990 resultados para Transitional Flow Regime
Resumo:
Mudrocks and carbonates of the Isa superbasin in the Lawn Hill platform in northern Australia host major base metal sulfide mineralization, including the giant strata-bound Century Zn-Pb deposit. Mineral paragenesis, stable isotope, and K-Ar dating studies demonstrate that long-lived structures such as the Termite Range fault acted as hot fluid conduits several times during the Paleoproterozoic and Mesoproterozoic in response to major tectonic events. Illite and chlorite crystallinity studies suggest the southern part of the platform has experienced higher temperatures (up to 300 degrees C) than similar stratigraphic horizons in the north. The irregular downhole variation of illite crystallinity values provides further information oil the thermal regime in the basin and shows that clay formation was controlled not only by temperature increase with depth but also by high water/rock ratios along relatively permeable zones. K-Ar dating of illite, in combination with other data, may indicate three major thermal events in the central and northern Lawn Hill platform Lit 1500, 1440 to 1400, and 1250 to 1150 Ma. This study did not detect the earlier Century base metal mineralizing event at 1575 Ma. 1500 Ma ages are recorded only in the south and correspond to the age of the Late Isan orogeny and deposition of the Lower Roper superbasin. They may reflect exhumation of a provenance region. The 1440 to 1300 Ma ages are related to fault reactivation and a thermal pulse at similar to 1440 to 1400 Ma possibly accompanied by fluid flow, with subsequent enhanced cooling possibly due to thermal relaxation or further crustal exhumation. The youngest thermal and/or fluid-flow event at 1250 to 1150 Ma is recorded mainly to the cast of the Tern-lite Range fault and may be related to the assembly of the Rodinian supercontinent. Fluids in equilibrium with illite that formed over a range of temperatures, at different times in different parts of the platform. have relatively uniform oxygen isotope compositions and more variable hydrogen isotope compositions (delta O-18 = 3.5-9.7 parts per thousand V-SMOW; delta D = -94 to -36 parts per thousand V-SMOW). The extent of the 180 enrichment and the variably depleted hydrogen isotope compositions suggest the illite interacted with deep-basin hypersaline brines that were composed of evaporated seawater and/or highly evolved meteoric water. Siderite is the most abundant iron-rich gangue phase in the Century Zn-Pb deposit, which is surrounded by all extensive ferroan carbonate alteration halo. Modeling suggests that the ore siderite formed at temperatures of 120 degrees to 150 degrees C, whereas siderite and ankerite in the alteration halo formed at temperatures of 150 degrees to 180 degrees C. The calculated isotopic compositions of the fluids are consistent with O-18-rich basinal brines and mixed inorganic and organic carbon Sources (6180 = 3-10 parts per thousand V-SMOW, delta C-13 = -7 to -3 parts per thousand V-PDB). in the northeast Lawn Hill platform carbonate-rich rocks preserve marine to early diagenetic carbon and oxygen isotope compositions, whereas ferroan carbonate cements in siltstones and shales in the Desert Creek borehole are O-18 and C-13 depleted relative to the sedimentary carbonates. The good agreement between temperature estimates from illite crystallinity and organic reflectance (160 degrees-270 degrees C) and inverse correlation with carbonate delta O-18 values indicates that organic maturation and carbonate precipitation in the northeast Lawn Hill platform resulted from interaction with the 1250 to 1150 Ma fluids. The calculated isotopic compositions of the fluid are consistent with evolved basinal brine (delta O-18 = 5.1-9.4 parts per thousand V-SMOW; delta C-13 = -13.2 to -3.7 parts per thousand V-PDB) that contained a variable organic carbon component from the oxidation and/or hydrolysis of organic matter in the host sequence. The occurrence of extensive O-18- and C-13-depleted ankerite and siderite alteration in Desert Creek is related to the high temperature of the 1250 to 1150 Ma fluid-flow event in the northeast Lawn Hill platform, in contrast to the lower temperature fluids associated with the earlier Century Zn-Pb deposit in the central Lawn Hill platform.
