497 resultados para Tibial Dyschondroplasia
Resumo:
5 to 10% of all fractures present with a delayed union, whereas 1 to 5% progress to a nonunion, which can be defined as a fracture older than 6 months and lacks any potential to heal without any further intervention. Different fracture and patient related risk factors exist, and the management of a nonunion needs a thorough clinical, radiological and biological workup to classify them in one of the two main categories, the viable nonunions that need essentially more stability, usually by a more rigid fixation, and the non-viable nonunions that need essentially a biological stimulation by decortication and bone grafting. This treatment still remains the first choice with bony healing obtained in 85 to 95% of cases, but it also comes along with certain risks, and some valuable alternatives exist if chosen on the basis of rigid criteria.
Resumo:
Posterolateral corner (PLC) injuries of the knee are uncommon injury patterns that may result in significant degrees of functional disability. When surgery is necessary to address this injury a good knowledge of anatomy and a good surgical exposure is the mainstay. This report reviews the complex anatomy of the posterolateral corner (PLC) of knee and describes the osteotomy of Gerdy tubercle as a technical variant to approach this anatomical region. This surgical step allowing a good mobilisation of the multiple layers of ilio-tibial tract from distal to proximal makes an excellent exposure of the PLC structures with absence of morbidity.
Resumo:
Between 1985 and 1990 we treated 11 large segmental bone defects (average 6.7 cm) in ten patients with the Ilizarov technique. Open fractures, type III according to Gustilo, represented the largest group (8 of 11 cases). The average delay before the Ilizarov technique was initiated was 8.9 months. The external fixator was usually maintained for 1 year. Bone regeneration was obtained in every case. Consolidation was not fulfilled with this technique in three cases. The complications observed were one refracture, four leg-length discrepancies (average 1.5 cm), and five axial deformities exceeding 5 degrees. No pin-track infection was observed. In our limited series of four type IIIC open fractures treated by the Ilizarov technique, no patients required amputation. The Ilizarov technique is particularly useful in the treatment of large bone defects, without major complications, especially if there is an adequate initial debridement.
Resumo:
Rrésumé: La première description dans une publication médicale des douleurs neuropathiques remonte à 1872, le Dr S.W. Mitchell les résumant ainsi [...]" la causalgie est la plus terrible des tortures qu'une lésion nerveuse puisse entraîner "[...]. Par définition, la douleur neuropathique est une douleur chronique faisant suite à une lésion ou dysfonction du système nerveux. Malgré les progrès faits dans la compréhension de ce syndrome, le détail des mécanismes impliqués nous échappe encore et son traitement reste insuffisant car moins de 50% des patients sont soulagés par les thérapies actuelles. Différents modèles expérimentaux ont été élaborés chez l'animal de laboratoire, en particulier des modèles de lésion de nerfs périphériques chez le rat, permettant des investigations tant moléculaires que fonctionnelles des mécanismes impliqués dans le développement de ces douleurs. En revanche, peu de modèles existent chez la souris, alors que cet animal, grâce à la transgénèse, est très fréquemment utilisé pour l'approche fonctionnelle ciblée sur un gène. Dans l'étude présentée ici, nous avons évalué chez la souris C57BL/6 l'adaptation d'un modèle neuropathique, proposé une nouvelle modalité de mesure de la sensibilité douloureuse adaptée à la souris et défini une méthode d'analyse performante des résultats. Ce modèle, dit de lésion avec épargne nerveuse (spared Werve injury, SNI), consiste en la lésion de deux des trois branches du nerf sciatique, soit les nerfs peronier commun et tibial. La troisième branche, le nerf sural est laissé intact et c'est dans le territoire cutané de ce dernier que la sensibilité douloureuse à des stimulations mécaniques est enregistrée. Des filaments calibrés de force croissante sont appliqués sur la surface de la patte impliquée et la fréquence relative de retrait de la patte a été modélisée mathématiquement et analysée par un modèle statistique intégrant tous les paramètres de l'expérience (mixed-effects model). Des variantes chirurgicales lésant séquentiellement les trois branches du nerf sciatique ainsi que la réponse en fonction du sexe de l'animal ont également été évaluées. La lésion SNI entraîne une hypersensibilité mécanique marquée comparativement aux souris avec chirurgie contrôle; cet effet est constant entre les animaux et persiste durant les quatre semaines de l'étude. De subtiles différences entre les variables, y compris une divergence de sensibilité mécanique entre les sexes, ont été démontrées. La nécessité de léser le nerf tibial pour le développement des symptômes a également été documentée par notre méthode d'évaluation et d'analyse. En conclusion, nous avons validé le modèle SNI chez la souris par l'apparition d'un symptôme reproductible et apparenté à l'allodynie mécanique décrite par les patients souffrant de douleurs neuropathiques. Nous avons développé des méthodes d'enregistrement et d'analyse de la sensibilité douloureuse sensibles qui permettent la mise en évidence de facteurs intrinsèques et extrinsèques de variation de la réponse. Le modèle SNI utilisé chez des souris génétiquement modifiées, de par sa précision et reproductibilité, pourra permettre la discrimination de facteurs génétiques et épigénétiques contribuant au développement et à la persistance de douleurs neuropathiques.
