983 resultados para inhalant anesthesia
Resumo:
INTRODUCTION: Intravenous sedation is the most commonly used method of sedation for the provision of adult dental care. However, disparity exists in pre-operative fasting times in use for patients throughout the United Kingdom.
AIMS: The aims of the study were to obtain information on the effects of existing extended pre-operative fasting regimens, to canvas patient opinions on the fasting process, and to record their positive and negative experiences associated with it.
METHODS: A prospective cross-sectional descriptive study using survey methodology was conducted of adult patients attending a dental hospital for operative treatment under intravenous sedation. Sixty-four questionnaires were distributed over a four-month period, beginning 2nd October 2007.
RESULTS: The surveyed patient pool consisted of 38 females and 14 males with a mean age of 32.4 years. The response rate achieved was 81.2%. Seventy-one per cent of patients indicated that normally they consumed something for breakfast, the most common items being tea and toast. Fifty-one per cent of patients indicated that they would wish to eat the same as normal prior to their appointment and 59% wished to drink as normal. Only 19% of respondents reported that they did not wish to eat anything, with 8% preferring not to drink anything at all. Seventy-nine per cent of the patients reported that they had experienced at least one adverse symptom after fasting and 42% had experienced two or more such symptoms. In general, those patients with more experience of sedation found fasting less unpleasant than those attending for the first time (P<0.05). In addition, one-quarter of all patients indicated that the fasting process had made them feel more nervous about their sedation appointment.
CONCLUSIONS: The extended fasting regimen prior to intravenous sedation appeared to affect patients' wellbeing, as the majority reported adverse symptoms.
Resumo:
Intravenous sedation is a widely used pharmacological method of patient management commonly used in dental surgery for the treatment of anxious patients. Variety exists in fasting regimes between different centres offering dental sedation, with some advocating starvation in line with general anaesthesia protocols and others not enforcing starvation at all. The currently available guidelines on fasting protocols are ambiguous and open to interpretation partly because they are based on expert opinion rather than evidence-based research. This article reviews the available evidence on the subject of pre-operative fasting and discusses current guidelines.
Resumo:
O presente trabalho teve como objetivo principal estudar o comportamento mecânico do disco intervertebral recorrendo a sensores em fibra ótica. Na expetativa de efetuar o melhor enquadramento do tema foi efetuada uma revisão exaustiva das várias configurações de sensores em fibra ótica que têm vindo a ser utilizadas em aplicações biomédicas e biomecânicas, nomeadamente para medição de temperatura, deformação, força e pressão. Nesse âmbito, procurou-se destacar as potencialidades dos sensores em fibra ótica e apresentá-los como uma tecnologia alternativa ou até de substituição das tecnologias associadas a sensores convencionais. Tendo em vista a aplicação de sensores em fibra ótica no estudo do comportamento do disco intervertebral efetuou-se também uma revisão exaustiva da coluna vertebral e, particularmente, do conceito de unidade funcional. A par de uma descrição anatómica e funcional centrada no disco intervertebral, vértebras adjacentes e ligamentos espinais foram ainda destacadas as suas propriedades mecânicas e descritos os procedimentos mais usuais no estudo dessas propriedades. A componente experimental do presente trabalho descreve um conjunto de experiências efetuadas com unidades funcionais cadavéricas utilizando sensores convencionais e sensores em fibra ótica com vista à medição da deformação do disco intervertebral sob cargas compressivas uniaxiais. Inclui ainda a medição in vivo da pressão intradiscal num disco lombar de uma ovelha sob efeito de anestesia. Para esse efeito utilizou-se um sensor comercial em fibra ótica e desenvolveu-se a respetiva unidade de interrogação. Finalmente apresenta-se os resultados da investigação em curso que tem como objetivo propor e desenvolver protótipos de sensores em fibra ótica para aplicações biomédicas e biomecânicas. Nesse sentido, são apresentadas duas soluções de sensores interferométricos para medição da pressão em fluídos corporais.