Resumo:
Measurements were carried out to determine local coefficients of heat transfer in short lengths of horizontal pipe, and in the region of an discontinuity in pipe diameter. Laminar, transitional and turbulent flow regimes were investigated, and mixtures of propylene glycol and water were used in the experiments to give a range of viscous fluids. Theoretical and empirical analyses were implemented to find how the fundamental mechanism of forced convection was modified by the secondary effects of free convection, temperature dependent viscosity, and viscous dissipation. From experiments with the short tube it was possible to determine simple empirical relationships describing the axial distribution of the local 1usselt number and its dependence on the Reynolds and Prandtl numbers. Small corrections were made to account for the secondary effects mentioned above. Two different entrance configurations were investigated to demonstrate how conditions upstream could influence the heat transfer coefficients measured downstream In experiments with a sudden contraction in pipe diameter the distribution of local 1u3se1t number depended on the Prandtl number of the fluid in a complicated way. Graphical data is presented describing this dependence for a range of fluids indicating how the local Nusselt number varied with the diameter-ratio. Ratios up to 3.34:1 were considered. With a sudden divergence in pipe diameter, it was possible to derive the axial distribution of the local Nusse1t number for a range of Reynolds and Prandtl numbers in a similar way to the convergence experiments. Difficulty was encountered in explaining some of the measurements obtained at low Reynolds numbers, and flow visualization techniques wore used to determine the complex flow patterns which could lead to the anomalous results mentioned. Tests were carried out with divergences up to 1:3.34 to find the way in which the local Nusselt number varied with the diameter ratio, and a few experiments were carried out with very large ratios up .to 14.4. A limited amount of theoretical analysis of the 'divergence' system was carried out to substantiate certain explanations of the heat transfer mechanisms postulated.
Resumo:
It is known that distillation tray efficiency depends on the liquid flow pattern, particularly for large diameter trays. Scale·up failures due to liquid channelling have occurred, and it is known that fitting flow control devices to trays sometirr.es improves tray efficiency. Several theoretical models which explain these observations have been published. Further progress in understanding is at present blocked by lack of experimental measurements of the pattern of liquid concentration over the tray. Flow pattern effects are expected to be significant only on commercial size trays of a large diameter and the lack of data is a result of the costs, risks and difficulty of making these measurements on full scale production columns. This work presents a new experiment which simulates distillation by water cooling. and provides a means of testing commercial size trays in the laboratory. Hot water is fed on to the tray and cooled by air forced through the perforations. The analogy between heat and mass transfer shows that the water temperature at any point is analogous to liquid concentration and the enthalpy of the air is analogous to vapour concentration. The effect of the liquid flow pattern on mass transfer is revealed by the temperature field on the tray. The experiment was implemented and evaluated in a column of 1.2 m. dia. The water temperatures were measured by thennocouples interfaced to an electronic computerised data logging system. The "best surface" through the experimental temperature measurements was obtained by the mathematical technique of B. splines, and presented in tenos of lines of constant temperature. The results revealed that in general liquid channelling is more imponant in the bubbly "mixed" regime than in the spray regime. However, it was observed that severe channelling also occurred for intense spray at incipient flood conditions. This is an unexpected result. A computer program was written to calculate point efficiency as well as tray efficiency, and the results were compared with distillation efficiencies for similar loadings. The theoretical model of Porter and Lockett for predicting distillation was modified to predict water cooling and the theoretical predictions were shown to be similar to the experimental temperature profiles. A comparison of the repeatability of the experiments with an errors analysis revealed that accurate tray efficiency measurements require temperature measurements to better than ± 0.1 °c which is achievable with conventional techniques. This was not achieved in this work, and resulted in considerable scatter in the efficiency results. Nevertheless it is concluded that the new experiment is a valuable tool for investigating the effect of the liquid flow pattern on tray mass transfer.
