995 resultados para biological attachment devices
Resumo:
Background Reports of iatrogenic thermal injuries during laparoscopic surgery using new generation vessel-sealing devices, as well as anecdotal reports of hand burn injuries during hand-assisted surgeries, have evoked questions about the temperature safety profile and the cooling properties of these instruments. Methods This study involved video recording of temperatures generated by different instruments (Harmonic ACE [ACE], Ligasure V [LV], and plasma trisector [PT]) applied according the manufacturers` pre-set settings (ACE setting 3; LV 3 bars, and the PT TR2 50W). The video camera used was the infrared Flex Cam Pro directed to three different types of swine tissue: (1) peritoneum (P), (2) mesenteric vessels (MV), and (3) liver (L). Activation and cooling temperature and time were measured for each instrument. Results The ACE device produced the highest temperatures (195.9 degrees +/- 14.5 degrees C) when applied against the peritoneum, and they were significantly higher than the other instruments (LV = 96.4 degrees +/- 4.1 degrees C, and PT = 87 degrees +/- 2.2 degrees C). The LV and PT consistently yielded temperatures that were < 100 degrees C independent of type of tissue or ""on""/ ""off"" mode. Conversely, the ACE reached temperatures higher than 200 degrees C, with a surprising surge after the instrument was deactivated. Moreover, temperatures were lower when the ACE was applied against thicker tissue (liver). The LV and PT cooling times were virtually equivalent, but the ACE required almost twice as long to cool. Conclusions The ACE increased the peak temperature after deactivation when applied against thick tissue (liver), and the other instruments inconsistently increased peak temperatures after they were turned off, requiring few seconds to cool down. Moreover, the ACE generated very high temperatures (234.5 degrees C) that could harm adjacent tissue or the surgeon`s hand on contact immediately after deactivation. With judicious use, burn injury from these instruments can be prevented during laparoscopic procedures. Because of the high temperatures generated by the ACE device, particular care should be taken when it is used during laparoscopy.
Resumo:
Although Amblyomma brasiliense Arag (a) over tildeo 1908 has been reported as one of the most aggressive ticks to humans in Brazil, information about the biology of this tick species is virtually inexistent. This work reports data on the life cycle of A. brasiliense fed on rabbits and pigs and maintained in an incubator at 20 degrees C, 90% RH and 12 h of light for off-host development. Tick yield of adult females fed on pigs and rabbits was 81.2% and 58.3%, respectively. Females fed on pigs had mean engorgement weight of 862.3 mg and egg mass of 208 mg, while females fed on rabbits had mean engorgement weight of 606.1 mg and egg mass of 160 mg; these values did not differ statistically between host species. Feeding period of female ticks fed on pigs (10 days) was significantly shorter than that on rabbits (17 days). Mean preoviposition period was slightly longer (35.9 days) for ticks fed on pigs than on rabbits (30 days). The minimum incubation period of eggs of ticks from both host species was similar and over 100 days. Egg production efficiency was low for females fed on both hosts (less than 30% and 20% for ticks from pigs and rabbits, respectively). More than 55% of larvae and 79% of nymphs fed on rabbits, set free inside the feeding chambers, engorged successfully. These ticks attained an engorgement weight of 1.3 and 18.2 mg, respectively, and fed for approximately 5 days. The minimum pre-molt period was 30 days for engorged larvae and over 44 days for nymphs. Molting success was low, less than 50% in the case of larvae and less than 20% for nymphs. Further studies are required to better determine the off-host requirements of this tick species.