Resumo:
L'alineació rotacional a l'astroplàstia total de genoll es refereix a la posició dels implants en el pla axial. Un mínim desplaçament afectarà la distribució de la càrrega y variarà l'estabilitat, l'alineació i la cinemàtica de l'articulació. Tot i que hi ha un consens pel que fa als efectes adversos d'una alineació rotacional incorrecta, encara no està clar quines són les referències anatòmiques que cal utilitzar. Les mesures de l'alineació rotacional requereixen un estudi d'alta qualitat. La TC és la modalitat d'imatge d'elecció per a l'estudi postoperatori de l'artroplàstia total de genoll. L'objectiu d'aquest treball es avaluar la capacitat diagnòstica de la TC per a l'estudi de l'alineació rotacional postoperatòria en l'artroplàstia total de genoll i presentar les variacions en el protocol de TC que minimitzen l'artefacte metàl•lic. Aquest estudi avalua la reproductibilitat de l'angle condili posterior, format per l'eix epicondili quirúrgic i la línia bicondilia posterior, mesurant la correlació entre dos observadors. El coeficient de correlació de Pearson mostra una forta correlació positiva (R=0.84) entre els dos observadors. La mitja d'error de les mesures adquirides és de -0.14º amb una desviació estàndar de 2.06º (-0.14 ± 2.06), per la qual cosa la modificació dels paràmetres tècnics de la TC per a la minimització dels artefactes metàl•lics és eficaç per l'avaluació rotacional. No obstant, l'alta magnitud de l'error indica que el radiòleg ha de ser prudent en el diagnòstic de mínimes variacions angulars que impliquin canvis en l'actitud mèdica i terapèutica.
Resumo:
Introduction The flexible derotator is one of the therapeutic resources used to combat primary and secondary abnormalities in walking cerebral palsy children. It was developed to reduce abnormal femoral and tibial torsions and lessen the latter's negative functional impact. Objective To determine the effect of wearing a flexible derotator on anatomic and functional parameters in walking cerebral palsy children. Methods We performed a retrospective study of walking cerebral palsy children by gathering data on bone-related parameters (femoral and tibial torsion) and functional parameters (distance and speed gait, and the energy expenditure index (EEI)). Fifteen walking cerebral palsy children were treated with the flexible derotator for one year and 15 untreated walking cerebral palsy children were included as controls. The two groups were compared in terms of the various parameters' change over time between the initial examination (the last examination prior to the start of the study or prior to use of the flexible derotator) and the final examination (after one year of follow-up). Results Right femoral anteversion and right and left external tibial torsion improved. There was a significant increase in distance and speed gait and a decrease in the EEI in walking cerebral palsy children. Conclusion Our retrospective study revealed a significant improvement in functional parameters in children with cerebral palsy, as a result of wearing the flexible derotator for at least 6 hours a day for a year. Bone parameters only improved slightly. Use of the flexible derotator could improve these children's quality of life.
Resumo:
BACKGROUND: The AO comprehensive pediatric longbone fracture classification system describes the localization and morphology of fractures, and considers severity in 3 categories: (1) simple, (2) wedge, and (3) complex. We evaluated the reliability and accuracy of surgeons in using this rating system. MATERIAL AND METHODS: In a first validation phase, 5 experienced pediatric (orthopedic) surgeons reviewed radiographs of 267 prospectively collected pediatric fractures (agreement study A). In a second study (B), 70 surgeons of various levels of experience in 15 clinics classified 275 fractures via internet. Simple fractures comprised about 90%, 99% and 100% of diaphyseal (D), metaphyseal (M), and epiphyseal (E) fractures, respectively. RESULTS: Kappa coefficients for severity coding in D fractures were 0.82 and 0.51 in studies A and B, respectively. The median accuracy of surgeons in classifying simple fractures was above 97% in both studies but was lower, 85% (46-100), for wedge or complex D fractures. INTERPRETATION: While reliability and accuracy estimates were satisfactory as a whole, the ratings of some individual surgeons were inadequate. Our findings suggest that the classification of fracture severity in children should be done in only two categories that distinguish between simple and wedge/complex fractures.