Resumo:
Single phase solutions containing three components have been observed to exhibit foaminess near a single to two liquid phase boundary. It was seen, in a sintered plate column under mass transfer conditions, that distillation systems where the liquid appeared as one phase in one part of a column and two phases in another part, exhibited foaminess when the liquid concentration was near the one phase to two phase boundary. Various ternary systems have been studied in a 50 plate. 30mm i.d. Oldershaw column and it was observed that severe foaming occurred in the middle section of the column near the one liquid phase to two liquid phase boundary and no foaming occurred at the end of the column where liquid was either one phase or two phase. This is known as Ross type foam. Mass transfer experiments with Ross type ternary systems have been carried out in a perspex simulator with small and large hole diameter trays. It was observed that by removal of the more volatile component, Ross type foam did not build up on the tray. Severe entrainment of liquid was observed in all cases leading to a 'dry' tray, even with a low free area small diameter hole tray which was expected to produce a bubbly mixture. Entrainment was more severe for high gas superficial velocities and large hole diameters. This behaviour is quite different from the build up of foam observed when one liquid phase/two liquid phase Ross systems were contacted with air above a small sintered disc or with vapour in an Oldershaw distillation column. This observation explains why distillation columns processing mixtures which change from one liquid phase to two liquid phases (or vice versa) must be severely derated to avoid flooding. Single liquid phase holdups at the spray to bubbly transition were measured using a perspex simulator similar to that of Porter & Wong (17). i.e. with no liquid cross flow. A light transmission technique was used to measure the transition from spray regime to bubbly regime. The effect of tray thickness and the ratio of hole diameter to tray thickness on the transition was evaluated using trays of the same hole diameter and free area but having thickness of 2.38 mm, 4 mm, and 6.35 mm. The liquid holdup at the transition was less with the thin metal trays. This result may be interpreted by the theory of Lockett (101), which predicts the transition liquid holdup in terms of the angle of the gas iet leaving the holes in the sieve plate. All the existing correlations have been compared and none were found to be satisfactory and these correlations have been modified in view of the experimental results obtained. A new correlation has been proposed which takes into account the effect of the hole diameter to tray thickness ratio on the transition and good agreement was obtained between the experimental results and the correlated values of the liquid holdup at the transition. Results have been obtained for two immiscible liquids [kerosene and water] on trays to determine whether foaming can be eliminated by operating in the spray regime. Kerosene was added to a fixed volume of water or water was added to a fixed volume of kerosene. In both cases, there was a transition from spray to bubbly. In the water fixed system. the liquid holdup at the transition was slightly less than the pure kerosene system. Whilst for the kerosene fixed system, the transition occurred at much lower liquid holdups. Trends In the results were similar to those for single liquid phase. New correlations have been proposed for the two cases. It has been found that Ross type foams, observed in a sintered plate column and in the Oldershaw column can be eliminated by either carrying out the separation in a packed column or by the addition of defoaming additives.
Resumo:
Combined conduction–convection–radiation heat transfer is investigated numerically in a micro-channel filled with a saturated cellular porous medium, with the channel walls held at a constant heat flux. Invoking the velocity slip and temperature jump, the thermal behaviour of the porous–fluid system are studied by considering hydrodynamically fully developed flow and applying the Darcy–Brinkman flow model. One energy equation model based on the local thermal equilibrium condition is adopted to evaluate the temperature field within the porous medium. Combined conduction and radiation heat transfer is treated as an effective conduction process with a temperature-dependent effective thermal conductivity. Results are reported in terms of the average Nusselt number and dimensionless temperature distribution, as a function of velocity slip coefficient, temperature jump coefficient, porous medium shape parameter and radiation parameters. Results show that increasing the radiation parameter (Tr)(Tr) and the temperature jump coefficient flattens the dimensionless temperature profile. The Nusselt numbers are more sensitive to the variation in the temperature jump coefficient rather than to the velocity slip coefficient. Such that for high porous medium shape parameter, the Nusselt number is found to be independent of velocity slip. Furthermore, it is found that as the temperature jump coefficient increases, the Nusselt number decrease. In addition, for high temperature jump coefficients, the Nusselt number is found to be insensitive to the radiation parameters and porous medium shape parameter. It is also concluded that compared with the conventional macro-channels, wherein using a porous material enhances the rate of heat transfer (up to about 40 % compared to the clear channel), insertion of a porous material inside a micro-channel in slip regime does not effectively enhance the rate of heat transfer that is about 2 %.