Resumo:
Recently we conducted the molecular characterization of Rangelia vitalii, a protozoan with high pathogenicity for young dogs in southern Brazil. To date, the descriptions of the disease have been restricted to natural infection cases. Therefore, this study aimed to evaluate the parasitemia, biological cycles and clinical-pathological findings in dogs experimentally infected with R. vitalii in the acute phase of disease, and also aimed to test a therapeutic protocol based on the diminazene aceturate. For this study, we used 12 young dogs (females), separated into two groups. Group A was composed of healthy dogs, not-infected (n = 5), and Group B consisted of animals infected with R. vitalii (n = 7). After infection, the animals were monitored by blood smear examinations, which showed intra-erythrocytic forms of the parasite 5 days post-infection (PI). Parasitemia increased progressively in these animals and had the highest peak of circulating parasites between 9 and 11 days PI. Subsequently, the parasitemia reduced and the protozoan was seen inside the leukocytes in days 17, 19 and 21 PI. The most prominent clinical signs observed at the 20 day PI of experiment were lethargy, fever and anorexia. We observed a decrease of hematocrit of infected animals compared with not-infected dogs, featuring a moderate anemia. Pathological evaluation of one dog in Group B at day 21 PI revealed splenomegaly, hepatomegaly, lymphadenopathy, and hemorrhages at necropsy. Histological examination showed only follicular hyperplasia in the spleen and lymph nodes, and the etiologic agent in the vascular endothelium. At 21 days PI, it was performed the treatment of dogs in Group B (n = 6) with a single dose of diminazene aceturate, which showed a curative efficacy of 100% in cleaning R. vitalii from blood of infected dogs. (C) 2011 Elsevier Inc. All rights reserved.
Resumo:
Quantitation of progesterone (P(4)) in biological fluids is often performed by radioimmunoassay (RIA), whereas liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) has been used much less often. Due to its autoconfirmatory nature, LC-MS/MS greatly minimizes false positives and interference. Herein we report and compare with RIA an optimized LC-MS/MS method for rapid, efficient, and cost-effective quantitation of P(4) in plasma of cattle with no sample derivatization. The quantitation of plasma P(4) released from three nonbiodegradable, commercial, intravaginal P(4)-releasing devices (IPRD) over 192 h in six ovariectomized cows was compared in a pairwise study as a test case. Both techniques showed similar P(4) kinetics (P > 0.05) whereas results of P(4) quantitation by RIA were consistently higher compared with LC-MS/MS (P < 0.05) due to interference and matrix effects. The LC-MS/MS method was validated according to the recommended analytical standards and displayed P(4) limits of detection (LOD) and quantitation (LOQ) of 0.08 and a 0.25 ng/mL, respectively. The high selective LC-MS/MS method proposed herein for P(4) quantitation eliminates the risks associated with radioactive handling; it also requires no sample derivatization, which is a common requirement for LC-MS/MS quantitation of steroid hormones. Its application to multisteroid assays is also viable, and it is envisaged that it may provide a gold standard technique for hormone quantitation in animal reproductive science studies. (C) 2011 Elsevier Inc. All rights reserved.
Resumo:
Retention systems for implant-retained auricular prostheses using either bar-clip attachments with 2 or 3 clips or retention with 2 or 3 magnets were wear tested (insertion and removal cycles) to simulate clinical periods of use. Measurements were taken at intervals of 540 cycles, which represents a period of use of approximately 6 months, for up to 3,240 cycles. Assessments of retentive force were carried out before, during, and after the wear test. Statistical analysis indicated that the bar-clip systems provided higher retention than the magnetic systems. The bar-clip attachment with 2 clips showed a significant loss of retentive force after wear testing (P < .05), suggesting lower durability and shorter clinical life. The retention provided by the bar-clip attachment with 3 clips remained stronger than that provided by all other systems tested. At the end of the wear test, the magnetic systems showed very little loss of retention but were still less retentive than the bar-clip systems, suggesting higher durability under clinical simulation despite the lower retention initially provided.
