928 resultados para Transyugular intrahepatic postosystemic shunt (TIPS)
The influence of grain size coating and shaft angulation of different diamond tips on dental cutting
Resumo:
Objectives: To evaluate the influence of the grain size coating and shaft angulation of ultrasonic and high-speed diamond burs on the dental cutting effectiveness. Materials and Methods: For the grain size evaluation, cavities were prepared on 40 incisors using high-speed (1092 and 1093F KG Sorensen®) and ultrasonic tips (8.2142 and 6.2142-CVDentus®). For the shaft angulation evaluation, cavities were prepared on 40 incisors using uniangulated (T1-CVDentus®) and biangulated (T1-A CVDentus®) ultrasonic tips. The cavities were bisected and examined at 50 magnification. The width and depth of cavities were measured by Leica QWin software. Kruskal-Wallis non-parametric test was used for analysis. Results: The grain size did not affect the cutting effectiveness, but the high-speed burs promoted deeper and wider cavities than the ultrasonic tips. The shaft angulation did not affect the cutting effectiveness; both the angulated and biangulated tips had greater cutting efficiency in dentin than in enamel. Conclusions: Ultrasonic tips promoted more conservative preparations and seemed promising for cavity preparation.
Resumo:
Considering the operation of shunt active compensators, such as active power filters, this paper proposes possible compensation strategies by means of the recent formulation of the Conservative Power Theory (CPT). The CPT current's decomposition results in several current components, which are associated with specific load characteristics (power transfer, energy storage, unbalances and/or non linearities). These current components are used for the definition of different compensation strategies, which can be selective in terms of minimizing particular disturbing effects. In order to validate the applicability of these new compensation strategies, simulation and experimental results for three-phase four-wire systems are presented. © 2011 IEEE.
Resumo:
Aim: The aim of this study was to compare the microtensile bond strength of three adhesive systems, using different methods of dentin preparation. Materials and methods: A hundred and eight bovine teeth were used. The dentin from buccal face was exposed and prepared with three different methods, divided in 3 groups: Group 1 (DT)- diamond tip on a high-speed handpiece; Group 2 (CVD)-CVD tip on a ultrasonic handpiece; Group 3 (LA)-Er: YAG laser. The teeth were divided into 3 subgroups, according adhesive systems used: Subgroup 1-Adper Single Bond Plus/3M ESPE (SB) total-etch adhesive; Subgroup 2-Adper Scotchbond SE/3M ESPE (AS) selfetching adhesive; Subgroup 3-Clearfil SE Bond/Kuraray (CS) selfetching adhesive. Blocks of composite (Filtek Z250-3M ESPE) 4 mm high were built up and specimens were stored in deionized water for 24 hours at 37°C. Serial mesiodistal and buccolingual cuts were made and stick-like specimens were obtained, with transversal section of 1.0 mm2. The samples were submitted to microtensile test at 1 mm/min and load of 10 kg in a universal testing machine. Data (MPa) were subjected to ANOVA and Tukey's tests (p < 0.05). Results and conclusion: Surface treatment with Diamond or CVD tips associated with Clearfil SE Bond adhesive produced significantly lower bond strength values compared to other groups. Surface treatment with Er: YAG laser associated with Single Bond Plus or Clearfil SE Bond adhesives and surface treatment with CVD tip associated with Adper Scotchbond SE adhesive produced significantly lower bond strength values compared to surface treatment with diamond or CVD tips associated with Single Bond Plus or Adper Scotchbond SE adhesives. Clinical significance: Interactions between laser and the CVD tip technologies and the different adhesive systems can produce a satisfactory bonding strength result, so that these associations may be beneficial and enhance the clinical outcomes.
