964 resultados para bromine and iodine determination


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work introduces two novel approaches for the application of luminescence dating techniques to Quaternary volcanic eruptions: crystalline xenoliths from lava flows are demonstrated to be basically suitable for luminescence dating, and a set of phreatic explosion deposits from the Late Quaternary Vakinankaratra volcanic field in central Madagascar is successfully dated with infrared stimulated luminescence (IRSL). Using a numerical model approach and experimental verification, the potential for thermal resetting of luminescence signals of xenoliths in lava flows is demonstrated. As microdosimetry is an important aspect when using sample material extracted from crystalline whole rocks, autoradiography using image plates is introduced to the field of luminescence dating as a method for detection and assessment of spatially resolved radiation inhomogeneities. Determinations of fading rates of feldspar samples have been observed to result in aberrant g-values if the pause between preheat and measurement in the delayed measurements was kept short. A systematic investigation reveals that the phenomenon is caused by the presence of three signal components with differing individual fading behaviour. As this is restricted to short pauses, it is possible to determine a minimal required delay between preheating and measurement after which the aberrant behaviour disappears. This is applied in the measuring of 12 samples from phreatic explosion deposits from the Antsirabe – Betafo region in the Late Quaternary Vakinankaratra volcanic field. The samples were taken from stratigraphically correlatable sections and appear to represent at least three phreatic events, one of which created the Lac Andraikiba maar near Antsirabe. The obtained ages indicate that the eruptive activity in the region started in the Late Pleistocene between 113.9 and 99.6 ka. A second layer in the Betafo area is dated at approximately 73 ka and the Lac Andraikiba deposits give an age between 63.9 and 50.7 ka. The youngest phreatic layer is dated between 33.7 and 20.7 ka. These ages are the first recorded direct ages of such volcanic deposits, as well as the first and only direct ages for the Late Quaternary volcanism in the Vakinankaratra volcanic field. This illustrates the huge potential of this new method for volcanology and geochronology, as it enables direct numerical dating of a type of volcanic deposit which has not been successfully directly dated by any other method so far.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Activated carbon was prepared from date pits via chemical activation with H3PO4. The effects of activating agent concentration and activation temperature on the yield and surface area were studied. The optimal activated carbon was prepared at 450 °C using 55 % H3PO4. The prepared activated carbon was characterized by Fourier transform infrared spectroscopy, scanning electron microscopy, thermogravimetric-differential thermal analysis, and Brunauer, Emmett, and Teller (BET) surface area. The prepared date pit-based activated carbon (DAC) was used for the removal of bromate (BrO3 −). The concentration of BrO3 − was determined by ultra-performance liquid chromatography-mass tandem spectrometry (UPLC-MS/MS). The experimental equilibrium data for BrO3 − adsorption onto DAC was well fitted to the Langmuir isotherm model and showed maximum monolayer adsorption capacity of 25.64 mg g−1. The adsorption kinetics of BrO3 − adsorption was very well represented by the pseudo-first-order equation. The analytical application of DAC for the analysis of real water samples was studied with very promising results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The establishment of the most stable structures of eight membered rings is a challenging task to the field of conformational analysis. In this work, a series of 2-halocyclooctanones were synthesized (including fluorine, chlorine, bromine and iodine derivatives) and submitted to conformational studies using a combination of theoretical calculation and infrared spectroscopy. For each compound, four conformations were identified as the most important ones. These conformations are derived from the chair-boat conformation of cyclooctanone. The pseudo-equatorial (with respect to the halogen) conformer is preferred in vacuum and in low polarity solvents for chlorine, bromine and iodine derivatives. For 2-fluorocyclooctanone, the preferred conformation in vacuum is pseudo-axial. In acetonitrile, the pseudo-axial conformer becomes the most stable for the chlorine derivative. According to NBO