960 resultados para Tomografia computadorizada - odontologia
Resumo:
Introduction: This study aimed to evaluate the close proximity established between the maxillary sinus floor and posterior teeth roots apices by using cone-beam computed tomographic scanning. Methods: The relationship of maxillary sinuses and posterior teeth roots, which were divided into 2 groups, was analyzed using i-CAT Vision software (Imaging Sciences, Hatfield, PA). Group 1 included all root apices found in close contact with the maxillary sinus floor without sinus floor elevation, whereas group 2 included all root apices that were protruded within the sinus producing an elevation of the bony cortical. Results: A total of 100 maxillary sinuses and 601 roots apices were evaluated. Group 1 presented 130 of 601 (21.6%) roots and group 2 presented 86 of 601 (14.3%) roots. Conclusions: The second molar mesiobuccal root apex is frequently found in close proximity with the sinus floor, and the relation between these anatomic structures should be considered in order to prevent an iatrogenic procedure and minimize the risks from an infectious disease within the sinus
Resumo:
A doença cardiovascular representa a principal causa de mortalidade no mundo. A capacidade de identificar, dentre os indivíduos assintomáticos, o subgrupo que apresenta maior risco de desenvolver eventos cardiovasculares no futuro representa uma etapa fundamental em qualquer estratégia voltada para a diminuição da taxas de eventos cardiovasculares. O primeiro passo na estratificação do risco cardiovascular é a utilização dos "escores de risco global", dentre os quais o mais frequentemente utilizado é o escore de Framingham. Entretanto, estudos prévios demonstraram que embora muito úteis, os escores clínicos, quando utilizados isoladamente, apresentam capacidade limitada de estratificação do risco cardiovascular em uma parcela significativa da população. É nesse contexto que o escore de cálcio (EC) coronariano e a angiotomografia das artérias coronárias podem desempenhar papel importante como ferramentas complementares na estratificação de risco dos pacientes assintomáticos. O EC coronariano proporciona importantes informações prognósticas que são incrementais aos escores clínicos baseados nos fatores de risco tradicionais e a outras modalidades diagnósticas, como a dosagem da proteína C reativa, por exemplo. Além disso, o EC também tem o potencial de alterar a conduta e auxiliar no manejo clínico dos pacientes. Já a angiotomografia coronariana proporciona avaliação detalhada da anatomia das artérias coronárias, permitindo visualizar não apenas o lúmen, mas também as paredes arteriais coronarianas. Comparada à coronariografia invasiva convencional, a angiotomografia apresenta excelente acurácia para identificar e, principalmente, excluir a presença de lesões obstrutivas significativas. Adicionalmente, demonstrou-se capaz de proporcionar informações prognósticas incrementais aos fatores de risco tradicionais e ao EC coronariano.
Resumo:
O termo gossipiboma é usado para descrever uma massa formada a partir de uma matriz de algodão cercada por uma reação inflamatória/granulomatosa. Sua incidência é estimada em 0,15% a 0,2%. O corpo estranho na cavidade abdominal pode servir de nicho para a proliferação de microrganismos e agir como foco primário para formação de abscessos e de peritonite. Vários estudos têm demonstrado a importância da correlação clínica com os diversos métodos de imagem (radiografia convencional, ultrassonografia, tomografia computadorizada e ressonância magnética) no diagnóstico dos gossipibomas. Este ensaio tem por objetivo demonstrar uma série de casos típicos de gossipibomas abdominais e ilustrar suas diversas formas de apresentação, com ênfase nos achados dos diferentes métodos de imagem, visando a familiarizar os radiologistas com esta enfermidade e seus principais diagnósticos diferenciais.
