933 resultados para condition monitoring system


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Between the years 1992 and 1995 about 3.5 million hadronic Z decays were collected by the DELPHI detector at CERN. This data has been used to measure the production and lifetime of the beauty strange baryon Ξb, in the inclusive decay channel Ξb →Ξ-ℓ- X. The Ξ- baryon was reconstructed through the decay Ξ- → Λ π-, using a constrained fit method for cascade decays. An iterative discriminant analysis was used for the Ξb selection. A search for the Ξb baryon was also performed using an alternative method of reconstructing the Ξ- baryon. A measurement of the production of the charmed strange baryon Ξc in the decay channel Ξc → Ξ-π+ using the same data is also presented. The radiation monitoring system of the Silicon Microstrip Tracker in the DØ detector is studied and used to estimate the radiation dose received by the Silicon detector during normal running conditions of the TeVatron accelerator.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

SMARTDIAB is a platform designed to support the monitoring, management, and treatment of patients with type 1 diabetes mellitus (T1DM), by combining state-of-the-art approaches in the fields of database (DB) technologies, communications, simulation algorithms, and data mining. SMARTDIAB consists mainly of two units: 1) the patient unit (PU); and 2) the patient management unit (PMU), which communicate with each other for data exchange. The PMU can be accessed by the PU through the internet using devices, such as PCs/laptops with direct internet access or mobile phones via a Wi-Fi/General Packet Radio Service access network. The PU consists of an insulin pump for subcutaneous insulin infusion to the patient and a continuous glucose measurement system. The aforementioned devices running a user-friendly application gather patient's related information and transmit it to the PMU. The PMU consists of a diabetes data management system (DDMS), a decision support system (DSS) that provides risk assessment for long-term diabetes complications, and an insulin infusion advisory system (IIAS), which reside on a Web server. The DDMS can be accessed from both medical personnel and patients, with appropriate security access rights and front-end interfaces. The DDMS, apart from being used for data storage/retrieval, provides also advanced tools for the intelligent processing of the patient's data, supporting the physician in decision making, regarding the patient's treatment. The IIAS is used to close the loop between the insulin pump and the continuous glucose monitoring system, by providing the pump with the appropriate insulin infusion rate in order to keep the patient's glucose levels within predefined limits. The pilot version of the SMARTDIAB has already been implemented, while the platform's evaluation in clinical environment is being in progress.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The goal of this study was to analyze the mode of inheritance of an overweight body condition in an experimental cat population. The cat population consisted of 95 cats of which 81 cats could be clearly classified into lean or overweight using the body condition scoring system according to Laflamme. The lean or overweight classification was then used for segregation analyses. Complex segregation analyses were employed to test for the significance of one environmental and 4 genetic models (general, mixed inheritance, major gene, and polygene). The general genetic model fit the data significantly better than the environmental model (P

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Stets darauf bedacht, die Anlagen- und Maschinenverfügbarkeit bei möglichst geringem Ressourceneinsatz zu gewährleisten, wird die Rolle der Instandhaltung als unternehmerischer Wertschöpfungsfaktor immer bedeutsamer. Voraussetzung für eine Nutzbarmachung bestehender Potentiale sind neue Werkzeuge und Ansätze, deren Umsetzung eine effiziente Sicherstellung von Verfügbarkeit ermöglicht. Vor diesem Hintergrund wurde im Teilprojekt C3 des DFG Paketantrags 672 ein Konzept zur nutzungsabhängigen Instandhaltung entwickelt. Auf Grundlage des bestehenden Zusammenhangs von Nutzung und Abnutzung risikobehafteter Bauteile intralogistischer Systeme können damit die durch zukünftige Systemlasten hervorgerufenen Beanspruchungen antizipiert werden. Instandhaltungsmaßnahmen und technische Verfügbarkeiten werden dadurch anforderungsgerecht und ressourcen-optimal planbar.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In this work, we provide a passive location monitoring system for IEEE 802.15.4 signal emitters. The system adopts software defined radio techniques to passively overhear IEEE 802.15.4 packets and to extract power information from baseband signals. In our system, we provide a new model based on the nonlinear regression for ranging. After obtaining distance information, a Weighted Centroid (WC) algorithm is adopted to locate users. In WC, each weight is inversely proportional to the nth power of propagation distance, and the degree n is obtained from some initial measurements. We evaluate our system in a 16m-18m area with complex indoor propagation conditions. We are able to achieve a median error of 2:1m with only 4 anchor nodes.