950 resultados para performance characteristics


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Nuclear medicine is a medical specialty related to imagery that deals with imaging techniques, diagnosis and therapy, allowing observing the physiological state of tissues noninvasively by marking the molecules participating of these physiological processes with radioactive isotopes, thus creating the called radionuclides. The image of a radionuclide is one of the most important applications of radioactivity in nuclear medicine. The equipment’s of nuclear medicine imaging use the principle of radiation detection, turning it into an electrical signal which, through specific algorithms, allows forming tomographic images that provide information about the functional status of organs. New detection systems have been developed for tomographic acquisitions using solid state detectors. These devices use crystals of cadmium zinc telluride (CdZnTe). Some of the advantages of this detector are a significant improvement of signal to noise ratio, the increased spectral and spatial resolution, which in sum, result in greater clarity of the images obtained, opening new perspectives for imaging protocols previously unattainable. In contrast, all other gamma-cameras equipped with vacuum tubes have remained relatively unchanged for nearly fifty years. In these gamma-cameras, the images are obtained using two steps significantly less efficient: the gamma rays are converted to light through a first device, and then the light is converted into an electrical signal through a second device. One of functions the Medical Physicist is related to the quality control of equipment. This control ensures that the information and images provided are true and thus credible to be used in medical reports. To perform this type of analysis the physicist must understand the performance characteristics and operation of all equipment of the department concerned; besides, in the absence of specific legislation, proposing...(Complete abstract click electronic access below)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Genética e Melhoramento Animal - FCAV

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Eletronicalceramics are used in many applications such as: multilayer capacitor, transducer, pyroelectric sensors and electrooptic devices. In recent years there has been a growing demand for eletronicalceramics with better performance and functionality. This demand has accelerated the development of synthesis techniques to produce powders with well-defined particle size, shape and crystallinity. The eletronicalceramics in the form of bulk are determined by their performance characteristics of the powders used and the preparation process. So, physical and chemical properties of powders, such as chemical control of stoichiometry, purity, homogeneity, particle size and shape should be observed when choosing the methods of synthesis. Among the techniques used so far, the polymeric precursor method, also known as Pechini, has been considered ideal for the preparation of nanosized powders. Thus, this research project aims to use the polymeric precursor method to prepare powders of lithium tantalate and lanthanum tantalate, with good chemical stability. In this aspect is proposed to investigate the effects of variation of the concentration of europium about the properties of tantalate because doping with Eu3 + indicates that they may occupy different sites in the crystal structure, as in the case of LiTaO3. Effects of things like occupation sites, stability of phases and formation temperature have been previously investigated by the group, which motivated the formulation of this project. Our proposal aims to introduce the Eu3 + LaTaO4 and LiTaO3 and study the structural and optical properties of the powders obtained by Pechini method, as well as correlate these studies with the electrical properties of the material, mainly the Ironelectricty Hysteresis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Genética e Melhoramento Animal - FCAV

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A polyacrylamide hydrogel containing the Chelex-100 resin has traditionally been used as the binding agent for the diffusion gradients in thin films (DGT) technique. The Chelex-100 resin, although important for the determination of various transition metals, is unsatisfactory for the determination of alkaline earth metals, particularly Ba. In this paper, a cellulose membrane, treated with phosphate (P81 membrane), was evaluated as a binding agent for DGT devices for the determination of Ba in produced formation water (PEW) samples. In addition, diffusive layers of filter paper (cellulose) were tested to diffuse Ba through the DGT devices. Experiments to evaluate the key variables of the technique (pH, deployment time, and ionic strength/salinity) were performed. The Ba sampled by these DGT devices was measured using inductively coupled plasma optical emission spectrometry. Aiming to generate information (related to bioavailability of Ba) on the reuse of PEW for irrigation, the determination of Ba in onshore and offshore samples was performed. The new approach was effective for determination of Ba in onshore samples. To determine Ba in offshore samples, it was necessary to use an alternative calibration procedure due to the high NaCl concentration in these samples. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Lo studio effettuato pone le sue basi sulla ricerca di materiali stradali che combinino ad elevati standard prestazionali, la riduzione dell’impatto ambientale in fase realizzativa e manutentiva. In particolare il seguente lavoro si occupa dello studio di 7 leganti modificati con polimeri ed additivati con cere. I primi infatti conferiscono alla miscela maggiore elastoplasticità, incrementandone la durabilità e la resistenza a fatica. Nei secondi la presenza del materiale paraffinico contribuisce a ridurre la viscosità del bitume, consentendo un notevole abbassamento della temperatura di produzione e stesa della miscela. Numerosi studi hanno dimostrato che le caratteristiche meccaniche della pavimentazione sono fortemente influenzate dal grado di ossidazione delle componenti organiche del bitume, ovvero dal fenomeno dell’invecchiamento o aging. Pertanto allo studio reologico del bitume, si sono affiancate prove di simulazione dell’ invecchiamento nel breve e lungo termine. In fase di ricerca sperimentale si sono analizzati i leganti modificati ed additivati secondo la teoria della viscoelasticità, simulando le reali condizioni di carico ed invecchiamento alle quali il bitume è sottoposto. Tutte le prove di caratterizzazione reologica avanzata sono state effettuate mediante l’utilizzo del DSR (Dynamic Shear Rheometer - UNI EN 14770 ) in varie configurazioni di prova e l’invecchiamento a breve termine è stato simulato mediante RTFOT (Rolling thin film oven test -UNI EN 12607-1). Si è proposto inoltre una nuova procedura di aging invecchiando il bitume alla temperatura di Twork, ovvero a quel valore della temperatura tale per cui, in fase di messa in opera, si avrà una distribuzione molecolare omogenea del modificante all’interno del bitume.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background Surgical risk scores, such as the logistic EuroSCORE (LES) and Society of Thoracic Surgeons Predicted Risk of Mortality (STS) score, are commonly used to identify high-risk or “inoperable” patients for transcatheter aortic valve implantation (TAVI). In Europe, the LES plays an important role in selecting patients for implantation with the Medtronic CoreValve System. What is less clear, however, is the role of the STS score of these patients and the relationship between the LES and STS. Objective The purpose of this study is to examine the correlation between LES and STS scores and their performance characteristics in high-risk surgical patients implanted with the Medtronic CoreValve System. Methods All consecutive patients (n = 168) in whom a CoreValve bioprosthesis was implanted between November 2005 and June 2009 at 2 centers (Bern University Hospital, Bern, Switzerland, and Erasmus Medical Center, Rotterdam, The Netherlands) were included for analysis. Patient demographics were recorded in a prospective database. Logistic EuroSCORE and STS scores were calculated on a prospective and retrospective basis, respectively. Results Observed mortality was 11.1%. The mean LES was 3 times higher than the mean STS score (LES 20.2% ± 13.9% vs STS 6.7% ± 5.8%). Based on the various LES and STS cutoff values used in previous and ongoing TAVI trials, 53% of patients had an LES ≥15%, 16% had an STS ≥10%, and 40% had an LES ≥20% or STS ≥10%. Pearson correlation coefficient revealed a reasonable (moderate) linear relationship between the LES and STS scores, r = 0.58, P < .001. Although the STS score outperformed the LES, both models had suboptimal discriminatory power (c-statistic, 0.49 for LES and 0.69 for STS) and calibration. Conclusions Clinical judgment and the Heart Team concept should play a key role in selecting patients for TAVI, whereas currently available surgical risk score algorithms should be used to guide clinical decision making.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A liquid chromatography tandem mass spectrometry (LC-MS/MS) confirmatory method for the simultaneous determination of nine corticosteroids in liver, including the four MRL compounds listed in Council Regulation 37/2010, was developed. After an enzymatic deconjugation and a solvent extraction of the liver tissue, the resulting solution was cleaned up through an SPE Oasis HLB cartridge. The analytes were then detected by liquid chromatography-negative-ion electrospray tandem mass spectrometry, using deuterium-labelled internal standards. The procedure was validated as a quantitative confirmatory method according to the Commission Decision 2002/657/EC criteria. The results showed that the method was suitable for statutory residue testing regarding the following performance characteristics: instrumental linearity, specificity, precision (repeatability and intra-laboratory reproducibility), recovery, decision limit (CCα), detection capability (CCβ) and ruggedness. All the corticosteroids can be detected at a concentration around 1 μg kg(-1); the recoveries were above 62% for all the analytes. Repeatability and reproducibility (within-laboratory reproducibility) for all the analytes were below 7.65% and 15.5%, respectively.