882 resultados para laboratory tests


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Among the waste generated in the petrochemical industry water associated with oil production is the most important. It is considered one of the great challenges due to the presence of considered toxic chemicals present in this composition. The presence of these substances difficult to reuse the water associated with the enhanced recovery processes, so that prior to their reuse or disposal, treatment is necessary. This paper aimed to study the removal efficiency of chemical species: Ba2+, Ni2+, Cd2+, Cu2+, Cr3+, Sr2+ and Zn2+, present in the composition of the water associated with oil production by electrocoagulation. The evaluation of removal of these chemical species was performed by laboratory tests using electrochemical batch reactors and continuous flow. Initial tests were performed with electrocoagulation of synthetic wastewater in batch reactor using iron electrode. Results of removal of Zn2+ and Ni2+ were 78 % and 59 % respectively. While the percentage of removed Ba2+ was 19 % by 30 minutes of treatment and by applying current of 1.10 A. The tests were performed on effluent batch reactor applying the electrochemical technique with stainless steel electrodes 304, the objective was to remove part of the dispersed oil and also of organic compounds in the effluent. Under the experimental conditions used, the maximum result was obtained TOG was 60 % and TOC was approximately 50 % compared to the initial concentration. In the experiments carried out in continuous reactor, with effluent semisynthetic, have been used electrodes of iron and aluminum and the results were 100 % removal of Cd2+, Cu2+, Cr3+ and Zn2+ and 77 % of Sr2+. These percentages were only attainable through the use of the iron electrode. However, when the electrode was replaced by aluminum, there was a reduction in the percentage of removal to 65 %, using the same flow rate and current. Therefore according to the results obtained using the iron electrode was more effective in removing these metals and the conditions of lower current and lower flow rate was satisfactory, as observed in the experimental design adopted

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this approach is to describe the design and construction of a low-cost automated water sampler prototype. In recent years, there is an increasing need on the use of automated equipments for hydro climatic variables to be use in urban and rural environments. Such devices are always used to provide measured information which is of crucial importance on the development of water resources strategies at watershed scale. Actually, many research and water public institutions have been using these kinds of equipments. In most of the cases, automated equipments are expensive and need to be imported, generating a situation of technologic dependency. The prototype is based on an electronic system which controls a peristaltic pump functioning, five solenoid valves and an ultrasonic sensor connected to a datalloger. An interface with the user allows communication with a PC, when the equipment functioning parameters can be provided. The equipment has a hydraulic module composed by a 12V peristaltic pump connected to a distribution circuit composed by five solenoid valves, one of them being used to clean the circuit before each sampling procedure. Samples are collected by four 1.95 polyethylene bottles. The sampler body was made of acrylic material, with a cylindrical shape, and dimensions 0.72 m and 0.38 m height and diameter, respectively. The weight of the equipment without samples is approximately 15 kg, which infers to its portability. The prototype development total cost budget was approximately US$ 1,560.00. Laboratory tests aimed to evaluate the equipment performance and functioning demonstrated satisfactory results

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Analysis of experimental interlocking blocks of concrete with addition of residues of process the tires retreading production. With the population growth in recent years, industry in general has adjusted itself to resulting demand. the industry of tire retreading generates residues that have been discarded without any control. this adds to environmental pollution and promotes the proliferation of vectors harmful to health, aiming to find an application for this type of residues, this study presents experimental results to interlocking concrete block pavements, with addition of residues tires, interlocking blocks were built up and we determined, through laboratory tests, the need to set the mark that provide greater return regarding analyzed characteristics, there are four types of dosage of concrete with residues tires. We accomplished tests of compression strength, water absorption and resistance to impact. Through the preliminary results, we verified that are satisfactory, confirming the possibility of applying this type of interlocking block in environments with low demand, which would bring the economy of natural sources of aggregates, beyond ecological benefits through the reuse of residues from retreading of tires.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Enzymes have been widely used in biosynthesis/transformation of organic compounds in substitution the classic synthetic methods. This work is the first writing in literature of enzymatic synthesis for attainment the biossurfactants, the use glucose sucrose, ricinoleic acid e castor oil as substratum, and as biocatalyst, used immobilized lipase Thermomyces lanuginose, Rhizomucor miehei and the Candida antarctica lipase B; alkaline protease and neutral protease from Bacillus subtillis and yeast Saccharomyces cerevisiaeI. The analysis of HPLC (high performance liquid chromatography) showed that highest conversions were reached of used the alkaline protease from Bacillus subtillis. Laboratory tests, to evaluate the applicability, indicated that the produced biosurfactantes had good stability in presence of salts (NaCl) and temperature (55 e 25°C), they are effective in the reduction of the superficial tension and contac angle, but they have little foaming capacity, when compared with traditional detergents. These results suggest that the prepared surfactants have potential application as wetting agent and perforation fluid stabilizer