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The potential effects of climatic changes on natural risks are widely discussed. But the formulation of strategies for adapting risk management practice to climate changes requires knowledge of the related risks for people and economic values. The main goals of this work were (1) the development of a method for analysing and comparing risks induced by different natural hazard types, (2) highlighting the most relevant natural hazard processes and related damages, (3) the development of an information system for the monitoring of the temporal development of natural hazard risk and (4) the visualisation of the resulting information for the wider public. A comparative exposure analysis provides the basis for pointing out the hot spots of natural hazard risks in the province of Carinthia, Austria. An analysis of flood risks in all municipalities provides the basis for setting the priorities in the planning of flood protection measures. The methods form the basis for a monitoring system that periodically observes the temporal development of natural hazard risks. This makes it possible firstly to identify situations in which natural hazard risks are rising and secondly to differentiate between the most relevant factors responsible for the increasing risks. The factors that most influence the natural risks could be made evident.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Considering the measurement procedures recommended by the ICNIRP, this communication is a proposal for a measurement procedure based in the maximum peak values of equivalent plane wave power density. This procedure has been included in a project being developed in Leganés, Spain. The project plans to deploy a real time monitoring system for RF to provide the city with a useful tool to adapt the environmental EM conditions to the new regulations approved. A first stage consisting of 105 measurement points has been finished and all the values are under the threshold of the regulation.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Geodetic volcano monitoring in Tenerife has mainly focused on the Las Cañadas Caldera, where a geodetic micronetwork and a levelling profile are located. A sensitivity test of this geodetic network showed that it should be extended to cover the whole island for volcano monitoring purposes. Furthermore, InSAR allowed detecting two unexpected movements that were beyond the scope of the traditional geodetic network. These two facts prompted us to design and observe a GPS network covering the whole of Tenerife that was monitored in August 2000. The results obtained were accurate to one centimetre, and confirm one of the deformations, although they were not definitive enough to confirm the second one. Furthermore, new cases of possible subsidence have been detected in areas where InSAR could not be used to measure deformation due to low coherence. A first modelling attempt has been made using a very simple model and its results seem to indicate that the deformation observed and the groundwater level variation in the island may be related. Future observations will be necessary for further validation and to study the time evolution of the displacements, carry out interpretation work using different types of data (gravity, gases, etc) and develop models that represent the island more closely. The results obtained are important because they might affect the geodetic volcano monitoring on the island, which will only be really useful if it is capable of distinguishing between displacements that might be linked to volcanic activity and those produced by other causes. One important result in this work is that a new geodetic monitoring system based on two complementary techniques, InSAR and GPS, has been set up on Tenerife island. This the first time that the whole surface of any of the volcanic Canary Islands has been covered with a single network for this purpose. This research has displayed the need for further similar studies in the Canary Islands, at least on the islands which pose a greater risk of volcanic reactivation, such as Lanzarote and La Palma, where InSAR techniques have been used already.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Here an inertial sensor-based monitoring system for measuring and analyzing upper limb movements is presented. The final goal is the integration of this motion-tracking device within a portable rehabilitation system for brain injury patients. A set of four inertial sensors mounted on a special garment worn by the patient provides the quaternions representing the patient upper limb’s orientation in space. A kinematic model is built to estimate 3D upper limb motion for accurate therapeutic evaluation. The human upper limb is represented as a kinematic chain of rigid bodies with three joints and six degrees of freedom. Validation of the system has been performed by co-registration of movements with a commercial optoelectronic tracking system. Successful results are shown that exhibit a high correlation among signals provided by both devices and obtained at the Institut Guttmann Neurorehabilitation Hospital.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

