984 resultados para physical parameters
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A novel AC Biosusceptometry (ACB) system with thirteen sensors it was implemented and characterized in vitro using magnetic phantoms. The system presenting coils in a coaxial arrangement with one pair of excitation coil outside and thirteen pairs of detection coils inside. A first-order gradiometric configuration was utilized for optimal detection of magnetic signals. Several physical parameters such as baseline, number of turns, excitation field and diameters were studied for improvement of the signal/noise ratio. This system exhibits an enhanced sensitivity and spatial resolution, due to the higher density of sensors/area. In the future those characteristics will turn possible to obtain images of magnetic marker or tracer in the gastrointestinal tract focusing on physiological and pharmaceutical studies. ACB emerged due to its interesting nature, noninvasiveness and low cost to investigate gastrointestinal parameters and this system can contribute for more accurate interpretation of biomedical signals and images
Resumo:
Radiotherapy is a field of medical physics, which has been going through a scientific and technological advancement, it is extreme important the professionals that work in this area continuous their study to improve the quality of service provided. For it, they should know the physical principles related as well their employment in radiotherapy. The electrons have been using in therapy of superficial tumors, because they show rapid decrease of dose in depth, they don’t expose the deeper tissues to radiation. The electron therapy has replaced the surface therapy with x-ray and mold brachytherapy, and nowadays, it represents 10 to 15% of radiotherapy treatments. This study brings the definition of physical parameters used in the dosimetry of electron beam, describes the tests for quality control of linear accelerator with a electrons beam, as well the activities realized in the Radiotherapy Division, of Hospital de Clinicas, in the Universidade Estadual of Campinas, in the Clinac 2100C machine
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The treatment of a tumor with ionizing radiation is an ongoing process with well differentiated stages. These ones include the tumor diagnosis and location, the decision on the treatment strategy, the absorbed dose planning and calculation, the treatment administration, the absorbed dose verification and the evaluation of results in short and long terms. The quality of a radiotherapy procedure is closely linked to factors that may be classified as clinical, such as the diagnosis, the tumor location, the treatment strategy chosen and the continuous treatment reassessment; dosimetric or physical, such as the uncertainty in the dose calculation, its optimization and verification, the suitability of the equipment to provide a radiation beam consistent with the treatment planning; finally, others which are related to the practical application of radiotherapy treatment and the handling of the patient. In order to analyze the radiotherapy quality, one should realize that the three aspects (medical, physical or dosimetric and practical application) should be considered in a combined way. This means that numerous actions of the radiotherapists, medical physicists and technicians in radiotherapy should be held jointly and their knowledge level will significantly affect the treatment quality. In this study, the main physical parameters used in dosimetry are defined as well as determined experimentally for a linear accelerator Mevatron - MXT. With this, it is intended to provide recommendations for the physical aspects of Quality Assurance (QA) in the radiotherapy treatments, and these will usually be applied by professionals in Medical Physics. In addition to these instructions, it is recommended that additional texts are prepared to address in detail the clinical aspects of the treatments QA
Resumo:
The best way to detect breast cancer is by screening mammography. The mammography equipments are dedicated and require a rigorous quality control in order to have a good quality image and to early detect this disease. The digital equipment is relatively new in the market and there isn’t a national rule for quality control for several types of digital detectors. This study has proposed to compare two different tests manuals for quality control provided by the manufacturers of digital mammography equipments, and also compare them to the “European guidelines for quality assurance in breast cancer screening and diagnosis “(2006). The studied equipments were: Senographe 2000D from General Electric (GE) and the Hologic Selenia Lorad. Both were digital mammography equipments, the GE unit presents an indirect digital system and the other presents a direct digital system. Physical parameters of the image have been studied, such as spatial resolution, contrast resolution, noise, signal-tonoise ratio, contrast-to-noise ratio and modulation transfer function. After that, a study of the importance of quality control and the requirement to implement a Quality Assurance Program has been done. One data collection was done to compare those manual, it was done by checking which tests are indicated and the minimum frequency which they should be conducted in accordance with each manufacturer. The tests were performed by different methodologies and the results were compared. The examined tests were: the breast entrance skin dose, mean glandular dose, contrast-to-noise ratio, signal-to-noise ratio, automatic exposure control and automatic control of density, modulation transfer function, equipment resolution, homogeneity and ghost
Resumo:
