910 resultados para content distribution networks
Resumo:
The work presented in this paper belongs to the power quality knowledge area and deals with the voltage sags in power transmission and distribution systems. Propagating throughout the power network, voltage sags can cause plenty of problems for domestic and industrial loads that can financially cost a lot. To impose penalties to responsible party and to improve monitoring and mitigation strategies, sags must be located in the power network. With such a worthwhile objective, this paper comes up with a new method for associating a sag waveform with its origin in transmission and distribution networks. It solves this problem through developing hybrid methods which hire multiway principal component analysis (MPCA) as a dimension reduction tool. MPCA reexpresses sag waveforms in a new subspace just in a few scores. We train some well-known classifiers with these scores and exploit them for classification of future sags. The capabilities of the proposed method for dimension reduction and classification are examined using the real data gathered from three substations in Catalonia, Spain. The obtained classification rates certify the goodness and powerfulness of the developed hybrid methods as brand-new tools for sag classification
Resumo:
Tässä insinöörityössä suunniteltiin Helsingin ammattikorkeakoululle jakeluverkoissa tapahtuvien oikosulkujen symmetristen komponenttien laskutavan havainnollistamiseen sopiva sijaiskytkentä. Sijaiskytkennässä tärkeitä huomioitavia asioita olivat mm. jännitetaso, havainnollistavien muuntajien oikosulkukestoisuus, jatkokäyttö laboratoriotyönä ja yleinen havainnollistavuus. Työssä on aluksi perehdytty symmetristen komponenttien ja jakeluverkoissa tapahtuvien oikosulkujen teoriaan. Tämän jälkeen mitoitettiin tarvittavan kytkennän komponenttien jännite- ja virtakestoisuudet mahdolliset lisäkäytöt huomioiden. Näiden rajoitusten mukaan perusteella työtä ruvettiin toteuttamaan. Työssä tilattiin sähkön 40 V:n pääjännitetasolle alentava muuntaja syöttämään oikosulun kestävää muuntajaa, jolla simuloitiin jakeluverkon yleisimpiä vikatyyppejä. Jälkimmäiselle muuntajalle mitoitettiin ja hankittiin sisäistä impedanssia vastaava induktanssi. Tämän avulla rakennettiin kokonaisuus, jonka avulla voidaan simuloida kaikkia tapahtuvia oikosulkuja vastaavat sijaiskytkennät. Työhön jätettiin kehittämisvaraa ja muita laboratoriotyön rakentamismahdollisuuksia tulevien insinööritöiden tekijöille.
Resumo:
We explain the choice between franchising and vertical integration by estimating a model of relative performance in a sample of 250 Spanish car distributors, controlling for self-selection and including environmental factors. The method allows us to estimate performance counterfactuals. Organizational choice seemingly aims to contain moral hazard for both distributors and manufacturers but it is subject to start-up constraints and switching costs. While the market for franchises remained underdeveloped, information asymmetries led to the opening of integrated outlets. Their subsequent conversion into franchised outlets probably involved prohibitive transaction costs. Consequently, they performed worse than would have been expected had they been independent, as confirmed by the systematic improvement observed when they were in fact converted. The timing of such conversions suggests that switching costs were prohibitive until firms developed a substantial cushion of temporary contracts, previously forbidden by regulation.
Resumo:
We study the effect of organizational choice and institutions on the performance ofSpanish car dealerships. Using outlet-level data from 1994, we find that verticallyintegrateddealerships showed substantially lower labor productivity, higher labor costs andlower profitability than franchised ones. Despite these gaps in performance, no verticallyintegratedoutlet was separated until 1994, yet the few outlets that were eventuallyseparated systematically improved their performance. We argue that the conversion ofintegrated outlets into franchised ones involved significant transaction costs, due to aninstitutional environment favoring permanent, highly-unionized employment relations. Inline with this argument, we find that the observed separations occurred in distributionnetworks that underwent marked reductions in worker unionization rates, following thelegalization of temporary labor contracts.