Resumo:
Objectives: The aim of this study was to compare the fracture strength of three techniques used to re-attach tooth fragments in sound and endodontically treated fractured teeth with or without fiber post placement. Material and methods: Ninety human lower incisors were randomly divided into three groups of 30 teeth each. In group A teeth were not subjected to endodontic treatment; while teeth from groups B and C were endodontically treated and the pulp chamber restored with a composite resin. All teeth were fractured by an axial load applied to the buccal area in order to obtain tooth fragments. Teeth from each group were then divided into three subgroups, according to the re-attachment technique: bonded-only, buccal-chamfer and circumferential chamfer. Before the re-attachment procedures, fiber posts were placed in teeth from group C using dual cure resin luting cement (Duo-Link). All teeth (groups A-C) had the fragments re-attached using a same dual cure resin luting cement. in the bonded-only group, no additional preparation was made. After re-attachment of the fragment, teeth from groups buccal and circumferential chamfer groups had a 1.0 mm depth chamfer placed in the fracture line either on buccal surfaceor along the buccal and lingual surfaces, respectively. increments of microhybid composite resin (Tetric Ceram) were used in subgroups buccal chamfer and circumferential chamfer to restore the chamfer. The specimens were loaded until fracture in the same pre-determined area. The force required to detach each fragment was recorded and the data was subjected to a three-way analysis of variance where factors Group and Re-attachment technique are independent measures and Time of fracture is a repeated measure factor (first and second) and Tukey`s test (alpha = 0.05). Results: The main factors Re-attachment technique (p = 0.04) and Time of fracture (p = 0.02) were statistically significant. The buccal and circumferential chamfer techniques were statistically similar (p > 0.05) and superior to the bonded-only group (p < 0.05). The first time of fracture was statistically superior to second time of fracture (p < 0.001). Conclusions: The use of fiber post is not necessary for the reinforcement of the tooth structure in re-attachment of endodontically treated teeth. When bonding a fractured fragment, the buccal or circumferential re-attachment techniques should be preferable in comparison with the simple re-attachment without any additional preparation. None of the techniques used for re-attachment restored the fracture strength of the intact teeth. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Background: The aim of this study was to assess the prevalence, extent, and severity of clinical attachment loss (CAL) and to investigate the association of demographic, socioeconomic, and behavioral risk indicators with CAL in an untreated isolated population in Brazil. Methods: All subjects aged >= 12 years were identified by a census. Participants were submitted to a full-mouth clinical examination of six sites per tooth and were interviewed using a structured, written questionnaire. Results: Among the 214 subjects who were interviewed and examined clinically, CAL >= 5 mm in at least one site was observed in 8% of the 12- to 19-year-olds and in all dentate subjects >= 50 years of age; the age-dependent prevalence of CAL >= 7 mm in at least one site ranged from 5% among 12- to 19-year-olds to 83% among subjects >= 50 years old. Multivariate analysis identified plaque (odds ratio [OR] = 2.8), supragingival calculus (OR = 2.9 to 10.6), age >= 30 years (OR = 11.4), and smoking (OR = 2.4) as risk indicators for CAL >= 5 mm and smoking (OR = 8.2) as a risk indicator for CAL >= 7 mm. Conclusions: CAL is highly prevalent in this isolated population. The high occurrence of CAL in young age groups and the confirmation of traditional risk indicators for CAL in this study suggest that other factors, such as host susceptibility, may be needed to explain the high levels of CAL found. Age and behavioral factors were risk indicators associated significantly with the CAL found in this population and may be useful indicators of high-risk subjects for periodontal diseases.
Resumo:
Our purpose was to evaluate the osteoconduction potential of mixed bovine bone (MBB) xenografts as an alternative for bone grafting of critical-size defects in the calvaria of rats. After surgery, in the time intervals of 1, 3, 6, and 9 months, rats were killed and their skulls collected, radiographed and histologically prepared for analysis. The data obtained from histological analysis reported that the particles of MBB did not promote an intense immunological response, evidencing its biocompatibility in rats. Our results clearly showed the interesting evidence that MBB was not completely reabsorbed at 9 months while a small amount of newly formed bone was deposited by osteoprogenitor cells bordering the defect. However, this discrete bone-forming stimulation was unable to regenerate the bone defect. Overall, our results suggest that the properties of MBB are not suitable for stimulating intense bone regeneration in critical bone defects in rats.
Resumo:
P>The aim of this study was to validate an original portable device to measure attachment retention of implant overdentures both in the lab and in clinical settings. The device was built with a digital force measurement gauge (Imada) secured to a vertical wheel stand associated with a customized support to hold and position the denture in adjustable angulations. Sixteen matrix and patrix cylindrical stud attachments (Locator (R)) were randomly assigned as in vitro test specimens. Attachment abutments were secured in an implant analogue hung to the digital force gauge or to the load cell of a traction machine used as the gold standard (Instron Universal Testing Machine). Matrices were secured in a denture duplicate attached to the customized support, permitting reproducibility of their position on both pulling devices. Attachment retention in the axial direction was evaluated by measuring maximum dislodging force or peak load during five consecutive linear dislodgments of each attachment on both devices. After a wear simulation, retention was measured again at several time periods. The peak load measurements with the customized Imada device were similar to those obtained with the gold standard Instron machine. These findings suggest that the proposed portable device can provide accurate information on the retentive properties of attachment systems for removable dental prostheses.