This project has several objectives: To determine medium values and variations of the density, porosity, humidity, shrinkage volume and the coefficient of mass attenuation of gamma radiation of 59,6 keV of the radioisotope 241Am, using samples of equine radio, in growth and adult. The samples of bones were supplied by the Department of Pathology of University of Veterinary Medicine and Zootechnics - UNESP campus Botucatu. Bones of the paws front left of two males were used. Of each bone ten samples were removed. Those samples were prepared to just obtain compact bony fabric, being submitted to the rehearsal of determination of the density by the immersion method in water and determination of the coefficient attenuation lineal for the method of attenuation of the radiation of the 241Am, also obtaining your humidity content. Still, they were obtained new samples starting from the ground samples and verified the density of the particles present in that, obtaining the medium value of the coefficient of mass attenuation. The results showed the medium values and significant statistical variations of the density, porosity, humidity, shrinkage volume and coefficient of mass attenuation of gamma radiation of 59, 6 keV of the radioisotope 241Am in the samples, establishing some relationships between of the certain physical parameters with biological aspects and possible existent influences between them
Resumo:
The purpose of this work is to provide quality control requirements and security in dental x-rays in order to obtain good quality image which allows the correct diagnosis, which reduces the dose to the patient, mainly due to the repetition of tests, and decreasing cost. The requirements apply to related activities to quality control and procedures using ionizing radiation for diagnostic imaging in dentistry by evaluating a minimum set of parameters to be tested or verified. Quality control follows the Ordinance No. 453 of the Ministry of Health of 06.01.1998, SS Resolution No. 625 of 12.14.1994 and Resolution No. 64 of the Health Surveillance Center – Department of Health of Sao Paulo and National Health Surveillance Agency – Ministry of Health of Brazil. This study was conducted in the city of Marilia, Sao Paulo, along with the Company P&R Consulting and Medical Physics, in a dental clinic of the University UNIMAR in the x-ray equipment used on that site. The physical parameters of the device were tested with the aid of ionization chambers to measure rates of radiation, electrometer to measure rates of time, kV and doses, radiographic films and positioning devices. Finally, this work demonstrates the need and importance of quality control, which one ensures the proper use of x-ray machines, maintaining efficiency and at the same time it reduces the risks to the patient, to the dentist and to the general public
Resumo:
The practice of regular physical activity has been considered a protective factor against the degenerative processes of the body, acting as a promoter of health, especially for risk groups such as obese and resistant groups exercise adherence as among the intellectually disabled (ID) . This study involved the administration of a training protocol and the physical parameters of longitudinal health in a subject about 43 years, intellectually deficient, hypertensive, obese and with a strong predisposition to develop diabetes and heart disease. The main objective of long-term program was to reduce body weight and normalize blood pressure (BP) after the student's physical activity and preferentially interfere with BP values at rest (ie before the daily schedule). The other objective was to improve general physical fitness. The protocol involved four meetings per week lasting one hour, in addition to participation in the program PROEFA (twice a week with sessions of one hour each), totaling 57 sessions spread over five months. The evaluation protocol included in each session the following tests: blood pressure measurements and heart rate, and amount of physical activity recorded via pedometer. Tests applied before and after the training included: anthropometric assessment, agility test, flexibility test, test drive through vertical and horizontal jumps and endurance to the test bench. The mass (kg) and BMI corresponded to the initial values of 127.7 kg and 42.05 kg m-2, and 5 months after 113.2 kg and 37.48 kg m-2, respectively. The waist-hip ratio was close to 1 after the intervention and this value corresponded to 0.98. For the test of agility (shuttle run) was not found improvement in performance. To test the values of the horizontal jump in pre-test were 52 cm and 56 cm post-test, vertical jump has been improved and...(Complete abstract click electronic access below)
Resumo:
In this work we study some topics of Celestial Mechanics, namely the problem of rigid body rotation and “spin-orbit” resonances. Emphasis is placed on the problem formulation and applications to some exoplanets with physical parameters (e.g. mass and radius) compatible with a terrestrial type constitution (e.g. rock) belonging to multiple planetary systems. The approach is both analytical and numerical. The analytical part consists of: i) the deduction of the equation of motion for the rotation problem of a spherical body with no symmetry, disturbed by a central body; ii) modeling the same problem by including a third-body in the planet-star system; iii) formulation of the concept of “spin-orbit” resonance in which the orbital period of the planet is an integer multiple of the rotation’s period. Topics of dynamical systems (e.g. equilibrium points, chaos, surface sections, etc.) will be included at this stage. In the numerical part simulations are performed with numerical models developed in the previous analytical section. As a first step we consider the orbit of the planet not perturbed by a third-body in the star-planet system. In this case the eccentricity and orbital semi-major axis of the planet are constants. Here the technique of surface sections, widely used in dynamical systems are applied. Next, we consider the action of a third body, developing a more realistic model for planetary rotation. The results in both cases are compared. Since the technique of disturbed surface sections is no longer applicable, we quantitatively evaluate the evolution of the characteristic angles of rotation (e.g. physical libration) by studying the evolution of individual orbits in the dynamically important regions of phase space, the latter obtained in the undisturbed case
