925 resultados para glass transition


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Crystallization kinetics of MSI and MSII stages in Metglas 2826A has been investigated by quantitative transmission electron microscopy. The volume fraction of crystallization against time curve has been found to show a plateau in the lower temperature region of annealing. It has been found that the glass transition temperature, T g, has no effect on the sequence reversal of the crystallization reaction. It has been shown that the sequence reversal of transformation stages occurs due to the large difference in the activation energy of crystallization of MSI and MSII. In addition, the change in the morphology of the crystals obtained by annealing the amorphous alloy below and above the glass transition temperature, T g, is reported.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A number of AgI based fast ion conducting glasses, with a general formula AgI---Ag2O---MxOy (MxOy=MoO3, SeO3, WO3, V2O5, P2O5, GeO2, B2O3, As2O3, CrO3) have been studied. A chemical approach is made to investigate the origin of fast ion conduction in these glasses. An index known as Image tructural Image npinning Image umber, SUN (S), has been defined for the purpose, based on the unscreened nuclear charge of silver ions and the equilibrium lectronegativities of the halide-oxyanion matrix in these glasses. The variation of the glass transition temperature, Tg, conductivity, σ, and the energy of activation, Ea, with the concentration of AgI are discussed in the light of the structural unpinning number. Conductivities increase uniformly in any given glass series as a smooth function of S and level off at very high values. The entire range of conductivity appears to vary as ln Image , where ln σ0 corresponds roughly to the conductivity of the hypothetical AgI glass and “a” is a constant which could be obtained as the slope in the graph of ln Ea versus S. It is suggested that the increase in the concentration of AgI beyond 75–80 mole% in the glass is not advantageous from the conductivity point of view.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Solid polymer electrolytes (SPEs) of poly(ethyleneoxide) and magnesium triflate, which are plasticized with propylene carbonate (PC), ethylene carbonate (EC) and a mixture of PC and EC, are studied for their conductivity, ac impedance of the Mg I SPE interface, cyclic voltammetry, infrared spectroscopy and differential scanning calorimetry. in the presence of plasticizers, the ionic conductivity (a) increases from a value of 1 x 10(-8) S cm(-1) to about 1 x 10(-4) S cm(-1) at ambient temperature. The a is found to follow a VTF relationship with temperature. The values of the activation energy, pre-exponential factor and equilibrium glass transition temperature are shown to depend on the concentration of plasticizer. Ac impedance studies indicate lower interfacial impedance of Mg/plasticized SPE than stainless steel/plasticized SPE. The impedance spectra are analyzed using a non-linear least square curve fitting technique and the interfacial resistance of Mg/plasticized SPE is evaluated. The cyclic voltammetric results suggest a quasireversible type of Mg/Mg2+ couple in plasticized SPE. (C) 2000 Elsevier Science B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We report numerical results for the phase diagram in the density-disorder plane of a hard-sphere system in the presence of quenched, random, pinning disorder. Local minima of a discretized version of the Ramakrishnan-Yussouff free energy functional are located numerically and their relative stability is studied as a function of the density and the strength of disorder. Regions in the phase diagram corresponding to liquid, glassy, and nearly crystalline states are mapped out, and the nature of the transitions is determined. The liquid to glass transition changes from first to second order as the strength of the disorder is increased. For weak disorder, the system undergoes a first-order crystallization transition as the density is increased. Beyond a critical value of the disorder strength, this transition is replaced by a continuous glass transition. Our numerical results are compared with those of analytical work on the same system. Implications of our results for the field-temperature phase diagram of type-II superconductors are discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Alternating differential scanning calorimetry (ADSC) studies were undertaken to investigate the effect of Tl addition on the thermal properties of As30Te70-xTlx ( 6 <= x <= 22 at%) glasses. These include parameters such as glass-transition temperature (T-g), changes in specific heat capacity (Delta C-p) and relaxation enthalpy (Delta H-NR) at the glass transition. It was found that T-g of the glasses decreased with the addition of Tl, which is in contrast to the dependence of T-g in As - Te glasses on the addition of Al and In. The change in heat capacity Delta C-p through the glass transition was also found to decrease with increasing Tl content. The addition of Tl to the As - Te matrix may lead to a breaking of As - Te chains and the formation of Tl+Te- AsTe2/2 dipoles. There was no significant dependence of the change of relaxation enthalpy, through the glass transition, with composition.