Resumo:
Benedenia Diesing, 1858, a genus of capsalid (benedeniine) monogeneans, is redefined. The generic diagnosis is amended to include: the path of tendons in the haptor from extrinsic muscles in the body; presence and form of the marginal valve; a penis occupying a penis canal with weakly muscular wall; a weakly muscular accessory gland reservoir proximal to the penis and enclosed by a proximal extension of the wall of the penis canal; male and female genital apertures usually common, rarely separate; vagina with pore usually close to the common genital pore but may open in mid body between the germarium and the common genital pore, or anterior to the common genital pore. A conservative approach is adopted and the generic diagnosis is clarified and broadened to accommodate species that display some variation in reproductive anatomy, especially of the female system. We argue against potential alternative actions such as defining Benedenia strictly to contain species with separate male and female genital apertures and against recognition of a separate genus, Tareenia Hussey, 1986, for species with a vaginal pore anterior to the common genital pore. Under our conception, Benedenia comprises 21 species: B. sciaenae (van Beneden, 1856) Odhner, 1905 (type species); B. acanthopagri (Hussey, 1986) comb. nov.; B. anticavaginata Byrnes, 1986; B. bodiani Yamaguti, 1968; B. elongata (Yamaguti, 1968) Egorova, 1997; B. epinepheli (Yamaguti, 1937) Meserve, 1938; B. hawaiiensis Yamaguti, 1968; B. hendorffi(von Linstow, 1889) Odhner, 1905; B. hoshinai Ogawa, 1984; B. innobilitata Burhnheim Gomes and Varela, 1973: B. jaliscana Bravo-Hollis, 1952; B. lolo Yamaguti, 1968; B. lutjani Whittington and Kearn, 1993: B. monticellii (Parona and Perugia, 1895) Johnston, 1929; B. ovata (Goto, 1894) Johnston. 1929: B. pompatica Burhnheim, Gomes and Varela, 1973; B. rohdei Whittington, Kearn and Beverley-Burton, 1994; B. scari Yamaguti, 1968; B. sekii (Yamaguti, 1937) Meserve, 1938; B, seriolae (Yamaguti, 1934) Meserve, 1938; and B. synagris Yamaguti, 1953. The type species, B. sciaenae, is redescribed based on new material from Australia. No types for this taxon were designated and we have assigned a series of voucher specimens. Tareenia acanthopagri Hussey, 1986 becomes B. acanthopagri (Hussey, 1986) comb. nov. and T. anticavaginata (Byrnes, 1986) Egorova, 1997 and T. lutjani (Whittington and Kearn, 1993) Egorova, 1997 are returned to Benedenia as B. anticavaginata and B. lutjani Benedenia akaisaki Iwata, 1990 is considered a synonym of B. ovata and B. kintoki Iwata, 1990 is considered a synonym of B. elongata. Two species, B, madai Ishii and Sawada, 1938 and B. pagrosomi Ishii and Sawada, 1938, are considered species inquirendae. Based on the redefinition of Benedenia, the diagnosis for the Benedeniinae is amended. Tareenia is synonymized with Benedenia but Menziesia Gibson, 1976 is recognized and its generic diagnosis amended to include: anterior attachment organs tending to form a 'hooded' appearance; prominent anterior gland cells between the pharynx and the anterior margin of the body: long penis, tapering proximally, occupying a penis canal with weakly muscular wall: penis canal and penis describe a sigmoid; accessory gland reservoir dorsal and alongside, or posterior and lateral to, proximal end of the penis and enclosed by a proximal extension of the wall of the penis canal. Under this conception. Menziesia comprises: M. noblei (Menzies. 1946) Gibson, 1976 (type species); M. malaboni (Velasquez. 1982) comb. nov.: M. merinthe (Yamaguti, 1968) Gibson. 1976: M. ovalis (Yamaguti, 1968) Gibson, 1976: and M. sebastodis (Yamaguti, 1934) comb, nov. A key to valid species of Benedenia and Menziesia is provided and a list is presented of published records of undescribed or unattributed species of Benedenia. Some protocols are suggested for preparation of benedeniine material to enhance future taxonomic studies and comparisons. The host-specificity and geographic distribution of species in these revised genera are discussed. The composition of the Capsalidae is discussed and some difficulties in defining and distinguishing between its different subfamilies are considered.