990 resultados para Stents and prostheses
Resumo:
OBJECTIVE To assess the 5-year survival of metal-ceramic and all-ceramic tooth-supported single crowns (SCs) and to describe the incidence of biological, technical and esthetic complications. METHODS Medline (PubMed), Embase, Cochrane Central Register of Controlled Trials (CENTRAL) searches (2006-2013) were performed for clinical studies focusing on tooth-supported fixed dental prostheses (FDPs) with a mean follow-up of at least 3 years. This was complimented by an additional hand search and the inclusion of 34 studies from a previous systematic review [1,2]. Survival and complication rates were analyzed using robust Poisson's regression models to obtain summary estimates of 5-year proportions. RESULTS Sixty-seven studies reporting on 4663 metal-ceramic and 9434 all-ceramic SCs fulfilled the inclusion criteria. Seventeen studies reported on metal-ceramic crowns, and 54 studies reported on all-ceramic crowns. Meta-analysis of the included studies indicated an estimated survival rate of metal-ceramic SCs of 94.7% (95% CI: 94.1-96.9%) after 5 years. This was similar to the estimated 5-year survival rate of leucit or lithium-disilicate reinforced glass ceramic SCs (96.6%; 95% CI: 94.9-96.7%), of glass infiltrated alumina SCs (94.6%; 95% CI: 92.7-96%) and densely sintered alumina and zirconia SCs (96%; 95% CI: 93.8-97.5%; 92.1%; 95% CI: 82.8-95.6%). In contrast, the 5-year survival rates of feldspathic/silica-based ceramic crowns were lower (p<0.001). When the outcomes in anterior and posterior regions were compared feldspathic/silica-based ceramic and zirconia crowns exhibited significantly lower survival rates in the posterior region (p<0.0001), the other crown types performed similarly. Densely sintered zirconia SCs were more frequently lost due to veneering ceramic fractures than metal-ceramic SCs (p<0.001), and had significantly more loss of retention (p<0.001). In total higher 5 year rates of framework fracture were reported for the all-ceramic SCs than for metal-ceramic SCs. CONCLUSIONS Survival rates of most types of all-ceramic SCs were similar to those reported for metal-ceramic SCs, both in anterior and posterior regions. Weaker feldspathic/silica-based ceramics should be limited to applications in the anterior region. Zirconia-based SCs should not be considered as primary option due to their high incidence of technical problems.
Resumo:
OBJECTIVE To assess the 5-year survival of metal-ceramic and all-ceramic tooth-supported fixed dental prostheses (FDPs) and to describe the incidence of biological, technical and esthetic complications. METHODS Medline (PubMed), Embase and Cochrane Central Register of Controlled Trials (CENTRAL) searches (2006-2013) were performed for clinical studies focusing on tooth-supported FDPs with a mean follow-up of at least 3 years. This was complemented by an additional hand search and the inclusion of 10 studies from a previous systematic review [1]. Survival and complication rates were analyzed using robust Poisson's regression models to obtain summary estimates of 5-year proportions. RESULTS Forty studies reporting on 1796 metal-ceramic and 1110 all-ceramic FDPs fulfilled the inclusion criteria. Meta-analysis of the included studies indicated an estimated 5-year survival rate of metal-ceramic FDPs of 94.4% (95% CI: 91.2-96.5%). The estimated survival rate of reinforced glass ceramic FDPs was 89.1% (95% CI: 80.4-94.0%), the survival rate of glass-infiltrated alumina FDPs was 86.2% (95% CI: 69.3-94.2%) and the survival rate of densely sintered zirconia FDPs was 90.4% (95% CI: 84.8-94.0%) in 5 years of function. Even though the survival rate of all-ceramic FDPs was lower than for metal-ceramic FDPs, the differences did not reach statistical significance except for the glass-infiltrated alumina FDPs (p=0.05). A significantly higher incidence of caries in abutment teeth was observed for densely sintered zirconia FDPs compared to metal-ceramic FDPs. Significantly more framework fractures were reported for reinforced glass ceramic FDPs (8.0%) and glass-infiltrated alumina FDPs (12.9%) compared to metal-ceramic FDPs (0.6%) and densely sintered zirconia FDPs (1.9%) in 5 years in function. However, the incidence of ceramic fractures and loss of retention was significantly (p=0.018 and 0.028 respectively) higher for densely sintered zirconia FDPs compared to all other types of FDPs. CONCLUSIONS Survival rates of all types of all-ceramic FDPs were lower than those reported for metal-ceramic FDPs. The incidence of framework fractures was significantly higher for reinforced glass ceramic FDPs and infiltrated glass ceramic FDPs, and the incidence for ceramic fractures and loss of retention was significantly higher for densely sintered zirconia FDPs compared to metal-ceramic FDPs.
