889 resultados para Traffic Control Signals.


Relevância:

80.00% 80.00%

Publicador:

Resumo:

A major 3-year research project to improve safety at roadworks has recently been completed by the Centre for Accident Research and Road Safety – Queensland (CARRS-Q) and industry partners. This project involved developing strategies to mitigate roadwork hazards including speeding. This paper presents three on-road evaluation studies on the effectiveness of some current and new safety treatments: use of pilot vehicles, variable message signage (VMS), police enforcement with and without VMS, and remote-controlled traffic control devices. The speed reduction potential of pilot vehicles was evaluated at a highway site. Results showed that pilot vehicles reduced average speeds within the work area, but not at a downstream location. Combinations of VMS and police enforcement were evaluated at a motorway site and results showed that police enforcement accompanied with VMS had greater effects on reducing speeds than either of these treatments alone. Three new remote-controlled traffic control devices—red and amber lights, red light and amber arrow, and a robotic stop/slow sign—were evaluated at a highway site. Results showed that the red light and amber arrow option produced consistent effects on the speeds at the approach to traffic controls and at a location inside the work area. This paper presents the first rigorous evaluations of these roadwork safety treatments in Queensland.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Circuits for realizing serial quaternary-to-analogue converters (QACs) are proposed in this paper. Three techniques are presented based on Shannon-Rack decoder, sample/hold serial digital-to-analogue converter and cyclic digital-to-analogue converter. Circuits for the generation of control signals and the multiplexer required in the realization of the QACs are also described. A comparison of the three methods is made.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The third edition of the Australian Standard AS1742 Manual of Uniform Traffic Control Devices Part 7 provides a method of calculating the sighting distance required to safely proceed at passive level crossings based on the physics of moving vehicles. This required distance becomes greater with higher line speeds and slower, heavier vehicles so that it may return quite a long sighting distance. However, at such distances, there are also concerns around whether drivers would be able to reliably identify a train in order to make an informed decision regarding whether it would be safe to proceed across the level crossing. In order to determine whether drivers are able to make reliable judgements to proceed in these circumstances, this study assessed the distance at which a train first becomes identifiable to a driver as well as their, ability to detect the movement of the train. A site was selected in Victoria, and 36 participants with good visual acuity observed 4 trains in the 100-140 km/h range. While most participants could detect the train from a very long distance (2.2 km on average), they could only detect that the train was moving at much shorter distances (1.3 km on average). Large variability was observed between participants, with 4 participants consistently detecting trains later than other participants. Participants tended to improve in their capacity to detect the presence of the train with practice, but a similar trend was not observed for detection of the movement of the train. Participants were consistently poor at accurately judging the approach speed of trains, with large underestimations at all investigated distances.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