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The construction of wells is one of the most important activities of the oil industry. The drilling process is the set of activities and operations to design, program and perform the opening thereof. During this process, the cuttings are removed by the drilling fluid, or mud, and carted to the surface. This fluid is injected into the drill string and returns to the surface through the annular space between the well walls and the drill string. After the descent of the column casing, the annular space between the casing string and the walls of the borehole is filled with cement so as to secure the spine and prevent any migration of fluids between the various permeable zones traversed by the well behind of the coating. To ensure the good quality of the cementation scrubbers are used mattresses which are pumped ahead of the cement slurry so as to avoid contamination of the drilling fluid paste, or vice versa, and assist in the removal of plaster, formed by drilling fluid of the borehole walls, thus enabling a better cement bond to the well. Within this context, this work aims to evaluate the efficiency of mattresses scrubbers, the basis of ionic and nonionic surfactants, on the removal of nonaqueous drilling fluid, based on n-paraffin in oil wells, and the compatibility between the Mattress relations washer / drilling fluid bed scrubber / cement paste mattress washer / cement slurry / drilling fluid and the drilling fluid / cement slurry using laboratory tests rheology, thickening time and compressive strength. Also technique was performed X-ray diffraction (XRD) for a more detailed analysis of these mixtures with hydrated cement paste. In compatibility tests the conditions of temperature and pressure used in the same laboratory procedure simulating the conditions of oil wells, the well is considered the depth of 800 m. The results showed that the compositions of the mattress washer nonionic, KMS obtained a 100% efficient in removing the non-aqueous drilling fluid, and the best formulation showed good results with respect to compliance testing

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The development of products whose purpose is to promote blockages in high permeability zones as well as to control the hydrate or scale formation also needs some tests in porous media before using the product in the field, where attempts and unavoidable operational errors costs would able to derail any projects. The aim of this study was to analyze and compare the Botucatu and Berea sandstones properties, involving problems related to loss permeability. It was observed that even cores of Berea, without expansible clays in their composition had their permeability reduced, as soon as the salinity of brine reached a lower limit. As expected, the same happened with the Botucatu sandstone samples, however, in this case, the sensitivity to low salinity was more pronounced. In a second phase, the research was focused on the Botucatu Sandstone behavior front of dilute polymer solutions injection, checking the main relationships between the Rock / Fluid interactions, considering the Mobility Reduction, Resistance and Residual Resistance Factors, as well as adsorption/desorption processes of these polymers, and the polymer molecules average size and porous sandstone average size ratio. The results for both phases showed a real feasibility of using the Botucatu sandstone in laboratory tests whose objective is the displacement of fluids through porous media