Resumo:
Este estudo teve como objectivo avaliar a eficácia de uma sessão de informação a propósito de uma intervenção cirúrgica com anestesia geral na redução da ansiedade em jovens com idades compreendidas entre os 6 e os 12 anos. A amostra foi constituída por 125 jovens, 62 do sexo masculino e 63 do sexo feminino. Foram constituídos dois grupos, em que ao grupo experimental foi administrado um programa de informação sobre procedimentos cirúrgicos com anestesia geral, utilizando técnicas de modelagem, e em que ao grupo de controlo apenas foi aplicada a sessão avaliativa. Os resultados obtidos permitiram concluir que a eficácia da sessão informativa a propósito de uma intervenção cirúrgica com anestesia geral na redução da ansiedade, nas crianças, foi comprovada. The aim of this study was to evaluate the efficacy of an information session about cirurgy, with general anesthesia induction, in reducing anxiety in children from 6 to 12 years undergoing cirurgy. Our sample was constituted by 125 children, 62 boys and 63 girls divided in two groups: the experimental group had an information session about chirurgical procedures with general anesthesia and had anxiety evaluated pre and post session, as the control group had only one anxiety evaluation. The results show that the session was effective on reducing pre-operatory anxiety in children.
Resumo:
BACKGROUND: Patient-controlled epidural analgesia with low concentrations of anesthetics is effective in reducing labor pain. The aim of this study was to assess and compare two ultra-low dose regimens of ropivacaine and sufentanil (0.1% ropivacaine plus 0.5 μg.ml-1 sufentanil vs. 0.06% ropivacaine plus 0.5 μg.ml-1 sufentanil) on the intervals between boluses and the duration of labor. MATERIAL AND METHODS: In this non-randomized prospective study, conducted between January and July 2010, two groups of parturients received patient-controlled epidural analgesia: Group I (n = 58; 1 mg.ml-1 ropivacaine + 0.5 μg.ml-1 sufentanil) and Group II (n = 57; 0.6 mg.ml-1 ropivacaine + 0.5 μg.ml-1 sufentanil). Rescue doses of ropivacaine at the concentration of the assigned group without sufentanil were administered as necessary. Pain, local anesthetic requirements, neuraxial blockade characteristics, labor and neonatal outcomes, and maternal satisfaction were recorded. RESULTS: The ropivacaine dose was greater in Group I (9.5 [7.7-12.7] mg.h-1 vs. 6.1 [5.1-9.8 mg.h-1], p < 0.001). A time increase between each bolus was observed in Group I (beta = 32.61 min, 95% CI [25.39; 39.82], p < 0.001), whereas a time decrease was observed in Group II (beta = -1.40 min, 95% CI [-2.44; -0.36], p = 0.009). The duration of the second stage of labor in Group I was significantly longer than that in Group II (78 min vs. 65 min, p < 0.001). CONCLUSIONS: Parturients receiving 0.06% ropivacaine exhibited less evidence of cumulative effects and exhibited faster second stage progression than those who received 0.1% ropivacaine.
Resumo:
INTRODUCTION: Ryanodine receptor gene (RYR1) mutations have been associated with central core disease (CCD), multiminicore/minicore/multicore disease (MmD), and susceptibility to malignant hyperthermia (MH). METHODS: Patients with muscle symptoms in adulthood, who had features compatible with CCD/MmD, underwent clinical, histological, and genetic (RYR1 and SEPN1 genes) evaluations. Published cases of CCD and MmD with adult onset were also reviewed. RESULTS: Eight patients fulfilled the criteria for further analysis. Five RYR1 mutations, 4 of them unreported, were detected in 3 patients. Compound heterozygosity was proven in 1 case. CONCLUSIONS: To our knowledge, this is the only report of adult onset associated with recessive RYR1 mutations and central core/multiminicores on muscle biopsy. Although adult patients with CCD, MmD, and minimally symptomatic MH with abnormal muscle biopsy findings usually have a mild clinical course, differential diagnosis and carrier screening is crucial for prevention of potentially life-threatening reactions to general anesthesia.
