963 resultados para Sensitivity and Specificity


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Conventional x-ray angiography frequently underestimates the true burden of atherosclerosis. Although intravascular ultrasound allows for imaging of coronary plaque, this invasive technique is inappropriate for screening or serial examinations. We therefore sought to develop a noninvasive free-breathing MR technique for coronary vessel wall imaging. We hypothesized that such an approach would allow for in vivo imaging of coronary atherosclerosis. METHODS AND RESULTS: Ten subjects, including 5 healthy adult volunteers (aged 35+/-17 years, range 19 to 56 years) and 5 patients (aged 60+/-4 years, range 56 to 66 years) with x-ray-confirmed coronary artery disease (CAD), were studied with a T2-weighted, dual-inversion, fast spin-echo MR sequence. Multiple adjacent 5-mm cross-sectional images of the proximal right coronary artery were obtained with an in-plane resolution of 0.5x1.0 mm. A right hemidiaphragmatic navigator was used to facilitate free-breathing MR acquisition. Coronary vessel wall images were readily acquired in all subjects. Both coronary vessel wall thickness (1.5+/-0.2 versus 1.0+/-0.2 mm) and wall area (21.2+/-3.1 versus 13.7+/-4.2 mm(2)) were greater in patients with CAD (both P:<0.02 versus healthy adults). CONCLUSIONS: In vivo free-breathing coronary vessel wall and plaque imaging with MR has been successfully implemented in humans. Coronary wall thickness and wall area were significantly greater in patients with angiographic CAD. The presented technique may have potential applications in patients with known or suspected atherosclerotic CAD or for serial evaluation after pharmacological intervention.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new method of measuring joint angle using a combination of accelerometers and gyroscopes is presented. The method proposes a minimal sensor configuration with one sensor module mounted on each segment. The model is based on estimating the acceleration of the joint center of rotation by placing a pair of virtual sensors on the adjacent segments at the center of rotation. In the proposed technique, joint angles are found without the need for integration, so absolute angles can be obtained which are free from any source of drift. The model considers anatomical aspects and is personalized for each subject prior to each measurement. The method was validated by measuring knee flexion-extension angles of eight subjects, walking at three different speeds, and comparing the results with a reference motion measurement system. The results are very close to those of the reference system presenting very small errors (rms = 1.3, mean = 0.2, SD = 1.1 deg) and excellent correlation coefficients (0.997). The algorithm is able to provide joint angles in real-time, and ready for use in gait analysis. Technically, the system is portable, easily mountable, and can be used for long term monitoring without hindrance to natural activities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a silicon chip-based approach for the enhanced sensitivity detection of surface-immobilized fluorescent molecules. Green fluorescent protein (GFP) is bound to the silicon substrate by a disuccinimidyl terephtalate-aminosilane immobilization procedure. The immobilized organic layers are characterized by surface analysis techniques, like ellipsometry, atomic force microscopy (AFM) and X-ray induced photoelectron spectroscopy. We obtain a 20-fold enhancement of the fluorescent signal, using constructive interference effects in a fused silica dielectric layer, deposited before immobilization onto the silicon. Our method opens perspectives to increase by an order of magnitude the fluorescent response of surface immobilized DNA- or protein-based layers for a variety of biosensor applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The sequence profile method (Gribskov M, McLachlan AD, Eisenberg D, 1987, Proc Natl Acad Sci USA 84:4355-4358) is a powerful tool to detect distant relationships between amino acid sequences. A profile is a table of position-specific scores and gap penalties, providing a generalized description of a protein motif, which can be used for sequence alignments and database searches instead of an individual sequence. A sequence profile is derived from a multiple sequence alignment. We have found 2 ways to improve the sensitivity of sequence profiles: (1) Sequence weights: Usage of individual weights for each sequence avoids bias toward closely related sequences. These weights are automatically assigned based on the distance of the sequences using a published procedure (Sibbald PR, Argos P, 1990, J Mol Biol 216:813-818). (2) Amino acid substitution table: In addition to the alignment, the construction of a profile also needs an amino acid substitution table. We have found that in some cases a new table, the BLOSUM45 table (Henikoff S, Henikoff JG, 1992, Proc Natl Acad Sci USA 89:10915-10919), is more sensitive than the original Dayhoff table or the modified Dayhoff table used in the current implementation. Profiles derived by the improved method are more sensitive and selective in a number of cases where previous methods have failed to completely separate true members from false positives.