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The authors have developed a simple continuous-cooling method to determine specific heat of liquids and solids in the temperature range 100-300 K. The technique employs very simple instrumentation and continuously records the sample temperature as it cools to the bath temperature through a calibrated heat link. They have obtained specific heat values which agree with the reported data to within 3% for the samples investigated. This method also facilitates easy detection of abrupt changes in specific heat, as demonstrated in the observation of glass transition in some organic glass-forming systems. The method is sensitive to the study of relaxing heat capacity in supercooled liquids.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Nowadays growing number of new active pharmaceutical ingredients (API) have large molecular weight and are hydrophobic. The energy of their crystal lattice is bigger and polarity has decreased. This leads to weakened solubility and dissolution rate of the drug. These properties can be enhanced for example by amorphization. Amorphous form has the best dissolution rate in the solid state. In the amorphous form drug molecules are randomly arranged, so the energy required to dissolve molecules is lower compared to the crystalline counterpart. The disadvantage of amorphous form is that it is unstable. Amorphous form tends to crystallize. Stability of amorphous form can be enhanced by adding an adjuvant to drug product. Adjuvant is usually a polymer. Polymers prevent crystallization both by forming bonds with API molecules and by steric hindrance. The key thing in stabilizing amorphous form is good miscibility between API and polymer. They have to be mixed in a molecular level so that the polymer is able to prevent crystallization. The aim of this work was to study miscibility of drug and polymer and stability of their dispersion with different analytical methods. Amorphous dispersions were made by rotary evaporator and freeze dryer. Amorphicity was confirmed with X-ray powder diffraction (XRPD) right after preparation. Itraconazole and theophylline were the chosen molecules to be stabilized. Itraconazole was expected to be easier and theophylline more difficult to stabilize. Itraconazole was stabilized with HPMC and theophylline was stabilized with PVP. Miscibility was studied with XRPD and differential scanning calorimetry (DSC). In addition it was studied with polarized light microscope if miscibility was possible to see visually. Dispersions were kept in stressed conditions and the crystallization was analyzed with XRPD. Stability was also examined with isothermal microcalorimetry (IMC). The dispersion of itraconazole and theophylline 40/60 (w/w) was completely miscible. It was proved by linear combination of XRPD results and single glass transition temperature in DSC. Homogenic well mixed film was observed with light microscope. Phase separation was observed with other compositions. Dispersions of theophylline and PVP mixed only partly. Stability of itraconazole dispersions were better than theophylline dispersions which were mixed poorer. So miscibility was important thing considering stability. The results from isothermal microcalorimetry were similar to results from conventional stability studies. Complementary analytical methods should be used when studying miscibility so that the results are more reliable. Light microscope is one method in addition to mostly used XRPD and DSC. Analyzing light microscope photos is quite subjective but it gives an idea of miscibility. Isothermal microcalorimetry can be one option for conventional stability studies. If right conditions can be made where the crystallization is not too fast, it may be possible to predict stability with isothermal microcalorimetry.