974 resultados para WEIGHTED EARLINESS
Resumo:
PURPOSE: To prospectively evaluate feasibility and reproducibility of diffusion-weighted (DW) and blood oxygenation level-dependent (BOLD) magnetic resonance (MR) imaging in patients with renal allografts, as compared with these features in healthy volunteers with native kidneys. MATERIALS AND METHODS: The local ethics committee approved the study protocol; patients provided written informed consent. Fifteen patients with a renal allograft and in stable condition (nine men, six women; age range, 20-67 years) and 15 age- and sex-matched healthy volunteers underwent DW and BOLD MR imaging. Seven patients with renal allografts were examined twice to assess reproducibility of results. DW MR imaging yielded a total apparent diffusion coefficient including diffusion and microperfusion (ADC(tot)), as well as an ADC reflecting predominantly pure diffusion (ADC(D)) and the perfusion fraction. R2* of BOLD MR imaging enabled the estimation of renal oxygenation. Statistical analysis was performed, and analysis of variance was used for repeated measurements. Coefficients of variation between and within subjects were calculated to assess reproducibility. RESULTS: In patients, ADC(tot), ADC(D), and perfusion fraction were similar in the cortex and medulla. In volunteers, values in the medulla were similar to those in the cortex and medulla of patients; however, values in the cortex were higher than those in the medulla (P < .05). Medullary R2* was higher than cortical R2* in patients (12.9 sec(-1) +/- 2.1 [standard deviation] vs 11.0 sec(-1) +/- 0.6, P < .007) and volunteers (15.3 sec(-1) +/- 1.1 vs 11.5 sec(-1) +/- 0.5, P < .0001). However, medullary R2* was lower in patients than in volunteers (P < .004). Increased medullary R2* was paralleled by decreased diffusion in patients with allografts. A low coefficient of variation in the cortex and medulla within subjects was obtained for ADC(tot), ADC(D), and R2* (<5.2%), while coefficient of variation within subjects was higher for perfusion fraction (medulla, 15.1%; cortex, 8.6%). Diffusion and perfusion indexes correlated significantly with serum creatinine concentrations. CONCLUSION: DW and BOLD MR imaging are feasible and reproducible in patients with renal allografts.
Resumo:
Diffusion-weighted MRI has become more and more popular in the last couple of years. It is already an accepted diagnostic tool for patients with acute stroke, but is more difficult to use for extracranial applications due to technical challenges mostly related to motion sensitivity and susceptibility variations (e.g., respiration and air-tissue boundaries). However, thanks to the newer technical developments, applications of body DW-MRI are starting to emerge. In this review, we aim to provide an overview of the current status of the published data on DW-MRI in extracranial applications. A short introduction to the physical background of this promising technique is provided, followed by the current status, subdivided into three main topics, the functional evaluation, tissue characterization and therapy monitoring.
Resumo:
PURPOSE: To evaluate and compare the efficacy of proximal versus distal embolus protection devices (EPD) during carotid artery angioplasty/stenting (CAS) based on diffusion-weighted magnetic resonance imaging (DW-MRI). METHODS: Forty-four patients (31 men; mean age 68 years, range 48-85) underwent protected CAS and had DW-MRI before and after the intervention. The cohort was analyzed according to the type of EPD used: a proximal EPD was deployed in 25 (56.8%) patients (17 men; mean age 66 years, range 48-85) and a distal filter in 19 (14 men; mean age 70 years, range 58-79). Fifteen (60.0%) patients with proximal protection were symptomatic of the target lesion; in the distal protection group, 10 (52.6%) were symptomatic. RESULTS: New lesions were seen on the postinterventional DW-MRI in 28.0% (7/25) of the proximal EPD group versus 32.6% (6/19) of those with a distal filter (p = NS). The majority were clinically silent. The new lesions in the vascular territory of the stented carotid artery in the group as a whole and per patient were fewer in the proximal EPD group (p = NS). No significant differences were noted in the T(2) appearance of the new lesions or the number of new lesions observed away from the vascular territory of the stented artery. CONCLUSION: Proximal embolus protection devices show a nonsignificant trend toward fewer embolic events, which warrants large-scale studies. Furthermore, proximal protection devices can be useful to control and treat acute in-stent thrombosis.