La temperatura es una preocupación que juega un papel protagonista en el diseño de circuitos integrados modernos. El importante aumento de las densidades de potencia que conllevan las últimas generaciones tecnológicas ha producido la aparición de gradientes térmicos y puntos calientes durante el funcionamiento normal de los chips. La temperatura tiene un impacto negativo en varios parámetros del circuito integrado como el retardo de las puertas, los gastos de disipación de calor, la fiabilidad, el consumo de energía, etc. Con el fin de luchar contra estos efectos nocivos, la técnicas de gestión dinámica de la temperatura (DTM) adaptan el comportamiento del chip en función en la información que proporciona un sistema de monitorización que mide en tiempo de ejecución la información térmica de la superficie del dado. El campo de la monitorización de la temperatura en el chip ha llamado la atención de la comunidad científica en los últimos años y es el objeto de estudio de esta tesis. Esta tesis aborda la temática de control de la temperatura en el chip desde diferentes perspectivas y niveles, ofreciendo soluciones a algunos de los temas más importantes. Los niveles físico y circuital se cubren con el diseño y la caracterización de dos nuevos sensores de temperatura especialmente diseñados para los propósitos de las técnicas DTM. El primer sensor está basado en un mecanismo que obtiene un pulso de anchura variable dependiente de la relación de las corrientes de fuga con la temperatura. De manera resumida, se carga un nodo del circuito y posteriormente se deja flotando de tal manera que se descarga a través de las corrientes de fugas de un transistor; el tiempo de descarga del nodo es la anchura del pulso. Dado que la anchura del pulso muestra una dependencia exponencial con la temperatura, la conversión a una palabra digital se realiza por medio de un contador logarítmico que realiza tanto la conversión tiempo a digital como la linealización de la salida. La estructura resultante de esta combinación de elementos se implementa en una tecnología de 0,35 _m. El sensor ocupa un área muy reducida, 10.250 nm2, y consume muy poca energía, 1.05-65.5nW a 5 muestras/s, estas cifras superaron todos los trabajos previos en el momento en que se publicó por primera vez y en el momento de la publicación de esta tesis, superan a todas las implementaciones anteriores fabricadas en el mismo nodo tecnológico. En cuanto a la precisión, el sensor ofrece una buena linealidad, incluso sin calibrar; se obtiene un error 3_ de 1,97oC, adecuado para tratar con las aplicaciones de DTM. Como se ha explicado, el sensor es completamente compatible con los procesos de fabricación CMOS, este hecho, junto con sus valores reducidos de área y consumo, lo hacen especialmente adecuado para la integración en un sistema de monitorización de DTM con un conjunto de monitores empotrados distribuidos a través del chip. Las crecientes incertidumbres de proceso asociadas a los últimos nodos tecnológicos comprometen las características de linealidad de nuestra primera propuesta de sensor. Con el objetivo de superar estos problemas, proponemos una nueva técnica para obtener la temperatura. La nueva técnica también está basada en las dependencias térmicas de las corrientes de fuga que se utilizan para descargar un nodo flotante. La novedad es que ahora la medida viene dada por el cociente de dos medidas diferentes, en una de las cuales se altera una característica del transistor de descarga |la tensión de puerta. Este cociente resulta ser muy robusto frente a variaciones de proceso y, además, la linealidad obtenida cumple ampliamente los requisitos impuestos por las políticas DTM |error 3_ de 1,17oC considerando variaciones del proceso y calibrando en dos puntos. La implementación de la parte sensora de esta nueva técnica implica varias consideraciones de diseño, tales como la generación de una referencia de tensión independiente de variaciones de proceso, que se analizan en profundidad en la tesis. Para la conversión tiempo-a-digital, se emplea la misma estructura de digitalización que en el primer sensor. Para la implementación física de la parte de digitalización, se ha construido una biblioteca de células estándar completamente nueva orientada a la reducción de área y consumo. El sensor resultante de la unión de todos los bloques se caracteriza por una energía por muestra ultra baja (48-640 pJ) y un área diminuta de 0,0016 mm2, esta cifra mejora todos los trabajos previos. Para probar esta afirmación, se realiza una comparación exhaustiva con más de 40 propuestas de sensores en la literatura científica. Subiendo el nivel de abstracción al sistema, la tercera contribución se centra en el modelado de un sistema de monitorización que consiste de un conjunto de sensores distribuidos por la superficie del chip. Todos los trabajos anteriores de la literatura tienen como objetivo maximizar la precisión del sistema con el mínimo número de monitores. Como novedad, en nuestra propuesta se introducen nuevos parámetros de calidad aparte del número de sensores, también se considera el consumo de energía, la frecuencia de muestreo, los costes de interconexión y la posibilidad de elegir diferentes tipos de monitores. El modelo se introduce en un algoritmo de recocido simulado que recibe la información