975 resultados para charge-coupled device image sensor


Relevância:

30.00% 30.00%

Publicador:

Resumo:

An assay for the simultaneous analysis of pharmaceutical compounds and their metabolites from micro-whole blood samples (i.e. 5 microL) was developed using an on-line dried blood spot (on-line DBS) device coupled with hydrophilic interaction/reversed-phase (HILIC/RP) LC/MS/MS. Filter paper is directly integrated to the LC device using a homemade inox desorption cell. Without any sample pretreatment, analytes are desorbed from the paper towards an automated system of valves linking a zwitterionic-HILIC column to an RP C18 column. In the same run, the polar fraction is separated by the zwitterionic-HILIC column while the non-polar fraction is eluted on the RP C18. Both fractions are detected by IT-MS operating in full scan mode for the survey scan and in product ion mode for the dependant scan using an ESI source. The procedure was evaluated by the simultaneous qualitative analysis of four probes and their relative phase I and II metabolites spiked in whole blood. In addition, the method was successfully applied to the in vivo monitoring of buprenorphine metabolism after the administration of an intraperitoneal injection of 30 mg/kg on adult female Wistar rat.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction : La prise en charge des patients critiques nécessite dans la majorité des situations l'obtention rapide d'un accès vasculaire, afin d'administrer des médicaments, des solutés de remplissage, ou des produits sanguins. La mise en place d'un accès vasculaire peut s'avérer difficile chez ces patients. En cas d'échec de pose d'une voie veineuse périphérique, des abords vasculaires alternatifs existent. Il s'agit essentiellement de la pose d'une voie veineuse centrale, la réalisation d'une dénudation veineuse, ou la pose d'une voie intra-osseuse. Depuis le développement de dispositifs d'insertion « semi-automatique » à la fin des années 90, la voie intra-osseuse, traditionnellement réservée aux cas pédiatriques, est de plus en plus fréquemment utilisée chez les patients adultes. Le Service des Urgences du CHUV a introduit en 2009 les dispositifs d'insertion d'aiguilles intra-osseuses de type EZ-IO® (perceuse électrique), en salle de réanimation des urgences vitales (déchoquage), ainsi qu'au sein du secteur préhospitalier pour les interventions du SMUR de Lausanne et de l'hélicoptère REGA de la base de Lausanne. Par cette étude, nous voulions mettre en évidence les aspects épidémiologiques des patients ayant dû être perfusés par cet abord dans un contexte préhospitalier, ainsi que les circonstances cliniques ayant justifié un tel usage, le taux de succès, les éventuelles complications, les médicaments perfusés et la mortalité des patients ayant bénéficié de ce dispositif. Méthode: Chaque patient ayant bénéficié de la mise en place d'une voie intra-osseuse par EZ-IO® du 1er janvier 2009 au 31 décembre 2011 a été inclus. Les données récoltées étaient l'âge, le sexe, l'indication à la mise en place de l'intra-osseuse, la localisation, le taux de succès, les médicaments et fluides administrés, les complications, la mortalité à 48 heures et à la sortie de l'hôpital. Tous les articles mentionnant l'utilisation de ΙΈΖ-ΙΟ® dans des situations cliniques ont également été analysés par une revue de littérature structurée exhaustive, afin de comparer nos résultats avec les données de la littérature. Résultats : Cinquante-huit patients, représentant 60 intra-osseuses EZ-IO®, ont été inclus. Leur âge moyen (47 ans), le taux de succès (90%), les indications, la localisation de l'aiguille (98% au niveau du tibia proximal) et le taux de complications (0%) correspondent aux valeurs trouvées dans la littérature. Le taux de survie de nos patients est de 38% à 48 heures et de 29% à la sortie de l'hôpital. De nombreux médicaments ou solutés de perfusion ont été administrés; l'adrénaline restant le médicament le plus fréquemment administré par cette voie. Dans 7 cas, les patients ont bénéficié d'une induction d'anesthésie par voie intra-osseuse. La revue de littérature a permis de compiler 30 études distinctes, représentant un total de 1603 accès vasculaires de type EZ-IO®. Conclusion : La voie intra-osseuse s'avère fiable et rapide pour obtenir un accès vasculaire, avec un taux de complications très faible et permet l'administration d'un grand nombre de substances. D'autres études sont nécessaires pour évaluer l'impact de la voie intra osseuse, notamment en termes de mortalité, de complications tardives, ainsi que d'analyse coût/bénéfice de ce matériel.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract:The objective of this work was to evaluate whether a canopy sensor is capable of estimating sugarcane response to N, as well as to propose strategies for handling the data generated by this device during the decision-making process for crop N fertilization. Four N rate-response experiments were carried out, with N rates varying from 0 to 240 kg ha-1. Two evaluations with the canopy sensor were performed when the plants reached average stalk height of 0.3 and 0.5 m. Only two experiments showed stalk yield response to N rates. The canopy sensor was able to identify the crop response to different N rates and the relationship of the nutrient with sugarcane yield. The response index values obtained from the canopy sensor readings were useful in assessing sugarcane response to the applied N rate. Canopy reflectance sensors can help to identify areas responsive to N fertilization and, therefore, improve sugarcane fertilizer management.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, the sensor of an optical mouse is presented as a counterfeit coin detector applied to the two-Euro case. The detection process is based on the short distance image acquisition capabilities of the optical mouse sensor where partial images of the coin under analysis are compared with some partial reference coin images for matching. Results show that, using only the vision sense, the counterfeit acceptance and rejection rates are very similar to those of a trained user and better than those of an untrained user.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