Resumo:
Les organismes aquatiques sont adaptés à une grande variabilité hydrique et thermique des rivières. Malgré ceci, la régulation des eaux suscite des changements aux débits qui peuvent provoquer des impacts négatifs sur la biodiversité et les processus écologiques en rivière. Celle-ci peut aussi causer des modifications au niveau des régimes thermiques et des caractéristiques de l’habitat du poisson. Des données environnementales et biologiques décrivant l’habitat du poisson existent, mais elles sont incomplètes pour plusieurs rivières au Canada et de faible qualité, limitant les relations quantitatives débit-température-poissons à un petit nombre de rivières ou à une région étudiée. La recherche menée dans le cadre de mon doctorat concerne les impacts de la génération d'hydroélectricité sur les rivières; soit les changements aux régimes hydriques et thermiques reliés à la régulation des eaux sur la variation des communautés ichtyologiques qui habitent les rivières régulées et naturelles au Canada. Suite à une comparaison d’échantillonnage de pêche, une méthode constante pour obtenir des bons estimés de poisson (richesse, densité et biomasse des espèces) a été établie pour évaluer la structure de la communauté de poissons pour l’ensemble des rivières ciblées par l’étude. Afin de mieux comprendre ces changements environnementaux, les principales composantes décrivant ces régimes ont été identifiées et l’altération des régimes hydriques pour certaines rivières régulées a été quantifiée. Ces résultats ont servi à établir la relation significative entre le degré de changement biotique et le degré de changement hydrique pour illustrer les différences entre les régimes de régulation. Pour faire un complément aux indices biotiques déjà calculés pour l’ensemble des communautés de poissons (diversité, densité et biomasse des espèces par rivière), les différences au niveau des guildes de poissons ont été quantifiées pour expliquer les divers effets écologiques dus aux changements de régimes hydriques et thermiques provenant de la gestion des barrages. Ces derniers résultats servent à prédire pour quels traits écologiques ou groupes d’espèces de poissons les composantes hydriques et thermiques sont importantes. De plus, ces derniers résultats ont servi à mettre en valeur les variables décrivant les régimes thermiques qui ne sont pas toujours inclues dans les études hydro-écologiques. L’ensemble des résultats de cette thèse ont des retombées importantes sur la gestion des rivières en évaluant, de façon cohérente, l’impact de la régulation des rivières sur les communautés de poissons et en développant des outils de prévision pour la restauration des écosystèmes riverains.
Resumo:
The quality of fish cultured using recycling units may differ from that of fish from outdoor farming units due to a range of deviating environmental determinants. This applies not only to flesh quality but also to morphological (processing) traits. This study evaluates processing yields of sibling fish cultured in two different farming units: (i) an outdoor pond aquaculture system with a flow-through regime (24.6 ± 0.2°C), and (ii) indoor tanks using a recirculation aquaculture system (RAS; 26.0 ± 1.0°C). Clear differences were observed in the most important processing traits, i.e. skinned trunk and fillet yields, which were both significantly higher (P < 0.01) in RAS fish due to significantly smaller (P < 0.05) head weight in fish of the flow-through system. Skin represented a significantly higher (P < 0.01) proportion of total weight in both RAS males and females. The most obvious difference was in the deposited fat weight, which was significantly higher (P < 0.01) in RAS fish. Visceral fat deposits were significantly higher (P < 0.01) in females and ventral and dorsal fat deposits higher (P > 0.05) in males.
