928 resultados para Two-dimensional model
Resumo:
The objective of this work was to evaluate interactions of Lumbricus terrestris juveniles with adults and with inherited burrow systems. An experiment was set up using a two dimensional Evans' boxes microcosm. Adult L. terrestris were added to 16 boxes (one individual per box) and kept in darkness at 17ºC along with eight unoccupied boxes for two months. The adult L. terrestris were removed from eight randomly selected boxes, and L. terrestris juveniles were added (one juvenile per box), composing three treatments with eight replicates: 1, with an adult in an inherited burrow (ABJ); 2, alone in an inherited burrow (BJ); and 3, alone in a previously uninhabited box (J). The proportion of juveniles occupying adult burrows observed was significantly different in treatments ABJ (48%) and BJ (75%). The mean mass of juveniles at experimental termination differed significantly among treatments and was greater in treatment J (4.04±0.39 g) in comparison to the BJ (3.09±0.93 g) and ABJ treatments (2.13±0.64 g). Results suggest a negative influence of both the presence of an adult and its burrow system on juvenile growth. Intraspecific competition partially explained this, but further investigation is required to examine how an inherited environment (i.e. burrow) could negatively affect the growth of juveniles.
Resumo:
Compared to synthetic aperture radars (SARs), the angular resolution of microwave radiometers is quite poor. Traditionally, it has been limited by the physical size of the antenna. However, the angular resolution can be improved by means of aperture synthesis interferometric techniques. A narrow beam is synthesized during the image formation processing of the cross-correlations measured at zero-lag between pairs of signals collected by an array of antennas. The angular resolution is then determined by the maximum antenna spacing normalized to the wavelength (baseline). The next step in improving the angular resolution is the Doppler-Radiometer, somehow related to the super-synthesis radiometers and the Radiometer-SAR. This paper presents the concept of a three-antenna Doppler-Radiometer for 2D imaging. The performance of this instrument is evaluated in terms of angular/spatial resolution and radiometric sensitivity, and an L-band illustrative example is presented.
Resumo:
The purpose of this study is to clinically validate a new two-dimensional preoperative planning software for cementless total hip arthroplasty (THA). Manual and two-dimensional computer-assisted planning were compared by an independent observer for each of the 30 patients with osteoarthritis who underwent THA. This study showed that there were no statistical differences between the results of both preoperative plans in terms of stem size and neck length (<1 size) and hip rotation center position (<5 mm). Two-dimensional computer-assisted preoperative planning provided successful results comparable to those using the manual procedure, thereby allowing the surgeon to simulate various stem designs easily.
Resumo:
We reconsider a model of two relativistic particles interacting via a multiplicative potential, as an example of a simple dynamical system with sectors, or branches, with different dynamics and degrees of freedom. The presence or absence of sectors depends on the values of rest masses. Some aspects of the canonical quantization are described. The model could be interpreted as a bigravity model in one dimension.
Resumo:
Diplomityön tarkoituksena on kehittää kolmiulotteinen malli kerrosleijupoltolle. Työn kirjallisuusosa sisältää seuraavat perusteet kerrosleijupolton tekniikasta: yleistiedot, leijutus- ja palamisilmiöt, kiinteän aineen ja kaasun sekoittuminen, päästöt ja lämmönsiirto. Lisäksi palamissysteemin mallinnuksen perusteet ja ratkaisumenetelmät ovat esitelty. Työn mallinnusosassa kehitetty koodi on ohjelmoitu Fortran-ohjelmointikielellä. Kehitetty malli perustuu olemassa olevaan malliin kiertoleijupoltosta. Yhtälö kiintoainekonsentraatioprofiilille on vaihdettu ja kiertovirta on poistettu koodista. Mallilla on tehty herkkyystarkasteluja polttoaineen ja kaasun sekoittumisen sekä reaktiokertoimen vaikutukselle. Visualisointi on tehty ohjelmassa Tecplot 360 ja mallinnustuloksia on vertailtu mitattuihin tuloksiin. Mallin laskemattulokset vastaavat hyvin mittaustuloksia ja kokemusperäisiä tietoja; monissa tapauksissa malli pystyy kvantitatiivisesti kuvaamaan parametrien variointia ja kaikissa tapauksissa malli antaa ainakin kvalitatiivisesti oikeita tuloksia. Työhön liittyvän kehityksen ja mallinnuskokemuksen perusteella on tehty ehdotukset mallin tulevaa kehitystä ja mittauksia varten.
Resumo:
A weak version of the cosmic censorship hypothesis is implemented as a set of boundary conditions on exact semiclassical solutions of two-dimensional dilaton gravity. These boundary conditions reflect low-energy matter from the strong coupling region and they also serve to stabilize the vacuum of the theory against decay into negative energy states. Information about low-energy incoming matter can be recovered in the final state but at high energy black holes are formed and inevitably lead to information loss at the semiclassical level.