Resumo:
Total ankle replacement remains a less satisfactory solution compared to other joint replacements. The goal of this study was to develop and validate a finite element model of total ankle replacement, for future testing of hypotheses related to clinical issues. To validate the finite element model, an experimental setup was specifically developed and applied on 8 cadaveric tibias. A non-cemented press fit tibial component of a mobile bearing prosthesis was inserted into the tibias. Two extreme anterior and posterior positions of the mobile bearing insert were considered, as well as a centered one. An axial force of 2kN was applied for each insert position. Strains were measured on the bone surface using digital image correlation. Tibias were CT scanned before implantation, after implantation, and after mechanical tests and removal of the prosthesis. The finite element model replicated the experimental setup. The first CT was used to build the geometry and evaluate the mechanical properties of the tibias. The second CT was used to set the implant position. The third CT was used to assess the bone-implant interface conditions. The coefficient of determination (R-squared) between the measured and predicted strains was 0.91. Predicted bone strains were maximal around the implant keel, especially at the anterior and posterior ends. The finite element model presented here is validated for future tests using more physiological loading conditions.
Resumo:
INTRODUCTION: We tested the hypothesis that twitch potentiation would be greater following conventional (CONV) neuromuscular electrical stimulation (50-µs pulse width and 25-Hz frequency) compared with wide-pulse high-frequency (WPHF) neuromuscular electrical stimulation (1-ms, 100-Hz) and voluntary (VOL) contractions, because of specificities in motor unit recruitment (random in CONV vs. random and orderly in WPHF vs. orderly in VOL). METHODS: A single twitch was evoked by means of tibial nerve stimulation before and 2 s after CONV, WPHF, and VOL conditioning contractions of the plantar flexors (intensity: 10% maximal voluntary contraction; duration: 10 s) in 13 young healthy subjects. RESULTS: Peak twitch increased (P<0.05) after CONV (+4.5±4.0%) and WPHF (+3.3±5.9%), with no difference between the 2 modalities, whereas no changes were observed after VOL (+0.8±2.6%). CONCLUSIONS: Our results demonstrate that presumed differences in motor unit recruitment between WPHF and CONV do not seem to influence twitch potentiation results.
Resumo:
OBJECTIVE: Assess the degree of satisfaction in a series of patients between 50 and 60 years of age who underwent surgery in our unicompartmental prosthesis unit (UPU) for monocompartmental gonarthrosis. Likewise, the definition based on current literature is assessed, as well as our experience in the indications, inconveniences and results of the internal knee unicompartmental arthroplasty discussed with supra-tuberosity tibial osteotomy, which was the common surgical option in these cases.MATERIAL AND METHOD: This study included 19 patients between 50 and 60 years of age (average age 56.7 years) (Interval of 51-60 years) intervened between 7/2007 and 11/2011 by the same surgeon (GDFB). Functional assessment used the Oxford Knee Score (OKS) questionnaire. A bibliographic search was performed in the MEDLINE, COCHRANE and EMBASE databases from 1988 to 2012. RESULTS: With an average follow-up of 29.4 months, 16 of 19 patients stated that they were satisfied with the results obtained and would repeat the intervention. One patient sufered a prosthetic infection and was reviewed for total knee replacement with good results. CONCLUSIONS: the medial, unicompartmental arthroplasty of the knee is a valid surgical option and reproducible in the medium term treatment of monocompartmental gonarthrosis in patients between 50 and 60 years of age.