Resumo:
This work aims the applicability of the Transient electromagnetic method at an arid and semiarid environmental condition in the Santiago Island – Cape Verde. Some seashore areas of this island show an increasing salt contamination of the groundwater. The main objective of present work is to relate this water-quality condition with parameters taken from the transient sounding’s data. In this context, transient soundings have been acquired from 2005 through 2009, at several chosen valleys near the sea, in a mean rate of one field campaign each year. The first phase of this work was the understanding of the geophysical method details, problems and applicability, as the chosen and acquired equipment was the first one to be permanently available to the Portuguese geosciences community. This first phase was also accomplished with field tests. Interpretation of the transient sounding’s data curves were done by application of 1-D inversion methods already developed and published, as also with quasi 2-D and quasi 3-D inversion algorithms, where applicability was feasible. This was the second phase. The 2-D and 3-D approximation results are satisfactory and promising; although a higher spatial sounding’s density should certainly allow for better results. At phase three, these results have been compared against the available lithologic, hydrologic and hydrochemical data, in the context of Santiago’s island settings. The analyses of these merged data showed that two distinct origins for the observed inland groundwater salinity are possible; seashore shallow mixing with contemporary seawater and mixing with a deep and older salty layer from up flow groundwater. Relations between the electric resistivity and the salt water content distribution were found for the surveyed areas. To this environment condition, the electromagnetic transient method proved to be a reliable and powerful technique. The groundwater quality can be accessed beyond the few available watershed points, which have an uneven distribution.
Resumo:
RESUME Dès le printemps 2004, la construction d'une 2ème ligne de métro est entreprise dans la ville de Lausanne en Suisse. En reliant Ouchy, au bord du lac Léman (alt. 373 m) à Epalinges (alt. 711 m), le nouveau métro "M2" traversera dès 2008 l'agglomération lausannoise du Sud au Nord sur une distance de 6 km. Depuis l'avant-projet, en 1999, une grande quantité de données géologiques a été récolté et de nombreux forages exécutés sur le site. Ceci nous a donné une occasion unique d'entreprendre une étude de microgravimétrique urbaine de détail. Le mode de creusement du tunnel dépend fortement des matériaux à excaver et il est classiquement du domaine du géologue, avec ses connaissances de la géologie régionale et de la stratigraphie des forages, de fournir à l'ingénieur un modèle géologique. Ce modèle indiquera dans ce cas l'épaisseur des terrains meubles qui recouvrent le soubassement rocheux. La représentativité spatiale d'une information très localisée, comme celle d'un forage, est d'autant plus compliquée que le détail recherché est petit. C'est à ce moment là que la prospection géophysique, plus spécialement gravimétrique, peut apporter des informations complémentaires déterminantes pour régionaliser les données ponctuelles des forages. La microgravimétrie en milieu urbain implique de corriger avec soin les perturbations gravifiques sur la mesure de la pesanteur dues aux effets de la topographie, des bâtiments et des caves afin d'isoler l'effet gravifique dû exclusivement à l'épaisseur du remplissage des terrains meubles. Tenant compte de l'intensité des corrections topographiques en milieu urbain, nous avons donné une grande importance aux sous-sols, leurs effets gravifiques pouvant atteindre l'ordre du dixième de mGal. Nous avons donc intégré ces corrections celle de topographie et traité les effets des bâtiments de manière indépendante. Nous avons inclus dans le modèle numérique de terrain (MNT) la chaussée et les sous-sols afin de construire un modèle numérique de terrain urbain. Nous utiliserons un nouvel acronyme « MNTU »pour décrire ce modèle. Nous proposons d'établir des cartes de corrections topographiques préalables, basées sur les données à disposition fournies par le cadastre en faisant des hypothèses sur la profondeur des sous-sols et la hauteur des bâtiments. Les deux zones de test choisies sont caractéristiques des différents types d'urbanisation présente à Lausanne et se révèlent par conséquent très intéressantes pour élaborer une méthodologie globale de la microgravimétrie urbaine. Le but était d'évaluer l'épaisseur du remplissage morainique sur un fond rocheux molassique se situant à une profondeur variable de quelques mètres à une trentaine de mètres et d'en établir une coupe dans l'axe du futur tracé du métro. Les résultats des