térmica de un sistema, sus propiedades físicas, limitaciones de área, potencia e interconexión y una colección de tipos de monitor; el algoritmo proporciona el tipo seleccionado de monitor, el número de monitores, su posición y la velocidad de muestreo _optima. Para probar la validez del algoritmo, se presentan varios casos de estudio para el procesador Alpha 21364 considerando distintas restricciones. En comparación con otros trabajos previos en la literatura, el modelo que aquí se presenta es el más completo. Finalmente, la última contribución se dirige al nivel de red, partiendo de un conjunto de monitores de temperatura de posiciones conocidas, nos concentramos en resolver el problema de la conexión de los sensores de una forma eficiente en área y consumo. Nuestra primera propuesta en este campo es la introducción de un nuevo nivel en la jerarquía de interconexión, el nivel de trillado (o threshing en inglés), entre los monitores y los buses tradicionales de periféricos. En este nuevo nivel se aplica selectividad de datos para reducir la cantidad de información que se envía al controlador central. La idea detrás de este nuevo nivel es que en este tipo de redes la mayoría de los datos es inútil, porque desde el punto de vista del controlador sólo una pequeña cantidad de datos |normalmente sólo los valores extremos| es de interés. Para cubrir el nuevo nivel, proponemos una red de monitorización mono-conexión que se basa en un esquema de señalización en el dominio de tiempo. Este esquema reduce significativamente tanto la actividad de conmutación sobre la conexión como el consumo de energía de la red. Otra ventaja de este esquema es que los datos de los monitores llegan directamente ordenados al controlador. Si este tipo de señalización se aplica a sensores que realizan conversión tiempo-a-digital, se puede obtener compartición de recursos de digitalización tanto en tiempo como en espacio, lo que supone un importante ahorro de área y consumo. Finalmente, se presentan dos prototipos de sistemas de monitorización completos que de manera significativa superan la características de trabajos anteriores en términos de área y, especialmente, consumo de energía. Abstract Temperature is a first class design concern in modern integrated circuits. The important increase in power densities associated to recent technology evolutions has lead to the apparition of thermal gradients and hot spots during run time operation. Temperature impacts several circuit parameters such as speed, cooling budgets, reliability, power consumption, etc. In order to fight against these negative effects, dynamic thermal management (DTM) techniques adapt the behavior of the chip relying on the information of a monitoring system that provides run-time thermal information of the die surface. The field of on-chip temperature monitoring has drawn the attention of the scientific community in the recent years and is the object of study of this thesis. This thesis approaches the matter of on-chip temperature monitoring from different perspectives and levels, providing solutions to some of the most important issues. The physical and circuital levels are covered with the design and characterization of two novel temperature sensors specially tailored for DTM purposes. The first sensor is based upon a mechanism that obtains a pulse with a varying width based on the variations of the leakage currents on the temperature. In a nutshell, a circuit node is charged and subsequently left floating so that it discharges away through the subthreshold currents of a transistor; the time the node takes to discharge is the width of the pulse. Since the width of the pulse displays an exponential dependence on the temperature, the conversion into a digital word is realized by means of a logarithmic counter that performs both the timeto- digital conversion and the linearization of the output. The structure resulting from this combination of elements is implemented in a 0.35_m technology and is characterized by very reduced area, 10250 nm2, and power consumption, 1.05-65.5 nW at 5 samples/s, these figures outperformed all previous works by the time it was first published and still, by the time of the publication of this thesis, they outnumber all previous implementations in the same technology node. Concerning the accuracy, the sensor exhibits good linearity, even without calibration it displays a 3_ error of 1.97oC, appropriate to deal with DTM applications. As explained, the sensor is completely compatible with standard CMOS processes, this fact, along with its tiny area and power overhead, makes it specially suitable for the integration in a DTM monitoring system with a collection of on-chip monitors distributed across the chip. The exacerbated process fluctuations carried along with recent technology nodes jeop-ardize the linearity characteristics of the first sensor. In order to overcome these problems, a new temperature inferring technique is proposed. In this case, we also rely on the thermal dependencies of leakage currents that are used to discharge a floating node, but now, the result comes from the ratio of two different measures, in one of which we alter a characteristic of the discharging transistor |the gate voltage. This ratio proves to be very robust