906 resultados para frequência respiratória


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents a theoretical and numerical analysis for the cascading of frequency selective surfaces, which uses rectangular patches and triangular Koch fractals as elements. Two cascading techniques are used to determine the transmission and reflection characteristics. Frequency selective surfaces includes a large area of Telecommunications and have been widely used due to its low cost, low weight and ability to integrate with others microwaves circuits. They re especially important in several applications, such as airplane, antennas systems, radomes, rockets, missiles, etc.. FSS applications in high frequency ranges have been investigated, as well as applications of cascading structures or multi-layer, and active FSS. Furthermore, the analyses uses the microwave circuit theory, with the Floquet harmonics, it allows to obtain the expressions of the scattering parameters of each structure and also of the composed structure of two or more FSS. In this work, numeric results are presented for the transmission characteristics. Comparisons are made with experimental results and simulated results using the commercial software Ansoft Designer® v3. Finally, some suggestions are presented for future works on this subject

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main objective of this work is to optimize the performance of frequency selective surfaces (FSS) composed of crossed dipole conducting patches. The optimization process is performed by determining proper values for the width of the crossed dipoles and for the FSS array periodicity, while the length of the crossed dipoles is kept constant. Particularly, the objective is to determine values that provide wide bandwidth using a search algorithm with representation in bioinspired real numbers. Typically FSS structures composed of patch elements are used for band rejection filtering applications. The FSS structures primarily act like filters depending on the type of element chosen. The region of the electromagnetic spectrum chosen for this study is the one that goes from 7 GHz to 12 GHz, which includes mostly the X-band. This frequency band was chosen to allow the use of two X-band horn antennas, in the FSS measurement setup. The design of the FSS using the developed genetic algorithm allowed increasing the structure bandwidth

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wavelet coding has emerged as an alternative coding technique to minimize the fading effects of wireless channels. This work evaluates the performance of wavelet coding, in terms of bit error probability, over time-varying, frequency-selective multipath Rayleigh fading channels. The adopted propagation model follows the COST207 norm, main international standards reference for GSM, UMTS, and EDGE applications. The results show the wavelet coding s efficiency against the inter symbolic interference which characterizes these communication scenarios. This robustness of the presented technique enables its usage in different environments, bringing it one step closer to be applied in practical wireless communication systems

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Frequency selective surfaces (Frequency Selective Surface - FSS) are often used in various applications in telecommunications. Some of these applications may require that these structures have response with multiple resonance bands. Other applications require that the FSS response have large frequency range, to meet the necessary requirements. FSS to design with these features there are numerous techniques cited in the scientific literature. Thus, the purpose of this paper is to examine some common techniques such as: Overlap of FSS; Elements combined; Elements Elements convolucionados and fractals. And designing multiband FSS and / or broadband selecting simple ways in terms of construction and occupy the smallest possible space, aiming at practical applications. Given these requirements, three projects FSS were performed: a technology applied to IEEE 802.11 a/b/g/n and two projects for application in UWB. In project development, commercial software Ansoft DesignerTM and experimental results were satisfactory was used