Resumo:
Les organismes aquatiques sont adaptés à une grande variabilité hydrique et thermique des rivières. Malgré ceci, la régulation des eaux suscite des changements aux débits qui peuvent provoquer des impacts négatifs sur la biodiversité et les processus écologiques en rivière. Celle-ci peut aussi causer des modifications au niveau des régimes thermiques et des caractéristiques de l’habitat du poisson. Des données environnementales et biologiques décrivant l’habitat du poisson existent, mais elles sont incomplètes pour plusieurs rivières au Canada et de faible qualité, limitant les relations quantitatives débit-température-poissons à un petit nombre de rivières ou à une région étudiée. La recherche menée dans le cadre de mon doctorat concerne les impacts de la génération d'hydroélectricité sur les rivières; soit les changements aux régimes hydriques et thermiques reliés à la régulation des eaux sur la variation des communautés ichtyologiques qui habitent les rivières régulées et naturelles au Canada. Suite à une comparaison d’échantillonnage de pêche, une méthode constante pour obtenir des bons estimés de poisson (richesse, densité et biomasse des espèces) a été établie pour évaluer la structure de la communauté de poissons pour l’ensemble des rivières ciblées par l’étude. Afin de mieux comprendre ces changements environnementaux, les principales composantes décrivant ces régimes ont été identifiées et l’altération des régimes hydriques pour certaines rivières régulées a été quantifiée. Ces résultats ont servi à établir la relation significative entre le degré de changement biotique et le degré de changement hydrique pour illustrer les différences entre les régimes de régulation. Pour faire un complément aux indices biotiques déjà calculés pour l’ensemble des communautés de poissons (diversité, densité et biomasse des espèces par rivière), les différences au niveau des guildes de poissons ont été quantifiées pour expliquer les divers effets écologiques dus aux changements de régimes hydriques et thermiques provenant de la gestion des barrages. Ces derniers résultats servent à prédire pour quels traits écologiques ou groupes d’espèces de poissons les composantes hydriques et thermiques sont importantes. De plus, ces derniers résultats ont servi à mettre en valeur les variables décrivant les régimes thermiques qui ne sont pas toujours inclues dans les études hydro-écologiques. L’ensemble des résultats de cette thèse ont des retombées importantes sur la gestion des rivières en évaluant, de façon cohérente, l’impact de la régulation des rivières sur les communautés de poissons et en développant des outils de prévision pour la restauration des écosystèmes riverains.
Resumo:
Com a presente evolução das railguns na Marinha dos Estados Unidos da América e possível instalação em seus navios num futuro muito próximo, outras marinhas se seguirão. Creio que será do interesse da Marinha Portuguesa acompanhar esta evolução tecnológica, considerando as vantagens que advém da adoção deste tipo de armamento. Neste documento são abordados os princípios básicos subjacentes ao funcionamento da railgun, com principal foco nas questões eletrodinâmicas. Pretende-se adquirir familiaridade com este novo tipo de armamento através do estudo crítico dos seus princípios de funcionamento. O princípio básico de funcionamento de uma railgun, à primeira vista, parece bastante simples, à luz da aplicação imediata da expressão da força de Lorentz sobre um condutor percorrido por corrente elétrica. No entanto, tudo se torna mais complicado no caso de uma variação rápida dos parâmetros envolvidos (regime transitório), que exige uma análise mais aprofundada do comportamento da corrente, campos elétrico e magnético, e todos os materiais envolvidos neste sistema. Este trabalho envolveu ainda a construção de duas railguns, uma primeira de dimensões mais pequenas para ganhar familiaridade com o sistema, e uma última de dimensões de laboratório na qual foram feitos vários disparos para testar diferentes tipos de material e dimensões de projétil. Em suma, é demonstrado neste documento uma análise, no domínio do tempo, da distribuição espacial do campo eletromagnético, corrente elétrica e consequente fluxo de energia, complementados por uma parte experimental.
Resumo:
Tese (doutorado)–Universidade de Brasília, Instituto de Química, Programa de Pós-Graduação em Química, 2015.
Resumo:
The challenge for wastewater professionals is to design and operate treatment processes that support human well being and are environmentally sensitive throughout the life-cycle. This research focuses on one technology for small-scale wastewater treatment: the vertical flow constructed wetland (VFCW), which is herein investigated for the capacity to remove ammonium and nitrate nitrogen from wastewater. Hydraulic regime and presence/absence of vegetation are the basis for a three-phase bench scale experiment to determine oxygen transfer and nitrogen fate in VFCWs. Results show that 90% NH4+-N removal is achieved in aerobic downflow columns, 60% NO3--N removal occurs in anaerobic upflow columns, and 60% removal of total nitrogen can be achieved in downflow-upflow in-series. The experimental results are studied further using a variably saturated flow and reactive transport model, which allows a mechanistic explanation of the fate and transport of oxygen and nitrogen. The model clarifies the mechanisms of oxygen transport and nitrogen consumption, and clarifies the need for readily biodegradable COD for denitrification. A VFCW is then compared to a horizontal flow constructed wetland (HFCW) for life cycle environmental impacts. High areal emissions of greenhouse gases from VFCWs compared to HFCWs are the driver for the study. The assessment shows that because a VFCW is only 25% of the volume of an HFCW designed for the same treatment quality, the VFCW has only 25-30% of HFCW impacts over 12 impact categories and 3 damage categories. Results show that impacts could be reduced by design improvements. Design recommendations are downflow wetlands for nitrification, upflow wetlands for denitrification, series wetlands for total nitrogen removal, hydraulic load of 142 L/m2d, 30 cm downflow wetland depth, 1.0 m upflow wetland depth, recycle, vegetation and medium-grained sand. These improvements will optimize nitrogen removal, minimize gaseous emissions, and reduce wetland material requirements, thus reducing environmental impact without sacrificing wastewater treatment quality.
