544 resultados para Tubos
Resumo:
A serious problem that affects an oil refinery s processing units is the deposition of solid particles or the fouling on the equipments. These residues are naturally present on the oil or are by-products of chemical reactions during its transport. A fouled heat exchanger loses its capacity to adequately heat the oil, needing to be shut down periodically for cleaning. Previous knowledge of the best period to shut down the exchanger may improve the energetic and production efficiency of the plant. In this work we develop a system to predict the fouling on a heat exchanger from the Potiguar Clara Camarão Refinery, based on data collected in a partnership with Petrobras. Recurrent Neural Networks are used to predict the heat exchanger s flow in future time. This variable is the main indicator of fouling, because its value decreases gradually as the deposits on the tubes reduce their diameter. The prediction could be used to tell when the flow will have decreased under an acceptable value, indicating when the exchanger shutdown for cleaning will be needed
Resumo:
O objetivo deste trabalho foi avaliar o efeito do tratamento de sementes com inseticidas e um bioestimulante na germinação no crescimento da planta e raiz de soja. Foram realizados dois experimentos em delineamento de blocos ao acaso, em que as sementes foram tratadas com aldicarb, thiametoxan, imidacloprid e duas testemunhas: uma sem produto e uma com bioestimulante. em laboratório, as unidades experimentais constituíram-se de rolos de papel toalha com sementes de soja, para avaliar o vigor, a germinação, as plantas anormais e mortas, o comprimento de radículas e de plântulas. Nos testes em casa de vegetação, as unidades experimentais constituíram-se de tubos de PVC, com volume de 16 dm³, e foram avaliados: os teores de N, P e K; a matéria seca; o comprimento, a área e o raio médio radicular; a eficiência de absorção de N, P e K; e a taxa de crescimento radicular da soja. Os tratamentos de sementes de soja com os inseticidas e o bioestimulante levam à formação de raízes mais finas, o que caracteriza um efeito tônico. O produto aldicarb, na dose empregada, prejudica o vigor e a germinação das sementes de soja. O tratamento de sementes com inseticidas e bioestimulante não proporciona maior crescimento das raízes das plantas de soja.
Resumo:
O presente trabalho foi desenvolvido em casa de vegetação na Faculdade de Ciências Agronômicas UNESP, com o objetivo de determinar o efeito no crescimento inicial da soja e na formação do sistema radicular ao longo do tempo da presença de resíduos de sorgo-de-guiné e forrageiro. As unidades experimentais constituíram-se de tubos de PVC (rhizotron) com volume de terra de 16 dm-3. O delineamento experimental utilizado foi inteiramente casualizado num fatorial 2 x 3, sendo duas variedades de sorgo e três manejos dos resíduos de sorgo, com quatro repetições. A palha de sorgo-de-guiné na superfície do solo levou à diminuição na saturação do solo por bases. As palhas de sorgo de ambas as variedades, na superfície do solo, prejudicaram o crescimento da soja, o que também foi observado no caso das raízes do sorgo forrageiro. Resíduos culturais do sorgo-de-guiné, principalmente a palha, são os responsáveis por menores crescimentos das partes aérea e radicular da soja e, conseqüentemente, pelo menor acúmulo de nutrientes.