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to analyze the reproducibility of the electromyography signal's parameters (EMG) in the frequency domain used in the characterization of localized muscle fatigue. Fifteen male subjects underwent a fatigue test based on isometric knee extension, being held at three different times at intervals of seven days. To assess the reproducibility of data between the tests we calculated the correlation coefficient (ICC) for the median frequency (MF) in total exercise time (MFT), MF obtained for every 10% of exercise time (MF10%) and the powers of the frequency bands obtained by dividing the power spectrum at windows of 20 Hz. The results showed: (1) excellent reproducibility for MFT, (2) good reproducibility for MF10%, and (3) greater variation in the signal EMG bands from 20 to 120 Hz, especially at the bands of 20-40 Hz and 40-60 Hz, which showed greater sensitivity to the process of muscle fatigue. We conclude that the MF is a variable that shows good reproducibility and that the fragmented analysis of the power spectrum, by means of frequency bands, showed that significant variations occur in the EMG signal during the installation of the fatigue process, having potential to become a new method for the characterization of localized muscle fatigue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To analyze the effect of arm bracing posture on respiratory muscle strength and pulmonary function in patients with Chronic Obstructive Pulmonary Disease (COPD).Methods: 20 patients with COPD (11 male; 67 +/- 8 years; BMI 24 +/- 3 Kg . m(-2)) were submitted to assessments of Maximal Inspiratory and Expiratory Pressures (MIP and MEP, respectively) and spirometry with and without arm bracing in a random order. The assessment with arm bracing was done on standing position and the height of the support was adjusted at the level of the ulnar styloid process with elbow flexion and trunk anterior inclination of 30 degrees promoting weight discharge in the upper limbs. Assessment without arm bracing was also performed on standing position, however with the arms relaxed alongside the body. The time interval between assessments was one week.Results: MIP, MEP and maximal voluntary ventilation (MW) were higher with arm bracing than without arm bracing (MIP 64 +/- 22 cmH(2)O versus 54 +/- 24 cmH(2)O, p = 0,00001; MEP 104 +/- 37 cmH(2)O versus 92 +/- 37 cmH(2)O, p = 0,00001 and MW 42 +/- 20 L/min versus 38 +/- 20 L/min, p = 0,003). Other variables did not show statistical significant difference.Conclusion: The arm bracing posture resulted in higher capacity to generate force and endurance of the respiratory muscles in patients with COPD. (C) 2009 Published by Elsevier Espana, S.L. on behalf of Sociedade Portuguesa de Pneumologia. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: It was already evidenced decreased heart rate variability (HRV) in chronic obstructive pulmonary disease (COPD) patients at rest.Objective: In order to insert new elements in the literature regarding this issue, we evaluated geometric index of HRV in COPD subjects.Method: We analyzed data from 34 volunteers, divided into two groups according to spirometric values: COPD (17 volunteers, FEV1/FVC = 47.3 +/- 10.2; FEV1 = 50.8 +/- 15.7) and control (17 volunteers, FEV1/FVC = 78.8 +/- 10.8; FEV1 = 100.1 +/- 14.7). For analysis of HRV indexes the volunteers remained in the supine position for 30 minutes. We analyzed the following indexes: triangular index (RRtri), triangular interpolation of RR intervals (TINN) and Poincare plot (SD1, SD2 and SD1/SD2). Student t test for unpaired samples and Mann-Whitney test were used for data analysis.Results: We observed statistically significant reductions in geometric indexes in the COPD group: RRtri (0.043 +/- 0.01 vs. 0.059 +/- 0.02; p = 0.018), TINN (105.88 +/- 51.82 vs. 151.47 +/- 49.9; p=0.014), SD1 (9.76 +/- 4.66 vs. 14.55 +/- 6.04; p = 0.014) and SD2 (34.86 +/- 17.02 vs. 51.51 +/- 18.38; p = 0.010). SD1/5D2 (0.30 +/- 0.11 vs. 0.28 +/- 0.07; p = 0.605) were not significantly different between groups. Patients with COPD presented a visual analysis of Poincare plot of lower dispersion of RR intervals both beat to beat and the long term.Conclusion: Subjects with COPD present reduction of geometric indexes of HRV, indicating reduced heart rate variability. (C) 2010 Sociedade Portuguesa de Pneumologia. Published by Elsevier Espana, S.L. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O sistema nervoso autônomo (SNA) desempenha um papel importante na regulação dos processos fisiológicos do organismo humano tanto em condições normais quanto patológicas. Dentre as técnicas utilizadas para sua avaliação, a variabilidade da frequência cardíaca (VFC) tem emergido como uma medida simples e não-invasiva dos impulsos autonômicos, representando um dos mais promissores marcadores quantitativos do balanço autonômico. A VFC descreve as oscilações no intervalo entre batimentos cardíacos consecutivos (intervalos R-R), assim como oscilações entre frequências cardíacas instantâneas consecutivas. Trata-se de uma medida que pode ser utilizada para avaliar a modulação do SNA sob condições fisiológicas, tais como em situações de vigília e sono, diferentes posições do corpo, treinamento físico, e também em condições patológicas. Mudanças nos padrões da VFC fornecem um indicador sensível e antecipado de comprometimentos na saúde. Uma alta variabilidade na frequência cardíaca é sinal de boa adaptação, caracterizando um indivíduo saudável, com mecanismos autonômicos eficientes, enquanto que, baixa variabilidade é frequentemente um indicador de adaptação anormal e insuficiente do SNA, implicando a presença de mau funcionamento fisiológico no indivíduo. Diante da sua importância como um marcador que reflete a atividade do SNA sobre o nódulo sinusal e como uma ferramenta clínica para avaliar e identificar comprometimentos na saúde, este artigo revisa aspectos conceituais da VFC, dispositivos de mensuração, métodos de filtragem, índices utilizados para análise da VFC, limitações de utilização e aplicações clínicas da VFC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The restriction of physical fitness is directly related with hypertension and sleep disorders, while the respiratory muscle strength is associated with hypertension, but the literature is scarce regarding its relationship with sleep disorders and particularly with excessive daytime sleepiness. Objectives: To compare physical fitness and strength of respiratory muscles between people with hypertension with excessive daytime sleepiness (EDS) and non EDS people, those who do not feel excessive daytime sleepiness, in addition to relate aerobics resistance and functional mobility of patients. Methods: An observational, analytical and transversal study, evaluated 32 elderly with hypertension, divided into two groups (EDS and non EDS), in which the following topics were measured; respiratory muscular strength, functional fitness, level of physical activity, level of excessive daytime sleepiness, quality of sleep and intensity of the patients snoring. Results: There was a significant difference in the level of EDS (P=0,00) and quality of sleep (p=0,03), however, the data related to snoring intensity (p=0,18), maximum inspiratory pressure PImax (p=0,39) and maximum expiratory pressure PEmax (p=0,98) did not show any difference. Also, no significant difference was observed concerning physical fitness, presenting p=0,08 for the sitting and getting up test on the chair in 30 ; p=0,54 for the extension and flexing of the elbow test in 30 ; p=0,38 for the walking test 6 ; p=0,38 for the parking gear test 2 , p=0,08 for the sitting and reaching test; p=0,42 for the scratching the back test; p=0,49 for the getting up and walking test; and p=0,62 for the global rate of activity limitation. There was moderate positive correlation between 6MWT and 2MST, r=0,54 (p=0,01) and negative moderate correlation between 6MWT and TUG, r=-0,61 (p=0,000) and between 2MST and TUG, r=-0,60 (p=0,000). Conclusion: The presence of EDS in the hypertension people studied, showed a bad quality of sleep, however this sleepiness did not influence the strength of the respiratory muscles. The physical fitness came out diminished in all hypertension people, regardless of the presence or non presence of sleep disturbance; and there is a close relationship between cardiovascular resistance and physical mobility, since when there is less cardiovascular resistance, there is precarious physical mobility and vice-versa