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Os Autores descrevem um caso de paracoccidioidomicose subaguda progressiva, com quadro clínico sugestivo de síndrome de má absorção, em que o doente não se beneficiara apenas com o tratamento antifúngico convencional. Ao se introduzir como medida auxiliar a nutrição parenteral houve evidente melhora clínica e laboratorial. Desta maneira os Autores propõe o uso associado da nutrição parenteral no tratamento de doentes com esta forma clínica de paracoccidioidomicose.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Avaliar a microbiota intestinal de indivíduos que sofreram acidente ocupacional com materiais biológicos e receberam anti-retrovirais foi o objetivo deste estudo. O grupo de estudo constou de 23 indivíduos com idade entre 18-45 anos, sendo 13 doadores de sangue e 10 que sofreram acidente ocupacional. Foram avaliados a microbiota intestinal, antropometria e exames laboratoriais pré, pós e 30 dias após o término da medicação. Zidovudina mais lamivudina foi utilizada em 70% dos indivíduos associado ao nelfinavir, 20% ao efavirenz e 10% ao ritonavir. As alterações nutricionais e dietéticas-laboratoriais e de microbiota intestinal foram analisadas em três momentos. M1: até dois dias do início da profilaxia; M2: no último dia da profilaxia e M3: 30 dias após o término da profilaxia. Náuseas, vômitos e diarréia estiveram presentes em 50% no segundo momento do estudo. Sobrepeso em 70%, desnutrição e eutrofia em 10%, dos indivíduos, não se modificaram durante o estudo. Transaminases, triglicérides, LDL-colesterol se elevaram no segundo momento e normalizaram 30 dias após término da medicação. Houve redução significativa dos Lactobacillus, Bifidobacterium e Bacteróides nos três momentos. Uso de anti-retrovirais provocou impacto significativo na microbiota intestinal dos indivíduos, sem recuperação em 30 dias.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Esta pesquisa trata-se de um estudo de soroprevalência de anticorpos contra o sarampo, de uma determinada população infantil residente em Botucatu, SP, com o objetivo de avaliar o estado imunólogico, induzido quer por infecção natural, quer por meio de vacinação. Foram estudadas 101 crianças, sendo que todas receberam a vacina contra o sarampo. Os exames laboratoriais utilizados para avaliar a presença de anticorpos, nas amostras de sangue coletadas, foram o teste de Inibição de Hemaglutinação (IH) e o Ensaio imunoenzimático (ELISA). Os resultados do teste de IH, mostraram que 92,1% das amostras apresentavam anticorpos contra o sarampo. As amostras com títulos < que 1:4, quando estudadas pela IH, foram retestadas no mesmo laboratório por meio do ELISA, e somente duas mantiveram-se negativas para anticorpos contra o sarampo. Portanto, em 98% das amostras de soro das crianças estudadas os anticorpos contra o sarampo estavam presentes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