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work presents an innovative integration of sensing and nano-scaled fluidic actuation in the combination of pH sensitive optical dye immobilization with the electro-osmotic phenomena in polar solvents like water for flow-through pH measurements. These flow-through measurements are performed in a flow-through sensing device (FTSD) configuration that is designed and fabricated at MTU. A relatively novel and interesting material, through-wafer mesoporous silica substrates with pore diameters of 20 -200 nm and pore depths of 500 µm are fabricated and implemented for electro-osmotic pumping and flow-through fluorescence sensing for the first time. Performance characteristics of macroporous silicon (> 500 µm) implemented for electro-osmotic pumping include, a very large flow effciency of 19.8 µLmin-1V-1 cm-2 and maximum pressure effciency of 86.6 Pa/V in comparison to mesoporous silica membranes with 2.8 µLmin-1V-1cm-2 flow effciency and a 92 Pa/V pressure effciency. The electrical current (I) of the EOP system for 60 V applied voltage utilizing macroporous silicon membranes is 1.02 x 10-6A with a power consumption of 61.74 x 10-6 watts. Optical measurements on mesoporous silica are performed spectroscopically from 300 nm to 1000 nm using ellipsometry, which includes, angularly resolved transmission and angularly resolved reflection measurements that extend into the infrared regime. Refractive index (n) values for oxidized and un-oxidized mesoporous silicon sample at 1000 nm are found to be 1.36 and 1.66. Fluorescence results and characterization confirm the successful pH measurement from ratiometric techniques. The sensitivity measured for fluorescein in buffer solution is 0.51 a.u./pH compared to sensitivity of ~ 0.2 a.u./pH in the case of fluorescein in porous silica template. Porous silica membranes are efficient templates for immobilization of optical dyes and represent a promising method to increase sensitivity for small variations in chemical properties. The FTSD represents a device topology suitable for application to long term monitoring of lakes and reservoirs. Unique and important contributions from this work include fabrication of a through-wafer mesoporous silica membrane that has been thoroughly characterized optically using ellipsometry. Mesoporous silica membranes are tested as a porous media in an electro-osmotic pump for generating high pressure capacities due to the nanometer pore sizes of the porous media. Further, dye immobilized mesoporous silica membranes along with macroporous silicon substrates are implemented for continuous pH measurements using fluorescence changes in a flow-through sensing device configuration. This novel integration and demonstration is completely based on silicon and implemented for the first time and can lead to miniaturized flow-through sensing systems based on MEMS technologies.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A tandem mass spectral database system consists of a library of reference spectra and a search program. State-of-the-art search programs show a high tolerance for variability in compound-specific fragmentation patterns produced by collision-induced decomposition and enable sensitive and specific 'identity search'. In this communication, performance characteristics of two search algorithms combined with the 'Wiley Registry of Tandem Mass Spectral Data, MSforID' (Wiley Registry MSMS, John Wiley and Sons, Hoboken, NJ, USA) were evaluated. The search algorithms tested were the MSMS search algorithm implemented in the NIST MS Search program 2.0g (NIST, Gaithersburg, MD, USA) and the MSforID algorithm (John Wiley and Sons, Hoboken, NJ, USA). Sample spectra were acquired on different instruments and, thus, covered a broad range of possible experimental conditions or were generated in silico. For each algorithm, more than 30,000 matches were performed. Statistical evaluation of the library search results revealed that principally both search algorithms can be combined with the Wiley Registry MSMS to create a reliable identification tool. It appears, however, that a higher degree of spectral similarity is necessary to obtain a correct match with the NIST MS Search program. This characteristic of the NIST MS Search program has a positive effect on specificity as it helps to avoid false positive matches (type I errors), but reduces sensitivity. Thus, particularly with sample spectra acquired on instruments differing in their Setup from tandem-in-space type fragmentation, a comparably higher number of false negative matches (type II errors) were observed by searching the Wiley Registry MSMS.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Recent treatment planning studies have demonstrated the use of physiologic images in radiation therapy treatment planning to identify regions for functional avoidance. This image-guided radiotherapy (IGRT) strategy may reduce the injury and/or functional loss following thoracic radiotherapy. 