1000 resultados para Transition Edge Sensors(TES)
Resumo:
Purpose: Precise needle puncture of the renal collecting system is an essential but challenging step for successful percutaneous nephrolithotomy. We evaluated the efficiency of a new real-time electromagnetic tracking system for in vivo kidney puncture. Materials and Methods: Six anesthetized female pigs underwent ureterorenoscopy to place a catheter with an electromagnetic tracking sensor into the desired puncture site and ascertain puncture success. A tracked needle with a similar electromagnetic tracking sensor was subsequently navigated into the sensor in the catheter. Four punctures were performed by each of 2 surgeons in each pig, including 1 each in the kidney, middle ureter, and right and left sides. Outcome measurements were the number of attempts and the time needed to evaluate the virtual trajectory and perform percutaneous puncture. Results: A total of 24 punctures were easily performed without complication. Surgeons required more time to evaluate the trajectory during ureteral than kidney puncture (median 15 seconds, range 14 to 18 vs 13, range 11 to 16, p ¼ 0.1). Median renal and ureteral puncture time was 19 (range 14 to 45) and 51 seconds (range 45 to 67), respectively (p ¼ 0.003). Two attempts were needed to achieve a successful ureteral puncture. The technique requires the presence of a renal stone for testing. Conclusions: The proposed electromagnetic tracking solution for renal collecting system puncture proved to be highly accurate, simple and quick. This method might represent a paradigm shift in percutaneous kidney access techniques
Resumo:
Purpose: Precise needle puncture of the renal collecting system is an essential but challenging step for successful percutaneous nephrolithotomy. We evaluated the efficiency of a new real-time electromagnetic tracking system for in vivo kidney puncture. Materials and Methods: Six anesthetized female pigs underwent ureterorenoscopy to place a catheter with an electromagnetic tracking sensor into the desired puncture site and ascertain puncture success. A tracked needle with a similar electromagnetic tracking sensor was subsequently navigated into the sensor in the catheter. Four punctures were performed by each of 2 surgeons in each pig, including 1 each in the kidney, middle ureter, and right and left sides. Outcome measurements were the number of attempts and the time needed to evaluate the virtual trajectory and perform percutaneous puncture. Results: A total of 24 punctures were easily performed without complication. Surgeons required more time to evaluate the trajectory during ureteral than kidney puncture (median 15 seconds, range 14 to 18 vs 13, range 11 to 16, p ¼ 0.1). Median renal and ureteral puncture time was 19 (range 14 to 45) and 51 seconds (range 45 to 67), respectively (p ¼ 0.003). Two attempts were needed to achieve a successful ureteral puncture. The technique requires the presence of a renal stone for testing. Conclusions: The proposed electromagnetic tracking solution for renal collecting system puncture proved to be highly accurate, simple and quick. This method might represent a paradigm shift in percutaneous kidney access techniques.
Resumo:
Cardinal Gracia's choice of India's first cardinal, had the approval of Nehru
Resumo:
In this paper we present an amorphous silicon device that can be used in two operation modes to measure the concentration of ions in solution. While crystalline devices present a higher sensitivity, their amorphous counterpart present a much lower fabrication cost, thus enabling the production of cheap disposable sensors for use, for example, in the food industry. The devices were fabricated on glass substrates by the PECVD technique in the top gate configuration, where the metallic gate is replaced by an electrolytic solution with an immersed Ag/AgCl reference electrode. Silicon nitride is used as gate dielectric enhancing the sensitivity and passivation layer used to avoid leakage and electrochemical reactions. In this article we report on the semiconductor unit, showing that the device can be operated in a light-assisted mode, where changes in the pH produce changes on the measured ac photocurrent. In alternative the device can be operated as a conventional ion selective field effect device where changes in the pH induce changes in the transistor's threshold voltage.
Resumo:
OBJECTIVE: Before the Aids pandemic, demographic transition and control programs prompted a shift in the age of incidence of tuberculosis from adults to older people in many countries. The objective of the study is to evaluate this transition in Brazil. METHODS: Tuberculosis incidence and mortality data from the Ministry of Health and population data from the Brazilian Bureau of Statistics were used to calculate age-specific incidence and mortality rates and medians. RESULTS: Among reported cases, the proportion of older people increased from 10.5% to 12% and the median age from 38 to 41 years between the period of 1986 and 1996. The smallest decrease in the incidence rate occurred in the 30--49 and 60+ age groups. The median age of death increased from 53 to 55 years between 1980 and 1996. The general decline in mortality rates from 1986 to 1991 became less evident in the 30+ age group during the period of 1991 to 1996. A direct correlation between age and mortality rates was observed. The largest proportion of bacteriologically unconfirmed cases occurred in older individuals. CONCLUSIONS: The incidence of tuberculosis has begun to shift to the older population. This shift results from the decline in the annual risk of infection as well as the demographic transition. An increase in reactivation tuberculosis in older people is expected, since this population will grow from 5% to 14% of the Brazilian population over the next 50 years. A progressive reduction in HIV-related cases in adults will most likely occur. The difficulty in diagnosing tuberculosis in old age leads to increased mortality.
