961 resultados para fast sample preparation method
Resumo:
A chromatographic method was developed for cholesterol determination in feed for ruminants using response surface methodology. Among the five approaches of sample preparation methods tested, the saponification of the sample without heating presented less interference in the gas chromatography. The method presented a relative standard deviation (RSD) of 4.3%, recoveries between 84 and 87% and detection limit of 0.001 mg of cholesterol per g of feed.
Resumo:
A simple liquid chromatographic method for the simultaneous determination of creatinine, hippuric acid, mandelic acid, phenylglyoxylic acid and o, m and p-methylhippuric acids was developed and validated. Sample preparation was only dilution with water (1:10), followed by centrifugation. Analysis was performed in a reversed phase column (Lichrospher RP 8ec), 250 x 4.0 mm, with isocratic elution with phosphate buffer pH 2.3 and acetonitrile (90:10, v/v). The method presents adequate linearity, precision and accuracy and allows the simultaneous determination of the biomarkers of exposure to toluene, xylene and styrene together with creatinine, reducing cost and laboratory time.
Resumo:
This work reports an alternative, fast and robust method, for the determination of total As, As(III) and As(V) by HG-AAS without the use of prereductants. The method is based on the different rates of arsine formation of the inorganic As species and the effect of As(III) in the signal obtained for total As. Groundwater and mineral spiked waters were used to sample preservation evaluation. The method was validated by the determination of As in SRM 1640 and used in the determination of total As and its inorganic species in groundwater samples collected from mines in the Iron Quadrangle - MG.
Resumo:
A simple ultra-performance liquid chromatographic method for the simultaneous determination of sildenafil citrate and tadalafil was developed and validated. Sample preparation was dissolution in methanol, followed by centrifugation and dilution (1:10) with methanol. Analysis was performed in an Acquity® UPLC system with Acquity® BEH C18 column (2.1 x 50 mm, with 1.7 μm particles). The elution was isocratic with phosphate buffer pH 2.3 and acetonitrile (65:35, v/v) at a flow rate of 0.7 mL/min. The method presented adequate specificity, linearity, precision and accuracy and allowed the determination of the drugs in seized forensic samples.
Resumo:
This paper reports the development of an easy, fast and effective procedure for the verification of the ideal gas law in splitless injection systems in order to improve the response. Results of a group of pesticides were used to demonstrate the suitability of the approach. The procedure helps establish experimental parameters through theoretical aspects. The improved instrumental response allowed extraction with lower sample volumes, the minimization of time and costs and the simplification of sample preparation.
Resumo:
A method using Liquid Phase Microextraction for simultaneous detection of citalopram (CIT), paroxetine (PAR) and fluoxetine (FLU), using venlafaxine as internal standard, in plasma by high performance liquid chromatography with fluorescence detection was developed. The linearity was evaluated between 5.0 and 500 ng mL-1 (r > 0.99) and the limit of quantification was 2.0, 3.0 and 5.0 ng mL-1 for CIT, PAR and FLU, respectively. Therefore, it can be applied to therapeutic drug monitoring, pharmacokinetics or bioavailability studies and its advantages are that it necessary relatively inexpensive equipment and sample preparation techniques.
Resumo:
This study describes a simple, fast and reproducible method using RP-HPLC-UV, in a gradient system, for quantification of reserpine in Rauvolfia sellowii stem bark. The analysis were carried out on a C18 column; mobile phase was water and acetonitrile, and separations were carried out in 10 min, flow rate of 1.0 mL min-1, 25 ºC and 268 nm. The validation data showed that the method was specific, accurate, precise and robust. Results were linear over a range of 0.625-40.0 μg mL-1, and the mean recovery was 95.1%. The amount of reserpine found in the dried stem bark was 0.01% (m/m).
Resumo:
A high performance liquid chromatographic-diode array detection method for the determination of busulfan in plasma was developed and validated. Sample preparation consisted of protein precipitation followed by derivatization with sodium diethyldithiocarbamate and liquid-liquid extraction with methyl-tert-butyl ether. Chromatograms were monitored at 277 nm. Separation was carried out on a Lichrospher RP 18 column (5 µm, 250 x 4 mm). The mobile phase consisted of water and acetonitrile (20:80, v/v). The method presented adequate specificity, linearity, precision and accuracy and allowed reliable determination of busulfan in clinical plasma samples, being applied to three patients submitted to bone marrow transplantation.