Resumo:
Objective: To assess the influence of air abrasion tips and system operation modes on enamel cutting. Methods: Forty bovine teeth were abraded with the air abrasion system Mach 4.1 for 10 and 15 seconds, employing conventional and sonic tips of 0.45-mm inner diameter and a 90° angle, and 27.5-μm aluminum oxide at 5.51 bar air pressure in continuous and pulsed modes. The width and depth of the resulting cuts were measured in SEM. Results: The multivariate analysis of variances revealed that, compared to the sonic tip, the conventional tip produced shallower cuts independent of the operation mode and the application period. Conclusions: The cutting patterns observed in this study suggest that the pulsed mode produced deeper cuts when both the conventional and sonic tips were used, and that the sonic tip cut more dental tissue than the conventional one.
Resumo:
Objective: The aim of this study was to evaluate the degree of conversion and hardness of different composite resins, photo-activated for 40 s with two different light guide tips, fiber optic and polymer. Methods: Five specimens were made for each group evaluated. The percentage of unreacted carbon double bonds (% C=C) was determined from the ratio of absorbance intensities of aliphatic C=C (peak at 1637 cm-1) against internal standard before and after curing of the specimen: aromatic C-C (peak at 1610 cm-1. The Vickers hardness measurements were performed in a universal testing machine. A 50 gf load was used and the indenter with a dwell time of 30 seconds. The degree of conversion and hardness mean values were analyzed separately by ANOVA and Tukey's test, with a significance level set at 5%. Results: The mean values of degree of conversion for the polymer and fiber optic light guide tip were statistically different (P<.001). The hardness mean values were statistically different among the light guide tips (P<.001), but also there was difference between top and bottom surfaces (P<.001). Conclusions: The results showed that the resins photo-activated with the fiber optic light guide tip promoted higher values for degree of conversion and hardness.
Resumo:
The aim of this study was to evaluate the compressive strength of microhybrid (Filtek™ Z250) and nanofilled (Filtek™ Supreme XT) composite resins photo-activated with two different light guide tips, fiber optic and polymer, coupled with one LED. The power density was 653 mW cm -2 when using the fiber optic light tip and 596 mW cm-2 with the polymer. After storage in distilled water at 37 ± 2 °C for seven days, the samples were subjected to mechanical testing of compressive strength in an EMIC universal mechanical testing machine with a load cell of 5 kN and speed of 0.5 mm min-1. The statistical analysis was performed using ANOVA with a confidence interval of 95% and Tamhane's test. The results showed that the mean values of compressive strength were not influenced by the different light tips (p > 0.05). However, a statistical difference was observed (p < 0.001) between the microhybrid composite resin photo-activated with the fiber optic light tip and the nanofilled composite resin. Based on these results, it can be concluded that microhybrid composite resin photo-activated with the fiber optic light tip showed better results than nanofilled, regardless of the tip used, and the type of the light tip did not influence the compressive strength of either composite. Thus, the presented results suggest that both the fiber optic and polymer light guide tips provide adequate compressive strength to be used to make restorations. However, the fiber optic light tip associated with microhybrid composite resin may be an interesting option for restorations mainly in posterior teeth. © 2013 Astro Ltd.
Resumo:
The morphologically undivided ventricle of the heart in non-crocodilian reptiles permits the mixing of oxygen-rich blood returning from the lungs and oxygen-poor blood from the systemic circulation. A possible functional significance for this intra-cardiac shunt has been debated for almost a century. Unilateral left vagotomy rendered the single effective pulmonary artery of the South American rattlesnake, Crotalus durissus, unable to adjust the magnitude of blood flow to the lung. The higher constant perfusion of the lung circulation and the incapability of adjusting the right-left shunt in left-denervated snakes persisted over time, providing a unique model for investigation of the long-term consequences of cardiac shunting in a squamate. Oxygen uptake recorded at rest and during spontaneous and forced activity was not affected by removing control of the cardiac shunt. Furthermore, metabolic rate and energetic balance during the post-prandial metabolic increment, plus the food conversion efficiency and growth rate, were all similarly unaffected. These results show that control of cardiac shunting is not associated with a clear functional advantage in adjusting metabolic rate, effectiveness of digestion or growth rates. © 2013. Published by The Company of Biologists Ltd.
