889 resultados para Solar Thermal Collector


Relevância:

40.00% 40.00%

Publicador:

Resumo:

To achieve high efficiency, the intermediate band (IB) solar cell must generate photocurrent from sub-bandgap photons at a voltage higher than that of a single contributing sub-bandgap photon. To achieve the latter, it is necessary that the IB levels be properly isolated from the valence and conduction bands. We prove that this is not the case for IB cells formed with the confined levels of InAs quantum dots (QDs) in GaAs grown so far due to the strong density of internal thermal photons at the transition energies involved. To counteract this, the QD must be smaller.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The heterogeneous incoming heat flux in solar parabolic trough absorber tubes generates huge temperature difference in each pipe section. Helical internal fins can reduce this effect, homogenising the temperature profile and reducing thermal stress with the drawback of increasing pressure drop. Another effect is the decreasing of the outer surface temperature and thermal losses, improving the thermal efficiency of the collector. The application of internal finned tubes for the design of parabolic trough collectors is analysed with computational fluid dynamics tools. Our numerical approach has been qualified with the computational estimation of reported experimental data regarding phenomena involved in finned tube applications and solar irradiation of parabolic trough collector. The application of finned tubes to the design of parabolic trough collectors must take into account issues as the pressure losses, thermal losses and thermo-mechanical stress, and thermal fatigue. Our analysis shows an improvement potential in parabolic trough solar plants efficiency by the application of internal finned tubes.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Sunrise is a solar telescope, successfully flown in June 2009 with a long duration balloon from the Swedish Space Corporation Esrange launch site. The design of the thermal control of SUNRISE was quite critical because of the sensitivity to temperature of the optomechanical devices and the electronics. These problems got more complicated due the size and high power dissipation of the system. A detailed thermal mathematical model of SUNRISE was set up to predict temperatures. In this communication the thermal behaviour of SUNRISE during flight is presented. Flight temperatures of some devices are presented and analysed. The measured data have been compared with the predictions given by the thermal mathematical models. The main discrepancies between flight data and the temperatures predicted by the models have been identified. This allows thermal engineers to improve the knowledge of the thermal behaviour of the system for future missions.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Polysilicon production costs contribute approximately to 25-33% of the overall cost of the solar panels and a similar fraction of the total energy invested in their fabrication. Understanding the energy losses and the behaviour of process temperature is an essential requirement as one moves forward to design and build large scale polysilicon manufacturing plants. In this paper we present thermal models for two processes for poly production, viz., the Siemens process using trichlorosilane (TCS) as precursor and the fluid bed process using silane (monosilane, MS).We validate the models with some experimental measurements on prototype laboratory reactors relating the temperature profiles to product quality. A model sensitivity analysis is also performed, and the efects of some key parameters such as reactor wall emissivity, gas distributor temperature, etc., on temperature distribution and product quality are examined. The information presented in this paper is useful for further understanding of the strengths and weaknesses of both deposition technologies, and will help in optimal temperature profiling of these systems aiming at lowering production costs without compromising the solar cell quality.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

SUNRISE is a balloon-borne solar telescope flown with a long-duration balloon by NASA's Columbia Scientific Balloon Facility team from Esrange (Swedish Space Corporation), on 8 June 2009. SUNRISE has been a challenging mission from the thermal point of view because of its size and power dissipation. Thus, a dedicated thermal analysis has been carried out to find a solution that allows all the devices to be kept within their appropriate temperature ranges, without exceeding the allowable temperature gradients, critical for optical devices. In this article, the thermal design of SUNRISE is described. A geometrical mathematical model and a thermal mathematical model of the whole system have been set up for the different load cases in order to obtain the temperature distribution and gradients in the system. Some trade-offs have been necessary to fulfil all the thermal requirements. The thermal hardware used to achieve it is described. Finally, the temperatures obtained with the models have been compared with flight data.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

SUNRISE is a balloon-borne solar telescope flown with a long-duration balloon by NASA's Columbia Scientific Balloon Facility team from Esrange (Swedish Space Corporation), on 8 June 2009. SUNRISE has been a challenging mission from the thermal point of view because of its size and power dissipation. Thus, a dedicated thermal analysis has been carried out to find a solution that allows all the devices to be kept within their appropriate temperature ranges, without exceeding the allowable temperature gradients, critical for optical devices. In this article, the thermal design of SUNRISE is described. A geometrical mathematical model and a thermal mathematical model of the whole system have been set up for the different load cases in order to obtain the temperature distribution and gradients in the system. Some trade-offs have been necessary to fulfil all the thermal requirements. The thermal hardware used to achieve it is described. Finally, the temperatures obtained with the models have been compared with flight data.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

March 1979.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

"January 1981."