calculations, the conformational preference is not dictated by electron delocalization, but by classical electrostatic repulsions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Le fullerène C60 est une molécule sphérique composée exclusivement d'atomes de carbone. Ce composé possède une surface aromatique convexe homogène et peut s'associer, entre autres, avec des molécules possédant des surfaces aromatiques par des interactions non-covalentes. Le triptycène est une molécule en forme de "Y" qui possède des surfaces aromatiques convexes. Cette molécule possède l'habileté de s'associer avec le C60 par des interactions de type π qui sont amplifiées par la complémentarité des surfaces concaves et convexes impliquées dans les arrangements cristallins. Nous avons synthétisé des dérivés triptycényles portant des groupements fonctionnels aux extrémités des bras de ce noyau de façon à étendre les cavités disponibles pour interagir avec le C60. En effet, nous avons découvert que les atomes de chlore, de brome et d'iode ainsi que les groupements méthyle permettent d'étendre les surfaces disponibles pour interagir avec les fullerènes C60 et C70. Nous avons étudié les associations entre les dérivés triptycényles et les fullerènes par l'analyse des structures cristallographiques résolues par diffraction des rayons-X. De plus, nous avons étudié les associations entre les molécules considérées par l'analyse des surfaces d'Hirshfeld entourant les fullerènes. Découlant de ces études, l'effet d'amplification des atomes de chlore, de brome et d'iode ainsi que les groupements méthyle a été employé pour identifier de nouveaux solvants aptes à solubiliser efficacement le C60.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Die qualitative und quantitative Analyse von Biomolekülen hat in den letzten Jahren und Jahrzehnten immer mehr an Bedeutung gewonnen. Durch das Aufkommen und die kontinuierliche Weiterentwicklung neuer Separations- und Detektionsmethoden und deren Verbindung miteinander zu leistungsfähigen Einheiten, erlangte man Schritt für Schritt neue Erkenntnisse bei ihrer Untersuchung. Die Elementmassenspektrometrie als nachweisstarke Detektionsmethode wird von vielen wissenschaftlichen Arbeitsgruppen bei der Trennung und Quantifizierung von Proteinen und Metalloproteinen mittels Detektion der in den Biomolekülen vorkommenden Metalle und Heteroatome angewendet. Heteroatome (z.B. Schwefel, Phosphor) haben im Plasma des ICP-MS (inductively coupled plasma - mass spectrometer) schlechte Ionisationseigenschaften und dementsprechend deutlich höhere Nachweisgrenzen als Metalle. Ein Ansatz, schlecht oder nicht detektierbare Verbindungen (also solche, die keine Metalle oder Heteroatome enthalten) mit dem ICP-MS sichtbar zu machen, ist die Markierung der selbigen mit Metallionen oder -cluster. rnIn dieser Arbeit ist es gelungen, der Analyse ganz unterschiedlicher Substanzklassen, zum einen metallische Nanopartikel und zum anderen Proteine, neue Impulse zu geben und zukünftiges Potential bei der Anwendung gekoppelter Techniken zur Separation und Detektion aufzuzeigen. Durch die Verwendung einer alten, aber neu konzipierten Trenntechnik, der Gelelektrophorese (GE), und deren Kopplung an einen modernen Detektor, dem ICP-MS, kann die für die Proteinanalytik weit verbreitete Gelelektrophorese ihr enormes Potential bei der Trennung verschiedenster Verbindungsklassen mit der exzellenten Nachweisstärke und Elementspezifität des ICP-MS verbinden und dadurch mit deutlich weniger Arbeitsaufwand als bisher qualitative und auch quantitative Ergebnisse produzieren. Bisher war dies nur mit großem präparativem Aufwand unter Verwendung der laser ablation möglich. Bei der Analyse von Nanopartikeln konnte aufgezeigt werden, dass durch die GE-ICP-MS-Kopplung aufgrund der guten Trenneigenschaften der GE vorhandene Spezies bzw. Fraktionen voneinander separiert werden und mit Hilfe des ICP-MS Informationen auf atomarem Niveau gewonnen werden können. Es war möglich, das atomare Verhältnis der Metallatome im Kern und der Schwefelatome in der Ligandenhülle eines Nanopartikels zu bestimmen und damit die Größe des Partikels abzuschätzen. Auch konnte die Anzahl der Goldatome in einem dem Schmid-Cluster ähnlichen Nanopartikel bestimmt werden, was vorher nur mit Hilfe von MALDI-TOF möglich war. Bei der Analyse von Biomolekülen konnte auf einfache Weise der Phosphorylierungsgrad verschiedener Proteine bestimmt werden. Auch bei kleinen Molekülen erzielt die Gelelektrophorese ausgezeichnete Trennergebnisse, wie z. B. bei der Analyse verschiedener Brom- und Iodspezies.rnDie stöchiometrische Kopplung eines Proteins an einen Nanopartikel, ohne eine der beiden Verbindungen