Resumo:
OBJETIVO: Descrever os principais achados de imagem em uma série de casos de tumores neuroendócrinos primários do pulmão (TNPs), destacando as alterações na tomografia computadorizada. MATERIAIS E MÉTODOS: Exames de 22 pacientes (12 homens, idade média de 60 anos) avaliados nos últimos cinco anos em nosso serviço, com confirmação histopatológica, foram retrospectivamente revistos por dois médicos radiologistas e os achados foram descritos em consenso, focando as alterações tomográficas. RESULTADOS: Descrevemos 5 carcinoides típicos, 3 carcinoides atípicos, 3 carcinomas neuroendócrinos de grandes células (CNGCs) e 11 cânceres pulmonares de pequenas células (CPPCs). Apenas um carcinoide típico apresentou aspecto característico de nódulo endobrônquico central com atelectasia pulmonar distal, enquanto os demais foram nódulos ou massas pulmonares. Os carcinoides atípicos eram massas pulmonares periféricas e heterogêneas. Um CNGC era massa periférica delimitada e homogênea, enquanto os demais eram mal delimitados e heterogêneos. Os 11 CPPCs eram massas centrais, infiltrativas e heterogêneas, com alterações pleuropulmonares secundárias. Calcificações estavam ausentes nos CNGCs e CPPCs. Metástases foram vistas inicialmente ou no seguimento de todos os CNGCs e CPPCs. CONCLUSÃO: Apesar de alguns aspectos semelhantes nos exames de imagem, os achados radiológicos, quando integrados às informações clínicas, podem constituir critérios importantes na diferenciação dos tipos histológicos de TNPs.
Resumo:
Tumores miofibroblásticos inflamatórios raramente acometem vias urinárias ou crianças, comumente mimetizando neoplasias malignas nos exames de imagem. Foram descritos apenas 35 casos desses tumores na bexiga de crianças, segundo a literatura recente. Os autores apresentam o caso de uma criança com um tumor miofibroblástico vesical que evoluiu favoravelmente após ressecção cirúrgica completa.
Resumo:
Relatamos o caso de uma mulher de 21 anos com história de seis meses de dispneia progressiva, tosse seca e perda de peso. A tomografia computadorizada de alta resolução revelou padrão de pavimentação em mosaico com áreas focais poupadas. A paciente foi submetida a biópsia pulmonar transbrônquica, que confirmou o diagnóstico de proteinose alveolar. Dois anos depois, sem tratamento, houve importante melhora das opacidades pulmonares.
Resumo:
OBJETIVO: Avaliar a PET/CT na abordagem de pacientes com câncer de cabeça e pescoço. MATERIAIS E MÉTODOS: Estudo retrospectivo de 63 prontuários e exames de PET/CT de pacientes com câncer de cabeça e pescoço. RESULTADOS: Foram encontradas alterações em 76% dos exames. Destes, 7 (11%) foram considerados falso-positivos, com SUV < 5,0. A PET/CT mostrou-se negativa em 15 situações (24%). Dos 14 casos nos quais se utilizou o exame para estadiamento, em 3 (22%) houve aumento no estadiamento. CONCLUSÃO: A PET/CT mostra-se como exame de potencial valor na rotina de avaliação de pacientes com câncer de cabeça e pescoço, entretanto, necessitamos de maior número de casos para definirmos protocolo de uso.
Resumo:
OBJETIVO: Estudo anatômico do áxis através de tomografia computadorizada (TC) em crianças de dois a dez anos de idade, mensurando a angulação das lâminas, espessura e comprimento de lâminas e pedículos e espessura da massa lateral. MÉTODOS: Estudou-se 64 TCs da coluna cervical de indivíduos com idades entre 24 e 120 meses, de ambos os sexos e sem deformidades cervicais. Correlacionaram-se as variáveis estudadas com os grupos etários e sexo dos pacientes. A análise estatística foi realizada por meio do teste t. RESULTADOS: Verificou-se que na faixa etária entre 24-48 meses, 5,5% das lâminas e 8,3% dos pedículos possuem espessura menores do que 3,5mm, espessura necessária para colocação de um parafuso. Entre 49-120 meses não há lâminas com espessuras menores do que 3,5mm e 1,2% dos pedículos possuem espessura menor do que 3,5mm. Em ambos os grupos etários não há comprimento de lâminas e pedículos menores do que 12 mm e massas laterais maiores do que 12 mm. CONCLUSÃO: A análise das dimensões obtidas no estudo permite, na maioria dos casos, a colocação de parafusos de 3,5mm nas lâminas e pedículos do áxis de crianças. Nível de Evidência II, Desenvolvimento de critérios diagnósticos em pacientes consecutivos.
