955 resultados para gold standard


Relevância:

60.00% 60.00%

Publicador:

Resumo:

In order to evaluate the Organon Teknika MB/BacT system used for testing indirect susceptibility to the alternative drugs ofloxacin (OFLO), amikacin (AMI), and rifabutin (RIF), and to the usual drugs of standard treatment regimes such as rifampin (RMP), isoniazid (INH), pyrazinamide (PZA), streptomycin (SM), ethambutol (EMB), and ethionamide (ETH), cultures of clinical specimens from 117 patients with pulmonary tuberculosis under multidrug-resistant investigation, admitted sequentially for examination from 2001 to 2002, were studied. Fifty of the Mycobacterium tuberculosis cultures were inoculated into the gold-standard BACTEC 460 TB (Becton Dickinson) for studying resistance to AMI, RIF, and OFLO, and the remaining 67 were inoculated into Lowenstein Jensen (LJ) medium (the gold standard currently used in Brazil) for studying resistance to RMP, INH, PZA, SM, EMB, and ETH. We observed 100% sensitivity for AMI (80.8-100), RIF (80.8-100), and OFLO (78.1-100); and 100% specificity for AMI (85.4-100), RIF (85.4-100), and OFLO (86.7-100) compared to the BACTEC system. Comparing the results obtained in LJ we observed 100% sensitivity for RMP (80-100), followed by INH - 95% (81.8-99.1), EMB - 94.7% (71.9-99.7), and 100% specificity for all drugs tested except for PZA - 98.3 (89.5-99.9) at 95% confidence interval. The results showed a high level of accuracy and demonstrated that the fully automated, non-radiometric MB/BacT system is indicated for routine use in susceptibility testing in public health laboratories.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Four methods (chromogenic, acidimetric, inhibition, and iodometric) for demonstration of the beta-lactamase production by 70 isolates of Neisseria gonorrhoeae, were evaluated in Cuba. There was 100% correlation between all beta-lactamase methods and the standardized penicillin dilution susceptibility test for penicillinase-non-producing N. gonorrhoeae. For penicillinase-producing N. gonorrhoeae strains, there was a perfect correlation between the chromogenic method and penicillin susceptibility testing, but one and two strains failed to give a positive result for beta-lactamase with the inhibition/acidimetric and the iodometric methods, respectively. There was a high concordance between the chromogenic method, considered as gold standard and the rest of penicillinase tests evaluated: Kappa Index (KI) = 0.98 for inhibition/acidimetric methods and KI = 0.97 for the iodometric method. The four methods evaluated were accurate, reproducible, easily readable, economical, and ease to use for screening primary isolates of N. gonorrhoeae in Cuba. We recommended the use of the inhibition method, when testing the penicillinase activity in gonococcal isolates in provincial and municipal reference laboratories.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We present and validate BlastR, a method for efficiently and accurately searching non-coding RNAs. Our approach relies on the comparison of di-nucleotides using BlosumR, a new log-odd substitution matrix. In order to use BlosumR for comparison, we recoded RNA sequences into protein-like sequences. We then showed that BlosumR can be used along with the BlastP algorithm in order to search non-coding RNA sequences. Using Rfam as a gold standard, we benchmarked this approach and show BlastR to be more sensitive than BlastN. We also show that BlastR is both faster and more sensitive than BlastP used with a single nucleotide log-odd substitution matrix. BlastR, when used in combination with WU-BlastP, is about 5% more accurate than WU-BlastN and about 50 times slower. The approach shown here is equally effective when combined with the NCBI-Blast package. The software is an open source freeware available from www.tcoffee.org/blastr.html.