La déchirure des ischio-jambiers est la blessure non-traumatique la plus fréquemment rencontrée dans les sports demandant une course à haute vitesse. Les ischio-jambiers sont particulièrement vulnérables lors de la fin de phase d'oscillation du sprint étant donné qu'ils se contractent excentriquement alors qu'ils sont en position d'allongement. Le renforcement excentrique a été montré comme étant une méthode efficace pour diminuer le risque de blessure. Cependant, les exercices classiquement utilisés comme le Nordic hamstring ne soumettent pas les ischio-jambiers à un niveau d'allongement spécifique au sprint. Dès lors, l'objectif de cette thèse était d'évaluer le fonctionnement des ischio-jambiers à différents niveaux d'allongement musculo- tendineux puis de transposer dans la pratique les résultats obtenus afin de concevoir des exercices plus spécifiques aux besoins des athlètes. Avant cela, une première partie avait pour but de proposer de nouvelles méthodes d'évaluation de terrain des ischio-jambiers. Les différents travaux réalisés pour cette thèse ont permis : 1) de proposer deux nouveaux outils de terrain pour l'évaluation de la flexibilité et de la force des ischio-jambiers ; 2) de montrer que le niveau d'allongement influence directement la force produite par les ischio-jambiers et de suggérer que ce niveau d'allongement semble être un stimulus au moins aussi déterminant que le mode de contraction musculaire pour générer des adaptations de l'architecture musculaire propices à la diminution du risque de blessure ; 3) de proposer des modalités spécifiques de renforcement des ischio-jambiers destinées aux sprinteurs dans une perspective de prévention des blessures et de montrer l'efficacité de ces recommandations sur l'amélioration d'un certain nombre de facteurs de risque de blessure. Finalement, ce travail a ouvert de nouvelles perspectives allant de la proposition d'exercices de renforcement de terrain au développement d'un système motorisé spécifique au sprint permettant le renforcement et l'évaluation de la force des ischio-jambiers en passant par différents projets de recherche. -- High-speed running sports accounts for the majority of hamstring strains. The terminal swing phase of the running cycle is believed to be the most hazardous as the hamstrings are undergoing an active lengthening contraction in a long muscle length position. Prevention-based strength training relies mainly on eccentric exercises. However, most hamstrings exercises like the Nordic hamstring are performed at an inadequately low hip-flexion angle. Thus, the objective of this thesis was to assess the hamstring function at different muscle lengths and depending on the obtained results to design strength exercises more specific to the athlete's need. Before that, a first part of this thesis aimed to develop new assessment methods of the hamstring on site. The different studies included in the present thesis allowed: 1) to propose two new methods to test the hamstring flexibility and strength on the field; 2) to show that the hamstring muscle length directly influences its level of strength, and to suggest that the training range of motion could be a dominant stimulus (as important than contraction type) for modifying the muscle architecture, which leads to a decrease in hamstring injury risk; 3) to define sprint specific parameters for prevention-based strength training, and to show the efficiency of these recommendations on the improvement of several injury risk factors for the hamstring. Finally, this thesis proposed new perspectives: 1) new strength exercises on site; 2) the development of a motorised device specific for the sprint which could be used to strength and to assess the hamstring; 3) several future research projects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Because of their unique capacity to cross-present Ags to CD8(+) T cells, mouse lymphoid tissue-resident CD8(+) dendritic cells (DCs) and their migratory counterparts are critical for priming antiviral T cell responses. High expression of the dsRNA sensor TLR3 is a distinctive feature of these cross-presenting DC subsets. TLR3 engagement in CD8(+) DCs promotes cross-presentation and the acquisition of effector functions required for driving antiviral T cell responses. In this study, we performed a comprehensive analysis of the TLR3-induced antiviral program and cell-autonomous immunity in CD8(+) DC lines and primary CD8(+) DCs. We found that TLR3-ligand polyinosinic-polycytidylic acid and human rhinovirus infection induced a potent antiviral protection against Sendai and vesicular stomatitis virus in a TLR3 and type I IFN receptor-dependent manner. Polyinosinic-polycytidylic acid-induced antiviral genes were identified by mass spectrometry-based proteomics and transcriptomics in the CD8(+) DC line. Nanostring nCounter experiments confirmed that these antiviral genes were induced by TLR3 engagement in primary CD8(+) DCs, and indicated that many are secondary TLR3-response genes requiring autocrine IFN-β stimulation. TLR3-activation thus establishes a type I IFN-dependent antiviral program in a DC subtype playing crucial roles in priming adaptive antiviral immune responses. This mechanism is likely to shield the priming of antiviral responses against inhibition or abrogation by the viral infection. It could be particularly relevant for viruses detected mainly by TLR3, which may not trigger type I IFN production by DCs that lack TLR3, such as plasmacytoid DCs or CD8(-) DCs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

