959 resultados para Tensão de aderência
Resumo:
This paper presents a technique to add flexibility in the control of power electronic converters. The power converter can function as an active power filter, as a local power source interface or perform both functions i. e. mitigate current disturbances and inject power into the grid simultaneously, configuring it as a multifunctional device. The main goal is to extract the full capability of the grid connected power electronic converter to achieve maximum benefits. To achieve this goal, the orthogonal current decomposition of the Conservative Power Theory is used. Each orthogonal current component is weighted by means of different compensation factors (k_i), which are set instantaneously and independently, in any percentage by means of the load performance factors (λ_i), providing an online flexibility in relation to compensation objectives. Finally, to validate the effectiveness and performance the proposed approach, simulations and experimental results are presented.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Engenharia Elétrica - FEB
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Letras - IBILCE
Resumo:
The public consultation n° 018/2014, for review the Module 8 of Procedures of Electricity Distribution (PRODIST), conducted by National Agency of Electric Energy (ANEEL), aims to improve the regulation of power quality, considering the phenomena harmonic distortion, voltage unbalance, voltage fluctuation and short term voltage variation. These regulatory changes impact in the way of analysis and treatment, of power quality disruption, by the electricity distribution. The developed work makes a study about the applications of these new regulatory requests and hopes to contribute with a better understanding. Through power quality measurements, in distribution substations, with different load profiles (industrial, urban and rural), was obtained a real view of the system, under the aspect of power quality, to evaluate the regulation adherence to the current version and proposed. In this case study, although being in accordance with the current methodology, happened a transgression of propose. With a comparative analysis, was possible to identify some phenomena that were more flexible in the proposed revision and others with more severe monitoring
Resumo:
This work talks about the importance of the steel adhesion to concrete, reinforced concrete structures, their testing and forms of measurement used and how the results are used in the structural design, which uses as a reference the NBR 6118 and NBR 7480. It also deals with the importance of a reliable assessment, discussing failures that the test used, NBR 7477, features in specific circumstances, as discussed under the EC-094. It also presents an initial proposal for simplified pullout test, which aims to analyze the grip on steel bars with diameter less than 10 mm, which results when used standardized testing by ABNT NBT 7477, has shown excessive variability, the main criticism of the trial today used without distinction to be established thick or thin bars. The proposal also presented methodology is in the consolidation phase, given the time and the volume of necessary tests. For this reason it is not possible to make a comparison between the values obtained and the results of the test used on the basis of the standard in force, this can only be done once the front with a continuation of this work
Resumo:
In this paper, we will present an overview of the smart grid defining the three main systems that compose it: smart infrastructure system, smart management system and smart protection system. We will conceptualize a functionality of smart management system, the conservative voltage reduction, citing its benefits and its history of application. And, finally, we'll cover a test in which we reduce the nominal voltages on incandescent bulbs, CFL and LED, in the context of residential lighting, and on LED and HPS, in the context of public lighting. The test aims to check whether the voltage reduction adversely affects sources of lighting by measuring the temperature manually with a thermal imaging camera FLIR and illuminance with a LUX meter. The set of power factor, total harmonic distortion, and input power values will be collected automatically through the power quality Analyzer Fluke 345 with a probe Fluke Hall Effect Current. For residential lighting, it was found that both CFL and LED had good performance with the smallest variations in illuminance. Between both, the LED source had the lowest harmonics and the lowest power consumption, on the other hand incandescent bulbs had a bad performance as expected. Public light sources also had a good performance and obtained power factors within the standards, as opposed to the CFL and LED residential sources. The data collected clearly shows the feasibility for nominal voltage reductions. Even with small reductions, there are possibilities of savings which can be passed on to the utilities and consumers
Resumo:
The public consultation n° 018/2014, for review the Module 8 of Procedures of Electricity Distribution (PRODIST), conducted by National Agency of Electric Energy (ANEEL), aims to improve the regulation of power quality, considering the phenomena harmonic distortion, voltage unbalance, voltage fluctuation and short term voltage variation. These regulatory changes impact in the way of analysis and treatment, of power quality disruption, by the electricity distribution. The developed work makes a study about the applications of these new regulatory requests and hopes to contribute with a better understanding. Through power quality measurements, in distribution substations, with different load profiles (industrial, urban and rural), was obtained a real view of the system, under the aspect of power quality, to evaluate the regulation adherence to the current version and proposed. In this case study, although being in accordance with the current methodology, happened a transgression of propose. With a comparative analysis, was possible to identify some phenomena that were more flexible in the proposed revision and others with more severe monitoring
Resumo:
This work talks about the importance of the steel adhesion to concrete, reinforced concrete structures, their testing and forms of measurement used and how the results are used in the structural design, which uses as a reference the NBR 6118 and NBR 7480. It also deals with the importance of a reliable assessment, discussing failures that the test used, NBR 7477, features in specific circumstances, as discussed under the EC-094. It also presents an initial proposal for simplified pullout test, which aims to analyze the grip on steel bars with diameter less than 10 mm, which results when used standardized testing by ABNT NBT 7477, has shown excessive variability, the main criticism of the trial today used without distinction to be established thick or thin bars. The proposal also presented methodology is in the consolidation phase, given the time and the volume of necessary tests. For this reason it is not possible to make a comparison between the values obtained and the results of the test used on the basis of the standard in force, this can only be done once the front with a continuation of this work
Resumo:
In this paper, we will present an overview of the smart grid defining the three main systems that compose it: smart infrastructure system, smart management system and smart protection system. We will conceptualize a functionality of smart management system, the conservative voltage reduction, citing its benefits and its history of application. And, finally, we'll cover a test in which we reduce the nominal voltages on incandescent bulbs, CFL and LED, in the context of residential lighting, and on LED and HPS, in the context of public lighting. The test aims to check whether the voltage reduction adversely affects sources of lighting by measuring the temperature manually with a thermal imaging camera FLIR and illuminance with a LUX meter. The set of power factor, total harmonic distortion, and input power values will be collected automatically through the power quality Analyzer Fluke 345 with a probe Fluke Hall Effect Current. For residential lighting, it was found that both CFL and LED had good performance with the smallest variations in illuminance. Between both, the LED source had the lowest harmonics and the lowest power consumption, on the other hand incandescent bulbs had a bad performance as expected. Public light sources also had a good performance and obtained power factors within the standards, as opposed to the CFL and LED residential sources. The data collected clearly shows the feasibility for nominal voltage reductions. Even with small reductions, there are possibilities of savings which can be passed on to the utilities and consumers
Resumo:
O objetivo deste estudo foi verificar como as organizações brasileiras de grande porte tratam investimentos de longo prazo. O constructo teórico levou em conta tanto a literatura de estratégia quanto a de finanças, a partir das quais foram propostas hipóteses envolvendo a utilização de métodos e mecanismos para avaliação de investimentos. Por meio de um questionário eletrônico, desenvolveu-se um levantamento junto a 82 empresas, e, com o emprego da técnica de modelagem de equações estruturais, constatou-se aderência parcial ao modelo teórico. Dentre os achados, verificou-se que os mecanismos de análise de investimentos estão associados positivamente à preocupação com a análise do risco percebido. Em adição, constatou-se que projetos aprovados no planejamento estratégico apresentam acompanhamento relativamente mais estruturado e que a maior necessidade de definição de financiamento e custo de oportunidade está associada positivamente à inclusão do projeto no planejamento estratégico.
Resumo:
El trabajo pretende indagar en los diversos sentidos que adquiere un espacio público de la Ciudad de Buenos aires ubicado en el barrio de Mataderos, el Parque Alberdi. A partir del análisis de su construcción, su equipamiento y las intervenciones posteriores que se le realizaron, se pretende dar cuenta de los usos que el parque como institución propuso inicialmente y propone en la actualidad. A su vez, se busca rastrear las opiniones y recuerdos de los usuarios del parque. Un tercer eje a tomar, son los usos efectivos del parque, los tránsitos y prácticas que se realizan cotidianamente. A partir de estos tres ejes, se busca reconstruir los diversos sentidos que emergen en torno a este espacio público, y qué vínculos existen entre estos sentidos (identificación, solapamiento, oposición, filtraciones, resignificaciones, etc.). De este modo, este trabajo busca dialogar (a partir de una mirada territorializada) con la compleja categoría de espacio público, y las expectativas políticas y filosóficas que esta carga