Resumo:
BACKGROUND Although new-generation drug-eluting stents represent the standard of care among patients undergoing percutaneous coronary intervention, there remains debate about differences in efficacy and the risk of stent thrombosis between the Resolute zotarolimus-eluting stent (R-ZES) and the everolimus-eluting stent (EES). The aim of this study was to evaluate the safety and efficacy of the R-ZES compared with EES in patients undergoing percutaneous coronary intervention. METHODS AND RESULTS A systematic literature search of electronic resources was performed using specific search terms until September 2014. Random-effects meta-analysis was performed comparing clinical outcomes between patients treated with R-ZES and EES up to maximum available follow-up. The primary efficacy end point was target-vessel revascularization. The primary safety end point was definite or probable stent thrombosis. Secondary safety end points were cardiac death and target-vessel myocardial infarction. Five trials were identified, including a total of 9899 patients. Compared with EES, R-ZES had similar risks of target-vessel revascularization (risk ratio [RR], 1.06; 95% confidence interval [CI], 0.90-1.24; P=0.50), definite or probable stent thrombosis (RR, 1.26; 95% CI, 0.86-1.85; P=0.24), cardiac death (RR, 1.01; 95% CI, 0.79-1.30; P=0.91), and target-vessel myocardial infarction (RR, 1.10; 95% CI, 0.89-1.36; P=0.39). Moreover, R-ZES and EES had similar risks of late definite or probable very late stent thrombosis (RR, 1.06; 95% CI, 0.53-2.11; P=0.87). No evidence of significant heterogeneity was observed across trials. CONCLUSIONS R-ZES and EES provide similar safety and efficacy among patients undergoing percutaneous coronary intervention.
Resumo:
OBJECTIVES The purpose of this study was to compare the 2-year safety and effectiveness of new- versus early-generation drug-eluting stents (DES) according to the severity of coronary artery disease (CAD) as assessed by the SYNTAX (Synergy between Percutaneous Coronary Intervention with Taxus and Cardiac Surgery) score. BACKGROUND New-generation DES are considered the standard-of-care in patients with CAD undergoing percutaneous coronary intervention. However, there are few data investigating the effects of new- over early-generation DES according to the anatomic complexity of CAD. METHODS Patient-level data from 4 contemporary, all-comers trials were pooled. The primary device-oriented clinical endpoint was the composite of cardiac death, myocardial infarction, or ischemia-driven target-lesion revascularization (TLR). The principal effectiveness and safety endpoints were TLR and definite stent thrombosis (ST), respectively. Adjusted hazard ratios (HRs) with 95% confidence intervals (CIs) were calculated at 2 years for overall comparisons, as well as stratified for patients with lower (SYNTAX score ≤11) and higher complexity (SYNTAX score >11). RESULTS A total of 6,081 patients were included in the study. New-generation DES (n = 4,554) compared with early-generation DES (n = 1,527) reduced the primary endpoint (HR: 0.75 [95% CI: 0.63 to 0.89]; p = 0.001) without interaction (p = 0.219) between patients with lower (HR: 0.86 [95% CI: 0.64 to 1.16]; p = 0.322) versus higher CAD complexity (HR: 0.68 [95% CI: 0.54 to 0.85]; p = 0.001). In patients with SYNTAX score >11, new-generation DES significantly reduced TLR (HR: 0.36 [95% CI: 0.26 to 0.51]; p < 0.001) and definite ST (HR: 0.28 [95% CI: 0.15 to 0.55]; p < 0.001) to a greater extent than in the low-complexity group (TLR pint = 0.059; ST pint = 0.013). New-generation DES decreased the risk of cardiac mortality in patients with SYNTAX score >11 (HR: 0.45 [95% CI: 0.27 to 0.76]; p = 0.003) but not in patients with SYNTAX score ≤11 (pint = 0.042). CONCLUSIONS New-generation DES improve clinical outcomes compared with early-generation DES, with a greater safety and effectiveness in patients with SYNTAX score >11.