4D computed tomography (CT), developed for radiotherapy treatment planning, is a relatively new imaging technique that allows the acquisition of a time-varying sequence of 3D CT images of the patient's lungs through the respiratory cycle. Guerrero et al. developed a method to calculate ventilation imaging from 4D CT, which is potentially better suited and more broadly available for IGRT than the current standard imaging methods. The key to extracting function information from 4D CT is the construction of a volumetric deformation field that accurately tracks the motion of the patient's lungs during the respiratory cycle. The spatial accuracy of the displacement field directly impacts the ventilation images; higher spatial registration accuracy will result in less ventilation image artifacts and physiologic inaccuracies. Presently, a consistent methodology for spatial accuracy evaluation of the DIR transformation is lacking. Evaluation of the 4D CT-derived ventilation images will be performed to assess correlation with global measurements of lung ventilation, as well as regional correlation of the distribution of ventilation with the current clinical standard SPECT. This requires a novel framework for both the detailed assessment of an image registration algorithm's performance characteristics as well as quality assurance for spatial accuracy assessment in routine application. Finally, we hypothesize that hypo-ventilated regions, identified on 4D CT ventilation images, will correlate with hypo-perfused regions in lung cancer patients who have obstructive lesions. A prospective imaging trial of patients with locally advanced non-small-cell lung cancer will allow this hypothesis to be tested. These advances are intended to contribute to the validation and clinical implementation of CT-based ventilation imaging in prospective clinical trials, in which the impact of this imaging method on patient outcomes may be tested.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The primary isolation of a Mycobacterium sp. of the Mycobacterium tuberculosis complex from an infected animal provides a definitive diagnosis of tuberculosis. However, as Mycobacterium bovis and Mycobacterium caprae are difficult to isolate, particularly for animals in the early stages of disease, success is dependent on the optimal performance of all aspects of the bacteriological process, from the initial choice of tissue samples at post-mortem examination or clinical samples, to the type of media and conditions used to cultivate the microorganism. Each step has its own performance characteristics, which can contribute to sensitivity and specificity of the procedure, and may need to be optimized in order to achieve the gold standard diagnosis. Having isolated the slow-growing mycobacteria, species identification and fine resolution strain typing are keys to understanding the epidemiology of the disease and to devise strategies to limit transmission of infection. New technologies have emerged that can now even discriminate different isolates from the same animal. In this review we highlight the key factors that contribute to the accuracy of bacteriological diagnosis of M. bovis and M. caprae, and describe the development of advanced genotyping techniques that are increasingly used in diagnostic laboratories for the purpose of supporting detailed epidemiological investigations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE Thoracic ultrasound (TUS) has been successfully used in the diagnosis of community-acquired pneumonia. Little is known about its diagnostic potential in ventilator-associated pneumonia (VAP). The purpose of this study was to systematically describe the morphology and temporal changes of sonographic patterns in mechanically ventilated patients and to evaluate the diagnostic performance characteristics of TUS-based VAP diagnoses. MATERIALS AND METHODS Patients who were placed on invasive ventilation for reasons other than pneumonia and who were considered at risk for the development of VAP received daily TUS examinations while being closely monitored for the development of pneumonia. RESULTS Fifty-seven patients were studied. The incidence of VAP was 21.1%. Sonographic patterns of reduced or absent lung aeration were found in 64.2% of examinations. The sonographic pattern of lung consolidation with either dynamic or static air bronchograms was 100% sensitive and 60% specific for VAP in those patients who developed clinical signs and symptoms compatible with pneumonia. The pretest and posttest probabilities were 0.38 and 0.6, respectively. CONCLUSIONS Sonographic patterns of abnormal aeration are frequently observed in mechanically ventilated patients. If sonographic lung consolidation with either static or dynamic air bronchograms is absent, VAP is highly unlikely. The presence of these sonographic patterns in patients with signs and symptoms suggestive of pneumonia significantly increases the probability of VAP.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Abortion in ruminants is a major cause of economic loss worldwide, and the management and control of outbreaks is important in limiting their spread, and in preventing zoonotic infections. Given that rapid and accurate laboratory diagnosis is central to controlling abortion outbreaks, the submission of tissue samples to laboratories offering the most appropriate tests is essential. Direct antigen and/or DNA detection methods are the currently preferred methods of reaching an aetiological diagnosis, and ideally these results are confirmed by the demonstration of corresponding macroscopic and/or histopathological lesions in the fetus and/or the placenta. However, the costs of laboratory examinations may be considerable and, even under optimal conditions, the percentage of aetiological diagnoses reached can be relatively low. This review focuses on the most commonly occurring and important abortifacient pathogens of ruminant species in Europe highlighting their epizootic and zoonotic potential. The performance characteristics of the various diagnostic methods used, including their specific advantages and limitations, are discussed.