against process variations and displays a more than suficient linearity on the temperature |1.17oC 3_ error considering process variations and performing two-point calibration. The implementation of the sensing part based on this new technique implies several issues, such as the generation of process variations independent voltage reference, that are analyzed in depth in the thesis. In order to perform the time-to-digital conversion, we employ the same digitization structure the former sensor used. A completely new standard cell library targeting low area and power overhead is built from scratch to implement the digitization part. Putting all the pieces together, we achieve a complete sensor system that is characterized by ultra low energy per conversion of 48-640pJ and area of 0.0016mm2, this figure outperforms all previous works. To prove this statement, we perform a thorough comparison with over 40 works from the scientific literature. Moving up to the system level, the third contribution is centered on the modeling of a monitoring system consisting of set of thermal sensors distributed across the chip. All previous works from the literature target maximizing the accuracy of the system with the minimum number of monitors. In contrast, we introduce new metrics of quality apart form just the number of sensors; we consider the power consumption, the sampling frequency, the possibility to consider different types of monitors and the interconnection costs. The model is introduced in a simulated annealing algorithm that receives the thermal information of a system, its physical properties, area, power and interconnection constraints and a collection of monitor types; the algorithm yields the selected type of monitor, the number of monitors, their position and the optimum sampling rate. We test the algorithm with the Alpha 21364 processor under several constraint configurations to prove its validity. When compared to other previous works in the literature, the modeling presented here is the most complete. Finally, the last contribution targets the networking level, given an allocated set of temperature monitors, we focused on solving the problem of connecting them in an efficient way from the area and power perspectives. Our first proposal in this area is the introduction of a new interconnection hierarchy level, the threshing level, in between the monitors and the traditional peripheral buses that applies data selectivity to reduce the amount of information that is sent to the central controller. The idea behind this new level is that in this kind of networks most data are useless because from the controller viewpoint just a small amount of data |normally extreme values| is of interest. To cover the new interconnection level, we propose a single-wire monitoring network based on a time-domain signaling scheme that significantly reduces both the switching activity over the wire and the power consumption of the network. This scheme codes the information in the time domain and allows a straightforward obtention of an ordered list of values from the maximum to the minimum. If the scheme is applied to monitors that employ TDC, digitization resource sharing is achieved, producing an important saving in area and power consumption. Two prototypes of complete monitoring systems are presented, they significantly overcome previous works in terms of area and, specially, power consumption.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper presents a multi-stage algorithm for the dynamic condition monitoring of a gear. The algorithm provides information referred to the gear status (fault or normal condition) and estimates the mesh stiffness per shaft revolution in case that any abnormality is detected. In the first stage, the analysis of coefficients generated through discrete wavelet transformation (DWT) is proposed as a fault detection and localization tool. The second stage consists in establishing the mesh stiffness reduction associated with local failures by applying a supervised learning mode and coupled with analytical models. To do this, a multi-layer perceptron neural network has been configured using as input features statistical parameters sensitive to torsional stiffness decrease and derived from wavelet transforms of the response signal. The proposed method is applied to the gear condition monitoring and results show that it can update the mesh dynamic properties of the gear on line.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Upper limb function impairment is one of the most common sequelae of central nervous system injury, especially in stroke patients and when spinal cord injury produces tetraplegia. Conventional assessment methods cannot provide objective evaluation of patient performance and the tiveness of therapies. The most common assessment tools are based on rating scales, which are inefficient when measuring small changes and can yield subjective bias. In this study, we designed an inertial sensor-based monitoring system composed of five sensors to measure and analyze the complex movements of the upper limbs, which are common in activities of daily living. We developed a kinematic model with nine degrees of freedom to analyze upper limb and head movements in three dimensions. This system was then validated using a commercial optoelectronic system. These findings suggest that an inertial sensor-based motion tracking system can be used in patients who have upper limb impairment through data integration with a virtual reality-based neuroretation system.