992 resultados para Yersinia pestis F1 antigen detection


Relevância:

30.00% 30.00%

Publicador:

Resumo:

If Schistosoma mansoni infection could be detected in its early stages, especially before the egg deposition in the host tissues, the development of severe pathologic lesions could be efficiently prevented. We therefore developed an indirect enzyme-linked immunosorbent assay based on the detection of specific IgG against schistosomula antigens (ELISA-SmTeg). The assay was applied in sera samples from non-infected and infected mice collected seven and 15 days post-infection. The results were compared to the number of adult worms obtained by perfusion of the murine hepatic system 50 days post-infection. The sensitivity and specificity of the ELISA-SmTeg were 100% (p = 0.0032 and 0.0048 respectively for seven and 15 days of infection) with a cutoff value of 0.15 (p = 0.0002). Our findings show a novel low-cost serological assay using antigens which are easy to obtain, which was able to detect all the infected mice as early as seven days post-infection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

 This study aimed to assess the exposure of free-living jaguars (Panthera onca) to Leptospira spp. and Brucella abortus in two conservation units in the Pantanal of Mato Grosso, Brazil. The presence of antibodies in blood samples of eleven jaguars was investigated using autochthonous antigens isolated in Brazil added to reference antigen collection applied to diagnosis of leptospirosis by Microscopic Agglutination Test (MAT). The Rose Bengal test was applied for B. abortus antibodies. Two (18.2%) jaguars were seroreactive for the Leptospira spp. antigen and the serovar considered as most infective in both animals was a Brazilian isolate of serovar Canicola (L01). All jaguars were seronegative for B. abortus. These data indicate that the inclusion of autochthonous antigens in serological studies can significantly increase the number of reactive animals, as well as modify the epidemiological profile of Leptospira spp. infection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