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Physical Exercise (PE) is a necessary component in the management in COPD patients, where respiratory symptoms are associated with reduced functional capacity. Even with the increase in the number of studies that have been published and the therapeutics success using aquatic therapy approach, studies using PE in water in COPD patients are so few. Objective: the aim of this present study was to analyze the effects of low intensity water exercise in COPD patients, developed in two different places aquatic and ground. Methods: This is a randomized clinical trial study, 42 patients with moderate to very severe DPOC were recruited for the study, mean age of 63,2  10,9 years old. Randomized in 3 groups: Control Group (CG), Land Group (LG) and Water Group (WG). The PE protocol was performed in a period of 8 weeks, with frequency of 3 times per week. The CG participated in an educational program. All the patients were assessed twice through spirometry, respiratory muscular strength, the 6-min walk test, the quality of life (SF-36 and SGRQ), the LCADL, the MRC, the BODE index and the upper limbs (UP) incremental test. Results: There was a significant difference after the approaches in DP6 from the WG (p=0,02); in VEF1 in LG (p=0,00) and WG (p=0,01); in MIP in LG (p=0,01) and WG (p=0,02); in MEP in LG (p=0,02) and WG (p=0,01); the MRC decreases in WG (p=0,00). there was an increase of the weight supported by the UP in LG (p=0,00) and WG (p=0,01). The LG showed an increase of the quality of life represented by the SGRQ total score (p=0,00). The BODE index decreased in LG (p=0,00) and WG (p=0,01). In LCDAL, the LG showed a decrease. Conclusion: This data in this present study suggest that both approaches of low intensity exercise showed to be beneficial in moderate to very severe COPD patients. The WG showed additional benefits in physical function, pointing to a new therapeutic modality for COPD patients