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Hoy en día asistimos a un creciente interés por parte de la sociedad hacia el cuidado de la salud. Esta afirmación viene apoyada por dos realidades. Por una parte, el aumento de las prácticas saludables (actividad deportiva, cuidado de la alimentación, etc.). De igual manera, el auge de los dispositivos inteligentes (relojes, móviles o pulseras) capaces de medir distintos parámetros físicos como el pulso cardíaco, el ritmo respiratorio, la distancia recorrida, las calorías consumidas, etc. Combinando ambos factores (interés por el estado de salud y disponibilidad comercial de dispositivos inteligentes) están surgiendo multitud de aplicaciones capaces no solo de controlar el estado actual de salud, también de recomendar al usuario cambios de hábitos que lleven hacia una mejora en su condición física. En este contexto, los llamados dispositivos llevables (weareables) unidos al paradigma de Internet de las cosas (IoT, del inglés Internet of Things) permiten la aparición de nuevos nichos de mercado para aplicaciones que no solo se centran en la mejora de la condición física, ya que van más allá proponiendo soluciones para el cuidado de pacientes enfermos, la vigilancia de niños o ancianos, la defensa y la seguridad, la monitorización de agentes de riesgo (como bomberos o policías) y un largo etcétera de aplicaciones por llegar. El paradigma de IoT se puede desarrollar basándose en las existentes redes de sensores inalámbricos (WSN, del inglés Wireless Sensor Network). La conexión de los ya mencionados dispositivos llevables a estas redes puede facilitar la transición de nuevos usuarios hacia aplicaciones IoT. Pero uno de los problemas intrínsecos a estas redes es su heterogeneidad. En efecto, existen multitud de sistemas operativos, protocolos de comunicación, plataformas de desarrollo, soluciones propietarias, etc. El principal objetivo de esta tesis es realizar aportaciones significativas para solucionar no solo el problema de la heterogeneidad, sino también de dotar de mecanismos de seguridad suficientes para salvaguardad la integridad de los datos intercambiados en este tipo de aplicaciones. Algo de suma importancia ya que los datos médicos y biométricos de los usuarios están protegidos por leyes nacionales y comunitarias. Para lograr dichos objetivos, se comenzó con la realización de un completo estudio del estado del arte en tecnologías relacionadas con el marco de investigación (plataformas y estándares para WSNs e IoT, plataformas de implementación distribuidas, dispositivos llevables y sistemas operativos y lenguajes de programación). Este estudio sirvió para tomar decisiones de diseño fundamentadas en las tres contribuciones principales de esta tesis: un bus de servicios para dispositivos llevables (WDSB, Wearable Device Service Bus) basado en tecnologías ya existentes tales como ESB, WWBAN, WSN e IoT); un protocolo de comunicaciones inter-dominio para dispositivos llevables (WIDP, Wearable Inter-Domain communication Protocol) que integra en una misma solución protocolos capaces de ser implementados en dispositivos de bajas capacidades (como lo son los dispositivos llevables y los que forman parte de WSNs); y finalmente, la tercera contribución relevante es una propuesta de seguridad para WSN basada en la aplicación de dominios de confianza. Aunque las contribuciones aquí recogidas son de aplicación genérica, para su validación se utilizó un escenario concreto de aplicación: una solución para control de parámetros físicos en entornos deportivos, desarrollada dentro del proyecto europeo de investigación “LifeWear”. En este escenario se desplegaron todos los elementos necesarios para validar las contribuciones principales de esta tesis y, además, se realizó una aplicación para dispositivos móviles por parte de uno de los socios del proyecto (lo que contribuyó con una validación externa de la solución). En este escenario se usaron dispositivos llevables tales como un reloj inteligente, un teléfono móvil con sistema operativo Android y un medidor del ritmo cardíaco inalámbrico capaz de obtener distintos parámetros fisiológicos del deportista. Sobre este escenario se realizaron diversas pruebas de validación mediante las cuales se obtuvieron resultados satisfactorios. ABSTRACT Nowadays, society is shifting towards a growing interest and concern on health care. This phenomenon can be acknowledged by two facts: first, the increasing number of people practising some kind of healthy activity (sports, balanced diet, etc.). Secondly, the growing number of commercial wearable smart devices (smartwatches or bands) able to measure physiological parameters such as heart rate, breathing rate, distance or consumed calories. A large number of applications combining both facts are appearing. These applications are not only able to monitor the health status of the user, but also to provide recommendations about routines in order to improve the mentioned health status. In this context, wearable devices