L'abcès pulmonaire se présente de manière très pléomorphe selon les germes initialement impliqués. Des symptômes gé­ néraux et une évolution souvent subaiguë sont retrouvés en cas d'aspiration de la flore oropharyngée, chez des patients avec des troubles de l'état de conscience ou de la déglutition. L'infection est très souvent polymicrobienne, avec présence de germes anaérobes dans deux tiers des cas. La prise en charge consiste en un traitement antibiotique prolongé, jusqu'à résolution ou stabilité de l'image radiologique. En cas d'état toxique ou d'absence de drainage bronchique spontané, un drainage de l'abcès est à discuter. Les sanctions chirurgicales sont peu souvent nécessaires et envisagées indépendamment de la taille de l'abcès excepté lors de néoplasie sous-jacente. Lung abscess occurs in very pleomorphic according to germs initially involved. The mechanism commonly found is an aspiration of the oropharyngeal flora in patients with disorders of consciousness or swallowing. The infection is polymicrobial, with presence of anaerobic germs in 2/3 of the cases. The support consists of a prolonged antibiotic treatment, as well as anaerobic until resolution or stability of the radiological image. In case of prolonged toxic state, drainage of the abscess is to be discussed especially if there is no airways drainage. Surgical sanctions is rarely needed regardless of the size of the abscess, unless underlying carcinoma is present.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aquest projecte s’emmarca dins de l’àmbit de la visió per computador, concretament en la utilització de dades de profunditat obtingudes a través d’un emissor i sensor de llum infraroja.El propòsit principal d’aquest projecte és mostrar com adaptar aquestes tecnologies, a l’abast de qualsevol particular, de forma que un usuari durant la pràctica d’una activitat esportiva concreta, rebi informació visual continua dels moviments i gestos incorrectes que està realitzant, en base a uns paràmetres prèviament establerts.L’objectiu d’aquest projecte consisteix en fer una lectura constant en temps real d’una persona practicant una selecció de diverses activitats esportives estàtiques utilitzant un sensor Kinect. A través de les dades obtingudes pel sensor Kinect i utilitzant les llibreries de “skeleton traking” proporcionades per Microsoft s’haurà d’interpretar les dades posturals obtingudes per cada tipus d’esport i indicar visualment i d’una manera intuïtiva els errors que està cometent en temps real, de manera que es vegi clarament a quina part del seu cos realitza un moviment incorrecte per tal de poder corregir-lo ràpidament. El entorn de desenvolupament que s’utilitza per desenvolupar aquesta aplicació es Microsoft Viusal Studio 2010.El llenguatge amb el qual es treballarà sobre Microsoft Visual Studio 2010 és C#