modélisations se sont révélés très convaincants en détectant des zones qui diffèrent sensiblement du modèle géologique d'avant projet. Nous avons également démontré que l'application de cette méthode géophysique, non destructive, est à même de limiter le nombre de sondages mécaniques lors de l'avant-projet et du projet définitif, ce qui peut limiter à la fois les coûts et le dérangement engendré par ces travaux de surface. L'adaptabilité de la technique gravimétrique permet d'intervenir dans toutes les différentes phases d'un projet de génie civil comme celui de la construction d'un métro en souterrain. KURZFASSUNG Seit dem Frühling 2004 ist in der Stadt Lausanne (Schweiz) die neue U-Bahn "M2" in Konstruktion. Diese soll auf 6 km Länge die Lausanner Agglomeration von Süd nach Nord durchqueren. Die dem Projekt zu Grunde liegende technische Planung sieht vor, daß die Bahnlinie hauptsächlich in der Molasse angesiedelt sein wird. Seit dem Vorentwurf (1999) ist eine große Anzahl geologischer Angaben gesammelt worden. Daraus ergab sich die einmalige Gelegenheit, die Informationen aus den damit verbundenen zahlreichen Bohrungen zu einer detaillierten mikrogravimetrischen Studie der Stadt Lausanne zu erweitern und zu vervollständigen. Das Ziel bestand darin, die Mächtigkeit der die Molasseüberdeckenden Moräneablagerung abzuschätzen, um eine entsprechendes geologisches Profile entlang der künftigen Bahnlinie zu erstellen. Weiterhin sollte gezeigt werden, daß die Anwendung dieser nicht-invasiven geophysikalischen Methode es ermöglicht, die Anzahl der benötigten Bohrungen sowohl in der Pilotphase wie auch im endgültigen Projekt zu reduzieren, was zu wesentlichen finanziellen Einsparungen in der Ausführung des Werkes beitragen würde. Die beiden in dieser Studie bearbeiteten Testzonen befinden sich im Nordteil und im Stadtzentrum von Lausanne und sind durch eine unterschiedliche Urbanisierung charakterisiert. Das anstehende Gestein liegt in verschiedenen Tiefen: von einigen Metern bis zu etwa dreißig Metern. Diese Zonen weisen alle Schwierigkeiten einer urbanen Bebauung mit hoher Verkehrsdichte auf und waren daher massgebend bei der Ausarbeitung einer globalen mikrogravimetrischen Methodologie für die Stadt Lausanne. Die so entwickelte Technik ermöglicht, die störenden Auswirkungen der Topographie, der Gebäude, der Keller und der Öffentlichen Infrastrukturen sorgfältig zu korrigieren, um so die ausschließlich auf die Mächtigkeit des Lockergesteins zurückzuführenden Effekte zu isolieren. In Bezug auf die Intensität der Auswirkungen der topographischen Korrekturen im Stadtgebiet wurde den Untergeschossen eine besonders grosse Bedeutung zugemessen da die entsprechenden Schwerkrafteffekte eine Grösse von rund einem Zehntel mGal erreichen können. Wir schlagen deshalb vor, vorläufige Karten der topographischen Korrekturen zu erstellen. Diese Korrekturen basieren auf den uns vom Katasterplan gelieferten Daten und einigen Hypothesen bezüglich der Tiefe der Untergeschosse und der Höhe der Gebäude. Die Verfügbarkeit einer derartigen Karte vor der eigentlichen gravimetrischen Messkampagne würde uns erlauben, die Position der Meßstationen besser zu wählen. Wir sahen zudem, daß ein entsprechenden a priori Filter benutzt werden kann, wenn die Form und die Intensität der Anomalie offensichtlich dem entsprechenden Gebäude zugeordnet werden können. Diese Strategie muß jedoch mit Vorsicht angewandt werden, denn falls weitere Anomalien dazukommen, können bedeutende Verschiebungen durch Übèrlagerungen der Schwerewirkung verschiedener Strukturen entstehen. Die Ergebnisse der Modellierung haben sich als sehr überzeugend erwiesen, da sie im Voraus unbekannte sensible Zonen korrekt identifiziert haben. Die Anwendbarkeit der in dieser Arbeit entwickelten gravimetrischen Technik ermöglicht es, während allen Phasen eines Grossbauprojekts, wie zum Beispiel bei der Konstruktion einer unterirdischen U-Bahn, einzugreifen. ABSTRACT Since Spring of 2004 a new metro line has been under construction in the city of Lausanne in Switzerland. The new line, the M2, will be 6 km long and will traverse the city from south to north. The civil engineering project determined that the line would be located primarily in the Molasse. Since the preparatory project in 1999, a great quantity of geological data has been collected, and the many drillings made on the site have proved to be a unique opportunity to undertake a study of urban microgravimetry. The goal was to evaluate the thickness of the morainic filling over the molassic bedrock, and to establish a section along the axis of the future line. It then had to be shown that the application of this nondestructive geophysical method could reduce the number of mechanical surveys required both for a preparatory and a definitive project, which would lead to real savings in the