Resumo:
In radiation theraphy with electron beam, the electrons are produced in linear accelerators, and energy the most used have between 4MeV and 20MeV. Generally, the treatments are done for superficial injuries, because the low penetration of these particles. In this work a system for calculation of monitor units (U.M.) for cases of treatments with electron beam was developed. The Excel program of Microsoft was used and is easily found in the operational system of the personal microcomputers. In the Excel has been inserted the pertinent data of the linear accelerator of Varian, model 2100C, used in the Service of radiation theraphy of the Hospital of the Clinics of the College of Medicine of the UNESP of Botucatu. For some values of the physical parameters, such as: factors field and factors calibration, not supplied in the tests of acceptance of the machine, still proceeded calculations from interpolation and extrapolation. The mathematical formulas for automatic search of these and others factors used in the calculations of the determination of the U.M had been developed in agreement available routines in Excel. For this the functions had been used the function IF (that it imposes search condition) and the PROCH (that looks a value in a column from determined line), beyond the basic functions of addition, multiplication and division. It is intended to optimize the routine of the Services of radiation theraphy that perform through eletrontheraphy procedures, speeding the calculations and minimizing the occurrence of errors and uncertainties deriving of the maken a mistake manipulation of the parameters gotten in tables of data of electron beams
Resumo:
The pharmaceutical innovations, such as the use of polymers to control drug release, create possibilities for a better action of the drug in the body, which causes a a more effective therapeutic effect and a safer treatment for the patient. In this work, were prepared and characterized matrix tablets of hydroxypropylmethylcellulose (HPMC) containing nimesulide as model drug to evaluate the performance as a controlled release system. HPMC, a cellulose ester, is a hydrophilic polymer that undergoes swelling, i.e., absorbs water and forms a gel layer controlling drug release. The characterization of powders was performed by analysis of particle size and morphology, density, compressibility index determination, flow properties and determination of swelling profile. The tablets were evaluated according to their physical parameters of quality and to the in vitro release of nimesulide, as well as the analysis of the mechanisms of drug release by appropriate mathematical models. The set of results showed that the HPMC/Nimesulide mixture exhibited satisfactory physical characteristics (size, shape, density and flow). The release profile demonstrated an effective control upon drug release in enteric environment and presented more correlation with Korsmeyer-Peppas’ and Weibull’s mathematical models, indicating that the release of nimesulide occurs through the relaxation of the polymer chains
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The X-ray fluorescence analysis (XRF) is an important technique for the qualitative and quantitative determination of chemical components in a sample. It is based on measurement of the intensity of the emitted characteristic radiation by the elements of the sample, after being properly excited. One of the modalities of this technique is the total reflection x-ray fluorescence (TXRF). In TXRF, the angle of refraction of the incident beam tends to zero and the refracted beam is tangent to the sample-support interface. Thus, there is a minimum angle of incidence that there is no refracted beam and all the incident radiation undergoes total reflection. As it is implemented in very small samples, in a film format, self-absorption effects should not very relevant. In this study, we evaluated the feasibility of using code MCNPX (Monte Carlo N - Particle eXtended), to simulate a measure implemented by the TXRF technique. In this way, it was verified the quality of response of a system by TXRF spectroscopy using synchrotron radiation as excitation beam for a simple setup, by retrieving the characteristic energies and the concentrations of the elements in the sample. The steps of data processing, after obtaining the excitation spectra, were the same as in a real experiment and included the obtaining of the sensitivity curve for the simulated system. The agreement between the theoretical and simulated values of Ka characteristic energies for different elements was lower than 1 % .The obtained concentration of the elements of the sample had high relatively errors ( between 6 and 60 % ) due mainly to lack of knowing about some realistic physical parameters of the sample , such as density . In this way, this result does not preclude the use of MCNPX code for this type of application