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report the use of an optical fiber sensor to measure the soybean oil concentration in samples obtained from the mixture of pure biodiesel and commercial soybean oil. The operation of the device is based on the long-period grating sensitivity to the surrounding medium refractive index, which leads to measurable modifications in the grating transmission spectrum. The proposed analysis method results in errors in the oil concentration of 0.4% and 2.6% for pure biodiesel and commercial soybean oil, respectively. Techniques of total glycerol, dynamic viscosity, density, and hydrogen nuclear magnetic resonance spectroscopy were also employed to validate the proposed method.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

El reconeixement dels gestos de la mà (HGR, Hand Gesture Recognition) és actualment un camp important de recerca degut a la varietat de situacions en les quals és necessari comunicar-se mitjançant signes, com pot ser la comunicació entre persones que utilitzen la llengua de signes i les que no. En aquest projecte es presenta un mètode de reconeixement de gestos de la mà a temps real utilitzant el sensor Kinect per Microsoft Xbox, implementat en un entorn Linux (Ubuntu) amb llenguatge de programació Python i utilitzant la llibreria de visió artifical OpenCV per a processar les dades sobre un ordinador portàtil convencional. Gràcies a la capacitat del sensor Kinect de capturar dades de profunditat d’una escena es poden determinar les posicions i trajectòries dels objectes en 3 dimensions, el que implica poder realitzar una anàlisi complerta a temps real d’una imatge o d’una seqüencia d’imatges. El procediment de reconeixement que es planteja es basa en la segmentació de la imatge per poder treballar únicament amb la mà, en la detecció dels contorns, per després obtenir l’envolupant convexa i els defectes convexos, que finalment han de servir per determinar el nombre de dits i concloure en la interpretació del gest; el resultat final és la transcripció del seu significat en una finestra que serveix d’interfície amb l’interlocutor. L’aplicació permet reconèixer els números del 0 al 5, ja que s’analitza únicament una mà, alguns gestos populars i algunes de les lletres de l’alfabet dactilològic de la llengua de signes catalana. El projecte és doncs, la porta d’entrada al camp del reconeixement de gestos i la base d’un futur sistema de reconeixement de la llengua de signes capaç de transcriure tant els signes dinàmics com l’alfabet dactilològic.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this communication we describe the application of a conductive polymer gas sensor as an air pressure sensor. The device consists of a thin doped poly(4'-hexyloxy-2,5-biphenylene ethylene) (PHBPE) film deposited on an interdigitated metallic electrode. The sensor is cheap, easy to fabricate, lasts for several months, and is suitable for measuring air pressures in the range between 100 and 700 mmHg.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This technical note describes the construction of a low-cost optical detector. This device is composed by a high-sensitive linear light sensor (model ILX554) and a microcontroller. The performance of the detector was demonstrated by the detection of emission and Raman spectra of the several atomic systems and the results reproduce those found in the literature.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Diplomityön tavoitteena oli kehittää Wipak Oy:n valmistamille sterilointipakkauksille tulevaisuuden pakkauskonsepti. Sterilointipakkaukset luokitellaan lääkelaitedirektiivin mukaan lisätarvikkeiksi luokan 1 lääkelaitteille, ja tämä näkökulma oli vahvasti mukana konseptin kehityksessä. Lähtökohtana pakkauskonseptin suunnittelulle oli tuotteiden arvoketjussa, eli pakata tuotteet siten että pakkausten avulla voidaan tuottaa lisäarvoa arvoketjun toimijoille. Tavoitteena oli parantaa pakkausten viestintää, toimivuutta/tehokkuutta toimitusketjussa sekä vahvistaa brändin imagoa myynti- ja kuljetuspakkauksen