Resumo:
We report a case of a 34-year-old woman who had a left anterior wall myocardial infarction develop in the first trimester of pregnancy. Despite urgent and successful revascularization, she demonstrated persistent segmental wall motion abnormalities by transthoracic echocardiography. To manage this patient safely through pregnancy with a better definition of myocardium at risk, a cardiac magnetic resonance examination was performed. This identified a large territory of acutely edematous myocardium in addition to providing accurate volumetric measurements of left ventricular size and function. Because of her gravid state, gadolinium was not administered nor was it required to delineate the region of myocardium at risk.
Resumo:
In a technical development study approved by the institutional ethics committee, the feasibility of fast diffusion-weighted imaging as a replacement for conventional magnetic resonance (MR) imaging sequences (short inversion time inversion recovery [STIR] and T1-weighted spin echo [SE]) and positron emission tomography (PET)/computed tomography (CT) in the detection of skeletal metastases from prostate cancer was evaluated. MR imaging and carbon 11 ((11)C) choline PET/CT data from 11 consecutive prostate cancer patients with bone metastases were analyzed. Diffusion-weighted imaging appears to be equal, if not superior, to STIR and T1-weighted SE sequences and equally as effective as (11)C-choline PET/CT in detection of bone metastases in these patients. Diffusion-weighted imaging should be considered for further evaluation and comparisons with PET/CT for comprehensive whole-body staging and restaging in prostate and other cancers.
Resumo:
BACKGROUND: Lymph node staging of bladder or prostate cancer using conventional imaging is limited. Newer approaches such as ultrasmall superparamagnetic particles of iron oxide (USPIO) and diffusion-weighted magnetic resonance imaging (DW-MRI) have inconsistent diagnostic accuracy and are difficult to interpret. OBJECTIVE: To assess whether combined USPIO and DW-MRI (USPIO-DW-MRI) improves staging of normal-sized lymph nodes in bladder and/or prostate cancer patients. DESIGN, SETTING, AND PARTICIPANTS: Twenty-one consecutive patients with bladder and/or prostate cancer were enrolled between May and October 2008. One patient was excluded secondary to bone metastases detected on DW-MRI with subsequent abstention from surgery. INTERVENTION: Patients preoperatively underwent 3-T MRI before and after administration of lymphotropic USPIO using conventional MRI sequences combined with DW-MRI. Surgery consisted of extended pelvic lymphadenectomy and resection of primary tumors. MEASUREMENTS: Diagnostic accuracies of the new combined USPIO-DW-MRI approach compared with the "classic" reading method evaluating USPIO images without and with DW-MRI versus histopathology were evaluated. Duration of the two reading methods was noted for each patient. RESULTS AND LIMITATIONS: Diagnostic accuracy (90% per patient or per pelvic side) was comparable for the classic and the USPIO-DW-MRI reading method, while time of analysis with 80 min (range 45-180 min) for the classic and 13 min (range 5-90 min) for the USPIO-DW-MRI method was significantly shorter (p<0.0001). Interobserver agreement (three blinded readers) was high with a kappa value of 0.75 and 0.84, respectively. Histopathological analysis showed metastases in 26 of 802 analyzed lymph nodes (3.2%). Of these, 24 nodes (92%) were correctly diagnosed as positive on USPIO-DW-MRI. In two patients, one micrometastasis each (1.0x0.2 mm; 0.7x0.4 mm) was missed in all imaging studies. CONCLUSIONS: USPIO-DW-MRI is a fast and accurate method for detecting pelvic lymph node metastases, even in normal-sized nodes of bladder or prostate cancer patients.