Resumo:
Dissertação de Mestrado Integrado em Medicina Veterinária
Resumo:
BACKGROUND: Hypotension, a common intra-operative incident, bears an important potential for morbidity. It is most often manageable and sometimes preventable, which renders its study important. Therefore, we aimed at examining hospital variations in the occurrence of intra-operative hypotension and its predictors. As secondary endpoints, we determined to what extent hypotension relates to the risk of post-operative incidents and death. METHODS: We used the Anaesthesia Databank Switzerland, built on routinely and prospectively collected data on all anaesthesias in 21 hospitals. The three outcomes were assessed using multi-level logistic regression models. RESULTS: Among 147,573 anaesthesias, hypotension ranged from 0.6% to 5.2% in participating hospitals, and from 0.3% up to 12% in different surgical specialties. Most (73.4%) were minor single events. Age, ASA status, combined general and regional anaesthesia techniques, duration of surgery and hospitalization were significantly associated with hypotension. Although significantly associated, the emergency status of the surgery had a weaker effect. Hospitals' odds ratios for hypotension varied between 0.12 and 2.50 (P < or = 0.001), even after adjusting for patient and anaesthesia factors, and for type of surgery. At least one post-operative incident occurred in 9.7% of the procedures, including 0.03% deaths. Intra-operative hypotension was associated with a higher risk of post-operative incidents and death. CONCLUSION: Wide variations remain in the occurrence of hypotension among hospitals after adjustment for risk factors. Although differential reporting from hospitals may exist, variations in anaesthesia techniques and blood pressure maintenance may also have contributed. Intra-operative hypotension is associated with morbidities and sometimes death, and constant vigilance must thus be advocated.
Resumo:
Cerebral metabolism is compartmentalized between neurons and glia. Although glial glycolysis is thought to largely sustain the energetic requirements of neurotransmission while oxidative metabolism takes place mainly in neurons, this hypothesis is matter of debate. The compartmentalization of cerebral metabolic fluxes can be determined by (13)C nuclear magnetic resonance (NMR) spectroscopy upon infusion of (13)C-enriched compounds, especially glucose. Rats under light α-chloralose anesthesia were infused with [1,6-(13)C]glucose and (13)C enrichment in the brain metabolites was measured by (13)C NMR spectroscopy with high sensitivity and spectral resolution at 14.1 T. This allowed determining (13)C enrichment curves of amino acid carbons with high reproducibility and to reliably estimate cerebral metabolic fluxes (mean error of 8%). We further found that TCA cycle intermediates are not required for flux determination in mathematical models of brain metabolism. Neuronal tricarboxylic acid cycle rate (V(TCA)) and neurotransmission rate (V(NT)) were 0.45 ± 0.01 and 0.11 ± 0.01 μmol/g/min, respectively. Glial V(TCA) was found to be 38 ± 3% of total cerebral oxidative metabolism, accounting for more than half of neuronal oxidative metabolism. Furthermore, glial anaplerotic pyruvate carboxylation rate (V(PC)) was 0.069 ± 0.004 μmol/g/min, i.e., 25 ± 1% of the glial TCA cycle rate. These results support a role of glial cells as active partners of neurons during synaptic transmission beyond glycolytic metabolism.
Resumo:
Difficult tracheal intubation assessment is an important research topic in anesthesia as failed intubations are important causes of mortality in anesthetic practice. The modified Mallampati score is widely used, alone or in conjunction with other criteria, to predict the difficulty of intubation. This work presents an automatic method to assess the modified Mallampati score from an image of a patient with the mouth wide open. For this purpose we propose an active appearance models (AAM) based method and use linear support vector machines (SVM) to select a subset of relevant features obtained using the AAM. This feature selection step proves to be essential as it improves drastically the performance of classification, which is obtained using SVM with RBF kernel and majority voting. We test our method on images of 100 patients undergoing elective surgery and achieve 97.9% accuracy in the leave-one-out crossvalidation test and provide a key element to an automatic difficult intubation assessment system.