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim was to propose a strategy for finding reasonable compromises between image noise and dose as a function of patient weight. Weighted CT dose index (CTDI(w)) was measured on a multidetector-row CT unit using CTDI test objects of 16, 24 and 32 cm in diameter at 80, 100, 120 and 140 kV. These test objects were then scanned in helical mode using a wide range of tube currents and voltages with a reconstructed slice thickness of 5 mm. For each set of acquisition parameter image noise was measured and the Rose model observer was used to test two strategies for proposing a reasonable compromise between dose and low-contrast detection performance: (1) the use of a unique noise level for all test object diameters, and (2) the use of a unique dose efficacy level defined as the noise reduction per unit dose. Published data were used to define four weight classes and an acquisition protocol was proposed for each class. The protocols have been applied in clinical routine for more than one year. CTDI(vol) values of 6.7, 9.4, 15.9 and 24.5 mGy were proposed for the following weight classes: 2.5-5, 5-15, 15-30 and 30-50 kg with image noise levels in the range of 10-15 HU. The proposed method allows patient dose and image noise to be controlled in such a way that dose reduction does not impair the detection of low-contrast lesions. The proposed values correspond to high- quality images and can be reduced if only high-contrast organs are assessed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: Triggering receptor expressed on myeloid cells-1 (TREM-1) was reported to be up-regulated in various inflammatory diseases as well as in bacterial sepsis. Increased cell-surface TREM-1 expression was also shown to result in marked plasma elevation of the soluble form of this molecule (sTREM-1) in patients with bacterial infections. In this study, we investigated sTREM-1, procalcitonin and C-reactive protein in postmortem serum in a series of sepsis-related fatalities and control individuals who underwent medico-legal investigations. sTREM-1 was also measured in pericardial fluid and urine. METHODS: Two study groups were prospectively formed, a sepsis-related fatalities group and a control group. The sepsis-related fatalities group consisted of sixteen forensic autopsy cases. Eight of these had a documented clinical diagnosis of sepsis in vivo. The control group consisted of sixteen forensic autopsy cases with various causes of death. RESULTS: Postmortem serum sTREM-1 concentrations were higher in the sepsis group with a mean value of 173.6 pg/ml in septic cases and 79.2 pg/ml in control individuals. The cutoff value of 90 pg/ml provided the best sensitivity and specificity. Pericardial fluid sTREM-1 values were higher in the septic group, with a mean value of 296.7 pg/ml in septic cases and 100.9 pg/ml in control individuals. The cutoff value of 135 pg/ml provided the best sensitivity and specificity. Mean urine sTREM-1 concentration was 102.9 pg/ml in septic cases and 89.3 pg/ml in control individuals. CONCLUSIONS: Postmortem serum sTREM-1, individually considered, did not provide better sensitivity and specificity than procalcitonin in detecting sepsis. However, simultaneous assessment of procalcitonin and sTREM-1 in postmortem serum can be of help in clarifying contradictory postmortem findings. sTREM-1 determination in pericardial fluid can be an alternative to postmortem serum in those situations in which biochemical analyses are required and blood collected during autopsy proves insufficient.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE To develop a score predicting the risk of adverse events (AEs) in pediatric patients with cancer who experience fever and neutropenia (FN) and to evaluate its performance. PATIENTS AND METHODS Pediatric patients with cancer presenting with FN induced by nonmyeloablative chemotherapy were observed in a prospective multicenter study. A score predicting the risk of future AEs (ie, serious medical complication, microbiologically defined infection, radiologically confirmed pneumonia) was developed from a multivariate mixed logistic regression model. Its cross-validated predictive performance was compared with that of published risk prediction rules. Results An AE was reported in 122 (29%) of 423 FN episodes. In 57 episodes (13%), the first AE was known only after reassessment after 8 to 24 hours of inpatient management. Predicting AE at reassessment was better than prediction at presentation with FN. A differential leukocyte count did not increase the predictive performance. The score predicting future AE in 358 episodes without known AE at reassessment used the following four variables: preceding chemotherapy more intensive than acute lymphoblastic leukemia maintenance (weight = 4), hemoglobin > or = 90 g/L (weight = 5), leukocyte count less than 0.3 G/L (weight = 3), and platelet count less than 50 G/L (weight = 3). A score (sum of weights) > or = 9 predicted future AEs. The cross-validated performance of this score exceeded the performance of published risk prediction rules. At an overall sensitivity of 92%, 35% of the episodes were classified as low risk, with a