Resumo:
OBJECTIVE: The aim of the present pilot study is to show initial results of a multimodal approach using clinical scoring, morphological magnetic resonance imaging (MRI) and biochemical T2-relaxation and diffusion-weighted imaging (DWI) in their ability to assess differences between cartilage repair tissue after microfracture therapy (MFX) and matrix-associated autologous chondrocyte transplantation (MACT). METHOD: Twenty patients were cross-sectionally evaluated at different post-operative intervals from 12 to 63 months after MFX and 12-59 months after MACT. The two groups were matched by age (MFX: 36.0+/-10.4 years; MACT: 35.1+/-7.7 years) and post-operative interval (MFX: 32.6+/-16.7 months; MACT: 31.7+/-18.3 months). After clinical evaluation using the Lysholm score, 3T-MRI was performed obtaining the MR observation of cartilage repair tissue (MOCART) score as well as T2-mapping and DWI for multi-parametric MRI. Quantitative T2-relaxation was achieved using a multi-echo spin-echo sequence; semi-quantitative diffusion-quotient (signal intensity without diffusion-weighting divided by signal intensity with diffusion weighting) was prepared by a partially balanced, steady-state gradient-echo pulse sequence. RESULTS: No differences in Lysholm (P=0.420) or MOCART (P=0.209) score were observed between MFX and MACT. T2-mapping showed lower T2 values after MFX compared to MACT (P=0.039). DWI distinguished between healthy cartilage and cartilage repair tissue in both procedures (MFX: P=0.001; MACT: P=0.007). Correlations were found between the Lysholm and the MOCART score (Pearson: 0.484; P=0.031), between the Lysholm score and DWI (Pearson:-0.557; P=0.011) and a trend between the Lysholm score and T2 (Person: 0.304; P=0.193). CONCLUSION: Using T2-mapping and DWI, additional information could be gained compared to clinical scoring or morphological MRI. In combination clinical, MR-morphological and MR-biochemical parameters can be seen as a promising multimodal tool in the follow-up of cartilage repair.
Resumo:
PURPOSE: To compare dynamic contrast material-enhanced magnetic resonance (MR) imaging and diffusion-weighted MR imaging for noninvasive evaluation of early and late effects of a vascular targeting agent in a rat tumor model. MATERIALS AND METHODS: The study protocol was approved by the local ethics committee for animal care and use. Thirteen rats with one rhabdomyosarcoma in each flank (26 tumors) underwent dynamic contrast-enhanced imaging and diffusion-weighted echo-planar imaging in a 1.5-T MR unit before intraperitoneal injection of combretastatin A4 phosphate and at early (1 and 6 hours) and later (2 and 9 days) follow-up examinations after the injection. Histopathologic examination was performed at each time point. The apparent diffusion coefficient (ADC) of each tumor was calculated separately on the basis of diffusion-weighted images obtained with low b gradient values (ADC(low); b = 0, 50, and 100 sec/mm(2)) and high b gradient values (ADC(high); b = 500, 750, and 1000 sec/mm(2)). The difference between ADC(low) and ADC(high) was used as a surrogate measure of tissue perfusion (ADC(low) - ADC(high) = ADC(perf)). From the dynamic contrast-enhanced MR images, the volume transfer constant k and the initial slope of the contrast enhancement-time curve were calculated. For statistical analyses, a paired two-tailed Student t test and linear regression analysis were used. RESULTS: Early after administration of combretastatin, all perfusion-related parameters (k, initial slope, and ADC(perf)) decreased significantly (P < .001); at 9 days after combretastatin administration, they increased significantly (P < .001). Changes in ADC(perf) were correlated with changes in k (R(2) = 0.46, P < .001) and the initial slope (R(2) = 0.67, P < .001). CONCLUSION: Both dynamic contrast-enhanced MR imaging and diffusion-weighted MR imaging allow monitoring of perfusion changes induced by vascular targeting agents in tumors. Diffusion-weighted imaging provides additional information about intratumoral cell viability versus necrosis after administration of combretastatin.