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The clinical importance of evaluating the respiratory muscles with a variety of tests has been proposed by several studies, once that the combination of several tests would allow a better diagnosis and therefore, a better clinical follow of disorders of the respiratory muscles. This study aimed to evaluate the feasibility of adapting a national electronic manovacuometer to measure the nasal inspiratory pressure (study 1) and analyze the level of load intensity of maximum voluntary ventilation, as well as the variables that may influence this maneuver in healthy subjects (study 2). We studied 20 healthy subjects by a random evaluation of two measures of SNIP in different equipments: a national and an imported. In study 2 it was analyzed the intensity of the load of MVV test, change in pressure developed during the maneuver, the possible differences between genders, and the correlations between the flow developed in the test and the result of MVV. In study 1 it was found the average for both measures of nasal inspiratory pressures: 125 ± 42.4 cmH2O for the imported equipment and 131.7 ± 28.7 cmH2O for the national one. Pearson analysis showed a significant correlation between the average, with a coefficient r = 0.63. The average values showed no significant differences evaluated by paired t test (p> 0.05). In the Bland-Altman analysis it was found a BIAS = 7 cmH2O, SD 32.9 and a confidence interval of - 57.5 cmH2O up to 71.5 cmH2O. In the second study it was found significant differences between the genders in the air volume moved, being higher in males 150.9 ± 13.1 l / min vs 118.5 ± 15.7 L / min for (p = 0.0002, 95% CI 44.85 to 20:05). Regarding the inspiratory and expiratory loading, they were significantly higher in men than in women, peak inspiratory pressure (34.7 ± 5.3 cmH2O vs 19.5 ± 4.2 cmH2O, 95% CI - 18.0 to -12.3, p <0.0001), peak expiratory (33.8 vs. 23.1 ± 5.9 cmH2O ± 5.4 cmH2O, 95% CI -17.1 to - 4.6, p <0.0001), and the delta pressure (59.7 ± 10 cmH2O vs 36.8 ± 8.3 cmH2O, 95% CI 14.5 to 31.2, p <0.0002). The Pearson correlation showed that the flow generated by the maneuver is strongly correlated with the delta-expiratory pressure / inspiratory (r2= 0.83,R = 0.91, 95%IC 0.72 a 0.97 e p< 0.0001).Through these results we suggest that the national electronic manovacuometer is feasible and safe to perform the sniff test in healthy subjects. For the MVV, there are differences between the genders in the intensity of pressure developed during the maneuver. We found a load intensity considered low during the MVV, and found a strong correlation between the flow generated in the test and the delta pressure expiratory / inspiratory

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Obesity leads to alteration of lung volumes and capacities due to accumulation of fat in the chest wall and abdomen. Few studies have shown that weight loss induced by surgery improves lung function. Our objective was to evaluate the anthropometric development, pulmonary function, respiratory muscle, strength and endurance after weight loss induced by bariatric surgery. Methods: We evaluated in pre and post operative period variables of weight, BMI, NC, WHR and spirometric and respiratory pressure. Results: 39 subjects were evaluated, with age mean 35.9 ± 10.9 years, predominantly by women (76.3%). The weight mean decreased from 124.8 ± 17.5 kg to 88.8 ± 14.28 kg in post operative. The mean BMI ranged from 47,9 ± 5,6 Kg/m² to 34,3 ± 4,75 Kg/m². There was a significant increase in FVC from 3,63 ± 0,94 to 4,01±1,03, FEV1 from 3,03 ± 0,72 to 3,39 ± 0,85, FEF 25-75% from 3,41 ± 0,72 to 3,82 ± 0,94, PEF from 6,56 ± 1,47 to 7,81 ± 1,69, ERV from 0,35 ± 0,39 to 0,66 ± 0,38, MVV ranged from 103,43 ± 22,21 to 137,27 ± 29,84, all of them to p<0,01. The MIP and MEP showed no significant difference in pre and post operative. It was noted that for every centimeter reduced in neck circumference, an increase of 0.06 in FVC and 5.98 in MVV is observed. This is also observed in weight and BMI. Conclusion: We conclude that weight loss induced by bariatric surgery in obese provides a significant improvement in lung function and reduction of fat around the neck is more important in the generation of lung volume than the reduction of BMI