Resumo:
Based on the framework of the Conservative Power Theory (CPT), this paper proposes some compensation strategies for shunt current compensators. CPT current decompositions result in several current-related terms associated with specific load characteristics, such as power consumption, energy storage, unbalances and load nonlinearities. These current components are decoupled (orthogonal) from each other and are used here to define different compensation strategies, which can be selective in minimizing particular effects of disturbing loads. Compensation strategies for single- and three-phase four-wire circuits are also considered. Simulated and experimental results are described to validate the possibilities and performance of the proposed strategies. © 2013 Brazilian Society for Automatics - SBA.
Resumo:
Pós-graduação em Medicina Veterinária - FMVZ
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The establishment of laboratory colonies of ticks is often hampered by their lack of adaptation to alternative hosts. The aim of this study was to artificially feed partially engorged Dermacentor (Anocentor) nitens females through plastic tips, and to identify what are the optimal conditions of application of this technique to get as much as possible close to the natural conditions. The technique of artificial feeding through plastic tips allowed the engorgement of D. nitens ticks to a final weight within the normal range for the species. (C) 2014 Published by Elsevier GmbH.
Resumo:
Hepatic encephalopathy (HE) is a cognitive disturbance characterized by neuropsychiatric alterations. It occurs in acute and chronic hepatic disease and also in patients with portosystemic shunts. The presence of these portosystemic shunts allows the passage of nitrogenous substances from the intestines through systemic veins without liver depuration. Therefore, the embolization of these shunts has been performed to control HE manifestations, but the presence of portal vein thrombosis is considered a contraindication. In this presentation we show a cirrhotic patient with severe HE and portal vein thrombosis who was submitted to embolization of a large portosystemic shunt. Case report: a 57 years-old cirrhotic patient who had been hospitalized many times for persistent HE and hepatic coma, even without precipitant factors. She had a wide portosystemic shunt and also portal vein thrombosis. The abdominal angiography confirmed the splenorenal shunt and showed other shunts. The larger shunt was embolized through placement of microcoils, and the patient had no recurrence of overt HE. There was a little increase of esophageal and gastric varices, but no endoscopic treatment was needed. Since portosystemic shunts are frequent causes of recurrent HE in cirrhotic patients, portal vein thrombosis should be considered a relative contraindication to perform a shunt embolization. However, in particular cases with many shunts and severe HE, we found that one of these shunts can be safely embolized and this procedure can be sufficient to obtain a good HE recovery. In conclusion, we reported a case of persistent HE due to a wide portosystemic shunt associated with portal vein thrombosis. As the patient had other shunts, she was successfully treated by embolization of the larger shunt. (C) 2014 Baishideng Publishing Group Inc. All rights reserved.
Resumo:
Portosystemic shunt, an hepatobiliary anomaly, much common in dogs and less frequent in cats, can be detected by several diagnostic methods. Among them, the one which stands out is ultrasonography due to its numerous advantages: noninvasive, quick, accessible, relatively low cost and provides useful information relating to the other systems, apart from being a highly sensitive method. Portosystemic shunt diagnosis using ultrasonography becomes highly sensitive when associated with B-mode, color Doppler and pulsed Doppler. A bibliographic survey about portosystemic shunt ultrasonographic diagnosis was carried out, and the main ultrasonographic signals were: decreased hepatic size, difficulty in blood vessels visualization, presence of an anomalous vessel, tortuous with turbulent flow and, finally, increased portal blood flow velocity near the shunting vessel
Resumo:
The non-eruption of teeth due to highly keratinized gingival mucosa is a frequent event in the pediatric dentistry, which harms the oral aesthetics and function. A surgical excision of the involved area is indicated, exposing the non-erupted tooth. This procedure involves anesthesia and cutting instruments that may increase the fear and anxiety in young patients. The use of new technologies has avoided these instruments and has promoted more comfort to the patients. This study presents clinical cases in which gingivectomy was performed using the innovative method with an ultrasound-activated CVD tip. It was concluded that this method presented effectiveness, promoted more comfort, and less fear to the patients, making its use a viable alternative to pediatric surgery.