757 resultados para holographic interferometry
Resumo:
We present an analytical method that yields the real and imaginary parts of the refractive index (RI) from low-coherence interferometry measurements, leading to the separation of the scattering and absorption coefficients of turbid samples. The imaginary RI is measured using time-frequency analysis, with the real part obtained by analyzing the nonlinear phase induced by a sample. A derivation relating the real part of the RI to the nonlinear phase term of the signal is presented, along with measurements from scattering and nonscattering samples that exhibit absorption due to hemoglobin.
Resumo:
We present measurements of morphological features in a thick turbid sample using light-scattering spectroscopy (LSS) and Fourier-domain low-coherence interferometry (fLCI) by processing with the dual-window (DW) method. A parallel frequency domain optical coherence tomography (OCT) system with a white-light source is used to image a two-layer phantom containing polystyrene beads of diameters 4.00 and 6.98 mum on the top and bottom layers, respectively. The DW method decomposes each OCT A-scan into a time-frequency distribution with simultaneously high spectral and spatial resolution. The spectral information from localized regions in the sample is used to determine scatterer structure. The results show that the two scatterer populations can be differentiated using LSS and fLCI.
Resumo:
We demonstrate a simple approach for inline holographic coherent anti-Stokes Raman scattering (CARS) microscopy, in which a layer of uniform nonlinear medium is placed in front of a specimen to be imaged. The reference wave created by four-wave mixing in the nonlinear medium can interfere with the CARS signal generated in the specimen to result in an inline hologram. We experimentally and theoretically investigate the inline CARS holography and show that it has chemical selectivity and can allow for three-dimensional imaging.
Resumo:
We show that the statistical properties of a Coulomb crystal can be measured by means of a standard interferometric procedure performed on the spin of one ion in the chain. The ion spin, constituted by two internal levels of the ion, couples to the crystal modes via spatial displacement induced by photon absorption. The loss of contrast in the interferometric signal allows one to measure the autocorrelation function of the crystal observables. Close to the critical point, where the chain undergoes a second-order phase transition to a zigzag structure, the signal gives the behavior of the correlation function at the critical point.
Resumo:
Interferometry has been used to investigate the spatio-temporal evolution of the electron number density in the initial stages of expansion following 248 nm ablation of a titanium target. Three-dimensional electron number densities are obtained from an interferogram of the plasma plume using the Abel inversion technique.
Resumo:
The safety of our food is an essential requirement of society. One well-recognised threat is that of chemical contamination of our food, where low-molecular-weight compounds such as biotoxins, drug residues and pesticides are present. Low-cost, rapid screening procedures are sought to discriminate the suspect samples from the population, thus selecting only these to be forwarded for confirmatory analysis. Many biosensor assays have been developed as screening tools in food contaminant analysis, but these tend to be electrochemical, fluorescence or surface plasmon resonance based. An alternative approach is the use of biolayer interferometry, which has become established in drug discovery and life science studies but is only now emerging as a potential tool in the analysis of food contaminants. A biolayer interferometry biosensor was assessed using domoic acid as a model compound. Instrument repeatability was tested by simultaneously producing six calibration curves showing replicate repeatability (n = 2) ranging from 0.1 to 6.5 % CV with individual concentration measurements (n = 12) ranging from 4.3 to 9.3 % CV, giving a calibration curve midpoint of 7.5 ng/ml (2.3 % CV (n = 6)). Reproducibility was assessed by producing three calibration curves on different days, giving a midpoint of 7.5 ng/ml (3.4 %CV (n = 3)). It was further shown, using assay development techniques, that the calibration curve midpoint could be adjusted from 10.4 to 1.9 ng/ml by varying assay parameters before the simultaneous construction of three calibration curves in matrix and buffer. Sensitivity of the assay compared favourably with previously published biosensor data for domoic acid. © 2013 Springer-Verlag Berlin Heidelberg.
Resumo:
Out-of-equilibrium statistical mechanics is attracting considerable interest due to the recent advances in the control and manipulations of systems at the quantum level. Recently, an interferometric scheme for the detection of the characteristic function of the work distribution following a time-dependent process has been proposed [L. Mazzola et al., Phys. Rev. Lett. 110 (2013) 230602]. There, it was demonstrated that the work statistics of a quantum system undergoing a process can be reconstructed by effectively mapping the characteristic function of work on the state of an ancillary qubit. Here, we expand that work in two important directions. We first apply the protocol to an interesting specific physical example consisting of a superconducting qubit dispersively coupled to the field of a microwave resonator, thus enlarging the class of situations for which our scheme would be key in the task highlighted above. We then account for the interaction of the system with an additional one (which might embody an environment), and generalize the protocol accordingly.
Resumo:
An exact multiple-scattering formalism is used to simulate a wave multiply scattered from a cluster, and this is used to provide a direct quantitative analysis of the influence of multiple scattering on holographic imaging. Although multiple scattering may help in identifying atomic positions in real space, we show that it does cause a loss of resolution. We also show that a filter function can considerably reduce the multiple-scattering contribution to holographic images.
Resumo:
BARTON 1 has suggested that photoelectron interference patterns may be used directly as holograms to obtain atomic-resolution images of surface structures. Bulk structures have been obtained previously by this means from experimental patterns of high-energy Kikuchi(quasi-elastically scattered) and Auger electrons 2,3. Here we test the feasibility of this technique for determination of surface structures using Auger intensity patterns obtained 4,5 from iodine chemisorbed on a pseudomorphic silver monolayer on Pt{111}. By direct numerical holographic inversion, we obtain three-dimensional images which show that iodine adatoms are located in hollows of 3-fold symmetry on the surface. The images yield the site symmetry with good atomic resolution in the surface plane, but suffer from poor resolution along the Ag-I axis. We anticipate that data with better angular resolution obtained at low temperatures would improve the spatial resolution of such images.
Resumo:
We break down photoelectron diffraction intensities into four terms in analogy to optical holography and discuss the effect of each term on reconstructed images. The second term involving products of scattered waves SIGMA-SIGMA-O(i)O(j)*, is in this case not structure-less. Theoretical analysis and simulations demonstrate that this term may lead to spurious features in real space images in holographic transforms of medium energy electron diffraction patterns. If it is small enough the problem may be overcome by an iterative correction process.