Resumo:
The dusky grouper Epinephelus marginatus historically exploited by fisheries is a marine species showing slow growth, late maturation and protogynous hermaphroditism. Currently, it is considered as endangered by the IUCN. Therefore, it is essential to increase the knowledge about its biology and ecology to help conservation of this species. The present study reports the first record of a dusky grouper individual undergoing sexual transition, from female to male, in the Atlantic Ocean based on histological analyses of gonads. The specimen with total length: 770 mm; total weight: 8.1 kg and age: 21 years was captured in a rocky bottom along the coastline of the southernmost in Brazil.
Resumo:
Neste trabalho pretende-se introduzir os conceitos associados à lógica difusa no controlo de sistemas, neste caso na área da robótica autónoma, onde é feito um enquadramento da utilização de controladores difusos na mesma. Foi desenvolvido de raiz um AGV (Autonomous Guided Vehicle) de modo a se implementar o controlador difuso, e testar o desempenho do mesmo. Uma vez que se pretende de futuro realizar melhorias e/ou evoluções optou-se por um sistema modular em que cada módulo é responsável por uma determinada tarefa. Neste trabalho existem três módulos que são responsáveis pelo controlo de velocidade, pela aquisição dos dados dos sensores e, por último, pelo controlador difuso do sistema. Após a implementação do controlador difuso, procedeu-se a testes para validar o sistema onde foram recolhidos e registados os dados provenientes dos sensores durante o funcionamento normal do robô. Este dados permitiram uma melhor análise do desempenho do robô. Verifica-se que a lógica difusa permite obter uma maior suavidade na transição de decisões, e que com o aumento do número de regras é possível tornar o sistema ainda mais suave. Deste modo, verifica-se que a lógica difusa é uma ferramenta útil e funcional para o controlo de aplicações. Como desvantagem surge a quantidade de dados associados à implementação, tais como, os universos de discurso, as funções de pertença e as regras. Ao se aumentar o número de regras de controlo do sistema existe também um aumento das funções de pertença consideradas para cada variável linguística; este facto leva a um aumento da memória necessária e da complexidade na implementação pela quantidade de dados que têm de ser tratados. A maior dificuldade no projecto de um controlador difuso encontra-se na definição das variáveis linguísticas através dos seus universos de discurso e das suas funções de pertença, pois a definição destes pode não ser a mais adequada ao contexto de controlo e torna-se necessário efectuar testes e, consequentemente, modificações à definição das funções de pertença para melhorar o desempenho do sistema. Todos os aspectos referidos são endereçados no desenvolvimento do AGV e os respectivos resultados são apresentados e analisados.
Resumo:
New PVC membrane electrodes for the determination of sulfadiazine (SDZ) are presented. The electrodes are fabricated with conventional and tubular configurations with a graphite-based electrical contact, and no internal reference solution. The selective membranes consist of bis(triphenylphosphoranilidene)ammonium·SDZ (electrode A), tetraoctylammonium bromide (electrode B), or iron(II)-phthalocyanine (FePC) (electrode C) electroactive materials dispersed in a PVC matrix of o-nitrophenyl octyl ether (o-NPOE) plasticizer. The sensors A, B, and C displayed linear responses over the concentration ranges 1.0*10-2 – 1.0*10–5, 1.0*10–2 – 7.5*10–6, and 3.2*10–2 – 7.0* 10–6 mol l–1 (detection limits of 1.09, 2.04 and 0.87 mg ml–1) with anionic slopes of –57.3 ± 0.1, –46.7 ± 0.5, and –65.1 ± 0.2 mV decade–1, respectively. No effect from pH was observed within 4.0 – 5.5, 4.8 – 10, and 4.5 – 8, respectively, and good selectivity was found. The sensors were applied to the analysis of pharmaceuticals and biological fluids in steady state and in flow conditions.
Resumo:
A biomimetic sensor for norfloxacin is presented that is based on host-guest interactions and potentiometric transduction. The artificial host was imprinted into polymers made from methacrylic acid and/or 2-vinyl pyridine. The resulting particles were entrapped in a plasticized poly(vinyl chloride) (PVC) matrix. The sensors exhibit near-Nernstian response in steady state evaluations, and detection limits range from 0.40 to 1.0 μgmL−1, respectively, and are independent of pH values at between 2 and 6, and 8 and 11, respectively. Good selectivity was observed over several potential interferents. In flowing media, the sensors exhibit fast response, a sensitivity of 68.2 mV per decade, a linear range from 79 μM to 2.5 mM, a detection limit of 20 μgmL−1, and a stable baseline. The sensors were successfully applied to field monitoring of norfloxacin in fish samples, biological samples, and pharmaceutical products
Resumo:
New potentiometric membrane sensors with cylindrical configuration for tetracycline (TC) are described based on the use of a newly designed molecularly imprinted polymer (MIP) material consisting of 2-vinylpyridine as a functional monomer in a plasticized PVC membrane. The sensor exhibited significantly enhanced response towards TC over the concentration range 1.59 10 5–1.0 10 3 mol L 1 at pH 3–5 with a lower detection limit of 1.29 10 5 mol L 1. The response was near-Nernstian, with average slopes of 63.9 mV decade 1. The effect of lipophilic salts and various foreign common ions were tested and were found to be negligible. The possibility of applying the proposed sensor to TC determination in spiked biological fluid samples was demonstrated.