in einem größeren Maße zu verändern, stellte jedoch eine Herausforderung dar, die im Rahmen dieser Arbeit nicht vollständig gelöst werden konnte. Verschiedene Ansätze zur Kopplung der beiden Substanzen wurden erprobt, jedoch führte keine zu dem gewünschten Ergebnis einer stöchiometrisch vollständigen und spezifischen Modifikation eines Proteins mit einem Nanopartikel. Durch das Potential der GE-ICP-MS-Kopplung bei der Analyse beider Substanz-klassen und dem Beweis der Praktikabilität und Zuverlässigkeit der Methode ist jedoch der Grundstein für weitere Forschungen auf diesem Gebiet gelegt worden. Ist eine geeignete chemische Kopplung der beiden Substanzklassen gefunden und beherrscht, steht auf analytischer Seite eine leistungsstarke Kombination aus Trennung und Detektion zur Verfügung, um die Quantifizierung von Proteinen entscheidend zu verbessern.rn

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two sensitive spectrophotometric methods are described for the determination of lansoprazole (LPZ) in bulk drug and in capsule formulation. The methods are based on the oxidation of lansoprazole by insitu generated bromine followed by determination of unreacted bromine by two different reaction schemes. In one procedure (method A), the residual bromine is treated with excess of iron (II), and the resulting iron (III) is complexed with thiocyanate and measured at 470 nm. The second approach (method B) involves treating the unreacted bromine with a measured excess of iron (II) and remaining iron (II) is complexed with orthophenanthroline at a raised pH, and measured at 510 nm. In both methods, the amount of bromine reacted corresponds to the amount of LPZ. The experimental conditions were optimized. In method A, the absorbance is found to decrease linearly with the concentration of LPZ (r = -0.9986) where as in the method B a linear increase in absorbance occurs (r = 0.9986) The systems obey Beer's law for 0.5-4.0 and 0.5-6.0 µg mL-1 for method A and method B, respectively. The calculated molar absorptivity values are 3.97µ10(4) and 3.07µ10(4) L mol-1cm-1 for method A and method B, respectively, and the corresponding Sandell sensitivity values are 0.0039 and 0.0013 µg cm-2. The limit of detection (LOD) and quantification (LOQ) are also reported for both methods. Intra-day and inter-day precision, and accuracy of the methods were established as per the current ICH guidelines. The methods were successfully applied to the determination of LPZ in capsules and the results tallied well with the label claim and the results were statistically compared with those of a reference method by applying the Student's t-test and F-test. No interference was observed from the concomitant substances normally added to capsules. The accuracy and validity of the methods were further ascertained by performing recovery experiments via standard-addition method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It has been demonstrated that iodine does have an important influence on atmospheric chemistry, especially the formation of new particles and the enrichment of iodine in marine aerosols. It was pointed out that the most probable chemical species involved in the production or growth of these particles are iodine oxides, produced photochemically from biogenic halocarbon emissions and/or iodine emission from the sea surface. However, the iodine chemistry from gaseous to particulate phase in the coastal atmosphere and the chemical nature of the condensing iodine species are still not understood. A Tenax / Carbotrap adsorption sampling technique and a thermo-desorption / cryo-trap / GC-MS system has been further developed and improved for the volatile organic iodine species in the gas phase. Several iodo-hydrocarbons such as CH3I, C2H5I, CH2ICl, CH2IBr and CH2I2 etc., have been measured in samples from a calibration test gas source (standards), real air samples and samples from seaweeds / macro-algae emission experiments. A denuder sampling technique has been developed to characterise potential precursor compounds of coastal particle formation processes, such as molecular iodine in the gas phase. Starch, TMAH (TetraMethylAmmonium Hydroxide) and TBAH (TetraButylAmmonium Hydroxide) coated denuders were tested for their efficiencies to collect I2 at the inner surface, followed by a TMAH extraction and ICP/MS determination, adding tellurium as an internal standard. The developed method has been proved to be an effective, accurate and suitable process for I2 measurement in the field, with the estimated detection limit of ~0.10 ng∙L-1 for a sampling volume of 15 L. An H2O/TMAH-Extraction-ICP/MS method has been developed for the accurate and