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Alternating Differential Scanning Calorimetric (ADSC) and electrical switching studies have been undertaken on Ge20Se80-xBix glasses (1 <= x <= 13), to understand the effect of topological thresholds on thermal properties and electrical switching behavior. It is found that the compositional dependence of glass transition temperature (Tg), crystallization temperature (T-c1) and thermal stability (AT) of Ge20Se80-xBix glasses show anomalies at a composition x= 5, the rigidity percolation/stiffness threshold of the system. Further, unusual variations are also observed in different thermal properties, such as T-g, T-c1, Delta T, Delta C-p and Delta H-NR, at the composition x= 10, which indicates the occurrence of chemical threshold in these glasses at this composition. Electrical switching studies indicate that Ge20Se8o_RBig glasses with 5 11 exhibit threshold switching behavior and those with x = 12 and 13 show memory switching. A sharp decrease has been noticed in the switching voltages with bismuth concentration, which is due to the more metallic nature of bismuth and the presence of Bi+ ions. Further, a saturation is seen in the decrease in V-T around x = 6, which is related to bismuth phase percolation at higher concentrations of Bi. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Nearly one fourth of new medicinal molecules are biopharmaceutical (protein, antibody or nucleic acid derivative) based. However, the administration of these compounds is not always that straightforward due to the fragile nature of aforementioned domains in GI-tract. In addition, these molecules often exhibit poor bioavailability when administered orally. As a result, parenteral administration is commonly preferred. In addition, shelf-life of these molecules in aqueous environments is poor, unless stored in low temperatures. Another approach is to bring these molecules to anhydrous form via lyophilization resulting in enhanced stability during storage. Proteins cannot most commonly be freeze dried by themselves so some kind of excipients are nearly always necessary. Disaccharides are commonly utilized excipients in freeze-dried formulations since they provide a rigid glassy matrix to maintain the native conformation of the protein domain. They also act as "sink"-agents, which basically mean that they can absorb some moisture from the environment and still help to protect the API itself to retain its activity and therefore offer a way to robust formulation. The aim of the present study was to investigate how four amorphous disaccharides (cellobiose, melibiose, sucrose and trehalose) behave when they are brought to different relative humidity levels. At first, solutions of each disaccharide were prepared, filled into scintillation vials and freeze dried. Initial information on how the moisture induced transformations take place, the lyophilized amorphous disaccharide cakes were placed in vacuum desiccators containing different relative humidity levels for defined period, after which selected analyzing methods were utilized to further examine the occurred transformations. Affinity to crystallization, water sorption of the disaccharides, the effect of moisture on glass transition and crystallization temperature were studied. In addition FT-IR microscopy was utilized to map the moisture distribution on a piece of lyophilized cake. Observations made during the experiments backed up the data mentioned in a previous study: melibiose and trehalose were shown to be superior over sucrose and cellobiose what comes to the ability to withstand elevated humidity and temperature, and to avoid crystallization with pharmaceutically relevant moisture contents. The difference was made evident with every utilized analyzing method. In addition, melibiose showed interesting anomalies during DVS runs, which were absent with other amorphous disaccharides. Particularly fascinating was the observation made with polarized light microscope, which revealed a possible small-scale crystallization that cannot be observed with XRPD. As a result, a suggestion can safely be made that a robust formulation is most likely obtained by utilizing either melibiose or trehalose as a stabilizing agent for biopharmaceutical freeze-dried formulations. On the other hand, more experiments should be conducted to obtain more accurate information on why these disaccharides have better tolerance for elevating humidities than others.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Ion transport in a polymer-ionic liquid (IL) soft matter composite electrolyte is discussed here in detail in the context of polymer-ionic liquid interaction and glass transition temperature The dispersion of polymethylmetacrylate (PMMA) in 1-butyl-3-methylimidazolium hexafluorophosphate (BMIPF6) and 1-butyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide (BMITFSI) resulted in transparent composite electrolytes with a jelly-like consistency The composite ionic conductivity measured over the range -30 C to 60 C was always lower than that of the neat BMITFSI/BMIPF6 and LiTFSI-BMITFSI/LiTFSI-BMIPF6 electrolytes but still very high (>1 mS/cm at 25 degrees C up to 50 wt% PMMA) While addition of LiTFSI to IL does not influence the glass T-g and T-m melting temperature