948 resultados para Speckle tracking liver motion correction contrast-enhanced ultrasound
Resumo:
Este relato apresenta o seguimento tardio de um caso de cardiomiopatia de Takotsubo com boa evolução clínica e melhora da função sistólica global ventricular esquerda. Contudo, observou-se persistência de significativa disfunção sistólica regional longitudinal que foi avaliada por meio de nova técnica ecocardiográfica (speckle tracking), com as medidas do strain (S) e strain rate (SR) correspondentes. Ressaltamos a importância desse novo método para o acompanhamento dessa cardiopatia, pois permite identificar os pacientes que persistem com disfunção sistólica e que possivelmente serão beneficiados com a manutenção da terapêutica clínica.
Resumo:
A exequibilidade e o potencial para investigar o coração, sob o ponto de vista morfológico e hemodinâmico, vêm aumentando a aplicação da ecocardiografia na pesquisa. Além disso, o desenvolvimento de novas tecnologias, tais como a ecocardiografia tridimensional em tempo real e o speckle tracking, requerem validação por meio de estudos experimentais antes de serem instituídas no cenário clínico. O presente artigo objetiva fornecer informações acerca das particularidades do estudo ecocardiográfico nos mamíferos quadrúpedes, com vistas à pesquisa experimental.
Resumo:
Fundamento: A doença cardiovascular subclínica é prevalente em pacientes com síndrome metabólica (SM). O strain circunferencial (εCC) e o strain longitudinal (εLL) do ventriculo esquerdo (VE), avaliados pelo ecocardiograma com speckle tracking (STE), são índices de função sistólica: o encurtamento das fibras circunferenciais e longitudinais do VE é indicado por um valor negativo do strain. Portanto, quanto mais negativo o strain, melhor a função sistólica do VE. O εCC e o εLL têm sido usados para demonstrar disfunção ventricular subclínica em vários distúrbios clínicos. Objetivo: Levantamos a hipótese de que a SM está associada com comprometimento da função miocárdica, quando avaliada pelo STE. Métodos: Este estudo analisou participantes do Multi-Ethnic Study of Atherosclerosis (MESA) que realizaram o STE e foram avaliados para todos os componentes da SM. Resultados: Entre os 133 participantes incluídos (mulheres: 63%; idade: 65 ± 9 anos), a prevalência de SM foi de 31% (41/133). Indivíduos com SM apresentaram valores menores do εCC e do εLL que aqueles sem SM (-16,3% ± 3,5% vs. -18,4% ± 3,7%, p < 0,01; e -12,1% ± 2,5% vs. -13,9% ± 2,3%, p < 0,01, respectivamente). A fração de ejeção do VE (FEVE) foi semelhante nos dois grupos (p = 0,09). Na análise multivariada, a SM associou-se a um valor mais baixo do strain circunferencial (B = 2,1%, IC 95%: 0,6-3,5; p < 0,01), mesmo após ajuste para idade, etnia, massa VE e FEVE. De maneira semelhante, a presença de SM (B = 1,3%, IC 95%: 0,3-2,2; p < 0,01) e a massa do VE (B = 0,02%, IC 95%: 0,01 0,03; p = 0,02) associaram-se a um valor menor do strain longitudinal após ajuste para etnia, FEVE e creatinina. Conclusão: O εCC e o εLL do VE, marcadores de doença cardiovascular subclínica, estão comprometidos em indivíduos assintomáticos com SM e sem história prévia de infarto miocárdico, insuficiência cardíaca e/ou de FEVE < 50%.
