865 resultados para Time and frequency autocorrelation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

There are no standardised serving/portion sizes defined for foods consumed in the European Union (EU). Typical serving sizes can deviate significantly from the 100 g/100 ml labelling specification required by the EU legislation. Where the nutritional value of a portion is specified, the portion size is determined by the manufacturers. Our objective was to investigate the potential for standardising portion sizes for specific foods, thereby ensuring complementarity across countries. We compared portion size for 156 food items measured using a food frequency questionnaire across the seven countries participating in the Food4me study. The probability of consuming a food and the frequency of consumption differed across countries for 93% and 58% of the foods, respectively. However, the individual country mean portion size differed from the average across countries in only 16% of comparisons. Thus, although dietary choices vary markedly across countries, there is much less variation in portion sizes. Our results highlight the potential for standardisation of portion sizes on nutrition labels in the EU

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Statement of the problem: The performance of self-etch systems on enamel is controversial and seems to be dependent on the application technique and the enamel preparation. Purpose of the Study: To examine the effects of conditioning time and enamel surface preparation on bond strength and etching pattern of adhesive systems to enamel. Materials and Methods: Ninety-six teeth were divided into 16 conditions (N = 6) in function of enamel preparation and conditioning time for bond strength test. The adhesive systems OptiBond FL (Kerr, Orange, CA, USA), OptiBond SOLO Plus (Kerr), Clearfil SE Bond (Kuraray, Osaka, Japan), and Adper Prompt L-Pop (3M ESPE, St. Paul, MN, USA) were applied on unground or ground enamel following the manufacturers` directions or doubling the conditioning time. Cylinders of Filtek Flow (0.5-mm height) were applied to each bonded enamel surface using a Tygon tube (0.7 mm in diameter; Saint-Gobain Corp., Aurora, OH, USA). After storage (24 h/37 degrees C), the specimens were subjected to shear force (0.5 mm/min). The data were treated by a three-way analysis of variance and Tukey`s test (alpha = 0.05). The failure modes of the debonded interfaces and the etching pattern of adhesives were observed using scanning electron microscopy. Results: Only the main factor ""adhesive"" was statistically significant (p < 0.001). The lowest bond strength value was observed for OptiBond FL. The most defined etching pattern was observed for 35% phosphoric acid and for Adper Prompt L-Pop. Mixed failures were observed for all adhesives, but OptiBond FL showed cohesive failures in resin predominantly. Conclusions: The increase in the conditioning time as well as the enamel pretreatment did not provide an increase in the resin-enamel bond strength values for the studied adhesives. CLINICAL SIGNIFICANCE The surface enamel preparation and the conditioning time do not affect the performance of self-etch systems to enamel. (J Esthet Restor Dent 20:322-336, 2008)