Resumo:
PURPOSE: We report on the in vivo testing of a novel noninvasively adjustable glaucoma drainage device (AGDD), which features an adjustable outflow resistance, and assess the safety and efficiency of this implant. METHODS: Under general anesthesia, the AGDD was implanted on seven white New Zealand rabbits for a duration of 4 months under a scleral flap in a way analogous to the Ex-PRESS device and set in an operationally closed position. The IOP was measured on a regular basis on the operated and control eyes using a rebound tonometer. Once a month the AGDD was adjusted noninvasively from its fully closed to its fully open position and the resulting pressure drop was measured. The contralateral eye was not operated and served as control. After euthanization, the eyes were collected for histology evaluation. RESULTS: The mean preoperative IOP was 11.1 ± 2.4 mm Hg. The IOP was significantly lower for the operated eye (6.8 ± 2 mm Hg) compared to the nonoperated eye (13.1 ± 1.6 mm Hg) during the first 8 days after surgery. When opening the AGDD from its fully closed to fully open position, the IOP dropped significantly from 11.2 ± 2.9 to 4.8 ± 0.9 mm Hg (P < 0.05). CONCLUSIONS: Implanting the AGDD is a safe and uncomplicated surgical procedure. The fluidic resistance was noninvasively adjustable during the postoperative period with the AGDD between its fully closed and fully open positions.
Resumo:
En salle d’opération, les tâches de l’anesthésiste sont nombreuses. Alors que l’utilisation de nouveaux outils technologiques l’informe plus fidèlement sur ce qui se passe pour son patient, ces outils font que ses tâches deviennent plus exigeantes. En vue de diminuer cette charge de travail, nous avons considérer l’administration automatique d’agents anesthésiques en se servant de contrôle en boucle fermée. À cette fin, nous avons développé un système d’administration d’un agent anesthésique (le propofol) visant à maintenir à un niveau optimal la perte de conscience du patient pendant toute la durée d’une chirurgie. Le système comprend un ordinateur, un moniteur d’anesthésie et une pompe de perfusion. L’ordinateur est doté d’un algorithme de contrôle qui, à partir d’un indice (Bispectral IndexTM ou BIS) fournit par le moniteur d’anesthésie détermine le taux d’infusion de l’agent anesthésiant. Au départ, l’anesthésiste choisit une valeur cible pour la variable de contrôle BIS et l’algorithme, basé sur système expert, calcule les doses de perfusion de propofol de sorte que la valeur mesurée de BIS se rapproche le plus possible de la valeur cible établie. Comme interface-utilisateur pour un nouveau moniteur d’anesthésie, quatre sortes d’affichage ont été considérés: purement numérique, purement graphique, un mélange entre graphique et numérique et un affichage graphique intégré (soit bidimensionnel). À partir de 20 scenarios différents où des paramètres normaux et anormaux en anesthésie étaient présentés à des anesthésistes et des résidents, l’étude des temps de réaction, de l’exactitude des réponses et de la convivialité (évaluée par le NASA-TLX) a montré qu’un affichage qui combine des éléments graphiques et numériques était le meilleur choix comme interface du système. Une étude clinique a été réalisée pour comparer le comportement du système d’administration de propofol en boucle fermée comparativement à une anesthésie contrôlée de façon manuelle et conventionnelle où le BIS était aussi utilisé. Suite à l’approbation du comité d’éthique et le consentement de personnes ayant à subir des chirurgies générales et orthopédiques, 40 patients ont été distribués également et aléatoirement soit dans le Groupe contrôle, soit dans le Groupe boucle fermée. Après l’induction manuelle de propofol (1.5 mg/kg), le contrôle en boucle fermée a été déclenché pour maintenir l’anesthésie à une cible de BIS fixée à 45. Dans l’autre groupe, le propofol a été administré à l’aide d’une pompe de perfusion et l’anesthésiste avait aussi à garder manuellement l’indice BIS le plus proche possible de 45. En fonction du BIS mesuré, la performance du contrôle exercé a été définie comme excellente pendant les moments où la valeur du BIS mesurée se situait à ±10% de la valeur cible, bonne si comprise de ±10% à ±20%, faible si comprise de ±20% à ±30% ou inadéquate lorsque >±30%. Dans le Groupe boucle fermée, le système a montré un contrôle excellent durant 55% du temps total de l’intervention, un bon contrôle durant 29% du temps et faible que pendant 9% du temps. Le temps depuis l’arrêt de la perfusion jusqu’à l’extubation est de 9 ± 3.7 min. Dans le Groupe contrôle, un contrôle excellent, bon, et faible a été enregistré durant 33%, 33% et 15% du temps respectivement et les doses ont été changées manuellement par l’anesthésiste en moyenne 9.5±4 fois par h. L’extubation a été accomplie après 11.9 ± 3.3 min de l’arrêt de la perfusion. Dans le Groupe boucle fermée, un contrôle excellent a été obtenu plus longtemps au cours des interventions (P<0.0001) et un contrôle inadéquat moins longtemps (P=0.001) que dans le Groupe contrôle. Le système en boucle fermée d’administration de propofol permet donc de maintenir plus facilement l’anesthésie au voisinage d’une cible choisie que l’administration manuelle.