SUMMARYAIDS-related cryptococcal meningitis continues to cause a substantial burden of death in low and middle income countries. The diagnostic use for detection of cryptococcal capsular polysaccharide antigen (CrAg) in serum and cerebrospinal fluid by latex agglutination test (CrAg-latex) or enzyme-linked immunoassay (EIA) has been available for over decades. Better diagnostics in asymptomatic and symptomatic phases of cryptococcosis are key components to reduce mortality. Recently, the cryptococcal antigen lateral flow assay (CrAg LFA) was included in the armamentarium for diagnosis. Unlike the other tests, the CrAg LFA is a dipstick immunochromatographic assay, in a format similar to the home pregnancy test, and requires little or no lab infrastructure. This test meets all of the World Health Organization ASSURED criteria (Affordable, Sensitive, Specific, User friendly, Rapid/robust, Equipment-free, and Delivered). CrAg LFA in serum, plasma, whole blood, or cerebrospinal fluid is useful for the diagnosis of disease caused by Cryptococcusspecies. The CrAg LFA has better analytical sensitivity for C. gattii than CrAg-latex or EIA. Prevention of cryptococcal disease is new application of CrAg LFA via screening of blood for subclinical infection in asymptomatic HIV-infected persons with CD4 counts < 100 cells/mL who are not receiving effective antiretroviral therapy. CrAg screening of leftover plasma specimens after CD4 testing can identify persons with asymptomatic infection who urgently require pre-emptive fluconazole, who will otherwise progress to symptomatic infection and/or die.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Vibrio cholerae has been sporadically isolated from rivers in Tucumán, Argentina, since the outbreak in 1991. The aim of this study was to determine the environmental reservoir of the bacterium in these rivers, assessing the presence of Vibrio cholerae non-O1 and O1 (the latter both in its viable culturable and non culturable state) and its relationship to environmental physicochemical variables. 18 water samplings were collected in the Salí River (in Canal Norte and Banda) and the Lules River between 2003 and 2005. Physical-chemical measurements (pH, water temperature, electrical conductivity and dissolved oxygen) were examined. Vibrio cholerae was investigated with conventional culture methods and with Direct Immunofluorescence (DFA-VNC) in order to detect viable non culturable organisms. All isolated microorganisms corresponded to Vibrio cholerae non-O1 and non-O139 (Lules 26%, Canal Norte 33% and Banda 41%). The majority was found during spring and summer and correlated with temperature and pH. Non culturable Vibrio cholerae O1 was detected year round in 38 of the 54 water samples analyzed. Application of the Pearson correlation coefficient revealed that there was no relationship between positive immunofluorescence results and environmental physicochemical parameters. Genes coding for somatic antigen O1 were confirmed in all DFA-VNC-positive samples, whereas the virulence-associated ctxA and tcpA genes were confirmed in 24 samples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AbstractINTRODUCTION:Hepatic fibrosis progression in patients with chronic hepatitis C virus infections has been associated with viral and host factors, including genetic polymorphisms. Human platelet antigen polymorphisms are associated with the rapid development of fibrosis in HCV-monoinfected patients. This study aimed to determine whether such an association exists in human immunodeficiency virus-1/hepatitis C virus-coinfected patients.METHODS:Genomic deoxyribonucleic acid from 36 human immunodeficiency virus-1/hepatitis C virus-coinfected patients was genotyped to determine the presence of human platelet antigens-1, -3, or -5 polymorphisms. Fibrosis progression was evaluated using the Metavir scoring system, and the patients were assigned to two groups, namely, G1 that comprised patients with F1, portal fibrosis without septa, or F2, few septa (n = 23) and G2 that comprised patients with F3, numerous septa, or F4, cirrhosis (n = 13). Fisher's exact test was utilized to determine possible associations between the human platelet antigen polymorphisms and fibrosis progression.RESULTS:There were no deviations from the Hardy-Weinberg equilibrium in the human platelet antigen systems evaluated. Statistically significant differences were not observed between G1 and G2 with respect to the distributions of the allelic and genotypic frequencies of the human platelet antigen systems.CONCLUSION:The greater stimulation of hepatic stellate cells by the human immunodeficiency virus and, consequently, the increased expression of transforming growth factor beta can offset the effect of human platelet antigen polymorphism on the progression of fibrosis in patients coinfected with the human immunodeficiency virus-1 and the hepatitis C virus.