930 resultados para Stone walls
Resumo:
The seismic behaviour of anchored sheet pile walls is a complex soil-structure interaction problem. Damaged sheet pile walls are very expensive to repair and their seismic behaviour needs to be investigated in order to understand their possible mechanisms of failure. The research described in this paper involves both centrifuge testing and Finite Element (FE) analyses aimed at investigating the seismic behaviour of an anchored sheet pile wall in dry sand. The model wall is tied to the backfill with two tie rods connected to an anchor beam. The accelerations of the sheet pile wall, the anchor beam and the soil around the wall were measured using miniature piezoelectric accelerometers. The displacement at the tip of the wall was also measured. Stain gauges at five different locations on the wall were used to measure the bending moments induced in the the wall. The anchor forces in the tie rods were also measured using load cells. The results from the centrifuge tests were compared with 2-D, plane strain FE analyses conducted using DIANA-SWANDYNE II and the observed seismic behaviour was explained in the light of these findings. © 2011 Taylor & Francis.
Resumo:
A series of dynamic centrifuge tests on reduced scale models of flexible retaining structures were conducted on the Turner beam centrifuge at the Schofield Centre of the University of Cambridge. The paper illustrates the main results of the experimental work in terms of observed amplifications of ground motion and mobilised shear stiffness and damping ratio for all tests. The experimental results for one test on a pair of cantilevered walls in dense sand are also presented in terms of measured bending moments and horizontal displacements of the walls during (maximum values) and at the end of (residual values) each seismic event. Finally, the experimental data are discussed in the light of the results obtained from dynamic numerical analyses of the behaviour of cantilevered walls under real seismic actions. © 2010 Taylor & Francis Group, London.
Resumo:
Stone masonry spires are vulnerable to seismic loading. Computational methods are often used to predict the dynamic linear elastic response of masonry towers and spires, but this approach is only applicable until the first masonry joint begins to open, limiting the ability to predict collapse. In this paper, analytical modeling is used to investigate the uplift, rocking and collapse of stone spires. General equations for static equilibrium of the spire under lateral acceleration are first presented, and provide a reasonable lower bound for predicting collapse. The dynamic response is then considered through elastic modal analysis and rigid body rocking. Together, these methods are used to provide uplift curves and single impulse overturning collapse curves for a complete range of possible spire geometries. Results are used to evaluate the historic collapse of two specific stone spires. © 2012 Elsevier Ltd.
Resumo:
Analytical methods provide a global context from which to understand the dynamics of stone spires, but computational and experimental methods are useful to predict more specific behavior of multiple block structures. In this paper, the spire of St. Mary Magdalene church in Waltham-on-the-Wolds, UK, which was damaged in the 2008 Lincolnshire Earthquake, is used as a case study. Both a physical model and a discrete element computational model of the spire were created and used to investigate collapse under constant horizontal acceleration, impulse base motion, and earthquake ground motion. Results indicate that the global behavior compares well with analytical modeling, but local block displacements evident in DEM and experimental results also reduce the stability of the structure. In this context, the observed damage to St. Mary Magdalene church is evaluated and discussed. © 2012 Elsevier Ltd.
Resumo:
This paper describes an experimental investigation of the behaviour of embedded retaining walls under seismic actions. Nine centrifuge tests were carried out on reduced-scale models of pairs of retaining walls in dry sand, either cantilevered or with one level of props near the top. The experimental data indicate that, for maximum accelerations that are smaller than the critical limit equilibrium value, the retaining walls experience significant permanent displacements under increasing structural loads, whereas for larger accelerations the walls rotate under constant internal forces. The critical acceleration at which the walls start to rotate increases with increasing maximum acceleration. No significant displacements are measured if the current earthquake is less severe than earthquakes previously experienced by the wall. The increase of critical acceleration is explained in terms of redistribution of earth pressures and progressive mobilisation of the passive strength in front of the wall. The experimental data for cantilevered retaining walls indicate that the permanent displacements of the wall can be reasonably predicted adopting a Newmark-type calculation with a critical acceleration that is a fraction of the limit equilibrium value.
Resumo:
Many typical ground improvement techniques that are used for liquefaction remediation, such as in situ densification, are not appropriate for application under existing buildings and more novel techniques are required. This paper describes centrifuge tests investigating the performance of rigid containment walls as a liquefaction remediation method. A simple frame structure, founded on a deep layer of loose, liquefiable sand was tested under earthquake shaking. Centrifuge tests were then carried out with containment walls around the base of the structure, extending through the full depth of the liquefiable layer and also partial depth. It is found that rigid containment walls can be very effective in reducing structural settlements primarily by preventing lateral movement of the foundation sand but the impermeability of the walls may also be important. Improvements in structural settlement are observed even when the walls do not extend through the full depth of the liquefiable layer, if the depth of the walls is greater than the depth of the free field liquefaction. In addition, it is found that the accelerations of the structure are not increased, provided there is no rigid, structural connection between the structure and the containment walls. © 2012 World Scientific Publishing Company.