specificity of 45% and a negative predictive value of 93%. CONCLUSION This score, based on four routinely accessible characteristics, accurately identifies pediatric patients with cancer with FN at risk for AEs after reassessment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To explore the discriminatory power of matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) for detecting subtle differences in isogenic isolates, we tested isogenic strains of Staphylococcus aureus differing in their expression of resistance to methicillin or teicoplanin. More important changes in MALDI-TOF MS spectra were found with strains differing in methicillin than in teicoplanin resistance. In comparison, very minor or no changes were recorded in pulsed-field gel electrophoresis profiles or peptidoglycan muropeptide digest patterns of these strains, respectively. MALDI-TOF MS might be useful to detect subtle strain-specific differences in ionizable components released from bacterial surfaces and not from their peptidoglycan network.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of the present study was to investigate the potential synergy between meropenem and levofloxacin in vitro and in experimental meningitis and to determine the effect of meropenem on levofloxacin-induced resistance in vitro. Meropenem increased the efficacy of levofloxacin against the penicillin-resistant pneumococcal strain KR4 in time-killing assays in vitro and acted synergistically against a second penicillin-resistant strain WB4. In the checkerboard, only an additive effect (FIC indices: 1.0) was observed for both strains. In cycling experiments in vitro, levofloxacin alone led to a 64-fold increase in the MIC for both strains after 12 cycles. Addition of meropenem in sub-MIC concentrations (0.25 x MIC) completely inhibited the selection of levofloxacin-resistant mutants in WB4 after 12 cycles. In KR4, the addition of meropenem led to just a twofold increase in the MIC for levofloxacin after 12 cycles. Mutations detected in the genes encoding for topoisomerase IV (parC) and gyrase (gyrA) confirmed the levofloxacin-induced resistance in both strains. Addition of meropenem was able to completely suppress levofloxacin-induced mutations in WB4 and led to only one mutation in parE in KR4. In experimental meningitis, meropenem, given in two doses (2 x 125 mg/kg), produced a good bactericidal activity (-0.45 Deltalog10 cfu/ml.h) comparable to one dose (1 x 10 mg/kg) of levofloxacin (-0.44 Deltalog10 cfu/ml.h) against the penicillin-resistant strain WB4. Meropenem combined with levofloxacin acted synergistically (-0.93 Deltalog10 cfu/ml.h), sterilizing the CSF of all rabbits.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this research was to evaluate how fingerprint analysts would incorporate information from newly developed tools into their decision making processes. Specifically, we assessed effects using the following: (1) a quality tool to aid in the assessment of the clarity of the friction ridge details, (2) a statistical tool to provide likelihood ratios representing the strength of the corresponding features between compared fingerprints, and (3) consensus information from a group of trained fingerprint experts. The measured variables for the effect on examiner performance were the accuracy and reproducibility of the conclusions against the ground truth (including the impact on error rates) and the analyst accuracy and variation for feature selection and comparison.¦The results showed that participants using the consensus information from other fingerprint experts demonstrated more consistency and accuracy in minutiae selection. They also demonstrated higher accuracy, sensitivity, and specificity in the decisions reported. The quality tool also affected minutiae selection (which, in turn, had limited influence on the reported decisions); the statistical tool did not appear to influence the reported decisions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We prospectively compared the diagnostic value of C-reactive protein (CRP) and white blood cell counts for detection of neonatal septicaemia. Sensitivity and specifity in receiver operating characteristics, and positive and negative predictive value of CRP and white blood cell count were compared in 195 critically ill preterm and term newborns clinically suspected of infection. Blood cultures were positive in 33 cases. During the first 3 days after birth CRP elevation (sensitivity 75%, specifity 86%), leukopenia (67%/90%), neutropenia (78%/80%) and immature to total neutrophil count (I/T) ratio (78%/73%) were good diagnostic parameters, as opposed to band forms with absolute count (84%/66%) or percentage (79%/71%), thrombocytopenia (65%/57%) and toxic granulations (44%/94%). Beyond 3 days of age elevated CRP (88%/87%) was the best parameter. Increased total (84%/66%) or percentage band count (79%/71%) were also useful. Leukocytosis (74%/56%), increased neutrophils (67%/65%), I/T ratio (79%/47%), thrombocytopenia (65%/57%) and toxic granulations had a low specifity. The positive predictive value of CRP was 32% before and 37% after 3 days of age, that of leukopenia was 37% in the first 3 days. CONCLUSION: During the first 3 days of life CRP, leukopenia and