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Obesity may affect the respiratory system, causing changes in respiratory function and in the pulmonary volumes and flows. Objectives: To evaluate the influence of obesity in the movement of thoracoabdominal complex at rest and during maximal voluntary ventilation (MVV), and the contribution between the different compartments of this complex and the volume changes of chest wall between obese and non-obese patients. Materials and Methods: We studied 16 patients divided into two groups: the obese group (n = 8) and group non-obese (n = 8). The two groups were homogeneous in terms of spirometric characteristics (FVC mean: 4.97 ± 0.6 L - 92.91 ± 10.17% predicted, and 4.52 ± 0.6 L - 93.59 ± 8.05%), age 25.6 ± 5.0 and 26.8 ± 4.9 years, in non-obese and obese respectively. BMI was 24.93 ± 3.0 and 39.18 ± 4.3 kg/m2 in the groups investigated. All subjects performed breathing calm and slow and maneuver MVV, during registration for optoelectronic plethysmography. Statistical analysis: we used the unpaired t test and Mann-Whitney. Results: Obese individuals had a lower percentage contribution of the rib cage abdominal (RCa) during breathing at rest and VVM. The variation of end expiratory (EELV) and end inspiratory (EILV) lung volumes were lower in obese subjects. It has been found asynchrony and higher distortion between compartments of thoracoabdominal complex in obese subjects when compared to non-obese. Conclusions: Central obesity impairs the ventilation lung, reducing to adaptation efforts and increasing the ventilatory work

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A obesidade é uma epidemia global em alarmante ascensão. Caracterizada pelo excesso de gordura corporal subcutânea, de caráter multifatorial, está relacionada ao surgimento de diversas co-morbidades, entre elas, várias alterações respiratórias, estas se tornam mais intensas quanto maior o grau de obesidade. Não há consenso na relação entre os marcadores de adiposidade geral ou específicos e suas repercussões sobre a função ventilatória, especialmente em relação à sobrecarga muscular respiratória. Objetivo: Analisar a relação entre marcadores antropométricos e variáveis espirométricas e de força muscular respiratória em indivíduos com obesidade mórbida. Métodos: Estudo transversal entre setembro de 2007 e outubro de 2012. Participaram da pesquisa 163 obesos mórbidos (37.1±9.8 anos e IMC=49.0±5.88 Kg/m2) sem alterações espirométricas. Foram observadas as associações entre Índice de Massa Corporal-IMC, adiposidade localizada (Circunferências de Pescoço-CP, Cintura-CC e Quadril-CQ), percentual de gordura corporal através do Índice de Adiposidade Corporal-IAC, volumes e capacidades pulmonares (CVF, VEF1 e VRE) e pressões respiratória estática (PIM e PEM) e dinâmica (VVM). Resultados: O VRE foi o volume mais afetado pela obesidade (apenas 41%predito) e mostrou associação negativa nas relações com todos os marcadores de adiposidade (IMC: r=-0.52; IAC: r=-0.21; CC: r=-0.44; CP: r=-0.25 e CQ: r=-0.28). Há relação inversa entre o percentual de gordura corporal (IAC) com a CVF (r=-0.59), o VEF1(r=-0.56) e o VVM (r=-0.43). As pressões respiratórias são justificadas principalmente pela adiposidade ao redor do pescoço e o IAC. Nossos dados de força muscular respiratória foram melhores associados aos valores de referências sugeridos pelas equações de Harik-Klan et al (1998) para PIM (R²=0.72) e com a equação proposta por Neder et al (1999) para PEM (R²=0.52). Em um modelo de regressão linear, as variáveis de adiposidade não justificam a VVM, já o VEF1 explica 62% da variância da VVM em obesos mórbidos. Conclusão: O percentual da adiposidade corporal e a circunferência do pescoço estão associados com a força muscular e capacidade de gerar fluxo respiratório de obesos mórbidos. Sugerimos a equação elaborada por Harik-Klan et al (1998) para obtenção de valores preditos de PIM e a equação proposta por Neder et al (1999) para valores de normalidade da PEM em sujeitos com obesidade mórbida. Foi possível fornecer uma equação de referência específica para VVM em obesos mórbidos