Resumo:
With favored offshore and downstream advection, the question of which physical mechanism may promote onshore transport of larvae in upwelling systems is of central interest. We have conducted a semi-realistic high resolution (0.25 km) numerical study of Lagrangian transports across the inner-shelf under upwelling-favorable wind forcing conditions, focusing on the shelf area of the Southwestern Portuguese coast, in the lee of Cape Sines. We add our findings to several years of biological observations of C. montagui, a planktonic species with higher recruitment during the upwelling peak timely with the daylight flood. Simulations cover a fifteen days period during the summer of 2006. We focused on Spring and Neap tide periods and observed upfront differences between simulations and the in situ observa- tions. However, the model is capable of representing the main dynamics of the region, namely the re- petitive character of the inner-shelf currents. We find that the cross-shore flow varies significantly in the daily cycle, and locally within a scale of a few kilometers in association with local topography and the presence of the cape. We consider the region immediately in the lee of the cape to be an upwelling shadow where the larvae became retained, and found that tidally tied migration proves beneficial for successful recruitment during the spring tides period. Our work suggested that the wind is not the only mechanism responsible for the daily variability of the cross-shore exchange. However, its sharp reversal at midday is critical for the advection of larvae towards the coast.
Resumo:
Rapidity-odd directed flow (v1) measurements for charged pions, protons, and antiprotons near midrapidity (y=0) are reported in sNN=7.7, 11.5, 19.6, 27, 39, 62.4, and 200 GeV Au+Au collisions as recorded by the STAR detector at the Relativistic Heavy Ion Collider. At intermediate impact parameters, the proton and net-proton slope parameter dv1/dy|y=0 shows a minimum between 11.5 and 19.6 GeV. In addition, the net-proton dv1/dy|y=0 changes sign twice between 7.7 and 39 GeV. The proton and net-proton results qualitatively resemble predictions of a hydrodynamic model with a first-order phase transition from hadronic matter to deconfined matter, and differ from hadronic transport calculations.
Resumo:
Response surface methodology based on Box-Behnken (BBD) design was successfully applied to the optimization in the operating conditions of the electrochemical oxidation of sanitary landfill leachate aimed for making this method feasible for scale up. Landfill leachate was treated in continuous batch-recirculation system, where a dimensional stable anode (DSA(©)) coated with Ti/TiO2 and RuO2 film oxide were used. The effects of three variables, current density (milliampere per square centimeter), time of treatment (minutes), and supporting electrolyte dosage (moles per liter) upon the total organic carbon removal were evaluated. Optimized conditions were obtained for the highest desirability at 244.11 mA/cm(2), 41.78 min, and 0.07 mol/L of NaCl and 242.84 mA/cm(2), 37.07 min, and 0.07 mol/L of Na2SO4. Under the optimal conditions, 54.99 % of chemical oxygen demand (COD) and 71.07 ammonia nitrogen (NH3-N) removal was achieved with NaCl and 45.50 of COD and 62.13 NH3-N with Na2SO4. A new kinetic model predicted obtained from the relation between BBD and the kinetic model was suggested.
Resumo:
We reported here for the first time that triboelectric charges on PET sheets can be used to seal and control the flow rate in paper-based devices. The proposed method exhibits simplicity and low cost, provides reversible sealing and minimizes the effect of sample evaporation.