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Prostate cancer (PCa) is the most common form of cancer in men, in Europe (World Health Organization data). The most recent statistics, in Portuguese territory, confirm this scenario, which states that about 50% of Portuguese men may suffer from prostate cancer and 15% of these will die from this condition. Its early detection is therefore fundamental. This is currently being done by Prostate Specific Antigen (PSA) screening in urine but false positive and negative results are quite often obtained and many patients are sent to unnecessary biopsy procedures. This early detection protocol may be improved, by the development of point-of-care cancer detection devices, not only to PSA but also to other biomarkers recently identified. Thus, the present work aims to screen several biomarkers in cultured human prostate cell lines, serum and urine samples, developing low cost sensors based on new synthetic biomaterials. Biomarkers considered in this study are the following: prostate specific antigen (PSA), annexin A3 (ANXA3), microseminoprotein-beta (MSMB) and sarcosine (SAR). The biomarker recognition may occurs by means of molecularly imprinted polymers (MIP), which are a kind of plastic antibodies, and enzymatic approaches. The growth of a rigid polymer, chemically stable, using the biomarker as a template allows the synthesis of the plastic antibody. MIPs show high sensitivity/selectivity and present much longer stability and much lower price than natural antibodies. This nanostructured material was prepared on a carbon solid. The interaction between the biomarker and the sensing-material produces electrical signals generating quantitative or semi-quantitative data. These devices allow inexpensive and portable detection in point-of-care testing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fifty-three patients with histologically proven carcinoma were injected with highly purified [131I]-labeled goat antibodies or fragments of antibodies against carcinoembryonic antigen (CEA). Each patient was tested by external photoscanning 4, 24, 36 and 48 h after injection. In 22 patients (16 of 38 injected with intact antibodies, 5 of 13 with F(ab')2 fragments and 1 of 2 with Fab' fragments), an increased concentration of 131I radioactivity corresponding to the previously known tumor location was detected by photoscanning 36-48 h after injection. Blood pool and secreted radioactivity was determined in all patients by injecting 15 min before scanning, [99mTc]-labeled normal serum albumin and free 99mTc04-. The computerized subtraction of 99mTc from 131I radioactivity enhanced the definition of tumor localization in the 22 positive patients. However, in spite of the computerized subtraction, interpretation of the scans remained doubtful for 12 patients and was entirely negative for 19 additional patients. In order to provide a more objective evaluation for the specificity of the tumor localization of antibodies, 14 patients scheduled for tumor resection were injected simultaneously with [131I]-labeled antibodies or fragments and with [125I]-labeled normal goat IgG or fragments. After surgery, the radioactivity of the two isotopes present either in tumor or adjacent normal tissues was measured in a dual channel scintillation counter. The results showed that the antibodies or their fragments were 2-4 times more concentrated in the tumor than in the normal tissues. In addition, it was shown that the injected antibodies formed immune complexes with circulating CEA and that the amount of immune complexes detectable in serum was roughly proportional to the level of circulating CEA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The presence of viral antigen in sections from formalin-fixed and paraffin-embedded human tissues was demonstrated by trypsin digestion followed by direct or indirect immunofluorescence. The specimens may be used for retrospective diagnosis. The immunofluorescence technique has to be adapted to the suspected virus infection on the basis of previous histopathology study. Variations of trypsin concentration time and temperature of incubation, expose different viral antigens and have to be previously tested for each unknown system. For measles virus detection in lung a stronger digestion has to be applied as compared to adenovirus or respiratory disease viruses in the same tisue. Flavivirus in liver tissue needs a weaker digestion. The reproducibility of the method makes it useful as a routine technique in diagnosis of virus infection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: Timely diagnosis of invasive candidiasis (IC) remains difficult as the clinical presentation is not specific and blood cultures lack sensitivity and need a long incubation time. Thus, non-culture-based methods for diagnosing IC have been developed. Mannan antigen (Mn) and anti-mannan antibodies (A-Mn) are present in patients with IC. On behalf of the Third European Conference on Infections in Leukemia, the performance of these tests was analysed and reviewed. METHODS: The literature was searched for studies using the commercially available sandwich enzyme-linked immunosorbent assays (Platelia™, Bio-Rad Laboratories, Marnes-la-Coquette, France) for detecting Mn and A-Mn in serum. The target condition of this review was IC defined according to 2008 European Organization for Research and Treatment of Cancer/Mycoses Study Group criteria. Sensitivity, specificity and diagnostic odds ratios (DOR) were calculated for Mn, A-Mn and combined Mn/A-Mn testing. RESULTS: Overall, 14 studies that comprised 453 patients and 767 controls were reviewed. The patient populations included in the studies were mainly haematological and cancer cases in seven studies and mainly intensive care unit and surgery cases in the other seven studies. All studies but one were retrospective in design. Mn sensitivity was 58% (95% confidence interval [CI], 53-62); specificity, 93% (95% CI, 91-94) and DOR, 18 (95% CI 12-28). A-Mn sensitivity was 59% (95% CI, 54-65); specificity, 83% (95% CI, 79-97) and DOR, 12 (95% CI 7-21). Combined Mn/A-Mn sensitivity was 83% (95% CI, 79-87); specificity, 86% (95% CI, 82-90) and DOR, 58 (95% CI 27-122). Significant heterogeneity of