Resumo:
Ground improvement techniques can be adopted to prevent existing buildings built on liquefiable soils sustaining damage in future earthquakes. Impermeable geomembrane containment walls may be an economic and successful technique but their design and performance are currently not well defined or well understood for this application. This paper describes centrifuge testing carried out to investigate the performance of such containment walls as a liquefaction remediation method for a single degree of freedom frame structure. The results were compared with those from similar centrifuge testing carried out with the same structure founded on unimproved sand, to assess the effectiveness of the remediation method. It was found that the geomembrane containment walls tested were effective at reducing structural settlement and did not significantly increase the accelerations transmitted to the structure. Structural settlements were reduced primarily by mobilising hoop stress and preventing lateral soil movement. By preventing surface drainage, a decrease in the volume change of the foundation sand was also observed. In addition, the impermeability of the walls may be important as this prevented rapid migration of pore water fromthe free field to the foundation region.
Resumo:
Cement-bentonite (CB) cutoff walls have long been used to control ground water flow and contaminant migration at polluted sites. Hydraulic conductivity and unconfined compressive strength are two short-term properties often used by industry and owners in CB specification and are important parameters discussed in this paper. For polluted sites, long-term compatibility is also an important issue. These properties are coupled to a number of external factors including the mix design, construction sequence, presence/absence of contaminants at the site. Additional short-term properties for engineering assessment include the stressstrain characteristics in both drained and undrained shear in both with and without confinement as well as one-dimensional consolidation properties. Long term CB properties are affected by aging, reaction chemistry, drying, in situ stress state, and interaction with the polluted environment. © 2013 Taylor & Francis Group.
Resumo:
The discusser read with interest the paper by Diakoumi & Powrie (2013) proposing an interesting method for the analysis of propped flexible retaining walls based on the mobilisation of active and passive pressures on the wall due to movement of wall segments. An assumed deformation mechanism within the soil is used to estimate the strain associated with rotation of a particular wall segment. This mechanism is then superposed for each wall segment, the resulting earth pressures are calculated; the equality between the wall bending moments implied by equilibrium and those required to achieve the appropriate bending of the wall is used to calculate the rotation of each segment. Although the method of analysis provides insight into the conservatism of conventional design calculations for different wall flexibilities, there are two aspects of the paper which provoke further discussion.
Resumo:
The defect creation at low energy events was studied using density functional theory molecular dynamics simulations in silicon carbide nanotubes, and the displacement threshold energies determined exhibit a dependence on sizes, which decrease with decreasing diameter of the nanotubes. The Stone-Wales (SW) defect, which is a common defect configurations induced through irradiation in nanotubes, has also been investigated, and the formation energies of the SW defects increase with increasing diameter of the nanotubes. The mean threshold energies were found to be 23 and 18 eV for Si and C in armchair (5,5) nanotubes. (C) 2009 American Institute of Physics. [doi: 10.1063/1.3238307]
Resumo:
This review paper summarises briefly some important achievements of our recent research on the synthesis and novel applications of nanostructure ZnO such as honeycomb shaped 3-D (dimension) nano random-walls. A chemical reaction/vapour transportation deposition technique was employed to fabricate this structure on ZnO/SiO2/Si substrate without any catalyst and additive in a simple tube furnace to aim the low-cost and high qualified samples. Random laser action with strong coherent feedback at the wavelength between 375 nm and 395 nm has been firstly observed under 355 nm optical excitation with threshold pumping intensity of 0.38 MW/cm(2).
Resumo:
The hybrid between olive flounder Paralichthys olivaceus and stone flounder Kareius bicoloratus was produced by artificial insemination of olive flounder eggs with stone flounder sperm. Sinistral and dextral are two types of hybrid progeny after metamorphosis. Karyotypes of both hybrid flounders are the same as those of the two parental species. Of the 22 loci examined from 12 allozymes, 12 confirmed hybridization of the paternal and maternal loci in hybrids and no difference was found in allozyme patterns of sinistral and dextral hybrid fishes. RAPD patterns of these specimens were also studied with 38 primers selected from 104 tested. Among them, the PCR products of 30 primers showed hybridization of the paternal and maternal bands. Genetic variation between hybrids and their parental stocks was analyzed by RAPD using 10 of the above 38 primers. The average heterozygosity and genetic distance were calculated. The results suggested that the filial generation could inherit a little more genetic materials from paternal fish than that from maternal fish.