Resumo:
OBJECTIVE The aim of this study was to directly compare metal artifact reduction (MAR) of virtual monoenergetic extrapolations (VMEs) from dual-energy computed tomography (CT) with iterative MAR (iMAR) from single energy in pelvic CT with hip prostheses. MATERIALS AND METHODS A human pelvis phantom with unilateral or bilateral metal inserts of different material (steel and titanium) was scanned with third-generation dual-source CT using single (120 kVp) and dual-energy (100/150 kVp) at similar radiation dose (CT dose index, 7.15 mGy). Three image series for each phantom configuration were reconstructed: uncorrected, VME, and iMAR. Two independent, blinded radiologists assessed image quality quantitatively (noise and attenuation) and subjectively (5-point Likert scale). Intraclass correlation coefficients (ICCs) and Cohen κ were calculated to evaluate interreader agreements. Repeated measures analysis of variance and Friedman test were used to compare quantitative and qualitative image quality. Post hoc testing was performed using a corrected (Bonferroni) P < 0.017. RESULTS Agreements between readers were high for noise (all, ICC ≥ 0.975) and attenuation (all, ICC ≥ 0.986); agreements for qualitative assessment were good to perfect (all, κ ≥ 0.678). Compared with uncorrected images, VME showed significant noise reduction in the phantom with titanium only (P < 0.017), and iMAR showed significantly lower noise in all regions and phantom configurations (all, P < 0.017). In all phantom configurations, deviations of attenuation were smallest in images reconstructed with iMAR. For VME, there was a tendency toward higher subjective image quality in phantoms with titanium compared with uncorrected images, however, without reaching statistical significance (P > 0.017). Subjective image quality was rated significantly higher for images reconstructed with iMAR than for uncorrected images in all phantom configurations (all, P < 0.017). CONCLUSIONS Iterative MAR showed better MAR capabilities than VME in settings with bilateral hip prosthesis or unilateral steel prosthesis. In settings with unilateral hip prosthesis made of titanium, VME and iMAR performed similarly well.
Resumo:
PURPOSE To identify the influence of fixed prosthesis type on biologic and technical complication rates in the context of screw versus cement retention. Furthermore, a multivariate analysis was conducted to determine which factors, when considered together, influence the complication and failure rates of fixed implant-supported prostheses. MATERIALS AND METHODS Electronic searches of MEDLINE (PubMed), EMBASE, and the Cochrane Library were conducted. Selected inclusion and exclusion criteria were used to limit the search. Data were analyzed statistically with simple and multivariate random-effects Poisson regressions. RESULTS Seventy-three articles qualified for inclusion in the study. Screw-retained prostheses showed a tendency toward and significantly more technical complications than cemented prostheses with single crowns and fixed partial prostheses, respectively. Resin chipping and ceramic veneer chipping had high mean event rates, at 10.04 and 8.95 per 100 years, respectively, for full-arch screwed prostheses. For "all fixed prostheses" (prosthesis type not reported or not known), significantly fewer biologic and technical complications were seen with screw retention. Multivariate analysis revealed a significantly greater incidence of technical complications with cemented prostheses. Full-arch prostheses, cantilevered prostheses, and "all fixed prostheses" had significantly higher complication rates than single crowns. A significantly greater incidence of technical and biologic complications was seen with cemented prostheses. CONCLUSION Screw-retained fixed partial prostheses demonstrated a significantly higher rate of technical complications and screw-retained full-arch prostheses demonstrated a notably high rate of veneer chipping. When "all fixed prostheses" were considered, significantly higher rates of technical and biologic complications were seen for cement-retained prostheses. Multivariate Poisson regression analysis failed to show a significant difference between screw- and cement-retained prostheses with respect to the incidence of failure but demonstrated a higher rate of technical and biologic complications for cement-retained prostheses. The incidence of technical complications was more dependent upon prosthesis and retention type than prosthesis or abutment material.