Resumo:
An solar alternative system for water heating is presented. Is composed for one low cost alternative collector and alternative thermal reservoir for hot water storing. The collector of the system has box confectioned in composite material and use absorption coils formed for PVC tubes. The box of hot water storage was confectioned from a plastic polyethylene drum used for storage of water and garbage, coated for a cylinder confectioned in fiber glass. The principle of functioning of the system is the same of the conventionally. Its regimen of work is the thermosiphon for a volume of 250 liters water. The main characteristic of the system in considered study is its low cost, allowing a bigger socialization of the use of solar energy. It will be demonstrated the viabilities thermal, economic and of materials of the system of considered heating, and its competitiveness in relation to the available collectors commercially. Relative aspects will be boarded also the susceptibility the thermal degradation and for UV for the PVC tubes. It will be shown that such system of alternative heating, that has as main characteristic its low cost, presents viabilities thermal, economic and of materials
Resumo:
A solar alternative system for water heating is presented. It work on a thermosiphon, consisting of one or two alternative collectors and a water storage tank also alternative, whose main purpose is to socialize the use of energy mainly to be used by people of low income. The collectors were built from the use of pets bottles, cans of beer and soft drinks and tubes of PVC, ½ " and the thermal reservoirs from a drum of polyethylene used for storage of water and garbage placed inside cylinder of fiber glass and EPS ground between the two surfaces. Such collectors are formed by three elements: pet bottles, cans and tubes absorbers. The heating units, which form the collector contains inside the cans that can be closed, in original form or in the form of plate. The collectors have an absorber grid formed by eight absorbers PVC tube, connected through connections at T of the same material and diameter. It will be presented data of the thermal parameters which demonstrate the efficiency of the heating system proposed. Relative aspects will be boarded also the susceptibility the thermal degradation and for UV for the PVC tubes. It will be demonstrated that this alternative heating system, which has as its main feature low cost, presents thermal, economic and materials viabilities
Resumo:
A análise da fluorescência da clorofila vem sendo largamente utilizada no entendimento dos mecanismos da fotossíntese propriamente dito, bem como na avaliação da capacidade fotossintética alterada com a aplicação de herbicidas. O consumo de água pelas plantas é uma maneira também de avaliar a atuação dos herbicidas nas plantas daninhas. O objetivo deste trabalho foi avaliar a fluorescência através da taxa de transporte de elétrons, consumo de água e fitointoxicação de Brachiaria decumbens após aplicação de quatro herbicidas de diferentes mecanismos de ação. Aos 30 dias após a semeadura de B. decumbens, as plantas foram arrancadas dos tubetes e preparadas para os tratamentos. Elas tiveram o sistema radicular colocado em tubos falcon preenchidos com água, e a superfície dos falcon foi isolada com papel-alumínio, para evitar evaporação do sistema. Os herbicidas aplicados foram: glyphosate, haloxyfop-methyl, diuron e amicarbazone. A aplicação foi feita com um pulverizador estacionário instalado em laboratório; após a aplicação dos tratamentos, as plantas foram mantidas em casa de vegetação. Foi avaliada a taxa de transporte de elétrons (ETR), o consumo de água e a fitointoxicação das plantas em vários períodos após o início do experimento. Os dados de ETR e fitointoxicação foram expressos em porcentagem da testemunha e submetidos à análise de variância e à comparação das médias. Para o consumo de água, os dados foram acumulados e ajustados por modelos de regressão. Assim, pode-se dizer que as plantas de B. decumbens tiveram respostas diferentes aos herbicidas aplicados, e o consumo de água das plantas está relacionado diretamente com o transporte de elétrons. A metodologia fundamentada no fluorômetro mostrou-se adequada para verificar a intoxicação antecipada em B. de cumbens submetidas ao amicarbazone e diuron antes mesmo da verificação visual de intoxicação.
Resumo:
The modern technology of materials and structural integrity of pipelines requests the use of inspection tools named inspection pigs to detect, localize and measure the length, width and depth dimensions of the thickness losses of walls of buried and underwater pipelines in service. These tools run them internally, performing and recording measurements, with performance that varies according to the pig s technology. It has been developed recently an instrumented pig technology, called feller pig. This work aims to indicate factors that influence the feller pig technology performance in the detection and in the accuracy of measurement of the length, width and depth dimensions of the thickness losses on the internal surface of an oil pipeline wall under normal conditions of oil pipe inspection with pig. In this work, is made a collection of factors and an analyses of the technology based on the available literature, as well as an experiment to observe the technology and the factors operating. In the experiment, a feeler pig is used in a pipeline built in carbon steel and in operation that flows petroleum, in witch are observed areas with internal thickness losses occurred naturally. Some of these areas and their dimensions taken by automated ultra-sound scanner are compared with the ones indicated by the feller pig. Based on the data collection, on the analysis and on the experiment, the influence of factors object of this research is discussed. It is concluded that, among these, there are factors related to pipe fabrication tolerances, to wear of pig components, to internal adhesive wear of pipeline, to other pipeline damages and to technology characteristics. Finally, actions are suggested to know better, improve and define the applicability of this technology
Resumo:
It s presented a solar collector to be used in a system for heating bath water, whose main characteristic is its low cost. The collector consists of five plates of PVC with 10 mm thick, 200 mm in width and 1400mm in length, with an area equal to 1.4 square meters. The plates were connected in parallel to the ends of PVC tubes of 40 mm and 32 mm. The plates were coated on one side with aluminum sheets of soft drinks and beers cans open. The system worked on a thermosiphon and was tested in two configurations: the plates uncoated and coated with aluminum material, to determine the influence of material on the efficiency of the collector. For both configurations was used EPS plates below the surface to minimize heat losses from the botton. The thermal reservoir of the heating system is, also, alternative and low cost, since it was constructed from a polyethylene tank for storing water, with volume of 150 end 200 liters. It will be presented the thermal efficiency, heat loss, water temperature of the thermal reservoir at the end of the process and simulation of baths for a house with four residents. The will be demonstrated thermal, economic and material viability of the proposed collector, whose main innovation is the use of recyclables materials, cans of beer and soft drinks, to increase the temperature of the absorber plate.