Resumo:
OBJECTIVE: To evaluate tools for the fusion of images generated by tomography and structural and functional magnetic resonance imaging. METHODS: Magnetic resonance and functional magnetic resonance imaging were performed while a volunteer who had previously undergone cranial tomography performed motor and somatosensory tasks in a 3-Tesla scanner. Image data were analyzed with different programs, and the results were compared. RESULTS: We constructed a flow chart of computational processes that allowed measurement of the spatial congruence between the methods. There was no single computational tool that contained the entire set of functions necessary to achieve the goal. CONCLUSION: The fusion of the images from the three methods proved to be feasible with the use of four free-access software programs (OsiriX, Register, MRIcro and FSL). Our results may serve as a basis for building software that will be useful as a virtual tool prior to neurosurgery.
Resumo:
O tumor odontogênico cístico calcificante normalmente se manifesta como uma massa indolor, de crescimento lento, que acomete tanto a maxila como a mandíbula, tendo predileção pelo segmento anterior (área dos incisivos e caninos). Geralmente, ocorre em adultos jovens, na terceira a quarta década de vida, sem preferência por gênero. Imagens de tomografia computadorizada revelaram características importantes não detectadas na radiografia panorâmica, tais como fenestração, calcificação e estruturas dentiformes. A característica microscópica típica dessa lesão é a presença de células epiteliais aberrantes anucleadas, em quantidades variáveis, denominadas "células fantasmas". Também se pode encontrar dentina displásica e, ocasionalmente, os cistos estão associados a tecido dentário duro, semelhante ao odontoma. O tratamento do tumor odontogênico cístico calcificante incluiu simples enucleação e curetagem. O objetivo deste trabalho foi mostrar duas manifestações diferentes do tumor odontogênico cístico calcificante, em que a tomografia computadorizada, associada às características clínicas, foi ferramenta importante para o diagnóstico, o planejamento cirúrgico e o acompanhamento dos pacientes.
Resumo:
Background: Few data on the definition of simple robust parameters to predict image noise in cardiac computed tomography (CT) exist. Objectives: To evaluate the value of a simple measure of subcutaneous tissue as a predictor of image noise in cardiac CT. Methods: 86 patients underwent prospective ECG-gated coronary computed tomographic angiography (CTA) and coronary calcium scoring (CAC) with 120 kV and 150 mA. The image quality was objectively measured by the image noise in the aorta in the cardiac CTA, and low noise was defined as noise < 30HU. The chest anteroposterior diameter and lateral width, the image noise in the aorta and the skin-sternum (SS) thickness were measured as predictors of cardiac CTA noise. The association of the predictors and image noise was performed by using Pearson correlation. Results: The mean radiation dose was 3.5 ± 1.5 mSv. The mean image noise in CT was 36.3 ± 8.5 HU, and the mean image noise in non-contrast scan was 17.7 ± 4.4 HU. All predictors were independently associated with cardiac CTA noise. The best predictors were SS thickness, with a correlation of 0.70 (p < 0.001), and noise in the non-contrast images, with a correlation of 0.73 (p < 0.001). When evaluating the ability to predict low image noise, the areas under the ROC curve for the non-contrast noise and for the SS thickness were 0.837 and 0.864, respectively. Conclusion: Both SS thickness and CAC noise are simple accurate predictors of cardiac CTA image noise. Those parameters can be incorporated in standard CT protocols to adequately adjust radiation exposure.