Resumo:
BACKGROUND Little information is yet available on zirconia-based prostheses supported by implants. PURPOSE To evaluate technical problems and failures of implant-supported zirconia-based prostheses with exclusive screw-retention. MATERIAL AND METHODS Consecutive patients received screw-retained zirconia-based prostheses supported by implants and were followed over a time period of 5 years. The implant placement and prosthetic rehabilitation were performed in one clinical setting, and all patients participated in the maintenance program. The treatment comprised single crowns (SCs) and fixed dental prostheses (FDPs) of three to 12 units. Screw-retention of the CAD/CAM-fabricated SCs and FDPs was performed with direct connection at the implant level. The primary outcome was the complete failure of zirconia-based prostheses; outcome measures were fracture of the framework or extensive chipping resulting in the need for refabrication. A life table analysis was performed, the cumulative survival rate (CSR) calculated, and a Kaplan-Meier curve drawn. RESULTS Two hundred and ninety-four implants supported 156 zirconia-based prostheses in 95 patients (52 men, 43 women, average age 59.1 ± 11.7 years). Sixty-five SCs and 91 FDPs were identified, comprising a total of 441 units. Fractures of the zirconia framework and extensive chipping resulted in refabrication of nine prostheses. Nearly all the prostheses (94.2%) remained in situ during the observation period. The 5-year CSR was 90.5%, and 41 prostheses (14 SCs, 27 FDPs) comprising 113 units survived for an observation time of more than 5 years. Six SCs exhibited screw loosening, and polishing of minor chipping was required for five prostheses. CONCLUSIONS This study shows that zirconia-based implant-supported fixed prostheses exhibit satisfactory treatment outcomes and that screw-retention directly at the implant level is feasible.
Resumo:
BACKGROUND The safety and efficacy of new-generation drug-eluting stents (DES) in women with multiple atherothrombotic risk (ATR) factors is unclear. METHODS AND RESULTS We pooled patient-level data for women enrolled in 26 randomized trials. Study population was categorized based on the presence or absence of high ATR, which was defined as having history of diabetes mellitus, prior percutaneous or surgical coronary revascularization, or prior myocardial infarction. The primary end point was major adverse cardiovascular events defined as a composite of all-cause mortality, myocardial infarction, or target lesion revascularization at 3 years of follow-up. Out of 10 449 women included in the pooled database, 5333 (51%) were at high ATR. Compared with women not at high ATR, those at high ATR had significantly higher risk of major adverse cardiovascular events (15.8% versus 10.6%; adjusted hazard ratio: 1.53; 95% confidence interval: 1.34-1.75; P=0.006) and all-cause mortality. In high-ATR risk women, the use of new-generation DES was associated with significantly lower risk of 3-year major adverse cardiovascular events (adjusted hazard ratio: 0.69; 95% confidence interval: 0.52-0.92) compared with early-generation DES. The benefit of new-generation DES on major adverse cardiovascular events was uniform between high-ATR and non-high-ATR women, without evidence of interaction (Pinteraction=0.14). At landmark analysis, in high-ATR women, stent thrombosis rates were comparable between DES generations in the first year, whereas between 1 and 3 years, stent thrombosis risk was lower with new-generation devices. CONCLUSIONS Use of new-generation DES even in women at high ATR is associated with a benefit consistent over 3 years of follow-up and a substantial improvement in very-late thrombotic safety.