Resumo:
It presents a solar collector to be used in a system for heating water for bathing, whose main characteristics are its low cost and easy manufacturing and assembly. The absorbing surface of the collector is formed by an aluminum plate with eight flaps where they lodge PVC pipes. The catchment area of solar radiation corresponds to 1.3 meters. The collector box was made of wood, is covered by transparent glass and thermal insulation of tire chips and expanded polystyrene (EPS). Absorber tubes were connected in parallel through the use of PVC fittings and fixed to the plate by the use of metal poles and rivets. The entire absorber received paint flat black for better absorption of sunlight. The system worked on a thermosiphon assembly and absorber of the collector has been tested in two configurations: with the tubes facing up, directly exposed to the impact of sunlight and facing down, exchanging heat with the plate by conduction. It was determined the most efficient configuration for the correct purpose. The solar collector was connected to a thermal reservoir, also alternative, low-cost forming the system of solar water heating. We evaluated thermal parameters that proved the viability of the heating system studied
Resumo:
It presents a solar collector to be used in a system for heating water for bathing, whose main characteristics are low cost and easy manufacturing and assembly. The system operates under natural convection or thermosiphon. The absorbing surface of the collector is formed by twelve PVC pipes of 25 mm outside diameter connected in parallel via connections in T of the same material. The tubes were covered with absorbing fins made with recycled aluminum cans. We studied eight settings between absorber plate, thermal insulating EPS boards and thermal reservoirs 150 and 200 liters. It was determined the most efficient configuration for the correct purpose. We evaluated thermal parameters that proved the viability of the heating system studied
Resumo:
The technical and economic viability of solar heating for swimming pools is unquestionable, besides there it replaces the high costs and environmental impacts of conventional supply of energy, and it improves an optimization in the pool heating uses. This work applies the principles of the greenhouse effect: advanced thermodynamics, heat retention and equalization of temperature, to optimize the solar heating equipment, reducing the area required by collectors as much as 40% (still estimated value) for commercial collectors, with minor architectural and aesthetic impacts on the environment. It features a solar heating alternative in pools, whose main characteristics: low cost, simplicity in manufacturing and assembly and a faster heating. The system consists of two collectors spiral hoses made of polyethylene with a hundred meters each, and working on a forced flow, with only one pass of the working fluid inside the coils, and is used to pump itself treatment of pool water to obtain the desired flow. One of the collectors will be exposed to direct solar radiation, and the other will be covered by a glass slide and closed laterally, so providing the greenhouse effect. The equipment will be installed in parallel and simultaneously exposed to the sun in order to obtain comparative data on their effectiveness. Will be presented results of thermal tests for this the two cases, with and without transparent cover. Will be demonstrated, by comparison, the thermal, economic and material feasibility of these systems for heating swimming pools.