With the rapid development of photovoltaic system installations and increased number of grid connected power systems, it has become imperative to develop an efficient grid interfacing instrumentation suitable for photovoltaic systems ensuring maximum power transfer. The losses in the power converter play an important role in the overall efficiency of a PV system. Chain cell converter is considered to be efficient as compared to PWM converters due to lower switching losses, modularized circuit layout, reduced voltage rating of the converter switches, reduced EMI. The structure of separate dc sources in chain cell converter is well suited for photovoltaic systems as there will b several separate PV modules in the PV array which can act as an individual dc source. In this work, a single phase multilevel chain cell converter is used to interface the photovoltaic array to a single phase grid at a frequency of 50Hz. Control algorithms are developed for efficient interfacing of the PV system with grid and isolating the PV system from grid under faulty conditions. Digital signal processor TMS320F 2812 is used to implement the control algorithms developed and for the generation of other control signals.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Torsional interactions can occur due to the speed input Power System Stabilizer (PSS) that are primarily used to damp low frequency oscillations. The solution to this problem can be either in the form of providing a torsional filter or developing an alternate signal for the PSS. This paper deals with the formulation of a linearized state space model of the system and study of the interactions using eigenvalue analysis. The effects of the parameters of PSS and control signals on the damping of torsional modes are investigated.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Vehicular ad hoc network (VANET) applications are principally categorized into safety and commercial applications. Efficient traffic management for routing an emergency vehicle is of paramount importance in safety applications of VANETs. In the first case, a typical example of a high dense urban scenario is considered to demonstrate the role of penetration ratio for achieving reduced travel time between source and destination points. The major requirement for testing these VANET applications is a realistic simulation approach which would justify the results prior to actual deployment. A Traffic Simulator coupled with a Network Simulator using a feedback loop feature is apt for realistic simulation of VANETs. Thus, in this paper, we develop the safety application using traffic control interface (TraCI), which couples SUMO (traffic simulator) and NS2 (network simulator). Likewise, the mean throughput is one of the necessary performance measures for commercial applications of VANETs. In the next case, commercial applications have been considered wherein the data is transferred amongst vehicles (V2V) and between roadside infrastructure and vehicles (I2V), for which the throughput is assessed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Intra-aortic balloon pumping is a counter pulsation technique for temporary circulatory assistance in cardiogenic shock and other low cardiac output conditions. Conventional systems use a balloon at the end of a catheter driven by a solenoid valve, controlled by patient's ECG or ventricular pressure signal. This results in time delay introducted by solenoid spool inertia, gas inertia, and hysteresis effects of the solenoid. Fluidics, because of their non-moving part operation and high switching speeds, minimizes the inertial effects while contributing high reliability. This communication describes a fluidic system developed for driving the balloon accepting electric control signals.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this paper we propose a fully parallel 64K point radix-4(4) FFT processor. The radix-4(4) parallel unrolled architecture uses a novel radix-4 butterfly unit which takes all four inputs in parallel and can selectively produce one out of the four outputs. The radix-4(4) block can take all 256 inputs in parallel and can use the select control signals to generate one out of the 256 outputs. The resultant 64K point FFT processor shows significant reduction in intermediate memory but with increased hardware complexity. Compared to the state-of-art implementation 5], our architecture shows reduced latency with comparable throughput and area. The 64K point FFT architecture was synthesized using a 130nm CMOS technology which resulted in a throughput of 1.4 GSPS and latency of 47.7 mu s with a maximum clock frequency of 350MHz. When compared to 5], the latency is reduced by 303 mu s with 50.8% reduction in area.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We present a new Hessian estimator based on the simultaneous perturbation procedure, that requires three system simulations regardless of the parameter dimension. We then present two Newton-based simulation optimization algorithms that incorporate this Hessian estimator. The two algorithms differ primarily in the manner in which the Hessian estimate is used. Both our algorithms do not compute the inverse Hessian explicitly, thereby saving on computational effort. While our first algorithm directly obtains the product of the inverse Hessian with the gradient of the objective, our second algorithm makes use of the Sherman-Morrison matrix inversion lemma to recursively estimate the inverse Hessian. We provide proofs of convergence for both our algorithms. Next, we consider an interesting application of our algorithms on a problem of road traffic control. Our algorithms are seen to exhibit better performance than two Newton algorithms from a recent prior work.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Radar services are occasionally affected by wind farms. This paper presents a comprehensive description of the effects that a wind farm may cause on the different radar services, and it compiles a review of the recent research results regarding the mitigation techniques to minimize this impact. Mitigation techniques to be applied at the wind farm and on the radar systems are described. The development of thorough impact studies before the wind farm is installed is presented as the best way to analyze in advance the potential for interference, and subsequently identify the possible solutions to allow the coexistence of wind farms and radar services.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This thesis presents a biologically plausible model of an attentional mechanism for forming position- and scale-invariant representations of objects in the visual world. The model relies on a set of control neurons to dynamically modify the synaptic strengths of intra-cortical connections so that information from a windowed region of primary visual cortex (Vl) is selectively routed to higher cortical areas. Local spatial relationships (i.e., topography) within the attentional window are preserved as information is routed through the cortex, thus enabling attended objects to be represented in higher cortical areas within an object-centered reference frame that is position and scale invariant. The representation in V1 is modeled as a multiscale stack of sample nodes with progressively lower resolution at higher eccentricities. Large changes in the size of the attentional window are accomplished by switching between different levels of the multiscale stack, while positional shifts and small changes in scale are accomplished by translating and rescaling the window within a single level of the stack. The control signals for setting the position and size of the attentional window are hypothesized to originate from neurons in the pulvinar and in the deep layers of visual cortex. The dynamics of these control neurons are governed by simple differential equations that can be realized by neurobiologically plausible circuits. In pre-attentive mode, the control neurons receive their input from a low-level "saliency map" representing potentially interesting regions of a scene. During the pattern recognition phase, control neurons are driven by the interaction between top-down (memory) and bottom-up (retinal input) sources. The model respects key neurophysiological, neuroanatomical, and psychophysical data relating to attention, and it makes a variety of experimentally testable predictions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The dynamic interaction of limb segments during movements that involve multiple joints creates torques in one joint due to motion about another. Evidence shows that such interaction torques are taken into account during the planning or control of movement in humans. Two alternative hypotheses could explain the compensation of these dynamic torques. One involves the use of internal models to centrally compute predicted interaction torques and their explicit compensation through anticipatory adjustment of descending motor commands. The alternative, based on the equilibrium-point hypothesis, claims that descending signals can be simple and related to the desired movement kinematics only, while spinal feedback mechanisms are responsible for the appropriate creation and coordination of dynamic muscle forces. Partial supporting evidence exists in each case. However, until now no model has explicitly shown, in the case of the second hypothesis, whether peripheral feedback is really sufficient on its own for coordinating the motion of several joints while at the same time accommodating intersegmental interaction torques. Here we propose a minimal computational model to examine this question. Using a biomechanics simulation of a two-joint arm controlled by spinal neural circuitry, we show for the first time that it is indeed possible for the neuromusculoskeletal system to transform simple descending control signals into muscle activation patterns that accommodate interaction forces depending on their direction and magnitude. This is achieved without the aid of any central predictive signal. Even though the model makes various simplifications and abstractions compared to the complexities involved in the control of human arm movements, the finding lends plausibility to the hypothesis that some multijoint movements can in principle be controlled even in the absence of internal models of intersegmental dynamics or learned compensatory motor signals.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper presents an improvement of an IGBT gate drive implementing Active Voltage Control (AVC), and investigates the impact of various parameters affecting its performance. The effects of the bandwidths of various elements and the gains of AVC are shown in simulation and experimentally. Also, the paper proposes connecting a small Active Snubber between the IGBT collector and its gate integrated within the AVC. The effect of this snubber on enhancing the stability of the gate drive is demonstrated. It will be shown that using a wide bandwidth operational amplifier and integrating the Active Snubber within the gate drive reduces the minimum gate resistor required to achieve stability of the controller. Consequently, the response time of the IGBT to control signals is significantly reduced, the switching losses then can be minimised and, hence, the performance of gate drive as whole is improved. This reflects positively on turn-off and turn-on transitions achieving voltage sharing between the IGBTs connected in series to construct a higher voltage switch, making series IGBTs a feasible practice. ©2008 IEEE.