Resumo:
BACKGROUND In percutaneous coronary intervention (PCI) patients new-generation drug-eluting stent (DES) has reduced adverse events in comparison to early-generation DES. The aim of the current study was to investigate the long-term clinical efficacy and safety of new-generation DES versus early-generation DES for PCI of unprotected left main coronary artery (uLMCA) disease. METHODS The patient-level data from the ISAR-LEFT MAIN and ISAR-LEFT MAIN 2 randomized trials were pooled. The clinical outcomes of PCI patients assigned to new-generation DES (everolimus- or zotarolimus-eluting stent) versus early-generation DES (paclitaxel- or sirolimus-eluting stent) were studied. The primary endpoint was the composite of death, myocardial infarction (MI), target lesion revascularization and stroke (MACCE, major adverse cardiac and cerebrovascular event). RESULTS In total, 1257 patients were available. At 3 years, the risk of MACCE was comparable between patients assigned to new-generation DES or early-generation DES (28.2 versus 27.5 %, hazard ratio-HR 1.03, 95 % confidence intervals-CI 0.83-1.26; P = 0.86). Definite/probable stent thrombosis was low and comparable between new-generation DES and early-generation DES (0.8 versus 1.6 %, HR 0.52, 95 % CI 0.18-1.57; P = 0.25); in patients treated with new-generation DES no cases occurred beyond 30 days. Diabetes increased the risk of MACCE in patients treated with new-generation DES but not with early-generation DES (P interaction = 0.004). CONCLUSIONS At 3-year follow-up, a PCI with new-generation DES for uLMCA disease shows comparable efficacy to early-generation DES. Rates of stent thrombosis were low in both groups. Diabetes significantly impacts the risk of MACCE at 3 years in patients treated with new-generation DES for uLMCA disease. ClinicalTrials.gov Identifiers: NCT00133237; NCT00598637.
Resumo:
The purpose of this study was to evaluate the incidence of corrosion and fretting in 48 retrieved titanium-6aluminum-4vanadium and/or cobalt-chromium-molybdenum modular total hip prosthesis with respect to alloy material microstructure and design parameters. The results revealed vastly different performance results for the wide array of microstructures examined. Severe corrosion/fretting was seen in 100% of as-cast, 24% of low carbon wrought, 9% of high carbon wrought and 5% of solution heat treated cobalt-chrome. Severe corrosion/fretting was observed in 60% of Ti-6Al-4V components. Design features which allow for fluid entry and stagnation, amplification of contact pressure and/or increased micromotion were also shown to play a role. 75% of prosthesis with high femoral head-trunnion offset exhibited poor performance compared to 15% with a low offset. Large femoral heads (>32mm) did not exhibit poor corrosion or fretting. Implantation time was not sufficient to cause poor performance; 54% of prosthesis with greater than 10 years in-vivo demonstrated none or mild corrosion/fretting.
Resumo:
The aim of this study was to develop a practical, versatile and fast dosimetry and radiobiological model for calculation of the 3D dose distribution and radiobiological effectiveness of radioactive stents. The algorithm was written in Matlab 6.5 programming language and is based on the dose point kernel convolution. The dosimetry and radiobiological model was applied for evaluation of the 3D dose distribution of 32P, 90Y, 188Re and 177Lu stents. Of the four, 32P delivers the highest dose, while 90Y, 188Re and 177Lu require high levels of activity to deliver a significant therapeutic dose in the range of 15-30 Gy. Results of the radiobiological model demonstrated that the same physical dose delivered by different radioisotopes produces significantly different radiobiological effects. This type of theoretical dose calculation can be useful in the development of new stent designs, the planning of animal studies and clinical trials, and clinical decisions involving individualized treatment plans.
Resumo:
Background and objective: Drainage with metallic stents is the treatment of choice in malignant obstructive jaundice. Technical and clinical success with metallic stents is obtained in over 90% and 80% of cases, respectively. There are self-expandable metallic stents designed to increase permeability. The aim of this study was to describe the results obtained with totally covered self-expandable and uncovered self-expandable metallic stents in the palliative treatment of malignant biliary obstruction. Patients and methods: Sixty eight patients with malignant obstructive jaundice secondary to pancreatobiliary or metastatic disease not amenable to surgery were retrospectively included. Two groups were created: group A (covered self-expandable metallic stents) (n = 22) and group B (uncovered self-expandable metallic stents) (n = 46). Results: Serum total bilirubin, direct bilirubin, alkaline phosphatase and gamma glutamyl transferase levels decreased in both groups and no statistically significant difference was detected (p = 0.800, p = 0.190, p = 0.743, p = 0.521). Migration was greater with covered stents but it was not statistically significant either (p = 0.101). Obstruction was greater in the group with uncovered stents but it was not statistically significant either (p = 0.476). Conclusion: There are no differences when using covered self-expandable stents or uncovered self-expandable stents in terms of technical and clinical success or complications in the palliative treatment of malignant obstructive jaundice.