realization of a civil engineering project. The two test zones chosen, one in the northern part of the city and one in the city centre, are characterised by various types of urbanisation. Bedrock is at a depth varying from a few metres to about thirty metres. These zones well exemplify the various difficulties encountered in an urban environment and are therefore very interesting for the development of an overall methodology of urban microgravimetry. Microgravimetry in an urban environment requires careful corrections for gravific disturbances due to the effects of topography, buildings, cellars, and the infrastructure of distribution networks, in order to isolate the gravific effect due exclusively to the thickness of loose soil filling. Bearing in mind the intensity of the topographic corrections in an urban environment, we gave particular importance to basements. Their gravific effects can reach the order of one tenth of one meal, and can influence above all the precision of the Bouguer anomaly. We propose to establish preliminary topographic correction charts based on data provided to us by the land register, by making assumptions on the depths of basements and the heights of buildings. Availability of this chart previous to a gravimetry campaign would enable us to choose optimum measuring sites. We have also seen that an a priori filter can be used when the form and the intensity of the anomaly correspond visually to the corresponding building. This strategy must be used with caution because if other anomalies are to be associated, important shifts can be generated by the superposition of the effects of different structures. The results of the model have proved to be very convincing in detecting previously unknown sensitive zones. The adaptability of the gravimetry technique allows for application in all phases of a civil engineering project such as the construction of an underground metro line. RIASSUNTO Dalla primavera 2004 una nuova linea metropolitana é in costruzione nella città di Losanna in Svizzera. La nuova metropolitana "M2" traverserà per la lunghezza di 6 km il centro urbano di Losanna da sud a nord. II progetto d'ingegneria civile prevedeva un tracciato situato essenzialmente nel fondo roccioso arenaceo terziario (molassa). Dalla redazione del progetto preliminare, avvenuta nel 1999, una grande quantità di dati geologici sono stati raccolti e sono stati eseguiti numerosi sondaggi. Questo sì é presentato come un'occasione unica per mettere a punto uno studio microgravimetrico in ambiente urbano con lo scopo di valutare lo spessore dei terreni sciolti di origine glaciale che ricoprono il fondo roccioso di molassa e di mettere in evidenza come l'applicazione di questo metodo geofisico non distruttivo possa limitare il numero di sondaggi meccanici nella fase di progetto preliminare ed esecutivo con conseguente reale risparmio economico nella realizzazione di una tale opera. Le due zone di test sono situate una nella zona nord e la seconda nel centro storico di Losanna e sono caratterizzate da stili architettonici differenti. II fondo roccioso é situato ad una profondità variabile da qualche metro ad una trentina. Queste due zone sembrano ben rappresentare tutte le difficoltà di un ambiente urbano e ben si prestano per elaborare una metodologia globale per la microgravimetria in ambiente urbano. L'applicazione di questa tecnica nell'ambiente suddetto implica la correzione attenta delle perturbazioni sulla misura dell'accelerazione gravitazionale, causate dalla topografia, gli edifici, le cantine e le infrastrutture dei sottoservizi, per ben isolare il segnale esclusivamente causato dallo spessore dei terreni sciolti. Tenuto conto, dell'intensità delle correzioni topografiche, abbiamo dato grande importanza alle cantine, poiché il loro effetto sulle misure può raggiungere il decimo di mGal. Proponiamo quindi di redigere una carta delle correzioni topografiche preliminare all'acquisizione, facendo delle ipotesi sulla profondità delle cantine e sull'altezza degli edifici, sulla base delle planimetrie catastali. L'analisi di questa carta permetterà di scegliere le posizioni più adatte per le stazioni gravimetriche. Abbiamo anche osservato che un filtro a priori, qualora la forma e l'intensità dell'anomalia fosse facilmente riconducibile in maniera visuale ad un edificio, possa essere efficace. Tuttavia questa strategia deve essere utilizzata con precauzione, poiché può introdurre uno scarto, qualora più anomalie, dovute a differenti strutture, si sovrappongano. I risultati delle modellizzazioni si sono rivelati convincenti, evidenziando zone sensibili non conosciute preventivamente. L'adattabilità della tecnica gravimetrica ha mostrato di poter intervenire in differenti fasi di un progetto di ingegneria civile, quale è quella di un'opera in sotterraneo.