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Global left ventricular (LV) systolic dysfunction is the strongest predictor of morbidity and mortality in Chagas disease. Echocardiography is considered the gold standard for the detection of LV dysfunction, but not always available in endemic areas where chagasic cardiomyopathy is most common. Brain natriuretic peptide (BNP) is a neurohormone that has been recently described as a simple and inexpensive diagnostic and prognostic marker for patients with congestive heart failure. Chagasic patients (n = 63) and non-infected healthy individuals (n = 18) were recruited prospectively and underwent complete clinical examination, echocardiography and 24-h Holter monitoring. BNP was measured from thawed plasma samples using the Triage BNP test. We observed high levels of BNP in association with depression of LV ejection fraction, with increase of LV end-diastolic diameter and with LV premature complexes. An elevated concentration of BNP, defined as a concentration of 60 pg/ml or more, had a sensitivity of 91.7%, specificity of 82.8%, positive predictive value of 52.4%, and negative predictive value of 98% for detecting LV dysfunction (LV ejection fraction < 40%).BNP measurement using a simple, relatively inexpensive and rapid test has a promising role in identifying LV dysfunction associated with chagasic cardiomyopathy. Equally important, patients with Trypanosoma cruzi infection who have low levels of BNP level in plasma have a very low likelihood of severe cardiac involvement, and echocardiography is probably not necessary.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

After more than 40 years of clinical use, levodopa (LD) remains the gold standard of symptomatic efficacy in the drug treatment of Parkinson's disease (PD). Compared with other available dopaminergic therapies, dopamine replacement with LD is associated with the greatest improvement in motor function. Long-term treatment with LD is, however, often complicated by the development of various types of motor response oscillations over the day, as well as drug-induced dyskinesias. Motor fluctuations can be improved by the addition of drugs such as entacapone or monoamine oxidase inhibitors, which extend the half-life of levodopa or dopamine, respectively. However, dyskinesia control still represents a major challenge. As a result, many neurologists have become cautious when prescribing therapy with LD. This review summarizes the available evidence regarding the use of LD to treat PD and will also address the issue of LD delivery as a critical factor for the drug's propensity to induce motor complications.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coagulase-negative staphylococci (CoNS) are an important cause of nosocomial bacteremia, specially in patients with indwelling devices or those submitted to invasive medical procedures. The identification of species and the accurate and rapid detection of methicillin resistance are directly dependent on the quality of the identification and susceptibility tests used, either manual or automated. The objective of this study was to evaluate the accuracy of two automated systems MicroScan and Vitek - in the identification of CoNS species and determination of susceptibility to methicillin, considering as gold standard the biochemical tests and the characterization of the mecA gene by polymerase chain reaction, respectively. MicroScan presented better results in the identification of CoNS species (accuracy of 96.8 vs 78.8%, respectively); isolates from the following species had no precise identification: Staphylococcus haemolyticus, S. simulans, and S. capitis. Both systems were similar in the characterization of methicillin resistance. The higher discrepancies for gene mec detection were observed among species other than S. epidermidis (S. hominis, S. saprophyticus, S. sciuri, S. haemolyticus, S. warneri, S. cohnii), and those with borderline MICs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A study was carried out to compare the performance of a commercial method (MGIT) and four inexpensive drug susceptibility methods: nitrate reductase assay (NRA), microscopic observation drug susceptibility (MODS) assay, MTT test, and broth microdilution method (BMM). A total of 64 clinical isolates of Mycobacterium tuberculosis were studied. The Lowenstein-Jensen proportion method (PM) was used as gold standard. MGIT, NRA, MODS, and MTT results were available on an average of less than 10 days, whereas BMM results could be reported in about 20 days. Most of the evaluated tests showed excellent performance for isoniazid and rifampicin, with sensitivity and specificity values > 90%. With most of the assays, sensitivity for ethambutol was low (62-87%) whereas for streptomycin, sensitivity values ranged from 84 to 100%; NRA-discrepancies were associated with cultures with a low proportion of EMB-resistant organisms while most discrepancies with quantitative tests (MMT and BMM) were seen with isolates whose minimal inhibitory concentrations fell close the cutoff. MGIT is reliable but still expensive. NRA is the most inexpensive and easiest method to perform without changing the organization of the routine PM laboratory performance. While MODS, MTT, and BMM, have the disadvantage from the point of view of biosafety, they offer the possibility of detecting partial resistant strains. This study shows a very good level of agreement of the four low-cost methods compared to the PM for rapid detection of isoniazid, rifampicin and streptomycin resistance (Kappa values > 0.8); more standardization is needed for ethambutol.