Resumo:
O documento IAEA/TRS 457 [1] define qualidades de radiação para calibração de detectores utilizados em mediações na área de radiologia diagnóstica. O documento define qualidades específicas para feixes primários (RQR), transmitidos (RQA), bem como outros específicos para mamografia e tomografia computadorizada. Estas qualidades devem ser estabelecidas de acordo com a norma IEC 61267. O presente trabalho descreve a validação dos filtros de qualidade de radiação RQR, previamente estabelecidos, a determinação de filtros com qualidade de radiação RQA e a determinação das curvas de atenuação para ambos os casos.
Resumo:
O biótipo gengival, definido como a espessura da gengiva no sentido vestíbulo-lingual, desempenha importante papel na homeostasia dos tecidos periodontais, podendo ser considerado um preditor no sucesso em longo prazo das terapias periodontais e periimplantares. Assim sendo, é de suma importância reconhecer as dimensões do tecido gengival e as diferentes formas de qualificá-lo e principalmente quantificá-lo. Apesar de haver descrito na literatura inúmeros métodos para este fim, existem poucos estudos comparando a efetividade de um método em relação a outro. Desta maneira, este estudo buscou avaliar se há concordância entre avaliações clínicas e tomográficas na classificação do biótipo gengival, se existe correlação entre o biótipo gengival e a espessura óssea subjacente, além de descrever um novo método de tomada tomográfica que permita a análise quantitativa do biótipo gengival. Foram avaliados 12 indivíduos os quais realizaram tomografias computadorizadas de feixe cônico como exame imaginológico de diagnóstico ou planejamento pré-cirúrgico. Em cada paciente foram realizados quatro diferentes métodos de avaliação qualitativa da espessura gengival (transparência a sondagem, transgengival, visual através de fotografia e tomográfico), dois métodos de avaliação quantitativa (transgengival e tomográfico) da espessura gengival e avaliação da espessura óssea através da tomografia computadorizada de feixe cônico. Os resultados foram avaliados estatisticamente através do teste KAPPA, Teste t pareado e coeficiente de correlação de Pearson (pM0.05). O novo método de tomada tomográfica descrito neste estudo é eficaz para avaliação do biótipo gengival, havendo grande concordância (86,1% Kappa 0,51) e forte correlação (r=0,824) entre ele e o método transgengival (padrão ouro). A correlação entre a espessura óssea e a espessura gengival foi moderada quando utilizado o método transgengival e tomográfico (r=0,567 e r=0,653 respectivamente).
Resumo:
A qualidade óssea, bem como a estabilidade inicial dos implantes, está diretamente relacionada com o sucesso das reabilitações na implantodontia. O presente estudo teve como objetivo analisar a correlação entre índices radiomorfométricos de densidade óssea por meio de radiografias panorâmicas, perfil de qualidade óssea com o auxílio de Tomografia Computadorizada de Feixe Cônico (TCFC) com o uso do software de imagens OsiriX, Análise da Frequência de Ressonância (RFA) e Torque de Inserção do implante. Foram avaliados 160 implantes de 72 indivíduos, com média etária de 55,5 (±10,5) anos. Nas radiografias panorâmicas foram obtidos os índices IM, IPM e ICM, e nas tomografias computadorizadas de feixe cônico, os valores de pixels e a espessura da cortical da crista óssea alveolar, além da estabilidade primária por meio do torque de inserção e análise da frequência de ressonância. Os resultados foram analisados pelo coeficiente de correlação de Spearman, para p<= 0,01 foi obtido entre o torque de inserção e valores de pixels (0.330), o torque de inserção e a espessura da cortical da crista alveolar (0.339), o torque de inserção e o ISQ vestibulo-lingual (0.193), os valores de pixels e espessura da cortical da crista alveolar (0.377), as duas direções vestíbulo-lingual e mesio-distal do ISQ (0.674), o ISQ vestíbulo-lingual e a espessura da cortical da crista alveolar (0.270); os índices radiomorfométricos foram correlacionados entre eles e para p<= 0,05 foi obtido entre torque de inserção e ISQ mesio-distal (0.131), entre o ISQ vestibulo-lingual e os valores de pixels (0.156) e ISQ mesio-distal e IPMI esquerdo (0.149) e ISQ mesio-distal e IPMS esquerdo (0.145). Existe correlação entre a TCFC, o torque de inserção e a RFA na avaliação da qualidade óssea. É possível utilizar, pré-cirurgicamente, os exames de TCFC para avaliar a qualidade e quantidade óssea, tendo em vista as correlações obtidas neste estudo.
