1000 resultados para optical
Resumo:
A series of 2′-5′-oligoguanylic acids are prepared by reacting G(cyclic)p with takadiastase T1 ribonuclease and separating the products chromatographically. The 3′-5′-oligoguanylic acids are obtained by separating the products of alkaline degradation of 3′-5′-poly(G). The optical rotatory dispersion and hypochromism of both 2′-5′- and 3′-5′-oligoguanylic acids are studied at two different pH. The optical rotatory dispersion spectrum of 2′-5′-GpG is significantly different from that of 3′-5′-GpG. The magnitude of rotation of the long-wavelength peak of 2′-5′-GpG is larger than that of 3′-5′-GpG. This finding contradicts the explanation that the extra stability and more intense circular dichroism band of other 3′-5′-dinucleoside monophosphates is due to H-bond formation between 2′-OH and either the base or the phosphate oxygen. The end phosphate group has a marked effect on the spectrum of GpG between 230 and 250 mμ. In addition the optical rotatory dispersion spectra of 2′-5′ exhibit strong pH, temperature, and solvent dependence between 230 and 250 mμ. ΔH and AS for order ⇌ disorder transition is estimated to be 9.7 kcal/mole and 35.2 eu, respectively. The optical rotatory dispersion spectra of guanine-rich oligoribonucleotides, GpGpC, GpGpU, GpGpGpC, and GpGpGpU are compared to the calculated optical rotatory dispersion from the semiempirical expression of Cantor and Tinoco, using measured optical rotatory dispersion of dimers. Contrary to previous studies, agreement is found not at all satisfactory. However, optical rotatory dispersion of 3′-5′-GpGpGpC and GpGpGpU can be estimated from the semiempirical expression, if a next-nearest interaction parameter is introduced empirically. Such interaction parameter can be calculated from the measured properties of trinucleotide sequences like GpGpG, GpGpC, and GpGpU, assuming that only the nearest-neighbor interaction is important. The optical rotatory dispersion of single-stranded poly(G) is also predicted. The importance of syn-anti equilibrium and next-nearest-neighbor interaction in oligoguanylic acids is suggested as a probable explanation.
Resumo:
From symmetry considerations and using generalized Onsager relations, it is shown that 66 of the 90 magnetic classes, consisting of 29 single colour and 37 double colour ones, can exhibit what may be called the strain gyrotropic rotation. Similarly, 69 of the 90 magnetic classes, consisting of 21 single colour and 48 double colour ones, can exhibit what may be called the strain gyrotropic birefringence. A crystal in the class m3 or m3 m is interesting as it can exhibit strain gyrotropic rotation despite its being cubic and incapable of exhibiting gyrotropic rotation in the unstressed state. Similarly, a crystal in the class m3 m, is interesting as it can exhibit strain gyrotropic birefringence despite its being cubic and incapable of exhibiting gyrotropic birefringence in the unstressed state.
Resumo:
Observations at a series of temperatures of the changes in viscosities and depolarization factors of 1% and 18% solutions of calcium stearate in cetane to which varying amounts of water have been added can be interpreted in terms of the existence of anisometric micelles. In general, changes in the size of the micelles inferred from values of ρh agree with those deduced from the viscosity data. The correlation between anisometry of micelles from rheological and optical observations is much poorer in the case of ρν, presumably because of the difficulty in differentiating the contribution of anisometry and anisotropy to ρν.
Resumo:
Subtraction of one complex spatial function from another can be accomplished holographically by shifting the phase of the reference beam by pi between the two exposures. A simple and reliable system for this purpose, which makes use of the fact that the beam from a gas laser is usually plane-polarized, is described, and its application to obtain the equivalent of a dark field with the frozen-fringe technique in holographic interferometry is demonstrated.
Resumo:
TiO2 thin films have been deposited on glass and indium tin oxide (ITO) coated glass substrates by sol-gel technique. the influence of annealing temperature on the structural , morphological and optical properties has been examined. X-ray diffraction (XRD) results reveal the amorphous nature of the as-deposited film whereas the annealed films are found to be in the crystalline anatase phase. The surface morphology of the films at different annealing temperatures has been examined by atomic force microscopy (AFM). The in situ surface morphology of the as-deposited and annealed TiO2 films has also been examined by optical polaromicrograph (OPM). TiO2 films infatuated different structural and surface features with variation of annealing temperature. The optical studies on these films suggest their possible usage in sun-shielding applications.