the studies was detected. The sensitivity of both Mn and A-Mn varied for different Candida species, and it was the highest for C. albicans, followed by C. glabrata and C. tropicalis. In 73% of 45 patients with candidemia, at least one of the serological tests was positive before the culture results, with mean time advantage being 6 days for Mn and 7 days for A-Mn. In 21 patients with hepatosplenic IC, 18 (86%) had Mn or A-Mn positive test results at a median of 16 days before radiological detection of liver or spleen lesions. CONCLUSIONS: Mn and A-Mn are useful for diagnosis of IC. The performance of combined Mn/A-Mn testing is superior to either Mn or A-Mn testing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents the evaluation of an enzyme immunoassay in which Mayaro virus-infected cultured cells ara used as antigen (EIA-ICC) and an IgM antibody capture ELISA (MAC-ELISA) for Mayaro serologic diagnosis using 114 human sera obtained during a Mayaro outbreak occurred in Bolivia, in 1987. Results were compared with those obtained by haemagglutination-inhibition test (HAI). MAC-ELISA was the most sensitive technique for anti-Mayaro IgM detection. MAC-ELISA was twice sensitive as IgM EIA-ICC. The data shows that MAC-ELISA is a practical and valid technique for diagnosis of recent mayaro infection. IgG-ICC showed hight sensitivity and high specificity compared to HAI. The combination of anti-Mayaro IgG and IgM EIA-ICC results presented the highest sensitivity of the study. Anti-Mayaro IgG and IgM simultaneous detection by ELISA-ICC can be used for recent infection diagnosis (in spite of a less sensitive IgM detection than by MAC-ELISA), for surveillance and sero-epidemiologic studies, and for studies of IgG and IgM responses to Mayaro infection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simple and rapid staphylococcal coagglutination test for the detection of Toxoplasma gondii antigens in mice urine is described. A suspension of protein-A containing Staphylococcus aureus coated with rabbit hyperimmune serum was used as reagent. The sensitivity of the antigen assay was found to be at least 118 ng of the antigen protein per ml. No coagglutination was observed when the reagent was challenged against antigenic solutions of other parasites. The suitability of the method for detecting antigens of T. gondii in urine samples was studied by experimental toxoplasma infection in mice. Before the staphylococcal test, the urine samples were double serially diluted in 0.1 M PBS. From the second day on all samples from infected mice were positive at 1/16 dilution. At this dilution, all samples from non infected mice were negative or did not produce coagglutination. This method might be used in the rapid etiological diagnosis also in human cases of acute toxoplasmosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Low efficiency of transfection is often the limiting factor for acquiring conclusive data in reporter assays. It is especially difficult to efficiently transfect and characterize promoters in primary human cells. To overcome this problem we have developed a system in which reporter gene expression is quantified by flow cytometry. In this system, green fluorescent protein (GFP) reporter constructs are co-transfected with a reference plasmid that codes for the mouse cell surface antigen Thy-1.1 and serves to determine transfection efficiency. Comparison of mean GFP expression of the total transfected cell population with the activity of an analogous luciferase reporter showed that the sensitivity of the two reporter systems is similar. However, because GFP expression can be analyzed at the single-cell level and in the same cells the expression of the reference plasmid can be monitored by two-color fluorescence, the GFP reporter system is in fact more sensitive, particularly in cells which can only be transfected with a low efficiency.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Two groups of Schistosoma japonicum infected patients (acute and chronic ) and non-infected individuals were studied using IgA antibody to egg antigen (SEA) and IgG and IgM antibodies to keyhole limpet haemocyanin (KLH). The means and standard deviation of the optical density in ELISA of acute, chronic and negative groups for IgA anti-SEA were 583±124.7, 98.2±78.8 and 82.2±39. 3, respectively. There was a statistically significance between acute patients and chronic patients (P<0.01). The means and standard deviation of IgG and IgM antibodies to KLH were 501.5±150.6, 113.0±79.1, 28.8±56.3 and 413.6±148.5, 70.2±14.8, 65.3±45.3, respectively. The detection results of IgA to SEA compared with the IgG and IgM to KLH did not demonstrate a significant difference (P>0.01). The sensitivities of IgA to SEA and IgG and IgM antibodies to KLH for the detection of acute infection were 95.24%, 90.48% and 85.71%, respectively. Therefore, this study showed that the detection of IgA to SEA is also a useful new method for the serological differentiation of acute and chronic schistosomiasis japonica in humans.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Flow cytometry has been used as a powerful technique for studying cell surface antigen expression as well as intracellular molecules. Its capability of analyzing multiple parameters simultaneously on a single cell has allowed identification and studies of functional cell subsets within heterogeneous populations. In this respect, several techniques have been developed during the past few years to study cytokine-producing cells by flow cytometry in humans and several animal models.