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Several works in the shopping-time and in the human-capital literature, due to the nonconcavity of the underlying Hamiltonian, use Örst-order conditions in dynamic optimization to characterize necessity, but not su¢ ciency, in intertemporal problems. In this work I choose one paper in each one of these two areas and show that optimality can be characterized by means of a simple aplication of Arrowís (1968) su¢ ciency theorem.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A computer-based sliding mode control (SMC) is analysed. The control law is accomplished using a computer and A/D and D/A converters. Two SMC designs are presented. The first one is a continuous-time conventional SMC design, with a variable structure law, which does not take into consideration the sampling period. The second one is a discrete-time SMC design, with a smooth sliding law, which does not have a structure variable and takes into consideration the sampling period. Both techniques are applied to control an inverted pendulum system. The performance of both the continuous-time and discrete-time controllers are compared. Simulations and experimental results are shown and the effectiveness of the proposed techniques is analysed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the setting time and the thermal expansion coefficient of 2 endodontic cements, MTA-Angelus and a novel cement called CER. The setting time was determined in accordance to ANSI/ADA specifications no. 57. Three samples of 10 mm diameter and 2 mm thickness were prepared for each cement. The thermal expansion measurements were performed by strain gauge technique. Four samples of each cement were prepared using silicone rings of 5 mm diameter and 2 mm thickness. The data were analyzed statistically using the Student t test. The setting time obtained for the MTA-Angelus and CER cements was 15 (SD 1) min and 7 (SD 1) min, respectively. The linear coefficient of thermal expansion was 8.86 (SD 0.28) mu strain/degrees C for MTA-Angelus and 11.76 (SD 1.20) mu strain/degrees C for CER. The statistical analysis showed significant difference (P < .05) in the setting time and linear coefficient of thermal expansion between the 2 cements. The CER cement has a coefficient of expansion similar to dentin, which could contribute to a decrease of microleakage degree.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: We investigated the effects of length of exposure to tobacco smoke on the cardiac remodeling process induced by exposure to cigarette smoke in rats.Material/Methods: Rats were separated into 4 groups: nonsmoking (NS) 2 (n=25; control animals not exposed to tobacco smoke for 2 months), smoking (S)2 (n=22; rats exposed to smoke from 40 cigarettes/d for 2 months), NS6 (n=18; control animals not exposed to tobacco smoke for 6 months), and S6 (n=25; rats exposed to smoke from 40 cigarettes/d for 6 months). All animals underwent echocardiographic, isolated heart, and morphometric studies. Data were analyzed with a 2-way analysis of variance.Results: No interaction among the variables was found; this suggests that length of exposure to tobacco smoke did not influence the effects of exposure to smoke. Values for left ventricular diastolic diameter/body weight and left atrium/body weight were higher (p=0.023 and p=0.001, respectively) in smoking (S2 and S6) than in nonsmoking animals (NS2 and NS6). Left ventricular mass index was higher (p=0.048) in smoking than in nonsmoking animals. In the isovolumetrically beating ventricle, peak systolic pressure was higher (p=0.034) in smoking than in nonsmoking animals. Significantly higher values were found for left ventricular weight (p=0.017) and right ventricular weight (p=0.001) adjusted for body weight in smoking as opposed to nonsmoking animals. Systolic pressure was higher (p=0.001) in smoking (128 +/- 14 mm Hg) than in nonsmoking animals (112 +/- 11 mm Hg).Conclusions: Length of exposure to cigarette smoke did not influence cardiac remodeling caused by exposure to sm oke in rats.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim. The purpose of this study was to provide normal values for maximum phonation time (MPT) and the s/z ratio by examining 1660 children aged 4-12 years and without vocal signs or symptoms.Methods. The technique was based on the sustained emission of the /a/ vowel and fricatives /s/ and /z/.Results. The average of the MPT in children of the different age groups was as follows: 6.09 seconds for the age group 4-6 years (males, 5.97; female, 6.21 seconds), 7.94 seconds for the age group 7-9 years (males, 8.07; females, 7.79 seconds), and 8.98 for the age group 10-12 years (males, 9.05; females, 8.92 seconds). The overall average for males was 7.78 and females 7.64 seconds. The s/z ratio was near 1.0 in most children but above 1.2 in 133 children and below 0.8 in 133 children.Conclusion. These values of MPT and s/z ratio can be used as normative in further pediatric studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective. The aim of this study was to investigate the influence of shortening the etching time on the bond strength of a conventional and a self-etching primer adhesive system used in primary tooth dentin.Methods. Flat dentin surfaces were obtained from 24 primary molars, randomly assigned to 4 experimental groups. The adhesive systems Single Bond and Clearfil SE Bond were applied in two groups according to the manufacturers' recommendations. In the other two groups, the adhesives were applied after half-time of acid etching, 7 s for Single Bond and 10 s for Clearfil SE Primer. Resin crowns were built up and after 24 h storage in water at 37 &DEG; C, the teeth were sectioned to produce beams with cross-sectional area of approximately 0.49 mm(2). Specimens were tested in tension at 0.5 mm/min until failure. Fractured specimens were analyzed to determine the failure mode.Results. Tensile bond strengths for Single Bond in primary dentin were higher than for Clearfil SE Bond. Shortening of acid etching time improved bond strength only for Single Bond, while no statistically significant difference was observed for Clearfil SE Bond when both etching times were compared.Significance. No detrimental effect on bond strength was observed when the time of acid etching was shortened in 50%. Shortening the time for a procedure in a small child without compromising the quality of the work is a very important finding for the practicing pediatric dentist. © 2004 Elsevier Ltd. All rights reserved.