Resumo:
Optically clear glasses of various compositions in the system (100-x)Li2B4O7 center dot x(Ba5Li2Ti2Nb8O30) (5 <= x <= 20, in molar ratio) were fabricated by splat quenching technique. Controlled heat-treatment of the as-quenched glasses at 500 degrees C for 8 h yielded nanocrystallites embedded in the glass matrix. High Resolution Transmission Electron Microscopy (HRTEM) of these samples established the composition of the nano-crystallites to be that of Ba5Li2Ti2Nb8O30. B-11 NMR studies revealed the transformation of BO4 structural units into BO3 units owing to the increase in TiO6 and NbO6 structural units as the composition of Ba5Li2Ti2Nb8O30 increased in the glass. This, in turn, resulted in an increase in the density of the glasses. The influence of the nominal composition of the glasses and glass nanocrystal composites on optical band gap (E-opt), Urbach energy (Delta E), refractive index (n), molar refraction (R-m), optical polarizability (alpha(m)) and third order non-linear optical susceptibility (chi(3)) were studied.
Resumo:
This is the second part of a two part review on the state-of-the-art in holographic optical elements (HOEs). The aspects of fabrication, evaluation, and applications of HOEs, are discussed in this part. It details the direction of future efforts towards finding work-horse type recording media, developing new methods for the evaluation of HOE, and identifying the areas of application where HOEs are to be considered as indispensable components/tools. Finally a summary of all the suggestions for future work made in the two parts is displayed in Table 2 of this part of the review.
Resumo:
A state-of-the-art review on holographic optical elements (HOE) is presented in two parts. In Part I a conceptual overview and an assessment of the current status on the design of HOE have been included. It is pointed out that HOE development based on the use of squeezed light, speckle, non-linear recording, comparative studies between optics and communication approaches, are some of the promising directions for future research in this vital area of photonics.
Resumo:
We propose an effective elastography technique in which an acoustic radiation force is used for remote palpation to generate localized tissue displacements, which are directly correlated to localized variations of tissue stiffness and are measured using a light probe in the same direction of ultrasound propagation. The experimental geometry has provision to input light beam along the ultrasound propagation direction, and hence it can be prealigned to ensure proper interception of the focal region by the light beam. Tissue-mimicking phantoms with homogeneous and isotropic mechanical properties of normal and malignant breast tissue are considered for the study. Each phantom is insonified by a focusing ultrasound transducer (1 MHz). The focal volume of the transducer and the ultrasound radiation force in the region are estimated through solving acoustic wave propagation through medium assuming average acoustic properties. The forward elastography problem is solved for the region of insonification assuming the Lame's parameters and Poisson's ratio, under Dirichlet boundary conditions which gives a distribution of displacement vectors. The direction of displacement, though presented spatial variation, is predominantly towards the ultrasound propagation direction. Using Monte Carlo (MC) simulation we have traced the photons through the phantom and collected the photons arriving at the detector on the boundary of the object in the direction of ultrasound. The intensity correlations are then computed from detected photons. The intensity correlation function computed through MC simulation showed a modulation whose strength is found to be proportional to the amplitude of displacement and inversely related to the storage (elastic) modulus. It is observed that when the storage modulus in the focal region is increased the computed displacement magnitude, as indicated by the depth of modulation in the intensity autocorrelation, decreased and the trend is approximately exponential.
Resumo:
In this paper, we present a wavelet - based approach to solve the non-linear perturbation equation encountered in optical tomography. A particularly suitable data gathering geometry is used to gather a data set consisting of differential changes in intensity owing to the presence of the inhomogeneous regions. With this scheme, the unknown image, the data, as well as the weight matrix are all represented by wavelet expansions, thus yielding the representation of the original non - linear perturbation equation in the wavelet domain. The advantage in use of the non-linear perturbation equation is that there is no need to recompute the derivatives during the entire reconstruction process. Once the derivatives are computed, they are transformed into the wavelet domain. The purpose of going to the wavelet domain, is that, it has an inherent localization and de-noising property. The use of approximation coefficients, without the detail coefficients, is ideally suited for diffuse optical tomographic reconstructions, as the diffusion equation removes most of the high frequency information and the reconstruction appears low-pass filtered. We demonstrate through numerical simulations, that through solving merely the approximation coefficients one can reconstruct an image which has the same information content as the reconstruction from a non-waveletized procedure. In addition we demonstrate a better noise tolerance and much reduced computation time for reconstructions from this approach.
