902 resultados para amplification-invariant


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Harmonic millimeter wave (mm-wave) generation and frequency up-conversion are experimentally demonstrated using optical injection locking and Brillouin selective sideband amplification (BSSA) induced by stimulated Brillouin scattering in a 10-km single-mode fiber. By using this method, we successfully generate third-harmonic mm-wave at 27 GHz (f(LO) - 9 GHz) with single sideband (SSB) modulation and up-convert the 2GHz intermediate frequency signal into the mm-wave band with single mode modulation of the SSB modes. In addition, the mm-wave carrier obtains more than 23 dB power gain due to the BSSA. The transmission experiments show that the generated mm-wave and up-converted signals indicate strong immunity against the chromatic dispersion of the fibers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In a previous Letter [Opt. Lett. 33, 1171 (2008)], we proposed an improved logarithmic phase mask by making modifications to the original one designed by Sherif. However, further studies in another paper [Appl. Opt. 49, 229 (2010)] show that even when the Sherif mask and the improved one are optimized, their corresponding defocused modulation transfer functions (MTFs) are still not stable with respect to focus errors. So, by further modifying their phase profiles, we design another two logarithmic phase masks that exhibit more stable defocused MTF. However, with the defocus-induced phase effect considered, we find that the performance of the two masks proposed in this Letter is better than the Sherif mask, but worse than our previously proposed phase mask, according to the Hilbert space angle. (C) 2010 Optical Society of America

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method of loop-mediated isothermal amplification (LAMP) was employed to develop a rapid and simple detection system for porcine circovirus type 2 (PCV2). The amplification could be finished in 60 min under isothermal condition at 64 degrees C by employing a set of four primers targeting the cap gene of PCV2. The LAMP assay showed higher sensitivity than the conventional PCR, with a detection limit of five copies per tube of purified PCV2 genomic DNA. No cross-reactivity was observed from the samples of other related viruses including porcine circovirus type 1 (PCV1), porcine parvovirus (PPV), porcine pseudorabies virus (PRV) and porcine reproductive and respiratory syndrome virus (PRRSV). The detection rate of PCV2 LAMP for 86 clinical samples was 96.5% and appeared greater than that of the PCR method. The LAMP assay reported can provide a rapid yet simple test of PCV2 suitable for laboratory diagnosis and pen-side detection due to ease of operation and the requirement of only a regular water bath or heat block for the reaction. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study the wave dislocations with an induced gauge potential. The topological current characterized the wave dislocations is constructed with the dual of Abelian gauge field. And the topological charges and locations of the wave dislocations are determined by the phi-mapping topological current theory. Furthermore, it is shown that the knotted wave dislocations can be described with a Hopf invariant in the wave field. At last we discussed the evolution of the knotted wave dislocations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We give a generalized Lagrangian density of 1 + 1 Dimensional O( 3) nonlinear sigma model with subsidiary constraints, different Lagrange multiplier fields and topological term, find a lost intrinsic constraint condition, convert the subsidiary constraints into inner constraints in the nonlinear sigma model, give the example of not introducing the lost constraint. N = 0, by comparing the example with the case of introducing the lost constraint, we obtain that when not introducing the lost constraint, one has to obtain a lot of various non-intrinsic constraints. We further deduce the gauge generator, give general BRST transformation of the model under the general conditions. It is discovered that there exists a gauge parameter beta originating from the freedom degree of BRST transformation in a general O( 3) nonlinear sigma model, and we gain the general commutation relations of ghost field.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have successfully achieved the integration of isothermal amplification and the subsequent analysis of specific gene fragments on poly(methyl methacrylate) microchips. In our experiments, loop-mediated isothermal amplification, which can offer higher specificity and efficiency than PCR, has been performed at a constant temperature (65 degreesC). After amplification, products could be either examined by the integrated microchip-based electrophoresis or directly observed by naked eye with SYBR Green I added into the reaction solution. By such an integrated microsystem, the amplification and the subsequent analysis of prostate-specific antigen gene with template concentration at 23 fg/muL could be finished within 15 min, which demonstrates its advantages of high specificity, good reproducibility, and fast speed in gene detection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Compared with other existing methods, the feature point-based image watermarking schemes can resist to global geometric attacks and local geometric attacks, especially cropping and random bending attacks (RBAs), by binding watermark synchronization with salient image characteristics. However, the watermark detection rate remains low in the current feature point-based watermarking schemes. The main reason is that both of feature point extraction and watermark embedding are more or less related to the pixel position, which is seriously distorted by the interpolation error and the shift problem during geometric attacks. In view of these facts, this paper proposes a geometrically robust image watermarking scheme based on local histogram. Our scheme mainly consists of three components: (1) feature points extraction and local circular regions (LCRs) construction are conducted by using Harris-Laplace detector; (2) a mechanism of grapy theoretical clustering-based feature selection is used to choose a set of non-overlapped LCRs, then geometrically invariant LCRs are completely formed through dominant orientation normalization; and (3) the histogram and mean statistically independent of the pixel position are calculated over the selected LCRs and utilized to embed watermarks. Experimental results demonstrate that the proposed scheme can provide sufficient robustness against geometric attacks as well as common image processing operations. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We show the potential application of Er3+-doped BaF2 nanoparticles prepared from microemulsion technology for 1.5 mu m amplification in telecommunication. Nanoparticles with different sizes of about 8, 10, and 20.5 nm were prepared. The XRD patterns showed the excursion of diffraction peaks. When the particle size is smaller or the diffraction angle is larger, this kind of excursion will be more serious.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel [Ru(bpy)(2) (dcbpy)NHS] labeling/aptamer-based biosensor combined with gold nanoparticle amplification for the determination of lysozyme with an electrochemiluminescence (ECL) method is presented. In this work, an aptamer, an ECL probe, gold nanoparticle amplification, and competition assay are the main protocols employed in ECL detection. With all the protocols used, an original biosensor coupled with an aptamer and [Ru(bpy)(2)(dcbpy)NHS] has been prepared. Its high selectivity and sensitivity are the main advantages over other traditional [Ru(bpy)(3)](2+) biosensors. The electrochemical impedance spectroscopy (EIS) and atomic force microscopy (AFM) characterization illustrate that this biosensor is fabricated successfully. Finally, the biosensor was applied to a displacement assay in different concentrations of lysozyme solution, and an ultrasensitive ECL signal was obtained. The ECL intensity decreased proportionally to the lysozyme concentration over the range 1.0 x 10-(13)-1.0 x 10(-8) mol L-1 with a detection limit of 1.0 x 10(-13) mol L-1.