significantly dispersion of PMMA (especially at higher contents) resulted in increase in T-g and disappearance of T-m In general the profile of temperature-dependent ionic conductivity could be fitted to Vogel-Tamman-Fulcher (VTF) suggesting a solvent assisted ion transport However for higher PMMA concentration sharp demarcation of temperature regimes between thermally activated and solvent assisted ion transport were observed with the glass transition temperature acting as the reference point for transformation from one form of transport mechanism to the other Because of the beneficial physico-chemical properties and interesting ion transport mechanism we envisage the present soft matter electrolytes to be promising for application in electrochromic devices (C) 2010 Elsevier Ltd All rights reserved

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Thermal crystallization studies have been carried out on bulk, semiconducting AsxTe100−x glasses of different compositions using Differential Scanning Caloritmery. AsxTe100−x glasses with x < 40, are found to exhibit one glass transition and one crystallization. On the other hand, glasses with composition 40 less-than-or-equals, slantxless-than-or-equals, slant 50 show one glass transition and two crystallization reactions. It has been found that in glasses with x greater-or-equal, slanted 40, the two crystallization reactions progressively merge with an increase in arsenic concentration. Consequently AsxTe100−x glasses with x greater-or-equal, slanted 50 show only one crystallization. The composition dependence of crystallization temperatures and activation energies for crystallization estimated by Kissinger's method, show marked deviations at a composition x = 40. These observations can be explained in terms of the changes in the local structure of the material with composition.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Diglycidyl ether–bisphenol-A-based epoxies toughened with various levels (0–12%) of chemically reacted liquid rubber, hydroxyl-terminated poly(butadiene-co-acrylonitrile) (HTBN) were studied for some of the mechanical and thermal properties. Although the ultimate tensile strength showed a continuous decrease with increasing rubber content, the toughness as measured by the area under the stress-vs.-strain curve and flexural strength reach a maximum around an optimum rubber concentration of 3% before decreasing. Tensile modulus was found to increase for concentrations below 6%. The glass transition temperature Tg as measured by DTA showed no variation for the toughened formulations. The TGA showed no variations in the pattern of decomposition. The weight losses for the toughened epoxies at elevated temperatures compare well with that of the neat epoxy. Scanning electron microscopy revealed the presence of a dual phase morphology with the spherical rubber particles precipitating out in the cured resin with diameter varying between 0.33 and 6.3 μm. In contrast, a physically blended rubber–epoxy showed much less effect towards toughening with the precipitated rubber particles of much bigger diameter (0.6–21.3 μm).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The specific heat Cp of glassy Ge20Se80−xBix (0 ≤ × ≤ 12) samples is investigated. The Cp at 323K and the ΔCp at glass transition temperature Tg1 show anomalous features around x = 8 at.%, where p−n conduction type inversion also take place. These features are discussed in the light of Phillips model of phase separation in these glasses at the microscopic level.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Electrolytes based on polyethylene glycol (PEG, mol.wt.8000) and LiCl of compositions, (PEG)(x)LiCl, x=4, 6, 8, 10, 12, 40, 60, where x is the O/Li ratio, were prepared by solution casting from methanol solutions. FTIR studies indicate that the ether oxygens of the polymer chain participate in Li+ ion conduction. The presence of a salt-polymer complex that melts around 190 degrees C was evidenced by DSC measurements for the electrolytes with compositions x<12. The highest conductivity was obtained at the composition x=10 which was attributed to the presence of a mostly amorphous compound. NMR measurements indicated two regions of motional narrowing, one attributable to the glass transition and another to translational diffusion.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Based on an isothermal, isobaric simulation the structure and properties of the plastic crystalline phases of C60 and neopentane have been examined. Instantaneous cooling of the plastic crystalline phases of both C60 and neopentane leads to orientational glassy phases. These are accompanied by significant slowing down of reorientational motion. Constant pressure quench experiments on C60 yield a glass transition temperature of around 80 K.