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study is an attempt at achieving Net Zero Energy Building (NZEB) using a solar Organic Rankine Cycle (ORC) based on exergetic and economic measures. The working fluid, working conditions of the cycle, cycle configuration, and solar collector type are considered the optimization parameters for the solar ORC system. In the first section, a procedure is developed to compare ORC working fluids based on their molecular components, temperature-entropy diagram and fluid effects on the thermal efficiency, net power generated, vapor expansion ratio, and exergy efficiency of the Rankine cycle. Fluids with the best cycle performance are recognized in two different temperature levels within two different categories of fluids: refrigerants and non-refrigerants. Important factors that could lead to irreversibility reduction of the solar ORC are also investigated in this study. In the next section, the system requirements needed to maintain the electricity demand of a geothermal air-conditioned commercial building located in Pensacola of Florida is considered as the criteria to select the optimal components and optimal working condition of the system. The solar collector loop, building, and geothermal air conditioning system are modeled using TRNSYS. Available electricity bills of the building and the 3-week monitoring data on the performance of the geothermal system are employed to calibrate the simulation. The simulation is repeated for Miami and Houston in order to evaluate the effect of the different solar radiations on the system requirements. The final section discusses the exergoeconomic analysis of the ORC system with the optimum performance. Exergoeconomics rests on the philosophy that exergy is the only rational basis for assigning monetary costs to a system’s interactions with its surroundings and to the sources of thermodynamic inefficiencies within it. Exergoeconomic analysis of the optimal ORC system shows that the ratio Rex of the annual exergy loss to the capital cost can be considered a key parameter in optimizing a solar ORC system from the thermodynamic and economic point of view. It also shows that there is a systematic correlation between the exergy loss and capital cost for the investigated solar ORC system.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Concrete solar collectors offer a type of solar collector with structural, aesthetic and economic advantages over current populartechnologies. This study examines the influential parameters of concrete solar collectors. In addition to the external conditions,the performance of a concrete solar collector is influenced by the thermal properties of the concrete matrix, piping network andfluid. Geometric and fluid flow parameters also influence the performance of the concrete solar collector. A literature review ofconcrete solar collectors is conducted in order to define the benchmark parameters from which individual parameters are thencompared. The numerical model consists of a 1D pipe flow network coupled with the heat transfer in a 3D concrete domain. Thispaper is concerned with the physical parameters that define the concrete solar collector, thus a constant surface temperature isused as the exposed surface boundary condition with all other surfaces being insulated. Results show that, of the parametersinvestigated, the pipe spacing, ps, concrete conductivity, kc, and the pipe embedment depth, demb, are among those parameterswhich have greatest effect on the collector’s performance. The optimum balance between these parameters is presented withrespect to the thermal performance and discussed with reference to practical development issues.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The presented work is related to the use of solar energy for the needs of heating and electricity for a single house located in Poland. Electricity will provided by energy conversion in the turbine by means of Organic Rankine Cycle (ORC), in which the operating medium (water heated in solar collector) is heating refrigerator in the heating exchanger. The solar installation is integrated with heat accumulator and wood boiler, which is used in the situation that collector is not enough to fill requirements of thermal comfort. There are chosen also all the necessary components of the system. In the work is also performed the economic assessment, by F chart method, to evaluate the profitability of the project, taking into total costs and savings.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Tesi hau Solarus AB enpresaren konzentratzailedun eguzki kolektore fotovoltaiko termikoei (C-PVT) buruz doa eta bi helburu nagusi ditu. Lehena Solarus-eko oraingo diseinuaren alderaketak diseinatzea da, MaReCo (Maximum Reflector Collector) diseinuaren eta parabola puruaren alderaketa batzuekin batera. Diseinu hauetan eguzki zelulen ebaketa berriak daude barruan eta 4 busbar-eko eguzki zeluletan oinarritua dago. Honi esker analisi sakon bat egin ahalko da hargailu eta estruktura diseinuak konparatuz. Bigarren helburua Solarus AB-k Gävleko unibertsitatean (HiG) kokaturik dituen kolektoreen errendimendu elektriko eta termikoa aztertzean datza. Datuak simulazio eta software espezifikoen bidez lortu dira eta ondoren Microsoft Excel®-en aztertu. Bi proiektu txikiagoak egin dira ere enpresan, bata eguzki kolektore fotovoltaiko termikoen merkatuaren ikerketan datza eta bestea eguzki kolektoreen produkzio prozesuaren gida batean. Hargailuen eta estrukturaren diseinu berriak preparatuta utzi dira prototipoen hurreneko eraikuntzarako eta proiektuarekin jarraitzeko etorkizuneko lan bat planeatu da. Unibertsitateko instalakuntzaren analisiari dagokionez, errendimendu elektriko eta termikoa estimatuena baino nabarmenki txikiagoak izan dira.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Previous work has shown that high-temperature short-term spike thermal annealing of hydrogenated amorphous silicon (a-Si:H) photovoltaic thermal (PVT) systems results in higher electrical energy output. The relationship between temperature and performance of a-Si:H PVT is not simple as high temperatures during thermal annealing improves the immediate electrical performance following an anneal, but during the anneal it creates a marked drop in electrical performance. In addition, the power generation of a-Si:H PVT depends on both the environmental conditions and the Staebler-Wronski Effect kinetics. In order to improve the performance of a-Si:H PVT systems further, this paper reports on the effect of various dispatch strategies on system electrical performance. Utilizing experimental results from thermal annealing, an annealing model simulation for a-Si:Hbased PVT was developed and applied to different cities in the U.S. to investigate potential geographic effects on the dispatch optimization of the overall electrical PVT systems performance and annual electrical yield. The results showed that spike thermal annealing once per day maximized the improved electrical energy generation. In the outdoor operating condition this ideal behavior deteriorates and optimization rules are required to be implemented.