Resumo:
We consider a renormalizable two-dimensional model of dilaton gravity coupled to a set of conformal fields as a toy model for quantum cosmology. We discuss the cosmological solutions of the model and study the effect of including the back reaction due to quantum corrections. As a result, when the matter density is below some threshold new singularities form in a weak-coupling region, which suggests that they will not be removed in the full quantum theory. We also solve the Wheeler-DeWitt equation. Depending on the quantum state of the Universe, the singularities may appear in a quantum region where the wave function is not oscillatory, i.e., when there is not a well-defined notion of classical spacetime.
Resumo:
PURPOSE: To improve coronary magnetic resonance angiography (MRA) by combining a two-dimensional (2D) spatially selective radiofrequency (RF) pulse with a T2 -preparation module ("2D-T2 -Prep"). METHODS: An adiabatic T2 -Prep was modified so that the first and last pulses were of differing spatial selectivity. The first RF pulse was replaced by a 2D pulse, such that a pencil-beam volume is excited. The last RF pulse remains nonselective, thus restoring the T2 -prepared pencil-beam, while tipping the (formerly longitudinal) magnetization outside of the pencil-beam into the transverse plane, where it is then spoiled. Thus, only a cylinder of T2 -prepared tissue remains for imaging. Numerical simulations were followed by phantom validation and in vivo coronary MRA, where the technique was quantitatively evaluated. Reduced field-of-view (rFoV) images were similarly studied. RESULTS: In vivo, full field-of-view 2D-T2 -Prep significantly improved vessel sharpness as compared to conventional T2 -Prep, without adversely affecting signal-to-noise (SNR) or contrast-to-noise ratios (CNR). It also reduced respiratory motion artifacts. In rFoV images, the SNR, CNR, and vessel sharpness decreased, although scan time reduction was 60%. CONCLUSION: When compared with conventional T2 -Prep, the 2D-T2 -Prep improves vessel sharpness and decreases respiratory ghosting while preserving both SNR and CNR. It may also acquire rFoV images for accelerated data acquisition.
Resumo:
To determine the feasibility of data transfer, an interlaboratory comparison was conducted on colon carcinoma cell line (DLD-1) proteins resolved by two-dimensional polyacrylamide gel electrophoresis either on small (6 x 7 cm) or large (16x18 cm) gels. The gels were silver-stained and scanned by laser densitometry, and the image obtained was analyzed using Melanie software. The number of spots detected was 1337+/-161 vs. 2382+/-176 for small vs. large format gels, respectively. After gel calibration using landmarks determined using pl and Mr markers, large- and small-format gels were matched and 712+/-36 proteins were found on both types of gels. Having performed accurate gel matching it was possible to acquire additional information after accessing a 2-D PAGE reference database (http://www.expasy.ch/ cgibin/map2/def?DLD1_HUMAN). Thus, the difference in gel size is not an obstacle for data transfer. This will facilitate exchanges between laboratories or consultation concerning existing databases.
Resumo:
The article describes some concrete problems that were encountered when writing a two-level model of Mari morphology. Mari is an agglutinative Finno-Ugric language spoken in Russia by about 600 000 people. The work was begun in the 1980s on the basis of K. Koskenniemi’s Two-Level Morphology (1983), but in the latest stage R. Beesley’s and L. Karttunen’s Finite State Morphology (2003) was used. Many of the problems described in the article concern the inexplicitness of the rules in Mari grammars and the lack of information about the exact distribution of some suffixes, e.g. enclitics. The Mari grammars usually give complete paradigms for a few unproblematic verb stems, whereas the difficult or unclear forms of certain verbs are only superficially discussed. Another example of phenomena that are poorly described in grammars is the way suffixes with an initial sibilant combine to stems ending in a sibilant. The help of informants and searches from electronic corpora were used to overcome such difficulties in the development of the two-level model of Mari. The variation of the order of plural markers, case suffixes and possessive suffixes is a typical feature of Mari. The morphotactic rules constructed for Mari declensional forms tend to be recursive and their productivity must be limited by some technical device, such as filters. In the present model, certain plural markers were treated like nouns. The positional and functional versatility of the possessive suffixes can be regarded as the most challenging phenomenon in attempts to formalize the Mari morphology. Cyrillic orthography, which was used in the model, also caused problems. For instance, a Cyrillic letter may represent a sequence of two sounds, the first being part of the word stem while the other belongs to a suffix. In some cases, letters for voiced consonants are also generalized to represent voiceless consonants. Such orthographical conventions distance a morphological model based on orthography from the actual (morpho)phonological processes in the language.
Resumo:
Comprehensive two-dimensional gas chromatography coupled with time-of-flight mass spectrometry was used for the identification of forty doping agents. The improvement in the specificity was remarkable, allowing the resolution of analytes that could not be done by one-dimensional chromatographic systems. The sensitivity observed for different classes of prohibited substances was clearly below the value required by the World Anti-Doping Agency. In addition time-of-flight mass spectrometry gives full spectrum for all analytes without any interference from the matrix, resulting in selectivity improvements. These results could support the implementation of an exhaustive monitoring approach for hundreds of doping agents in a single injection.