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The increasing number of pertussis cases reported on the last twenty years and the existence of new acellular vaccines reinforce the need of research for experimental models to assure the quality of available pertussis vaccines. In this study, allotments of whole-cell and acellular pertussis vaccines were tested through the Intranasal Challenge Model (INM) using conventional NIH mice. The results have been compared to those achieved by the "Gold standard" Intracerebral Challenge Model (ICM). In contrast to ICM, INM results did not show intralaboratorial variations. Statistical analysis by Anova and Ancova tests revealed that the INM presented reproducibility and allowed identification and separation of different products, including three-component and four-component accellular pertussis vaccines. INM revealed differences between pertussis vaccines. INM provides lower distress to the mice allowing the reduction of mice number including the possibility of using conventional mice (less expensive) under non-aseptic environment. Thus, INM may be used as an alternative method of verifying the consistence of allotment production, including acellular pertussis vaccines.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background. The use of hospital discharge administrative data (HDAD) has been recommended for automating, improving, even substituting, population-based cancer registries. The frequency of false positive and false negative cases recommends local validation. Methods. The aim of this study was to detect newly diagnosed, false positive and false negative cases of cancer from hospital discharge claims, using four Spanish population-based cancer registries as the gold standard. Prostate cancer was used as a case study. Results. A total of 2286 incident cases of prostate cancer registered in 2000 were used for validation. In the most sensitive algorithm (that using five diagnostic codes), estimates for Sensitivity ranged from 14.5% (CI95% 10.3-19.6) to 45.7% (CI95% 41.4-50.1). In the most predictive algorithm (that using five diagnostic and five surgical codes) Positive Predictive Value estimates ranged from 55.9% (CI95% 42.4-68.8) to 74.3% (CI95% 67.0-80.6). The most frequent reason for false positive cases was the number of prevalent cases inadequately considered as newly diagnosed cancers, ranging from 61.1% to 82.3% of false positive cases. The most frequent reason for false negative cases was related to the number of cases not attended in hospital settings. In this case, figures ranged from 34.4% to 69.7% of false negative cases, in the most predictive algorithm. Conclusions. HDAD might be a helpful tool for cancer registries to reach their goals. The findings suggest that, for automating cancer registries, algorithms combining diagnoses and procedures are the best option. However, for cancer surveillance purposes, in those cancers like prostate cancer in which care is not only hospital-based, combining inpatient and outpatient information will be required.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In Nigeria, schistosomiasis, caused predominantly by the species Schistosoma haematobium, is highly endemic in resource-poor communities. We performed a school-based survey in two rural communities in Osun State (Southwestern Nigeria) and assessed macrohaematuria, microhaematuria and proteinuria as indirect indicators for the presence of disease. Urine samples were inspected macroscopically for haematuria and screened for microhaematuria and proteinuria using urine reagent strips. The microscopic examination of schistosome eggs was used as the gold standard for diagnosis. In total, 447 schoolchildren were included in this study and had a 51% prevalence of urinary schistosomiasis. The sensitivity of microhaematuria (68%) and proteinuria (53%) for infection with S. haematobium was relatively low. In patients with a heavy infection (>500 eggs/10 mL), the sensitivity of microhaematuria was high (95%). When the presence of macrohaematuria and the concomitant presence of microhaematuria and proteinuria were combined, it revealed a sensitivity of 63%, a specificity of 93% and a positive predictive value of 91%. Macrohaematuria also showed high specificity (96%) and a positive predictive value of 92%, while sensitivity was < 50%. These data show that combining urine reagent strip tests (presence of proteinuria and microhaematuria) and information on macrohaematuria increased the accuracy of the rapid diagnosis of urinary schistosomiasis in an endemic rural West African setting. This simple approach can be used to increase the quality of monitoring of schistosomiasis in schoolchildren.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Necrotising pneumonia in young, previously healthy patients due to Panton–Valentine leucocidin (PVL) producing Staphylococcus aureus has been increasingly recognised. PVL pneumonia is often associated with influenza co-infection and high mortality. This case report describes the successful management of the first documented paediatric case of a previous healthy adolescent who developed necrotising pneumonia due to community-acquired methicillin-resistant (CA-MRSA) clone USA300 with pandemic influenza A (H1N1) co-infection, and highlights the importance of early recognition and initiation of appropriate therapy for this potentially fatal co-infection. PCR remains the gold standard to diagnose pandemic H1N1 since it may not be detected by rapid antigen tests. Bacterial necrotising pneumonia should be suspected in those presenting with worsening flu-like symptoms and clinical and/or radiological evidence of PVL infection (multifocal infiltrates, effusion and cavitation). These patients may benefit from the administration of toxin neutralising agents. In light of the current H1N1 pandemic, healthcare professionals will be increasingly confronted with this clinical scenario.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The progression-free survival rate at 6months (PFS-6) has long been considered the best end-point for assessing the efficacy of new agents in phase II trials in patients with recurrent glioblastoma. However, due to the introduction of antiangiogenic agents in this setting, and their intrinsic propensity to alter neuroradiological disease assessment by producing pseudoregression, any end-point based on neuroradiological modifications should be reconsidered. Further, statistically significant effects on progression-free survival (PFS) only should not automatically be considered reliable evidence of meaningful clinical benefit. In this context, because of its direct and unquestionable clinical relevance, overall survival (OS) represents the gold standard end-point for measuring clinical efficacy, despite the disadvantage that it is influenced by subsequent therapies and usually takes longer time to be evaluated. Therefore, while awaiting novel imaging criteria for response evaluation and/or new imaging tools to distinguish between 'true' and 'pseudo'-responses to antiangiogenic agents, the measurement of OS or OS rates should be considered primary end-points, also in phase II trials with these agents.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND To assess and compare the effectiveness and costs of Phototest, Mini Mental State Examination (MMSE), and Memory Impairment Screen (MIS) to screen for dementia (DEM) and cognitive impairment (CI). METHODS A phase III study was conducted over one year in consecutive patients with suspicion of CI or DEM at four Primary Care (PC) centers. After undergoing all screening tests at the PC center, participants were extensively evaluated by researchers blinded to screening test results in a Cognitive-Behavioral Neurology Unit (CBNU). The gold standard diagnosis was established by consensus of expert neurologists. Effectiveness was assessed by the proportion of correct diagnoses (diagnostic accuracy [DA]) and by the kappa index of concordance between test results and gold standard diagnoses. Costs were based on public prices and hospital accounts. RESULTS The study included 140 subjects (48 with DEM, 37 with CI without DEM, and 55 without CI). The MIS could not be applied to 23 illiterate subjects (16.4%). For DEM, the maximum effectiveness of the MMSE