Resumo:
We carried out a descriptive, retrospective study with a sample side of 121 patients with Legión® prosthesis replacement in our Vírgen del Rocío hospital area, in the city of Seville, from May of 2008 until March of 2011. This study included epidemiological data as well as technical information about the process performed, including post-operative pain, mobility and functional results using a functional assessment scale and series of radiological studies. Average follow-up was 19 months, with a mean age of 71 years and 87% women. We obtained an average of 20.41º for articular balance obtained, correction of prior deformities by restoring the tibia-femoral axis to the anatomic e balance articular angle; we resolved bone loss prior to replacement and carried out an adequate balance of the inter-lineal joint. 66% of the patients continued with no post-operative pain, with the other 33% reporting slight to moderate pain. With regards to pain at the point of the stem, we have found no significant relationship with the incidence angle of the stem on the cortical or with the type of cement. We observed a 74% rate of intervention without complications, with complications being rupture of the patellar tendon in one patient, one case of peri-prosthesis fracture, two iatrogenic avulsion fractures of the anterior tibial tuberosity and seven infections (4 were diagnosed previously).
Resumo:
Introduction: Posttraumatic painful osteoarthritis of the ankle joint after fracture-dislocation often has to be treated with arthrodesis. In the presence of major soft tissue lesions and important bone loss the technique to achieve arthrodesis has to be well chosen in order to prevent hardware failure, infection of bulky implants or non-union. Methods: We present the case of a 53 year-old biker suffering of a fracture-dislocation of the ankle associated with a mayor degloving injury of the heel. After initial immobilization of the lesion by external fixation in Spain the patient was transferred to our hospital for further treatment. The degloving injury of the heel with MRSA infection was initially treated by repeated débridement, changing of the configuration of the Ex Fix and antibiotic therapy with favourable outcome. Because of the bony lesions reconstruction of the ankle-joint was juged not to be an option and arthrodesis was planned. Due to bad soft-tissue situation standard open fixtion with plate and/or screws was not wanted but an option for intramedullary nailing was taken. However the use of a standard retrograde arthrodesis nail comes with two problems: 1) Risk of infection of the heel-part of the calaneus/nail in an unstable soft tissue situation with protruding nail. And 2) talo-calcaneal arthrodesis of an initially healthy subtalar joint. Given the situation of an unstable plantar/heel flap it was decided to perform anklearthrodesis by means of an anterograde nail with static fixation in the talus and in the proximal tibia. Results:This operation was performed with minimal opening at the ankle-site in order to remove the remaining cartilage and improve direct bone to bone contact. Arthrodesis was achieved by means of an anterograde T2 Stryker tibial nail.One year after the anterograde nailing the patient walks without pain for up to 4 hours with a heel of good quality and arthrodesis is achieved. Conclusion: Tibiotalar arthrodesis in the presence of mayor soft tissue lesions and bone loss can be successfully achieved with antegrade nailing.
Resumo:
Total knee replacement (TKR) is an operation that has radically improved the quality of life of millions of people during the last decades. However, some technical details, concerning the surgical procedure, are still a matter of a strong debate. In this review of the literature, we have included the best evidence available of the last decade, related to TKR surgery like the use of tourniquet during operation, patellar resufacing, all-polyethilene tibial component, cemented or cementless fixation, mobile bearings, or posterior-stabilized versus cruciate-retaining prosthesis.
Resumo:
Integration without cytotoxic effects and long-term expression of a transgene constitutes a major challenge in gene therapy and biotechnology applications. In this context, transposons represent an attractive system for gene transfer because of their ability to promote efficient integration of a transgene in a variety of cell lines. However, the transgene integration can lead to insertional mutagenesis and/or unstable transgene expression by epigenetic modifications. These unwanted events may be limited by the use of chromatin control elements called MARs (matrix attachment regions). Indeed, the insertion of these DNA elements next to the transgene usually results in higher and more stable expression by maintaining transgene chromatin in an active configuration and preventing gene silencing. In this study, we tested if the inclusion of the MAR 1-68 in the piggyBac transposon system may lead to efficient and safer transgene integration and ensure reliable stable and long-term expression of a transgene. The MAR-containing transposon construct was tested in CHO cells, for biotechnology applications, and in mesoangioblast cells that can differentiate into muscle cells and are important candidates for potential stem cell therapies of myopathies. We showed that the addition of the MAR 1 -68 in the piggyBac transposon did not interfere