Resumo:
Tässä diplomityössä tutkittiin sähkön laatua Suur-Savon Sähkön verkossa. Samalla perehdyttiin sähkönjakeluverkkojen aiheuttamiin ympäristövaikutuksiin ja näiden vähentämiseen. Työn aihealue on aika laaja kokonaisuus, eikä mihinkään perehdytä kovin yksityiskohtaisella tasolla, vaan käsitellään asiaa mahdollisimman laajasti monelta eri näkökantilta käytännönläheisesti. Mietittäessä keinoja parantaa sähkönlaatua alettiin yhtiössä pohtimaan keinoja vähentää 20 kV avojohtoverkon määrääja osana tätä keskustelua kehitettiin 1000 voltin jakelu-järjestelmä, jonka ensimmäiset koekohteet otettiin käyttöön vuonna 2001. Järjestelmä on osoittautunut käyttökelpoiseksi ja toimivaksi varsinkin vapaa-ajan asuntojen sähköistämisessä. Osana tulevaisuuden verkostostrategiaa joudutaan Suur-Savon Sähkössäkin pohtimaan maasulkuvirtojen kompensointia ja myös tätä aihealuetta onkäsitelty työn yhteydessä. Sähkön laatu on erittäin riippuvainen luonnon aiheuttamista vioista ja näiltä suojautuminen vaatii nykyisen avojohtoverkon korvaamista jollain muulla johtoratkaisulla, joka nostaa maasulkuvirran arvoa ja johtaa jossain vaiheessa kompensoinnin käyttöön.
Resumo:
The research of power-line communications has been concentrated on home automation, broadband indoor communications and broadband data transfer in a low voltage distribution network between home andtransformer station. There has not been carried out much research work that is focused on the high frequency characteristics of industrial low voltage distribution networks. The industrial low voltage distribution network may be utilised as a communication channel to data transfer required by the on-line condition monitoring of electric motors. The advantage of using power-line data transfer is that it does not require the installing of new cables. In the first part of this work, the characteristics of industrial low voltage distribution network components and the pilot distribution network are measured and modelled with respect topower-line communications frequencies up to 30 MHz. The distributed inductances, capacitances and attenuation of MCMK type low voltage power cables are measured in the frequency band 100 kHz - 30 MHz and an attenuation formula for the cables is formed based on the measurements. The input impedances of electric motors (15-250 kW) are measured using several signal couplings and measurement based input impedance model for electric motor with a slotted stator is formed. The model is designed for the frequency band 10 kHz - 30 MHz. Next, the effect of DC (direct current) voltage link inverter on power line data transfer is briefly analysed. Finally, a pilot distribution network is formed and signal attenuation in communication channels in the pilot environment is measured. The results are compared with the simulations that are carried out utilising the developed models and measured parameters for cables and motors. In the second part of this work, a narrowband power-line data transfer system is developed for the data transfer ofon-line condition monitoring of electric motors. It is developed using standardintegrated circuits. The system is tested in the pilot environment and the applicability of the system for the data transfer required by the on-line condition monitoring of electric motors is analysed.
Resumo:
For the first time in Finland, the chemical profiling of cocaine specimens was performed at the National Bureau of Investigation (NBI). The main goals were to determine the chemical composition of cocaine specimens sold in the Finnish market and to study the distribution networks of cocaine in order to provide intelligence related to its trafficking. An analytical methodology enabling through one single GC-MS injection the determination of the added cutting agents (adulterants and diluents), the cocaine purity and the chemical profile (based on the major and minor alkaloids) for each specimen was thus implemented and validated. The methodology was found to be efficient for the discrimination between specimens coming from the same source and specimens coming from different sources. The results highlighted the practical utility of the chemical profiling, especially for supporting the investigation through operational intelligence and improving the knowledge related to the cocaine trafficking through strategic intelligence.