avulla. Lääkinnälliset laitteet ja tarvikkeet ovat lainsäädännön ja normien avulla tarkasti säädeltyjä. Näiden normien vaatimukset asettavat perusteet myynti- ja kuljetuspakkausten kehittämiselle. Tämän lisäksi suunnittelussa on huomioitu asiakkaiden toiveet ja kehitystarpeet. Kirjallisuusosuudessa on keskitytty lääkinnällisten laitteiden pakkausyksiköiden toimintoihin sekä niiden kehitysnäkymiin. Pääpaino on ollut pakkausmerkintöjen ja jäljitettävyyden kehittämisellä, koska tietojen automaattisen tunnistuksen hyödyntäminen lääkintälaitteiden pakkausten arvoketjussa on kasvava trendi. Manuaalisesti tehtävät tuotevirtojen kirjaukset ketjun eri toimijoiden osalta lisäävät riskejä jäljitettävyyden kannalta ja aiheuttavat lisätyötä ja – kustannuksia ketjun kaikille osapuolille. Ehdotus uudesta pakkauskonseptista on kehitetty näiden tietojen pohjalta. Ehdotuksessa on huomioitu lainsäädännöstä ja ketjun toimijoilta tulevat tarpeet, sekä alan tulevaisuuden kehitysnäkymät. Ehdotetun pakkauskonseptin avulla saadaan lisättyä myynti- ja kuljetuspakkausten tehokkuutta, parannettua jäljitettävyyttä ja helpotettu arvoketjun alavirran toimijoiden työtä lisäämällä erillinen sisäpakkaus myyntiyksikön sisälle. Työssä on lisäksi selvitetty pakkauskonseptin kustannusvaikutukset tuotteiden hintaan. Lopussa on ehdotettu jatkotoimenpiteet suunnitelman implementoimisesta käytäntöön.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of the present paper is to study the relationship between the fracture modes in hydrogen-assisted cracking (HAC) in microalloied steel and the emission of acoustic signals during the fracturing process. For this reason, a flux-cored arc weld (FCAW) was used in a high-strength low-alloy steel. The consumable used were the commercially available AWS E120T5-K4 and had a diameter of 1.6 mm. Two different shielding gases were used (CO2 and CO2+5% H2) to obtain complete phenomenon characterization. The implant test was applied with three levels of restriction stresses. An acoustic emission measurement system (AEMS) was coupled to the implant test apparatus. The output signal from the acoustic emission sensor was passed through an electronic amplifier and processed by a root mean square (RMS) voltage converter. Fracture surfaces were examined by scanning electron microscopy (SEM) and image analysis. Fracture modes were related with the intensity, the energy and the number of the peaks of the acoustic emission signal. The shielding gas CO2+5% H2 proved to be very useful in the experiments. Basically, three different fracture modes were identified in terms of fracture appearance: microvoid coalescence (MVC), intergranular (IG) and quasi-cleavage (QC). The results show that each mode of fracture presents a characteristic acoustic signal.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work, image based estimation methods, also known as direct methods, are studied which avoid feature extraction and matching completely. Cost functions use raw pixels as measurements and the goal is to produce precise 3D pose and structure estimates. The cost functions presented minimize the sensor error, because measurements are not transformed or modified. In photometric camera pose estimation, 3D rotation and translation parameters are estimated by minimizing a sequence of image based cost functions, which are non-linear due to perspective projection and lens distortion. In image based structure refinement, on the other hand, 3D structure is refined using a number of additional views and an image based cost metric. Image based estimation methods are particularly useful in conditions where the Lambertian assumption holds, and the 3D points have constant color despite viewing angle. The goal is to improve image based estimation methods, and to produce computationally efficient methods which can be accomodated into real-time applications. The developed image-based 3D pose and structure estimation methods are finally demonstrated in practise in indoor 3D reconstruction use, and in a live augmented reality application.