neutropenia were comparably good tests while after 3 days of life CRP was the best single test in early detection of neonatal septicaemia. Serial CRP estimations confirm the diagnosis, monitor the course of infection and the efficacy of antibiotic treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To compare the diagnostic performance of multi-detector CT arthrography (CTA) and 1.5-T MR arthrography (MRA) in detecting hyaline cartilage lesions of the shoulder, with arthroscopic correlation. PATIENTS AND METHODS: CTA and MRA prospectively obtained in 56 consecutive patients following the same arthrographic procedure were independently evaluated for glenohumeral cartilage lesions (modified Outerbridge grade ≥2 and grade 4) by two musculoskeletal radiologists. The cartilage surface was divided in 18 anatomical areas. Arthroscopy was taken as the reference standard. Diagnostic performance of CTA and MRA was compared using ROC analysis. Interobserver and intraobserver agreement was determined by κ statistics. RESULTS: Sensitivity and specificity of CTA varied from 46.4 to 82.4 % and from 89.0 to 95.9 % respectively; sensitivity and specificity of MRA varied from 31.9 to 66.2 % and from 91.1 to 97.5 % respectively. Diagnostic performance of CTA was statistically significantly better than MRA for both readers (all p ≤ 0.04). Interobserver agreement for the evaluation of cartilage lesions was substantial with CTA (κ = 0.63) and moderate with MRA (κ = 0.54). Intraobserver agreement was almost perfect with both CTA (κ = 0.94-0.95) and MRA (κ = 0.83-0.87). CONCLUSION: The diagnostic performance of CTA and MRA for the detection of glenohumeral cartilage lesions is moderate, although statistically significantly better with CTA. KEY POINTS: ? CTA has moderate diagnostic performance for detecting glenohumeral cartilage substance loss. ? MRA has moderate diagnostic performance for detecting glenohumeral cartilage substance loss. ? CTA is more accurate than MRA for detecting cartilage substance loss.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Blood doping involves the use of products that enhance the uptake, transport, or delivery of oxygen to the blood. One approach uses artificial oxygen carriers, known as hemoglobin-based oxygen carriers (HBOCs). This study describes an analytical strategy based on CE for detecting intact HBOCs in plasma samples collected for doping control. On-capillary detection was performed by UV/Vis at 415 nm, which offered detection selectivity for hemoproteins (such as hemoglobin and HBOCs). On-line ESI-MS detection with a TOF analyzer was further used to provide accurate masses on CE peaks and to confirm the presence of HBOCs. An immunodepletion sample preparation step was mandatory prior to analysis, in order to remove most abundant proteins that interfered with CE separation and altered the ESI process. This analytical method was successfully applied to plasma samples enriched with Oxyglobin, a commercially available HBOC used for veterinary purposes. Detection limits of 0.20 and 0.45 g/dL were achieved in plasma for CE-UV/Vis at 415 nm and CE-ESI-TOF/MS, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To determine the lower limit of dose reduction with hybrid and fully iterative reconstruction algorithms in detection of endoleaks and in-stent thrombus of thoracic aorta with computed tomographic (CT) angiography by applying protocols with different tube energies and automated tube current modulation. MATERIALS AND METHODS: The calcification insert of an anthropomorphic cardiac phantom was replaced with an aortic aneurysm model containing a stent, simulated endoleaks, and an intraluminal thrombus. CT was performed at tube energies of 120, 100, and 80 kVp with incrementally increasing noise indexes (NIs) of 16, 25, 34, 43, 52, 61, and 70 and a 2.5-mm section thickness. NI directly controls radiation exposure; a higher NI allows for greater image noise and decreases radiation. Images were reconstructed with filtered back projection (FBP) and hybrid and fully iterative algorithms. Five radiologists independently analyzed lesion conspicuity to assess sensitivity and specificity. Mean attenuation (in Hounsfield units) and standard deviation were measured in the aorta to calculate signal-to-noise ratio (SNR). Attenuation and SNR of different protocols and algorithms were analyzed with analysis of variance or Welch test depending on data distribution. RESULTS: Both sensitivity and specificity were 100% for simulated lesions on images with 2.5-mm section thickness and an NI of 25 (3.45 mGy), 34 (1.83 mGy), or 43 (1.16 mGy) at 120 kVp; an NI of 34 (1.98 mGy), 43 (1.23 mGy), or 61 (0.61 mGy) at 100 kVp; and an NI of 43 (1.46 mGy) or 70 (0.54 mGy) at 80 kVp. SNR values showed similar results. With the fully iterative algorithm, mean attenuation of the aorta decreased significantly in reduced-dose protocols in comparison with control protocols at 100 kVp (311 HU at 16 NI vs 290 HU at 70 NI, P ≤ .0011) and 80 kVp (400 HU at 16 NI vs 369 HU at 70 NI, P ≤ .0007). CONCLUSION: Endoleaks and in-stent thrombus of thoracic aorta were detectable to 1.46 mGy (80 kVp) with FBP, 1.23 mGy (100 kVp) with the hybrid algorithm, and 0.54 mGy (80 kVp) with the fully iterative algorithm.