Resumo:
Actualmente vuelve a ser viable la organización mediante turnos de redes de distribución de riego a presión gracias al desarrollo de sistemas de automáticos de telegestión. La organización por turnos supone una disminución de los caudales en la red y el consiguiente ahorro económico. En la comunicación se presentan diversas expresiones sencillas para calcular la disminución relativa de caudales conseguida mediante la organización por turnos respecto a la demanda. Dicha disminución depende del número de hidrantes abastecidos por un tramo y de la probabilidad de que los hidrantes estén abiertos. Se ha contrastado los resultados de las expresiones propuestas con datos de proyecto y se consiguen buenos ajustes. El ahorro económico obtenido con la organización por turnos respecto a la demanda se puede estimar entre un 26 y un 49 % el ahorro medio de caudales.
Resumo:
Sähkönjakeluverkkojen kehittäminen nykyistä käyttövarmemmiksi ja taloudellisemmiksi vaatii jatkuvasti uusia ratkaisumalleja. Lupaavaksi tekniikaksi sähkönjakeluverkkojen kehittämisessä on osoittautumassa tasasähkönjakelu tehoelektronisten komponenttien kehittyessä ja hintojen laskiessa samanaikaisesti. Pienjännitedirektiivi mahdollistaa tasajännitteen myötä aiempaa suurempien jännitteiden käytön pienjänniteverkoissa. Tasajännitteen käytöllä voidaan saavuttaa etuja mm. tehonsiirtokyvyssä, sähkönlaadussa, käyttövarmuudessa sekä kustannuksissa. Työssä tehdään yksityiskohtaisia teknistaloudellisia tarkasteluja perinteistä 20/0,4 kV tekniikkaa, 1000 V sähkönjakelua sekä tasasähköjärjestelmiä hyödyntäen ja verrataan näiden järjestelmien kustannuksia ja ominaisuuksia toisiinsa. Tutkimusalueet on valittu Fortum Sähkönsiirto Oy:n maaseutu- ja taajamaverkoista. Työssä pyritään hahmotta-maan teknistaloudellista käyttöaluetta eri tasasähkönjakelujärjestelmille sekä määrittä-mään tasasähkönjakelun käyttöpotentiaali tutkimuskohteena olleissa verkoissa. Lisäksi tutkitaan eri tekijöiden vaikutuksia tasasähköjakelun kannattavuuteen ja käyttövarmuu-teen sekä pyritään tuomaan esiin muitakin tasasähkönjakelujärjestelmien ominaisuuksia.
Resumo:
Sähkönsiirto jakeluverkoissa on alueellista monopoliliiketoimintaa. Tätä monopoliliiketoimintaa säätelee Suomessa energiamarkkinavirasto. Siirtoliiketoiminnalle on asetettu kohtuullisen tuoton rajoitukset siten, että liiketoiminnan täytyy olla myös tehokkaasti toteutettua. Sähköverkkojen ylläpitopalveluiden toteuttamiseksi on markkinoille syntynyt useita näiden palveluiden tuottamiseen erikoistuneita palveluyrityksiä. Ulkoistamalla ylläpitopalvelut ulkopuoliselle palveluyritykselle sähköverkkoyhtiöt pyrkivät hakemaan toiminnalleen tehokkuutta, kustannussäästöjä ja toimintojen selkeytymistä. Yhtiön johto voi näin keskittyä toiminnan ja tuloksen kehittämisen kannalta olennaisiin asioihin. Tässä työssä on selvitetty sähköverkkojen ylläpitotoimintojen ulkoistamisella saavutettavissa olevia hyötyjä. Hyötyjen toteutumista on tutkittu Eltel Networks Pohjoinen Oy:n ja sen asiakasyritysten Kainuun Sähkö Oyj:n, Kajaanin Lämpö Oy:n ja Kajaanin Puhelinosuuskunnan asiakastapauksissa.