sensitive determination of iodine species in tropospheric aerosol particles. The particle samples were collected on cellulose-nitrate filters using conventional filter holders or on cellulose nitrate/tedlar-foils using a 5-stage Berner impactor for size-segregated particle analysis. The water soluble species as IO3- and I- were separated by anion exchanging process after water extraction. Non-water soluble species including iodine oxide and organic iodine were digested and extracted by TMAH. Afterwards the triple samples were analysed by ICP/MS. The detection limit for particulate iodine was determined to be 0.10~0.20 ng•m-3 for sampling volumes of 40~100 m3. The developed methods have been used in two field measurements in May 2002 and September 2003, at and around the Mace Head Atmospheric Research Station (MHARS) located at the west coast of Ireland. Elemental iodine as a precursor of the iodine chemistry in the coastal atmosphere, was determined in the gas phase at a seaweed hot-spot around the MHARS, showing I2 concentrations were in the range of 0~1.6 ng∙L-1 and indicating a positive correlation with the ozone concentration. A seaweed-chamber experiment performed at the field measurement station showed that the I2 emission rate from macro-algae was in the range of 0.019~0.022 ng•min-1•kg-1. During these experiments, nanometer-particle concentrations were obtained from the Scanning Mobility Particle Sizer (SMPS) measurements. Particle number concentrations were found to have a linear correlation with elemental iodine in the gas phase of the seaweeds chamber, showing that gaseous I2 is one of the important precursors of the new particle formation in the coastal atmosphere. Iodine contents in the particle phase were measured in both field campaigns at and around the field measurement station. Total iodine concentrations were found to be in the range of 1.0 ~ 21.0 ng∙m-3 in the PM2.5 samples. A significant correlation between the total iodine concentrations and the nanometer-particle number concentrations was observed. The particulate iodine species analysis indicated that iodide contents are usually higher than those of iodate in all samples, with ratios in the range of 2~5:1. It is possible that those water soluble iodine species are transferred through the sea-air interface into the particle phase. The ratio of water soluble (iodate + iodide) and non-water soluble species (probably iodine oxide and organic iodine compounds) was observed to be in the range of 1:1 to 1:2. It appears that higher concentrated non-water soluble species, as the products of the photolysis from the gas phase into the particle phase, can be obtained in those samples while the nucleation events occur. That supports the idea that iodine chemistry in the coastal boundary layer is linked with new particle formation events. Furthermore, artificial aerosol particles were formed from gaseous iodine sources (e.g. CH2I2) using a laboratory reaction-chamber experiment, in which the reaction constant of the CH2I2 photolysis was calculated to be based upon the first order reaction kinetic. The end products of iodine chemistry in the particle phase were identified and quantified.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A flow injection (FI) micelle-mediated separation/preconcentration procedure for the determination of lead and cadmium by flame atomic absorption spectrometry (FAAS) has been proposed. The analytes reacted with 1-(2-thiazolylazo)-2-naphthol (TAN) to form hydrophobic chelates, which were extracted into the micelles of 0.05% (w/v) Triton X-114 in a solution buffered at pH 8.4. In the preconcentration stage, the micellar solution was continuously injected into a flow system with four mini-columns packed with cotton, glass wool. or TNT compresses for phase separation. The analytes-containing micelles were eluted from the mini-columns by a stream of 3 mol L(-1) HCl solution and the analytes were determined by FAAS. Chemical and flow variables affecting the preconcentration of the analytes were studied. For 15 mL. of preconcentrated solution, the enhancement factors varied between 15.1 and 20.3, the limits of detection were approximately 4.5 and 0.75 mu g L(-1) for lead and cadmium, respectively. For a solution containing 100 and 10 mu g L(-1) of lead and cadmium, respectively, the R.S.D. values varied from 1.6 to 3.2% (n = 7). The accuracy of the preconcentration system was evaluated by recovery measurements on spiked water samples. The method was susceptible to matrix effects, but these interferences were minimized by adding barium ions as masking agent in the sample solutions, and recoveries from spiked sample varied in the range of 95.1-107.3%. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study, a simple, rapid and sensitive HPLC method with UV detection is described for determination of metformin in plasma samples from bioequivalence assays. Sample preparation was accomplished through protein precipitation with acetonitrile and chromatographic separation was performed on a reversed-phase phenyl column at 40 degrees C. Mobile phase consisted of a mixture of phosphate buffer and acetonitrile at flow rate of 1.0 ml/min. Wavelength was set at 236 nm. The method was applied to a bioequivalence study of two drug products containing metformin, and allowed determination of metformin at low concentrations with a higher throughput than previously described methods. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To evaluate the prevalence of chronic autoimmune thyroiditis (CAT) and iodine-induced hypothyroidism, hyperthyroidism (overt and subclinical). and goiter in a population exposed to excessive iodine intake for 5 years (table salt iodine concentrations: 40-100 mg/kg salt). Design: This was a population-based, cross-sectional study with 1085 participants randomly selected from a metropolitan area in Sao Paulo, Brazil, and conducted during the first semester of 2004. Methods: Thyroid ultrasound examination was performed in all participants and samples of urine and blood were collected from each subject. Serum levels of thyroid-stimulating hormone, free thyroxine, and anti-thyroid peroxidase (TPO) antibodies, urinary iodine concentration. thyroid volume, and thyroid echogenicity were evaluated. We also analyzed table salt iodine concentrations. Results: At the time the study was conducted, table salt iodine concentrations were within the new official limits (20-60 mg/kg salt). Nevertheless, in 45.6%, of the participants, urinary iodine excretion was excessive (above 300 mu g/l) and, in 14.1%, it was higher than 400 mu g/l. The prevalence of CAT (including atrophic thyroiditis) was 16.9% (183/1085), women were more affected than men (21.5 vs 9.1% respectively, P=0.02). Hypothyroidism was detected in 8.0%, (87/1085) of the Population with CAT. Hyperthyroidism was diagnosed in 3.3% of the individuals (36/1085) and goiter was identified in 3.1% (34/1085). Conclusions: Five years of excessive iodine intake by the Brazilian population may have increased the prevalence of CAT and hypothyroidism in subjects genetically predisposed to thyroid autoimmune diseases. Appropriate screening for early detection of thyroid dysfunction may be considered during excessive nutritional iodine intake.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new flow-injection analytical procedure is proposed for the determination of the total amount of polyphenols in wines; the method is based on the formation of a colored complex between 4-aminoantipyrine and phenols, in the presence of an oxidizing reagent. The oxidizing agents hexacyanoferrate(III), peroxodisulfate, and tetroxoiodate(VII) were tested. Batch trials were first performed to select appropriate oxidizing agents, pH, and concentration ratios of reagents, on the basis of their effect on the stability of the colored complex. Conditions selected as a result of these trials were implemented in a flow-injection analytical system in which the influence of injection volume, flow rate, and reaction- coil length, was evaluated. Under the optimum conditions the total amount of polyphenols, expressed as gallic acid, could be determined within a concentration range of 36 to 544 mg L–1, and with a sensitivity of 344 L mol–1 cm–1 and an RSD <1.1%. The reproducibility of analytical readings was indicative of standard deviations <2%. Interference from sugars, tartaric acid, ascorbic acid, methanol, ammonium sulfate, and potassium chloride was negligible. The proposed system was applied to the determination of total polyphenols in red wines, and enabled analysis of approximately 55 samples h–1. Results were usually precise and accurate; the RSD was <3.9% and relative errors, by the Folin–Ciocalteu method, <5.1%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report the detection of specific IgA antibodies and the determination of IgG avidity in sequential serum samples from a patient exhibiting significant levels of Toxoplasma-specific IgM antibodies for seven years after the onset of the clinical symptoms of toxoplasmosis. IgM antibodies were detected by an indirect immunofluorescence test and by three commercial enzyme-linked immunosorbent assays (ELISA). Anti-T. gondii IgA was quantified by the a-capture ELISA technique using a commercial kit. As defined by the manufacturer of the IgA ELISA test used, most patients with acute toxoplasmosis have antibody levels > 40 arbitrary units per ml (AU/mL). At this cut-off level, the patient still had a positive ELISA result (45 AU/mL) in a serum sample taken one year after the beginning of clinical manifestations. The IgG avidity-ELISA test was performed with the Falcon assay screening test (F.A.S.T.