Resumo:
L'eugénol (2-methoxy-4-(2-propenyl) phénol), produit dérivé du clou de girofle (Eugenia aromatica), fut tout d’abord utilisé en application topique à des fins d’analgésie dentaire. Il produit également une anesthésie chirurgicale lorsque administré en immersion chez les poissons. L’eugénol agit sur les récepteurs vanilloïdes, sensibles à la chaleur, aux protons et à certaines molécules lipidiques. Ces récepteurs jouent un rôle important dans le mécanisme de l’inflammation et de l’hyperalgésie. L’eugénol pourrait également produire ses effets par antagonisme des récepteurs glutamaergiques (NMDA) et par son activation des récepteurs GABAergiques. Considérant que l’eugénol produit des effets analgésiques et anesthésiques, des études de pharmacocinétique et de pharmacodynamie furent réalisées chez la grenouille (Xenopus laevis), le poisson (Oncorhynchus mykiss) et le rat (Rattus norvegicus). Les résultats démontrent que l’eugénol administré par immersion à une dose efficace permet d’atteindre une anesthésie chirurgicale chez les grenouilles (350 mg/L) et les poissons (75 mg/L). Suite à des analyses plasmatiques par LC/MS/MS, la pharmacocinétique des grenouilles, des poissons et des rats montre que la drogue est éliminée et qu’il pourrait y avoir une recirculation entérohépathique plus importante chez la grenouille et le rat. La longue demi-vie chez le rat suggère aussi une accumulation dans les tissus après des administrations répétées. Suite à l’administration intraveineuse d’une dose de 20 mg/kg chez le rat, l’eugénol induit une anesthésie chirurgicale pour une très courte période de temps variant autour de 167 s. Les résultats de sensibilité thermique confirment l’efficacité de l’eugénol pour réduire l’hyperalgésie induite chez des rats neuropathiques. L’effet pharmacologique de l’eugénol a démontré une augmentation progressive constante de l’analgésie sur une période de cinq jours de traitements journaliers. En conclusion, l’eugénol possède des propriétés analgésiques et anesthésiques chez la grenouille africaine à griffes (Xenopus laevis), le poisson (Oncorhynchus mykiss) et le rat (Rattus norvegicus).
Resumo:
L’endothéline-1 (ET-1) est un puissant agent vasoconstricteur dont la production est dérégulée dans plusieurs maladies inflammatoires où l’expression des cyclooxygénases-1/2 (COX-1/2) est augmentée. Puisqu’il est connu que la voie p38 MAPK est impliquée dans la régulation de l’ET-1 au niveau de l’ARNm, nous avons étudié le rôle de l’un de ses substrats, la kinase MK2 dans la régulation post-transcriptionnelle de l’ET-1 et des COX. Pour ce faire, nous avons utilisé des souris MK2-déficientes (MK2-/-) ainsi que des contrôles (MK2+/+) issus de la même portée. Des paramètres de la fonction cardiaque ont été mesurés sous anesthésie à l’aide d’un cathéter Millar et la réactivité vasculaire de l’artère fémorale a été mesurée par myographe. L’expression de ET-1, COX-1 et COX-2 a été quantifiée dans la cellule endothéliale aortique (CE) par qPCR. En réponse à l’ET-1 (100 nM), l’expression de la préproET-1 dans les CE augmente en fonction du temps (p<0.05) : cette variation est accentuée chez les souris MK2-/-. Bien que la pression artérielle soit similaire entre les souris MK2+/+ et MK2-/-, l’inhibition de COX (indométacine, 1 μM) augmente (p<0.05) la contraction à l’ET-1 des vaisseaux isolés provenant de souris MK2+/+ mais pas des MK2-/-. Ces données suggèrent un rôle de MK2 dans la réponse vasculaire à l’ET-1 et possiblement dans la signalisation post-récepteur de l’ET-1 en général.