with transposition, thereby maintaining high frequency of transgene integrations in these cells. Moreover, the MAR allowed higher transgene expression from fewer transposon integration events. We also found that enriched transgene-expressing cell populations could be obtained without the need of selection pressure. Since antibiotic-enforced selection protocols often result in a higher integrated copy number and mosaic expression patterns, this strategy could benefit many applications in which a low copy number of integrated transgenes and antibiotic-free conditions are desired. In addition, the intramuscular transplantation of mouse tibialis anterior muscles with mesoangioblasts containing the transposon led to widespread and sustained myofiber transgene expression after differentiation of these cells in vivo. These findings indicated that piggyBac vectors may provide a viable approach to achieve stable gene transfer in the context of Duchenne muscular dystrophy therapy. - L'intégration sans effets cytotoxiques et l'expression à long terme d'un transgène constituent un défi majeur en thérapie génique et en biotechnologie. Dans ce contexte, les transposons représentent un système attrayant pour le transfert de gènes en raison de leur capacité à promouvoir l'intégration efficace d'un transgène dans une variété de lignées cellulaires. Toutefois, l'intégration d'un transgène peut conduire à une mutagénèse insertionnelle et/ou à une expression instable due au silençage du transgène suite à des modifications épigénétiques. Ces événements indésirables de silençage génique peuvent être diminués par l'utilisation d'éléments de contrôle de la chromatine appelés MAR (matrix attachment region). En effet, l'insertion de ces éléments d'ADN à proximité du transgène se traduit généralement par une expression plus élevée et plus stable de celui-ci, en permettant le maintien d'une chromatine dans une configuration active autour du transgène et en empêchant l'inactivation du gène. Dans cette étude, nous avons testé si l'inclusion du MAR 1-68 dans le système transposon piggyBac peut améliorer l'efficacité d'intégration de façon sécuritaire et l'expression à long terme d'un transgène. Le transposon contenant l'élément MAR a été testé dans les cellules CHO, couramment utilisées en biotechnologie, et dans des cellules progénitrices appelées mésoangioblastes, qui peuvent se différencier en cellules musculaires, et qui constituent ainsi des candidats prometteurs pour la thérapie à partir de cellules souches de patients souffrant de myopathie. Nous avons montré que l'addition du MAR 1-68 dans le transposon piggyBac n'interfère pas avec la transposition et permet de maintenir une fréquence élevée d'intégration du transgène dans ces deux types cellulaires. De plus, il semble que cette association mène à une meilleure expression du transgène à partir de peu d'événements d'intégration du transposon. En outre, ces populations enrichies en cellules exprimant de façon stable le transgène ont pu être obtenues sans avoir recours à une pression de sélection. Etant donné que les protocoles de sélection basée sur l'utilisation d'antibiotiques conduisent souvent à un nombre plus élevé de copies intégrées et à la variégation de l'expression du transgène et qu'ils impliquent une longue culture in vitro, cette stratégie pourrait profiter à des applications pour lesquelles on souhaite un faible nombre de copies intégrées et/ou l'utilisation d'antibiotiques n'est pas souhaitable. De plus, la transplantation intramusculaire de mésoangioblastes contenant le transposon dans le muscle tibial antérieur de souris a conduit, après la différentiation de ces cellules in vivo, à une expression constante et étendue du transgène dans les myofibres. Ces résultats indiquent que les vecteurs piggyBac pourraient fournir une approche viable pour assurer un transfert de gènes stables dans le contexte d'un traitement de la dystrophic musculaire de Duchenne.
Resumo:
Ideally, reconstruction of lower extremity soft tissue defects includes not only an esthetically pleasing 3-dimensional shape and solid anchoring to the underlying structures to resist shear forces, but should also address the restoration of sensation. Therefore, we present a prospective study on defect reconstruction of the lower leg and ankle to evaluate the role of sensate free fasciocutaneous lateral arm flap and the impact of sensory nerve reconstruction. Thirty patients were allocated randomly to the study group (n = 15) that obtained end-to-side sensate coaptation using the lower lateral cutaneous brachial nerve to the tibial nerve using the epineural window technique, or to the control group reconstructed without nerve coaptation. At 1-year follow-up the patients were evaluated for pain sensation, thermal sensibility, static and moving 2-point discrimination, and Semmes-Weinstein monofilament tests. Data from both groups were compared and statistically analyzed with the Mann-Whitney U test and the Fisher exact test. Flaps of the study group reached a static and moving 2-point discrimination and Semmes-Weinstein monofilament tests nearly equal to the contralateral leg area and significantly better than flaps of the control group. Donor damage morbidity of the tibial nerve did not occur. To our point of view resensation should be carried out by end-to-side neurorrhaphy to the tibial nerve because of the superior restoration of sensibility.