Resumo:
Tässä työssä tutkitaan haja-asutusalueiden sähkönjakeluverkkojen kehittämistä. Kehityskohteiksi on valittu viisi tekniikkaa, 1000 V-järjestelmä, keskijännitejohtojen siirtäminen teiden varsille, PAS -johtojen käyttö, maakaapelointi sekä pylväskatkaisijan käyttö. Teoreettisen tarkastelun tavoitteena on määrittää reunaehdot tarkasteltavien tekniikoiden kannattavuudelle. Aiemmin keskijänniteverkko on rakennettu lähes poikkeuksetta avojohtona. Viime vuosien myrskyt sekä lumikuormat ovat häirinneet sähkönjakelua ja nostaneet painetta jakeluvarmuuden kasvattamiseksi. Tutkimuksessa haja-asutusalueiden sähkönjakeluverkon kehittämiseen etsitään teknillisesti sekä taloudellisesti kannattavia ratkaisumalleja. Kehittämisen tavoitteena on parantaa kuluttajien sähkön laatua ja toimitusvarmuutta. Tutkimuksessa käsitellään tarkasteltavia tekniikoita esimerkkikohteiden avulla, jotka on valittu Itä-Suomelle tyypillisiltä jakelualueilta. Kohteissa taloudellista kannattavuutta tutkitaan vertaamalla perinteistä saneeraamista tarkastelussa oleviin korvaaviin menetelmiin. Korvaavilla ratkaisuilla toimitusvarmuus paranee, mutta kannattavuus riippuu siirrettävästä tehosta, asiakasryhmien jakaumasta sekä saavutettavasta vikataajuuden muutoksesta.
Resumo:
Tässä työssä tutkitaan 1000 V pienjännitejakelun taloudellista kannattavuutta. Tutkimus perustuu teoreettiseen tarkasteluun, jossa noudatetaan yleisiä verkostosuunnittelun periaatteita. EU-lainsäädäntö mahdollistaa 1000 V pienjänniteportaan sijoittamisen nykyisen keskijänniteverkon ja pienjänniteverkon väliin lisäten kolmannen jakelujänniteportaan nykyään käytettävien 20 kV ja 0,4 kV väliin. Jakeluverkkojen kehittämiseksi on etsittävä ratkaisu, joka on taloudellinen sekä asiakkaiden että verkonhaltijoiden kannalta. Tällaiset ratkaisut pienentävät verkon käytön kokonaiskustannuksia ja parantavat sähkön laatua. Lisättäessä jakeluverkkoon kolmas jänniteporras, keskijänniteverkon johtopituus lyhenee ja varsinkin lyhyiden haarajohtojen määrä vähenee. Tämä vähentää keskijänniteverkossa esiintyvien keskeytysten määrää ja pienentää keskeytyskustannuksia. Kilovoltin järjestelmä on kannattava korvattaessa sillä osa keskijänniteverkkoa, tai estettäessä perinteisellä järjestelmällä tarvittava muuntopiirin jakaminen. Osana varsinaista pienjänniteverkkoa ei kilovoltinjärjestelmä ole kannattava. Tässä työssä kolmijänniteportaista jakeluverkkoa tutkitaan teoreettisilla verkkosuunnitelmilla, joita tehdään muutamille perusverkkotopologioille. Taloudellista kannattavuutta tutkitaan vertaamalla perinteistä kaksijänniteportaista ja kolmijänniteportaista verkkoratkaisua kustannusten suhteen teknisten reunaehtojen puitteissa. 1000 V pienjännitejakelu vaatii uudenlaisia verkostokomponentteja. Näistä on erityisesti käsitelty 1/0,4 kV pienjännitemuuntajaa. Muuntajasuunnittelun lähtökohtana on 1000 V verkon käyttäminen keskijänniteverkon jatkeena maasta erotettuna verkkona.
Resumo:
This work analyses the medium voltage network in central built-up area of Savonlinna city, evaluates the future standards of the electricity distribution network and presents methods for the network renovation. Main challenge is to find a working topology and network solutions for the transitional phase of the renovation progress. The network renovation methods are verified with an example solution for an existing suburban area of Savonlinna City, wherein the medium voltage and small voltage distribution networks are renovated.