Resumo:
OBJECTIVE: Contemporary free-breathing non contrast enhanced cardiovascular magnetic resonance angiography (CMRA) was qualitatively and quantitatively evaluated to ascertain the reproducibility of the method for coronary artery luminal dimension measurements. SUBJECTS AND METHODS: Twenty-two healthy volunteers (mean age 32 +/- 7 years, 12 males) without coronary artery disease were imaged at 2 centers (1 each in Europe and North America) using navigator-gated and corrected SSFP CMRA on a commercial whole body 1.5T System. Repeat images of right (RCA, n = 21), left anterior descending (LAD, n = 14) and left circumflex (LCX, n = 14) coronary arteries were obtained in separate sessions using identical scan protocol and imaging parameters. True visible vessel length, signal-to-noise (SNR), contrast-to-noise ratios (CNR) and the average luminal diameter over the first 4 cm of the vessel were measured. Intra-observer, inter-observer and inter-scan reproducibility of coronary artery luminal diameter were determined using Pearson's correlation, Bland-Altman analysis and intraclass correlation coefficients (ICC). RESULTS: CNR, SNR and the mean length of the RCA, LAD and LCX imaged for original and repeat scans were not significantly different (all p > 0.30). There was a high degree of intra-observer, inter-observer and inter-scan agreements for RCA, LAD and LCX luminal diameter respectively on Bland-Altman and ICC analysis (ICC's for RCA: 0.98. 0.98 and 0.86; LAD: 0.89, 0.89 and 0.63; LCX: 0.95, 0.94 and 0.79). CONCLUSION: In a 2-center study, we demonstrate that free-breathing 3D SSFP CMRA can visualize long continuous segments of coronary vessels with highly reproducible measurements of luminal diameter.
Resumo:
A cardiac-triggered free-breathing three-dimensional (3D) balanced fast field-echo projection renal magnetic resonance (MR) angiographic sequence was investigated for in-stent lumen visualization of a dedicated metallic renal artery stent. Fourteen prototype stents were deployed in the renal arteries of six pigs (in two pigs, three stents were deployed). Projection renal MR angiography was compared with standard contrast material-enhanced 3D breath-hold MR angiography. Artifact-free in-stent lumen visualization was achieved with both projection MR angiography and contrast-enhanced MR angiography. These promising results warrant further studies for visualization of in-stent restenosis.
Resumo:
L`electrocardiograma és la primera eina diagnòstica fàcilment disponible per la detecció de l´infart a la práctica clínica. El seu valor va ser donat principalment amb estudis antics anatomopatològics. La ressonància magnètica cardíaca actualment és la tècnica d`elecció per la detecció de l`infart. Aquest estudi investiga el valor de l`electrocardiograma ( sensibilitat i especificitat) per detectar infarts de la zona anteroseptal. Conclusiò: la sensibilitat y la especificitat de quatre patents electrocardiogràfiques de la zona anteroseptal va ser valorada. Així mateix, encara que s`observin extenses ones Q en les derivacions anteriors la necrosis és usualment limitada si VL no está afectat. 3
Resumo:
Estudi realitzat a partir d’una estada a la Stanford University School of Medicine. Division of Radiation Oncology, Estats Units, entre 2010 i 2012. Durant els dos anys de beca postdoctoral he estat treballant en dos projectes diferents. En primer lloc, i com a continuació d'estudis previs del grup, volíem estudiar la causa de les diferències en nivells d'hipòxia que havíem observat en models de càncer de pulmó. La nostra hipòtesi es basava en el fet que aquestes diferències es devien a la funcionalitat de la vasculatura. Vam utilitzar dos models preclínics: un en què els tumors es formaven espontàniament als pulmons i l'altre on nosaltres injectàvem les cèl•lules de manera subcutània. Vam utilitzar tècniques com la ressonància magnètica dinàmica amb agent de contrast (DCE-MRI) i l'assaig de perfusió amb el Hoeschst 33342 i ambdues van demostrar que la funcionalitat de la vasculatura dels tumors espontanis era molt més elevada comparada amb la dels tumors subcutanis. D'aquest estudi, en podem concloure que les diferències en els nivells d'hipòxia en els diferents models tumorals de càncer de pulmó podrien ser deguts a la variació en la formació i funcionalitat de la vasculatura. Per tant, la selecció de models preclínics és essencial, tant pels estudi d'hipòxia i angiogènesi, com per a teràpies adreçades a aquests fenòmens. L'altre projecte que he estat desenvolupant es basa en l'estudi de la radioteràpia i els seus possibles efectes a l’hora de potenciar l'autoregeneració del tumor a partir de les cèl•lules tumorals circulants (CTC). Aquest efecte s'ha descrit en alguns models tumorals preclínics. Per tal de dur a terme els nostres estudis, vam utilitzar una línia tumoral de càncer de mama de ratolí, marcada permanentment amb el gen de Photinus pyralis o sense marcar i vam fer estudis in vitro i in vivo. Ambdós estudis han demostrat que la radiació tumoral promou la invasió cel•lular i l'autoregeneració del tumor per CTC. Aquest descobriment s'ha de considerar dins d'un context de radioteràpia clínica per tal d'aconseguir el millor tractament en pacients amb nivells de CTC elevats.