was obtained with different cutoff points as a function of educational level [k = 0.31 (95% Confidence interval [95%CI], 0.19-0.43), DA = 0.60 (95%CI, 0.52-0.68)], and that of the MIS with a cutoff of 3/4 [k = 0.63 (95%CI, 0.48-0.78), DA = 0.83 (95%CI, 0.80-0.92)]. Effectiveness of the Phototest [k = 0.71 (95%CI, 0.59-0.83), DA = 0.87 (95%CI, 0.80-0.92)] was similar to that of the MIS and higher than that of the MMSE. Costs were higher with MMSE (275.9 ± 193.3€ [mean ± sd euros]) than with Phototest (208.2 ± 196.8€) or MIS (201.3 ± 193.4€), whose costs did not significantly differ. For CI, the effectiveness did not significantly differ between MIS [k = 0.59 (95%CI, 0.45-0.74), DA = 0.79 (95%CI, 0.64-0.97)] and Phototest [k = 0.58 (95%CI, 0.45-0.74), DA = 0.78 (95%CI, 0.64-0.95)] and was lowest for the MMSE [k = 0.27 (95%CI, 0.09-0.45), DA = 0.69 (95%CI, 0.56-0.84)]. Costs were higher for MMSE (393.4 ± 121.8€) than for Phototest (287.0 ± 197.4€) or MIS (300.1 ± 165.6€), whose costs did not significantly differ. CONCLUSION MMSE is not an effective instrument in our setting. For both DEM and CI, the Phototest and MIS are more effective and less costly, with no difference between them. However, MIS could not be applied to the appreciable percentage of our population who were illiterate.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND Illiteracy, a universal problem, limits the utilization of the most widely used short cognitive tests. Our objective was to assess and compare the effectiveness and cost for cognitive impairment (CI) and dementia (DEM) screening of three short cognitive tests applicable to illiterates. METHODS Phase III diagnostic test evaluation study was performed during one year in four Primary Care centers, prospectively including individuals with suspicion of CI or DEM. All underwent the Eurotest, Memory Alteration Test (M@T), and Phototest, applied in a balanced manner. Clinical, functional, and cognitive studies were independently performed in a blinded fashion in a Cognitive Behavioral Neurology Unit, and the gold standard diagnosis was established by consensus of expert neurologists on the basis of these results. Effectiveness of tests was assessed as the proportion of correct diagnoses (diagnostic accuracy [DA]) and the kappa index of concordance (k) with respect to gold standard diagnoses. Costs were based on public prices at the time and hospital accounts. RESULTS The study included 139 individuals: 47 with DEM, 36 with CI, and 56 without CI. No significant differences in effectiveness were found among the tests. For DEM screening: Eurotest (k = 0.71 [0.59-0.83], DA = 0.87 [0.80-0.92]), M@T (k = 0.72 [0.60-0.84], DA = 0.87 [0.80-0.92]), Phototest (k = 0.70 [0.57-0.82], DA = 0.86 [0.79-0.91]). For CI screening: Eurotest (k = 0.67 [0.55-0.79]; DA = 0.83 [0.76-0.89]), M@T (k = 0.52 [0.37-0.67]; DA = 0.80 [0.72-0.86]), Phototest (k = 0.59 [0.46-0.72]; DA = 0.79 [0.71-0.86]). There were no differences in the cost of DEM screening, but the cost of CI screening was significantly higher with M@T (330.7 ± 177.1 €, mean ± sd) than with Eurotest (294.1 ± 195.0 €) or Phototest (296.0 ± 196. 5 €). Application time was shorter with Phototest (2.8 ± 0.8 min) than with Eurotest (7.1 ± 1.8 min) or M@T (6.8 ± 2.2 min). CONCLUSIONS Eurotest, M@T, and Phototest are equally effective. Eurotest and Phototest are both less expensive options but Phototest is the most efficient, requiring the shortest application time.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The general practice of altitude training is widely accepted as a means to enhance sport performance despite a lack of rigorous scientific studies. For example, the scientific gold-standard design of a double-blind, placebo-controlled, cross-over trial has never been conducted on altitude training. Given that few studies have utilised appropriate controls, there should be more scepticism concerning the effects of altitude training methodologies. In this brief review we aim to point out weaknesses in theories and methodologies of the various altitude training paradigms and to highlight the few well-designed studies to give athletes, coaches and sports medicine professionals the current scientific state of knowledge on common forms of altitude training. Another aim is to encourage investigators to design well-controlled studies that will enhance our understanding of the mechanisms and potential benefits of altitude training.