Resumo:
We studied the feasibility of using a system of Solar Water Heating (SAS) with low cost, for three configurations. In configurations I and II have the collector grid absorber composed of six PVC tubes placed in parallel on the tile cement. In configuration II, the PVC tubes were transparent cover made of plastic bottles. Configuration III uses a collector composed of 12 black HDPE pipes, supported on four cement tiles 2.44 m x 0.50 m, two by two overlapping and interspersed with a filling of glass wool, comprising an area exposed to the global radiation incident of 2.44 m2, with the top two tiles painted matte black. In this configuration, the HDPE pipes replace conventional PVC pipes painted black. The total cost of SAS for configuration III, the most economical, was around $ 150.00. For the configurations tested the system of operation was thermosyphon collector. The study showed that the proposed systems have good thermal efficiency, are easy to install and handle and have low cost compared to conventional.
Resumo:
It was studied a system for heating water to be used to obtain water for bathing at home, the absorbing surface of the collector is formed by one plate of polycarbonate. The polycarbonate plate has 6 mm thick, 1.050 mm wide and 1.500 mm long with an area equal to 1,575 m². The plate was attached by its edges parallel to PVC tubes of 32 mm. The system worked under the thermo-siphon and was tested for two configurations: plate absorber with and without isolation of EPS of 30 mm thick on the bottom surface in order to minimize heat losses from the bottom. The tank's thermal heating system is alternative and low cost, since it was constructed from a polyethylene reservoir for water storage, with a volume of 200 liters. Will present data on the thermal efficiency, heat loss, water temperature of thermal reservoir at the end of the process simulation and baths. Will be demonstrated the feasibility of thermal, economic and material pickup proposed for the intended purpose.
Resumo:
O objetivo deste trabalho foi avaliar o efeito de compostos orgânicos de extratos de plantas de seis espécies e da fertilização fosfatada na disponibilidade de fósforo no solo. Tubos de 30 cm de altura e 5 cm de diâmetro foram preenchidos com Latossolo Vermelho-Amarelo. Cada tubo constituiu uma parcela, em delineamento completamente casualizado, em arranjo fatorial 7x2, com quatro repetições. Extratos líquidos de aveia-preta (Avena strigosa), nabo forrageiro (Raphanus sativus), milho (Zea mays), milheto (Pennisetum glaucum), soja (Glycine max), sorgo forrageiro (Sorghum bicolor) e água (testemunha) foram aplicados em cada parcela, com ou sem fertilização com fosfato solúvel. Após sete dias de incubação, amostras de solo foram coletadas em várias profundidades, e foram analisadas as formas lábil, moderadamente lábil e não lábil de fósforo no solo. Houve acúmulo de fósforo inorgânico nas frações lábil e moderadamente lábil do solo, como conseqüência da adição dos extratos de plantas, principalmente na camada superficial (0-5 cm). O nabo forrageiro, com maior concentração de ácido málico e maior conteúdo de P no tecido do que outras espécies, foi o mais eficiente em incrementar a disponibilidade de P no solo.
Resumo:
Fillers are often added in composites to enhance performance and/or to reduce cost. Fiberglass pipes must meet performance requirements and industrial sand is frequently added for the pipe to be cost competitive. The sand is added to increase pipe wall thickness, thus increase pipe stiffness. The main goal of the present work is to conduct an experimental investigation between pipes fabricated with and without de addition of sand, to be used in the petroleum industry. Pipes were built using E-glass fibers, polyester resin and siliceous sand. The fabrication process used hand lay up and filament winding and was divided in two different parts: the liner and the structural wall. All tested pipes had the same liner, but different structural wall composition, which is the layer where siliceous sand may be added or not. The comparative investigation was developed considering the results of longitudinal tensile tests, hoop tensile tests, hydrostatic pressure leak tests and parallel-plate loading stiffness tests. SEM was used to analyze if the sand caused any damage to the glass fibers, during the fabrication process, because of the fiber-sand contact. The procedure was also used to verify the composite conditions after the hydrostatic pressure leak test. The results proved that the addition of siliceous sand reduced the leak pressure in about 17 %. In the other hand, this loss in pressure was compensated by a stiffness increment of more than 380 %. MEV analyses show that it is possible to find damage on the fiber-sand contact, but on a very small amount. On most cases, the contact occurs without damage evidences. In summary, the addition of sand filler represented a 27.8 % of cost reduction, when compared to a pipe designed with glass fiber and resin only. This cost reduction combined to the good mechanical tests results make siliceous sand filler suitable for fiberglass pressure pipes