Resumo:
BACKGROUND: Radiation dose exposure is of particular concern in children due to the possible harmful effects of ionizing radiation. The adaptive statistical iterative reconstruction (ASIR) method is a promising new technique that reduces image noise and produces better overall image quality compared with routine-dose contrast-enhanced methods. OBJECTIVE: To assess the benefits of ASIR on the diagnostic image quality in paediatric cardiac CT examinations. MATERIALS AND METHODS: Four paediatric radiologists based at two major hospitals evaluated ten low-dose paediatric cardiac examinations (80 kVp, CTDI(vol) 4.8-7.9 mGy, DLP 37.1-178.9 mGy·cm). The average age of the cohort studied was 2.6 years (range 1 day to 7 years). Acquisitions were performed on a 64-MDCT scanner. All images were reconstructed at various ASIR percentages (0-100%). For each examination, radiologists scored 19 anatomical structures using the relative visual grading analysis method. To estimate the potential for dose reduction, acquisitions were also performed on a Catphan phantom and a paediatric phantom. RESULTS: The best image quality for all clinical images was obtained with 20% and 40% ASIR (p < 0.001) whereas with ASIR above 50%, image quality significantly decreased (p < 0.001). With 100% ASIR, a strong noise-free appearance of the structures reduced image conspicuity. A potential for dose reduction of about 36% is predicted for a 2- to 3-year-old child when using 40% ASIR rather than the standard filtered back-projection method. CONCLUSION: Reconstruction including 20% to 40% ASIR slightly improved the conspicuity of various paediatric cardiac structures in newborns and children with respect to conventional reconstruction (filtered back-projection) alone.
Resumo:
Due to their relatively small size and central location within the thorax, improvement in signal-to-noise (SNR) is of paramount importance for in vivo coronary vessel wall imaging. Thus, with higher field strengths, coronary vessel wall imaging is likely to benefit from the expected "near linear" proportional gain in SNR. In this study, we demonstrate the feasibility of in vivo human high field (3 T) coronary vessel wall imaging using a free-breathing black blood fast gradient echo technique with respiratory navigator gating and real-time motion correction. With the broader availability of more SNR efficient fast spin echo and spiral techniques, further improvements can be expected.
Resumo:
PURPOSE: This study was performed to determine the impact of perfusion and diffusion magnetic resonance imaging (MRI) sequences on patients during treatment of newly diagnosed glioblastoma. Special emphasis has been given to these imaging technologies as tools to potentially anticipate disease progression, as progression-free survival is frequently used as a surrogate endpoint. METHODS AND MATERIALS: Forty-one patients from a phase II temolozomide clinical trial were included. During follow-up, images were integrated 21 to 28 days after radiochemotherapy and every 2 months thereafter. Assessment of scans included measurement of size of lesion on T1 contrast-enhanced, T2, diffusion, and perfusion images, as well as mass effect. Classical criteria on tumor size variation and clinical parameters were used to set disease progression date. RESULTS: A total of 311 MRI examinations were reviewed. At disease progression (32 patients), a multivariate Cox regression determined 2 significant survival parameters: T1 largest diameter (p < 0.02) and T2 size variation (p < 0.05), whereas perfusion and diffusion were not significant. CONCLUSION: Perfusion and diffusion techniques cannot be used to anticipate tumor progression. Decision making at disease progression is critical, and classical T1 and T2 imaging remain the gold standard. Specifically, a T1 contrast enhancement over 3 cm in largest diameter together with an increased T2 hypersignal is a marker of inferior prognosis.