CONTEXTO: A síndrome HELLP é uma grave complicação da gestação caracterizada por hemólise, elevação das enzimas hepáticas e plaquetopenia. Algumas gestantes desenvolvem somente uma ou duas dessas características da síndrome HELLP. Esse quadro é denominado de síndrome HELLP parcial (SHP). OBJETIVO: O objetivo deste estudo foi avaliar as repercussões maternas e perinatais das mulheres que desenvolveram SHP e comparar os resultados com mulheres que tiveram hipertensão gestacional ou pré-eclâmpsia sem alterações dos exames laboratoriais para síndrome HELLP. TIPO DE ESTUDO: Observacional, retrospectivo e analítico. LOCAL: Maternidade do Hospital das Clínicas da Faculdade de Medicina de Botucatu, Universidade Estadual Paulista, Botucatu, São Paulo, Brasil. AMOSTRA: Foram selecionadas gestantes ou puérperas que tiveram elevação dos níveis pressóricos detectada pela primeira vez após a primeira metade da gestação com ou sem proteinúria entre janeiro/1990 a dezembro/1995. As mulheres foram divididas em dois grupos: Grupo SHP quando as mulheres com hipertensão arterial tinham pelo menos uma, mas não todas as alterações de exames que demonstravam hemólise, elevação das enzimas hepáticas ou plaquetopenia e Grupo Hipertensas pacientes com hipertensão sem alterações nos exames laboratoriais para síndrome HELLP. PRINCIPAIS VARIÁVEIS: Analisamos idade materna, raça, paridade, classificação da hipertensão, idade gestacional no diagnóstico da SHP, alterações nos exames laboratoriais para síndrome HELLP, tempo de permanência no hospital, complicações maternas, via de parto, incidência de prematuridade, restrição de crescimento intra-uterino, natimortos e neomortos. RESULTADOS: 318 mulheres foram selecionadas, das quais 41 (12,9%) tiveram SHP e 277 (87,1%) não desenvolveram alterações dos exames laboratoriais que compõem o diagnóstico da síndrome HELLP. A pré-eclâmpsia foi um tipo de hipertensão mais freqüente no grupo SHP que no grupo hipertensas. Não houve pacientes com hipertensão crônica isolada que desenvolveram SHP. A taxa de cesárea, eclâmpsia e de partos prematuros foi significativamente mais freqüente no grupo SHP que no grupo hipertensas. CONCLUSÃO: Observamos uma conduta agressiva nas pacientes com SHP, que resultou na interrupção imediata da gestação, com elevada taxa de cesárea e de recém-nascido pré-termo. Esta conduta deve ser revista para a redução desses índices.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A hipertensão arterial está entre as causas mais freqüentes de morte materna. Entre os tipos presentes na gravidez destacam-se as manifestações específicas, isto é, a pré-eclâmpsia e a hipertensão gestacional, definidas clinicamente por aumento dos níveis da pressão arterial após a 20ª semana de gestação, associado (pré-eclâmpsia) ou não (hipertensão gestacional) à proteinúria. Na fase inicial a doença é assintomática, porém, quando não tratada ou não se interrompe a gestação, sua evolução natural é desenvolver as formas graves, como a eclâmpsia e a síndrome HELLP. Eclâmpsia é definida pela manifestação de uma ou mais crises convulsivas tônico-clônicas generalizadas e/ou coma, em gestante com hipertensão gestacional ou pré-eclâmpsia, na ausência de doenças neurológicas. Pode ocorrer durante a gestação, durante o trabalho de parto e no puerpério imediato. É comumente precedida pelos sinais e sintomas de eclâmpsia iminente (distúrbios do sistema nervoso central, visuais e gástricos). A associação de hemólise, plaquetopenia e disfunção hepática já era relatada na literatura na década de cinqüenta. em 1982, Weinstein reuniu estas alterações sob o acrônimo de HELLP, significando hemólise (H), aumento de enzimas hepáticas (EL) e plaquetopenia (LP), e denominou-as de síndrome HELLP. A literatura diverge em relação aos valores dos parâmetros que definem a síndrome. Sibai et al. (1986) propuseram sistematização dos padrões laboratoriais e bioquímicos para o diagnóstico da mesma, que foi adotada pelo Ministério da Saúde do Brasil. As manifestações clínicas podem ser imprecisas, sendo comuns queixas como dor epigástrica, mal-estar geral, inapetência, náuseas e vômitos. O diagnóstico precoce é, eminentemente, laboratorial e deve ser pesquisado de maneira sistemática nas mulheres com pré-eclâmpsia grave/eclâmpsia e/ou dor no quadrante superior direito do abdome. Diferenciar a síndrome HELLP de outras ocorrências, com manifestações clínicas e/ou laboratoriais semelhantes, não é tarefa fácil. O diagnóstico diferencial é particularmente difícil para doenças como púrpura trombocitopênica trombótica, síndrome hemolítico-urêmica e fígado gorduroso agudo da gravidez, devido à insuficiente história clínica e à semelhança dos aspectos fisiopatológicos. O conhecimento da fisiopatologia da pré-eclâmpsia, o diagnóstico precoce e a atuação precisa no momento adequado nas situações complicadas pela eclâmpsia e/ou síndrome HELLP permitem melhorar o prognóstico materno e perinatal.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aims of the current study were to assess the prevalence of von Willebrand disease (vWD) in dogs from the region of Botucatu, São Paulo State, Brazil, and to evaluate laboratory tests to diagnose this disease. The study included 350 dogs of various ages, different breeds, and both sexes. Dogs included in the study had no historical or clinical evidence of abnormal bleeding. von Willebrand factor antigen (vWF:Ag), buccal mucosal bleeding time, activated partial thromboplastin time, and factor VIII activity were evaluated in their ability to diagnose vWD. The prevalence of vWD in dogs was 1.43% in the Botucatu region of Brazil. Determination of vWF:Ag was the best laboratory test to diagnose vWD.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)