Resumo:
The deterioration of water quality by Cyanobacteria cause outbreaks and epidemics associated with harmful diseases in Humans and animals because of the toxins that they release. Microcystin-LR is one of the hepatotoxins most widely studied and the World Health Organization, recommend a maximum value of 1mgL 1 in drinking water. Highly specific recognition molecules, such as molecular imprinted polymers are developed to quantify microcystins in waters for human use and shown to be of great potential in the analysis of these kinds of samples. The obtained results were auspicious, the detection limit found, 1.5mgL 1, being of the same order of magnitude as the guideline limit recommended by the WHO. This technology is very promising because the sensors are stable and specific, and the technology is inexpensive and allows for rapid on-site monitoring.
Resumo:
Molecularly imprinted polymers (MIP) were used as potentiometric sensors for the selective recognition and determination of chlormequat (CMQ). They were produced after radical polymerization of 4-vinyl pyridine (4-VP) or methacrylic acid (MAA) monomers in the presence of a cross-linker. CMQwas used as template. Similar nonimprinted (NI) polymers (NIP) were produced by removing the template from reaction media. The effect of kind and amount of MIP or NIP sensors on the potentiometric behavior was investigated. Main analytical features were evaluated in steady and flow modes of operation. The sensor MIP/4-VP exhibited the best performance, presenting fast near-Nernstian response for CMQover the concentration range 6.2×10-6 – 1.0×10-2 mol L-1 with detection limits of 4.1×10-6 mol L-1. The sensor was independent from the pH of test solutions in the range 5 – 10. Potentiometric selectivity coefficients of the proposed sensors were evaluated over several inorganic and organic cations. Results pointed out a good selectivity to CMQ. The sensor was applied to the potentiometric determination of CMQin commercial phytopharmaceuticals and spiked water samples. Recoveries ranged 96 to 108.5%.
Resumo:
The 41 years of armed conflict (1961 to 2002) resulted in a poor development of the health care and education infrastructures, and forced the relocation of people to safer places, namely major urban cities like Luanda. This phase was characterized by typical demographic, nutritional and epidemiological profiles. With the end of this period Angola has been repeatedly ranked as one of the three fastest growing economies in the world, and along with the social stabilization and globalization, the country is facing the introduction of new medical technologies, improvement of health sys-tems and services, better access to them, and overall better quality of life. These changes could also be translating into socio-cultural, demographic and nutritional changes which in turn may leading to changes in the epidemiological profile of the country. Thus, the emergence of non-communicable diseases are likely to become an increasingly im-portant public health problem in Angola. Also, considering that several infectious diseases persist, our weakened health system will have to face a double burden. Thus, disease surveillance data on non-communicable diseases to determine their prevalence and impact, along with the major behavioural risk factors like consumption of tobacco, alcohol, diets and physical inactivity are urgently needed.
Resumo:
To counteract and prevent the deleterious effect of free radicals the living organisms have developed complex endogenous and exogenous antioxidant systems. Several analytical methodologies have been proposed in order to quantify antioxidants in food, beverages and biological fluids. This paper revises the electroanalytical approaches developed for the assessment of the total or individual antioxidant capacity. Four electrochemical sensing approaches have been identified, based on the direct electrochemical detection of antioxidant at bare or chemically modified electrodes, and using enzymatic and DNA-based biosensors.
Resumo:
A new man-tailored biomimetic sensor for Chlorpromazine host-guest interactions and potentiometric transduction is presented. The artificial host was imprinted within methacrylic acid, 2-vinyl pyridine and 2-acrylamido-2-methyl-1-propanesulfonic acid based polymers. Molecularly imprinted particles were dispersed in 2-nitrophenyloctyl ether and entrapped in a poly(vinyl chloride) matrix. Slopes and detection limits ranged 51–67 mV/decade and 0.46–3.9 μg/mL, respectively, in steady state conditions. Sensors were independent fromthe pHof test solutionswithin 2.0–5.5.Good selectivitywas observed towards oxytetracycline, doxytetracycline, ciprofloxacin, enrofloxacin, nalidixic acid, sulfadiazine, trimethoprim, glycine, hydroxylamine, cysteine and creatinine. Analytical features in flowing media were evaluated on a double-channel manifold, with a carrier solution of 5.0×10−2 mol/L phosphate buffer. Near-Nernstian response was observed over the concentration range 1.0×10−4 to 1.0×10−2 mol/L. Average slopes were about 48 mV/decade. The sensors were successfully applied to field monitoring of CPZ in fish samples, offering the advantages of simplicity, accuracy, automation feasibility and applicability to complex samples.