Resumo:
A esteatose hepática, que se caracteriza pelo acúmulo excessivo de gordura nas células do fígado, é um problema que vem preocupando a comunidade médico-científica, pois sua incidência vem aumentando a nível global, com expectativa de se tornar a doença crônica hepática de maior predominância em várias partes do mundo. Apesar de ser considerada uma doença benigna, a esteatose pode evoluir para doenças mais graves como cirrose, fibrose avançada, esteato hepatite (com ou sem fibrose) ou carcinoma. Entretanto, é potencialmente reversível, mesmo em quadros mais graves, o que reforça a urgência de se desenvolver métodos confiáveis para detecção e avaliação, inclusive ao longo de tratamento. Os métodos atuais para diagnóstico e quantificação da gordura hepática ainda são falhos: com a ultrassonografia não se é capaz de realizar quantificação; a tomografia computadorizada faz uso de radiação ionizante; a punção (biópsia), considerada o padrão ouro, é precisa, mas invasiva e pontual. A Ressonância Magnética (RM), tanto com espectroscopia (MRS) como com imagem (MRI), são alternativas completamente não invasivas, capazes de fornecer o diagnóstico e quantificação da gordura infiltrada no fígado. Entretanto, os trabalhos encontrados na literatura utilizam sequências de pulsos desenvolvidas especialmente para esse fim, com métodos de pós-processamento extremamente rebuscados, o que não é compatível com o estado atual dos equipamentos encontrados em ambientes clínicos nem mesmo ao nível de experiência e conhecimento das equipes técnicas que atuam em clínicas de radiodiagnóstico. Assim, o objetivo central do presente trabalho foi avaliar o potencial da RM como candidato a método de diagnóstico e de quantificação de gordura em ambientes clínicos, utilizando, para isso, sequências de pulsos convencionais, disponíveis em qualquer sistema comercial de RM, com protocolos de aquisição e processamento compatíveis com àqueles realizados em exames clínicos, tanto no que se refere à simplicidade como ao tempo total de aquisição. Foram avaliadas diferentes abordagens de MRS e MRI utilizando a biópsia hepática como padrão de referência. Foram avaliados pacientes portadores de diabetes tipo II, que apresentam alta prevalência de esteatose hepática não alcoólica, além de grande variabilidade nos percentuais de gordura. Foram realizadas medidas de correlação, acurácia, sensibilidade e especificidade de cada uma das abordagens utilizadas. Todos os métodos avaliados apresentaram alto grau de correlação positiva (> 87%) com os dados obtidos de maneira invasiva, o que revela que os valores obtidos utilizando RM estão de acordo com aquilo observado pela biópsia hepática. Muito embora os métodos de processamento utilizados não sejam tão complexos quanto seriam necessários caso uma quantificação absoluta fosse desejada, nossas análises mostraram alta acurácia, especificidade e sensibilidade da RM na avaliação da esteatose. Em conclusão, a RM se apresenta, de fato, como uma excelente candidata para avaliar, de forma não invasiva, a fração de gordura hepática, mesmo quando se considera as limitações impostas por um ambiente clínico convencional. Isso sugere que essas novas metodologias podem começar a migrar para ambientes clínicos sem depender das sequências complexas e dos processamentos exóticos que estão descritos na literatura mais atual.