Resumo:
Reconstructions in optical tomography involve obtaining the images of absorption and reduced scattering coefficients. The integrated intensity data has greater sensitivity to absorption coefficient variations than scattering coefficient. However, the sensitivity of intensity data to scattering coefficient is not zero. We considered an object with two inhomogeneities (one in absorption and the other in scattering coefficient). The standard iterative reconstruction techniques produced results, which were plagued by cross talk, i.e., the absorption coefficient reconstruction has a false positive corresponding to the location of scattering inhomogeneity, and vice-versa. We present a method to remove cross talk in the reconstruction, by generating a weight matrix and weighting the update vector during the iteration. The weight matrix is created by the following method: we first perform a simple backprojection of the difference between the experimental and corresponding homogeneous intensity data. The built up image has greater weightage towards absorption inhomogeneity than the scattering inhomogeneity and its appropriate inverse is weighted towards the scattering inhomogeneity. These two weight matrices are used as multiplication factors in the update vectors, normalized backprojected image of difference intensity for absorption inhomogeneity and the inverse of the above for the scattering inhomogeneity, during the image reconstruction procedure. We demonstrate through numerical simulations, that cross-talk is fully eliminated through this modified reconstruction procedure.
Resumo:
This article presents the optical absorption and emission properties of Pr3+ and Nd3+ doped two different mixed alkali chloroborate glass matrices of the type 70B(2)O(3)center dot xLiCl center dot(30 - x)NaCl and 70B(2)O(3)center dot xLiCl center dot(30 - x)KCl (x = 5, 10, 15.20 and 25). The variation of Judd-Ofelt parameters (Omega(2), Omega(4) and Omega(6)), total radiative transition probabilities (A(T)), radiative lifetimes (tau(R)) and emission cross-sections (sigma(p)) with the variation of alkali contents in the glass matrix have been discussed in detail. The changes in the peak wavelengths of the hypersensitive transition and intensity parameters with x are correlated to the structural changes in the host matrix. The estimated radiative lifetimes of certain excited states of Pr3+ and Nd3+ in these two glass matrices are reported. Peak stimulated emission cross-sections (sigma(p)) are reported for the observed emission transitions of Pr3+ and Nd3+ ions. Branching ratios (beta) of the observed emission transitions obtained from the Judd-Ofelt theory are compared with the values obtained from the emission spectra. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
The photoacoustic technique is used to determine the optical energy gap E0 of bulk SixTe100−x glasses in the glass-forming region 10 ≤ x ≤ 28. The thermal diffusivity α of these samples has also been measured. The variation of E0 and α with x is reported. It is found that E0 increases with x nearly linearly with a sharp decrease in the rate of increase beyond x = 20. The thermal diffusivity also increases with x up to x = 20 but decreases for compositions with higher values of x. The observed behaviour is explained on the basis of a chemical bond approach. It is accounted for in terms of the increase in the number of Te---Te bonds and formation of SiTe4 tetrahedra with an increase in the chalcogen content.
Resumo:
The study of non-invasive characterization of elastic properties of soft biological tissues has been a focus of active researches since recent years. Light is highly scattered by biological tissues and hence, sophisticated reconstruction algorithms are required to achieve good imaging depth and a reasonable resolution. Ultrasound (US), on the otherhand, is less scattered by soft tissues and it has been in use for imaging in biomedical ultrasound systems. Combination of the contrast sensitivity of light and good localization of ultrasound provides a challenging technique for characterization of thicker tissues deep inside the body non-invasively. The elasticity of the tissues is characterized by studying the response of tissues to mechanical excitation induced by an acoustic radiation force (remotely) using an optical laser. The US modulated optical signals which traverse the tissue are detected by using a CCD camera as detector array and the pixel map formed on the CCD is used to characterize the embedded inhomogeneities. The use of CCD camera improves the signal-noise-ratio (SNR) by averaging the signals from all of the CCD pixels.