Resumo:
Objectives: To investigate patients' mobility and satisfaction with their lower-limb prosthetic or orthotic device and related service delivery in Sierra Leone; to compare groups of patients regarding type and level of assistive device, gender, area of residence, income; and to identify factors associated with satisfaction with the assistive device and service. Methods: A total of 139 patients answered questionnaires, including the Quebec User Evaluation of Satisfaction with Assistive Technology questionnaire (QUEST 2.0). Results: Eighty-six percent of assistive devices were in use, but half needed repair. Thirty-three percent of patients reported pain when using their assistive device. Patients had difficulties or could not walk at all on: uneven ground (65%); hills (75%); and stairs (66%). Patients were quite satisfied with their assistive device and the service (mean 3.7 out of 5 in QUEST), but reported 886 problems. Approximately half of the patients could not access services. In relation to mobility and service delivery, women, orthotic patients and patients using above-knee assistive devices had the poorest results. The general condition of the assistive device and patients' ability to walk on uneven ground were associated with satisfaction with the assistive devices and service. Conclusion: Patients reported high levels of mobility while using their device although they experienced pain and difficulties walking on challenging surfaces. Limitations in the effectiveness of assistive devices and limited access to follow-up services and repairs were issues desired to be addressed.
Resumo:
The aim of this study was to evaluate by photoelastic analysis stress distribution on short and long implants of two dental implant systems with 2-unit implant-supported fixed partial prostheses of 8 mm and 13 mm heights. Sixteen photoelastic models were divided into 4 groups: I: long implant (5 × 11 mm) (Neodent), II: long implant (5 × 11 mm) (Bicon), III: short implant (5 × 6 mm) (Neodent), and IV: short implants (5 × 6 mm) (Bicon). The models were positioned in a circular polariscope associated with a cell load and static axial (0.5 Kgf) and nonaxial load (15°, 0.5 Kgf) were applied to each group for both prosthetic crown heights. Three-way ANOVA was used to compare the factors implant length, crown height, and implant system (α = 0.05). The results showed that implant length was a statistically significant factor for both axial and nonaxial loading. The 13 mm prosthetic crown did not result in statistically significant differences in stress distribution between the implant systems and implant lengths studied, regardless of load type (P > 0.05). It can be concluded that short implants showed higher stress levels than long implants. Implant system and length was not relevant factors when prosthetic crown height were increased.
Resumo:
OBJECTIVES: The purpose of this in vitro study was to evaluate misfit alterations at the implant/abutment interface of external and internal connection implant systems when subjected to cyclic loading. MATERIAL AND METHODS: Standard metal crowns were fabricated for 5 groups (n=10) of implant/abutment assemblies: Group 1, external hexagon implant and UCLA cast-on premachined abutment; Group 2, internal hexagon implant and premachined abutment; Group 3, internal octagon implant and prefabricated abutment; Group 4, external hexagon implant and UCLA cast-on premachined abutment; and Group 5, external hexagon implant and Ceraone abutment. For groups 1, 2, 3 and 5, the crowns were cemented on the abutments and in group 4 crowns were screwed directly on the implant. The specimens were subjected to 500,000 cycles at 19.1 Hz of frequency and non-axial load of 133 N in a MTS 810 machine. The vertical misfit (μm) at the implant/abutment interface was evaluated before (B) and after (A) application of the cyclic loading. Data were analyzed statistically by using two-away ANOVA and Tukey's post-hoc test (p<0.05). RESULTS: Before loading values showed no difference among groups 2 (4.33±3.13), 3 (4.79±3.43) and 5 (3.86±4.60); between groups 1 (12.88±6.43) and 4 (9.67±3.08), and among groups 2, 3 and 4. However, groups 1 and 4 were significantly different from groups 2, 3 and 5. After loading values of groups 1 (17.28±8.77) and 4 (17.78±10.99) were significantly different from those of groups 2 (4.83±4.50), 3 (8.07±4.31) and 5 (3.81±4.84). There was a significant increase in misfit values of groups 1, 3 and 4 after cyclic loading, but not for groups 2 and 5. CONCLUSIONS: The cyclic loading and type of implant/abutment connection may develop a role on the vertical misfit at the implant/abutment interface.