Resumo:
Radioimmunotherapies with Zevalin® (RIT-Z) showed encouraging results in patients with relapsed/refractory follicular lymphoma (FL), leading frequently to failure-free intervals longer than those achieved by the last previous therapy. We compared time-to-event variables obtained before and after RIT-Z in patients with relapsed FL, previously exposed to rituximab. All patients with relapsed non-transformed, non-refractory, non-rituximab-naïve FL who have been treated with RIT-Z in two different centres in Europe were included. Staging and response were assessed by contrast-enhanced CT in all patients; PET/CT was performed according to local availability. Event-free survival (EFS) and time to next treatment (TTNT) following the last previous therapy and after RIT-Z were compared. Pre-therapy characteristics were tested in univariate analyses for prediction of outcomes. A description of the patterns of relapse was also provided. Among 70 patients treated, only 16 fulfilled the inclusion criteria. They were treated with a median of 3 prior lines of chemo-immunotherapies, including a median of 2 rituximab-containing regimens; 6 patients had undergone myeloablative chemotherapy with autologous stem cell rescue (ASCT). Overall response rates were 10 (62%) CR/CRu, 3 (19%) PR and 3 (19%) PD; response rates were similar in patients with prior ASCT. After RIT-Z only few patients obtained EFS and TTNT longer than after the last previous therapy. All four patients receiving rituximab maintenance were without progression 12 months after RIT-Z. Relapses occurred in both previously and newly involved sites; a significant association was found between the number of pathologic sites involved prior to RIT-Z and subsequent TTNT. Despite the excellent response rate, the duration of response was shorter than the previous one confirming the known trend of relapses to occur earlier after subsequent treatments. Rituximab maintenance after RIT-Z showed encouraging results in terms of prolonging EFS, warranting further studies. Copyright © 2010 John Wiley & Sons, Ltd.
Resumo:
The impact of navigator spatial resolution and navigator evaluation time on image quality in free-breathing navigator-gated 3D coronary magnetic resonance angiography (MRA), including real-time motion correction, was investigated in a moving phantom. Objective image quality parameters signal-to-noise ratio (SNR) and vessel sharpness were compared. It was found that for improved mage quality a short navigator evaluation time is of crucial importance. Navigator spatial resolution showed minimal influence on image quality.
Resumo:
OBJECTIVES: To assess the accuracy of high-resolution (HR) magnetic resonance imaging (MRI) in diagnosing early-stage optic nerve (ON) invasion in a retinoblastoma cohort. METHODS: This IRB-approved, prospective multicenter study included 95 patients (55 boys, 40 girls; mean age, 29 months). 1.5-T MRI was performed using surface coils before enucleation, including spin-echo unenhanced and contrast-enhanced (CE) T1-weighted sequences (slice thickness, 2 mm; pixel size <0.3 × 0.3 mm(2)). Images were read by five neuroradiologists blinded to histopathologic findings. ROC curves were constructed with AUC assessment using a bootstrap method. RESULTS: Histopathology identified 41 eyes without ON invasion and 25 with prelaminar, 18 with intralaminar and 12 with postlaminar invasion. All but one were postoperatively classified as stage I by the International Retinoblastoma Staging System. The accuracy of CE-T1 sequences in identifying ON invasion was limited (AUC = 0.64; 95 % CI, 0.55 - 0.72) and not confirmed for postlaminar invasion diagnosis (AUC = 0.64; 95 % CI, 0.47 - 0.82); high specificities (range, 0.64 - 1) and negative predictive values (range, 0.81 - 0.97) were confirmed. CONCLUSION: HR-MRI with surface coils is recommended to appropriately select retinoblastoma patients eligible for primary enucleation without the risk of IRSS stage II but cannot substitute for pathology in differentiating the first degrees of ON invasion. KEY POINTS: • HR-MRI excludes advanced optic nerve invasion with high negative predictive value. • HR-MRI accurately selects patients eligible for primary enucleation. • Diagnosis of early stages of optic nerve invasion still relies on pathology. • Several physiological MR patterns may mimic optic nerve invasion.