merged with the Internet of Things (IoT) paradigm enable the proliferation of new market segments for these health wearablebased applications. Furthermore, these applications can provide solutions for the elderly or baby care, in-hospital or in-home patient monitoring, security and defence fields or an unforeseen number of future applications. The introduced IoT paradigm can be developed with the usage of existing Wireless Sensor Networks (WSNs) by connecting the novel wearable devices to them. In this way, the migration of new users and actors to the IoT environment will be eased. However, a major issue appears in this environment: heterogeneity. In fact, there is a large number of operating systems, hardware platforms, communication and application protocols or programming languages, each of them with unique features. The main objective of this thesis is defining and implementing a solution for the intelligent service management in wearable and ubiquitous devices so as to solve the heterogeneity issues that are presented when dealing with interoperability and interconnectivity of devices and software of different nature. Additionally, a security schema based on trust domains is proposed as a solution to the privacy problems arising when private data (e.g., biomedical parameters or user identification) is broadcasted in a wireless network. The proposal has been made after a comprehensive state-of-the-art analysis, and includes the design of a Wearable Device Service Bus (WDSB) including the technologies collected in the requirement analysis (ESB, WWBAN, WSN and IoT). Applications are able to access the WSN services regardless of the platform and operating system where they are running. Besides, this proposal also includes the design of a Wearable Inter-Domain communication Protocols set (WIDP) which integrates lightweight protocols suitable to be used in low-capacities devices (REST, JSON, AMQP, CoAP, etc...). Furthermore, a security solution for service management based on a trustworthy domains model to deploy security services in WSNs has been designed. Although the proposal is a generic framework for applications based on services provided by wearable devices, an application scenario for testing purposes has been included. In this validation scenario it has been presented an autonomous physical condition performance system, based on a WSN, bringing the possibility to include several elements in an IoT scenario: a smartwatch, a physiological monitoring device and a smartphone. In summary, the general objective of this thesis is solving the heterogeneity and security challenges arising when developing applications for WSNs and wearable devices. As it has been presented in the thesis, the solution proposed has been successfully validated in a real scenario and the obtained results were satisfactory.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In this paper the model of an Innovative Monitoring Network involving properly connected nodes to develop an Information and Communication Technology (ICT) solution for preventive maintenance of historical centres from early warnings is proposed. It is well known that the protection of historical centres generally goes from a large-scale monitoring to a local one and it could be supported by a unique ICT solution. More in detail, the models of a virtually organized monitoring system could enable the implementation of automated analyses by presenting various alert levels. An adequate ICT solution tool would allow to define a monitoring network for a shared processing of data and results. Thus, a possible retrofit solution could be planned for pilot cases shared among the nodes of the network on the basis of a suitable procedure utilizing a retrofit catalogue. The final objective would consist in providing a model of an innovative tool to identify hazards, damages and possible retrofit solutions for historical centres, assuring an easy early warning support for stakeholders. The action could proactively target the needs and requirements of users, such as decision makers responsible for damage mitigation and safeguarding of cultural heritage assets.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper presents an overview of the role and responsibilities of the system administrator, focusing on the need to monitor its technological infrastructure. The informatics infrastructure monitoring is, nowadays without a doubt, one of the main key points in business support. Large enterprises are no longer the only ones to feel the need to use these monitoring tools, but small and medium-sized enterprises, which also have IT environments of an increasing complexity, feel such a need. This results directly from the operation of how the business is supported on IT platforms as support for people and processes. When a system, which is vital to the organization, fails either at the hardware or software level, compromises the operating capacity and consequently the business continuity. Having this always in mind, it is extremely important to adopt monitoring systems that proactively or reactively, reduce the overall time of breaks caused by failures. A monitoring system is the way to ensure confidence in all components and the operational readiness of IT infrastructure.