®) - ELISA system. Avidity indices compatible with a recent Toxoplasma infection were found only in serum samples taken during the first 5 months after the onset of the clinical symptoms of toxoplasmosis. These results show that the interpretation of positive IgM results as indicative of recently acquired toxoplasmosis requires additional laboratory confirmation either by other tests or by the demonstration of a significant rise in the antibody titers in sequential serum samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A gas chromatography-mass spectrometry (GC-MS) method is presented which allows the simultaneous determination of the plasma concentrations of the levo-alpha-acetylmethadol (LAAM) and of its active metabolites (NorLAAM and DiNorLAAM), after derivatization with the reagent trifluoroacetic anhydride (TFAA). No interferences from endogenous compounds were observed following the extraction of plasma samples from 11 different human subjects. The standard curves were linear over a working range of 5-200ng/ml for the three compounds. Recoveries measured at three concentrations ranged from 47 to 67% for LAAM, from 50 to 69% for NorLAAM and from 28 to 50% for DiNorLAAM. Intra- and interday coefficients of variation determined at three concentrations ranged from 5 to 13% for LAAM, from 3 to 9% for NorLAAM and from 5 to 13% for DiNorLAAM. The limits of quantitation of the method were found to be 4ng/ml for the three compounds. No interference was noted from methadone. This sensitive and specific analytical method could be useful for assessing the in vivo relationship between LAAM's blood levels, clinical efficacy and/or cardiotoxicity

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A gas chromatographic-mass spectrometric method is presented which allows the determination of chlorzoxazone and 6-hydroxychlorzoxazone after derivatization with the reagent N-tert.-butyldimethylsilyl-N-methyltrifluoroacetamide. No interference was observed from endogenous compounds following the extraction of plasma samples from six different human subjects. The standard curves were linear over a working range of 20 to 4000 ng/ml and of 20 to 1000 ng/ml for chlorzoxazone and 6-hydroxychlorzoxazone, respectively. Recoveries ranged from 65 to 97% for the two compounds and intra- and inter-day coefficients of variation were always less than 9%. The limit of quantitation of the method was found to be 5 ng/ml for the two compounds, hence allowing its use for single low dose pharmacokinetics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Pollen is one of the main causes of allergic sensitization. It is not easy to make an etiological diagnosis of pollen-allergic patients because of the wide variety of sensitizing pollens, association with food allergy, and increasing incidence of polysensitization, which may result from the presence of allergens that are common to different species, as is the case of panallergens. OBJECTIVE To compare the results of skin prick tests (SPT) using whole pollen extract with specific immunoglobulin (Ig) E determination for several allergens (purified panallergens included) in the diagnosis of polysensitized pollen-allergic patients. METHODS The study sample comprised 179 pollen-sensitized patients who underwent SPT with pollen extract and allergen-specific IgE determination against different allergens. RESULTS The level of concordance between the traditional diagnostic test (SPT) and IgE determination was low, especially in patients sensitized to the panallergens profilin and polcalcin. In the case of SPT, the results demonstrated that patients who are sensitized to either of these panallergens present a significantly higher number of positive results than patients who are not. However, IgE determination revealed that while patients sensitized to polcalcins are sensitized to allergens from a higher number of pollens than the rest of the sample, this is not the case in patients sensitized to profilins. On the other hand, sensitization to profilin or lipid transfer proteins was clearly associated with food allergy. CONCLUSIONS Sensitization to panallergens could be a confounding factor in the diagnosis of polysensitized pollen-allergic patients as well as a marker for food allergy. However, more studies are required to further investigate the role of these molecules.