Resumo:
BACKGROUND: Laparoscopic enucleation for neuroendocrine pancreatic tumors has become a feasible technique, with a reported incidence of pancreatic fistula ranging from 13 to 29 %.1 (-) 3 This report describes the first successful case of laparoscopic pancreatic enucleation with resection of the main pancreatic duct followed by end-to-end anastomosis. METHODS: A 41-year-old woman was admitted to the authors' hospital for repeated syncope. Hypoglycemia also was noted. A contrast-enhanced computed tomography examination showed a highly enhanced tumor measuring 22 mm in diameter on the ventral side of the pancreatic body adjacent to the main pancreatic duct. The patient's blood insulin level was elevated, and her diagnosis was determined to be pancreatic insulinoma. Laparoscopic pancreatic enucleation was performed. Approximately 2 cm of the main pancreatic duct was segmentally resected, and a short stent (Silicone tube: Silastic, Dow Corning Corporation, Midland, MI) was inserted. The direct anastomosis of the main pancreatic duct was performed using four separate sutures with an absorbable monofilament (6-0 PDS). RESULTS: The operation time was 166 min, and the estimated blood loss was 100 mL. The postoperative course was uneventful, and the patient was discharged from hospital on postoperative day 7. The pathologic findings showed a well-differentiated insulinoma and a negative surgical margin. A computed tomography examination performed 1 month after the operation showed a successful anastomosis with a patent main pancreatic duct. CONCLUSIONS: Laparoscopic segmental resection of the main pancreatic duct and end-to-end anastomosis can be performed safely with the insertion of a short stent. This technique also can be used for a central pancreatectomy.
Resumo:
Traditionally, thoracic aortic rupture, suspected after blunt thoracic trauma, is characterized by a chest radiograph showing a widened mediastinum. The diagnostic machinery consecutively activated still depends heavily on the pressure as additional traumatic lesions. A patient with additional cranio-cerebral trauma would typically undergo contrast-enhanced computed tomography or magnetic resonance imaging of head, chest, and other regions. In a number of patients these analyses would confirm the presence of blood in the mediastinum without formal proof of an aortic disruption. This is because mediastinal hematomas may be caused not only by an aortic rupture, but also by numerous other blood sources including fractures of the spine and other macro- and microvascular lesions providing similar images. Therefore, aortic angiography became our preferred diagnostic tool to identify or rule out acute traumatic lesions of not only the aorta but with great vessels. However recently, a number of traumatic aortic transsections have been identified by transoesophageal echocardiography (TEE). TEE has the additional advantage of being a bed-side procedure providing additional information about cardiac function. The latter analysis allows for identification and quantification of cardiac contusions, post-traumatic myocardial infarctions, and valvar lesions which are of prime importance to develop an adequate surgical strategy and to assess the risk of the numerous emergency procedures required in patients with polytrauma. The standard approach for repair of isthmic aortic rupture is through a lateral thoracotomy. Distal and proximal control of the aorta can be achieved in a substantial number of cases before complete aortic rupture occurs and a higher proportion of direct suture repair can be achieved under such circumstances. Most proximal descending aortic procedures are performed without cardiopulmonary bypass (clamp and go) but paraplegia may occur before, during, or after the procedure. Ascending aortic lesions and disruption of the aortic arch, the supra-aortic vessels, the main pulmonary arteries, the great veins as well as cardiac lesions are best approached through a sternotomy, which may have to be extended. Cardiopulmonary bypass allowing for deep hypothermia and circulatory arrest is often required and carries its own complications. It is not clear whether the increasing proportion of ascending aortic and cardiac lesions which are observed nowadays are due to a change in trauma mechanics (i.e., speed limits, seat belts, air-bags), an improvement of the diagnostic tools or both.