Resumo:
This is an overview of LC-MS techniques applied for macrolide determination in food, including sample preparation and method validation, as well as the policies adopted by international agencies regarding their presence in food. Techniques for the analysis of macrolides in food normally include solid phase or liquid-liquid extraction followed by HPLC. UHPLC presents advantages in running time, detectability and solvent consumption. Triple-quadrupoles are the most common analyzers in instruments used for the determination of contaminants in food, but time-of-flight and ion-trap spectrometers have been successfully applied for analyses focusing on the investigation of structural formula or the presence of degradation products.
Resumo:
A method based on pyrohydrolysis was proposed for cement sample preparation and further chloride determination by spectrophotometry using flow injection analysis. Analytical parameters were evaluated and, under the selected conditions, the calibration curve was linear in the range of 0.2 to 10.0 µg mL-1 with r2 = 0.998. The limit of detection was5 µg g-1 of chloride and the relative standard deviation was less than 7%. The proposed pyrohydrolysis method is relatively simple and can be used for sample preparation for further spectrophotometric determination of low concentrations of chloride in cement.
Resumo:
This paper describes the development of methods in micro-scale for the determination of K, Mg, Na and Zn in meat by atomic spectrometry techniques. The limits of detection (LOD) for K and Na by microdigestion were 0.18 and 0.20 mg g-1, respectively whereas LOD for Mg and Zn by microsolubilization with TMAH were 2.40 and 18.4 µg g-1, respectively. The RSD values were lower than 6.0% and the CRMs analyzed showed values with 95% agreement. The proposed methods are simple, fast and use small amounts of sample (around 10 mg) yet do not require special equipment for sample preparation.
Resumo:
This paper describes the evaluation of a new method of sample preparation using a cold finger system with continuous water flow for rice analysis by flame atomic absorption spectrometry. The limits of detection for Cu, Fe, Mn and Zn for the proposed method were 0.36, 1.84, 2.12 and 0.16 mg kg-1, respectively. The RSDs were lower than 6.0% for all elements and the CRM analyzed showed values with 95% agreement. The proposed method is simple and safe for the proposed objective and does not require the use of mixtures of acid or special equipment for sample preparation.
Resumo:
Difenoconazole residues in strawberry fruit cultivated in pots were estimated using the solid-liquid extraction with low temperature partition (SLE/LTP) method for sample preparation and gas chromatography with electron capture detection (GC/ECD) for analysis. The optimized method presented excellent recovery values from fortified samples and reproducibility (average recovery values ≥ 98%; CV values < 15%). Linearity of response was demonstrated (r = 0.995) with a detection limit of 9 µg kg-1. The method was successfully applied for the determination of difenoconazole residues in strawberries. Based on these results, the fungicide dissipates quickly, but the residual concentration increases after multiple applications.
Resumo:
Considering the possibility that pesticides used in cattle raising produce residues in milk and cause harm to public health, this study developed a multiresidue method for determination of pesticide residues in bovine milk, using a modified QuEChERS method for sample preparation, and quantification by GC-MS/MS. The method proved to be efficient, resulting in satisfactory recoveries in the range 71.1 to 117.4%, for 45 of the 48 compounds analyzed with RSD values < 17.3%. The method LOD and LOQ were3.0 and 10.0 µg L-1, respectively, except for cyfluthrin which showed 7.5 and 25.0 µg L-1.
Resumo:
In this research, scanometry was used as a new, simple, fast and inexpensive method for a colorimetric determination of Mn2+ ion in water samples and thermocouple wire through the use of periodate reagent in an acidic medium. The results showed the oxidization of colorless Mn2+ ion by periodate and the formation of a purplish MnO4- ion. The system had a linear range of 1.0 to 70.0 µg mL-1 Mn2+ ion with a detection limit of 0.314 µg mL-1 and a relative standard deviation of 2.77% for G color value. This method has the capability to determine low levels of Mn2+ ion in thermocouple wire and water samples.