymaailmassa kaikki kuitenkin sähköistyy ja niin käy myös maalitauluille. Tämän kandidaatintyön tarkoituksena on selvittää kirjallisuustutkimuksen sekä kokeellisen tutkimuksen avulla metallisen luotiaseille tarkoitetun osuman havaitsevan maalilaitteen käyttöön soveltuva anturointi. Kirjallisuustutkimuksen avulla selvitetään antureilta vaadittavat ominaisuudet sekä valitaan kokeellista tutkimusta varten vaihtoehdot anturoinnille. Kokeellinen tutkimus suoritetaan kahdessa osassa, ensin laboratoriossa ja myöhemmin ampumaradalla tositilanteessa. Kokeellisen tutkimuksen tarkoituksena on vertailla valittujen antureiden ominaisuuksia ja valita niistä käyttötarkoitukseen soveltuvin. Kokeellista tutkimusta varten kehitettiin kaksi eri mittausjärjestelyä, joiden todettiin soveltuvan hyvin antureiden vertailemiseen. Kokeellisessa tutkimuksessa selvitettiin kolmen piezosähköisen PVDF- eli polyvinyylideenifluoridi-anturin sekä kahden erilaisen akustisen anturin soveltuvuus maalilaitteen käyttöön. Tutkimuksen perusteella todettiin PVDF-antureiden olevan soveltuvia maalilaitteen anturointiin. Akustiset anturit eivät testa-tulla tavalla täyttäneet anturoinnille asetettuja vaatimuksia.