941 resultados para Ruthenium(II) complexes


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A series of (alpha-diimine)nickel(II) complexes [ArN = C(Nap)C = NAr]NiBr2 (Nap = 1,8-naphthdiyl, Ar = 2,6-Me2C6H3, 3a; Ar = 2,4,6-Me3C6H2 3b; Ar = 2,6-Me-2-4-tBuC(6)H(2), 3c; Ar 2,6-Me-2-4-BrC6H2, 3d; Ar = 2,6-Me-2-4-ClC6H2, 3e; Ar 2,6-iPr(2)C(6)H(3), 3f; Ar = 2,4,6-iPr(3)C(6)H(2), 3g; Ar = 2,6-iPr-4-BrC6H2, 3h) have been synthesized, characterized, and investigated as precatalysts for ethylene polymerization in the presence of modified methylaluminoxane (MMAO).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel Ruthenium(II) tris(bipyridine)-based solid-state electrochemiluminescence (ECL) sensor was developed in this paper. The sensor was fabricated by immobilising tris(2,2'-bipyridyl) ruthenium(II) (Ru(bpy)(3)(2+)) in sulfonic-functionalised porous titania (TiO2-SO3H) nanoparticles via an ion exchange strategy, followed by employing environment friendly and stable biopolymer chitosan (CHIT) to entrap Ru(bpy)(3)(2+)/TiO2-SO3H onto the ITO electrode.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

CE with tris(2,2'-bipyridyl) ruthenium(II) (Ru(bpy)(3)(2+)) electrochemiluminescence (ECL) detection for the quantitative determination of isocyanates was first reported. Hexamethylene diisocyanate (HDI) and hexyl isocyanate (HI) were used as the model analytes. Commercially available N,N-diethyl-N'-methylethylenediamine was used as the derivatization reagent. It has both a secondary amine group and a tertiary amine group. The secondary amine group can quantitatively react with isocyanate group, and the tertiary amine group can react with Ru(bpy)(3)(2+) to produce strong ECL signal for sensitive detection. The derivatization reaction was almost instantaneous and is much faster than other reported derivative reactions using other derivative reagents.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An electrochemiluminescence (ECL) sensor based on Ru(bpy)(3)(2+)-graphene-Nafion composite film was developed. The graphene sheet was produced by chemical conversion of graphite, and was characterized by atomic force microscopy (AFM), scanning electron microscopy (SEM), and Raman spectroscopy. The introduction of conductive graphene into Nafion not only greatly facilitates the electron transfer of Ru(bpy)(3)(2+), but also dramatically improves the long-term stability of the sensor by inhibiting the migration of Ru(bpy)(3)(2+) into the electrochemically inactive hydrophobic region of Nafion. The ECL sensor gives a good linear range over 1 x 10(-7) to 1 x 10(-4) M with a detection limit of 50 nM towards the determination of tripropylamine (TPA), comparable to that obtained by Nafion-CNT.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ECL of several amines containing different numbers of hydroxyl and amino groups was investigated. N-butyldiethanolamine is found to be more effective than 2-(dibutylamino)ethanol at gold and platinum electrodes, and is the most effective coreactant reported until now. Surprisingly, ECL intensities of monoamines, such as 2-(dibutylamino)ethanol and N-butyldiethanolamine, are much stronger than that of diamines including N,N,N',N'-tetrakis-(2-hydroxyethyl)-ethylenediamine and N,N,N',N'-tetrakis-(2-hydroxypropyl)ethlenediamine. The striking contrast between ECL signals of the investigated monoamines and diamines may result from more significant side reactions of diamines, such as the intramolecular side reactions between oxidative amine cation radicals and reductive amine free radicals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel tris(2,2'-bipyridine)ruthenium(II) (Ru(bpy)3(2+)) cathodic electrochemiluminescence (ECL) was generated at -0.78V at the Pt electrode in acetonitrile (ACN), which suggested that the cathodic ECL differed from conventional cathodic ECL It was found that tripropylamine (TPrA) could enhance this cathodic ECL and the linear range (log-log plot) was 0.2 mu M-0.2 mM. In addition, hydrogen peroxide (H2O2) could inhibit the cathodic ECL and was indirectly detected with the linear range of 27-540 mu M. The RSD (n = 12) of the ECL intensity in the presence of 135 mu M H2O2 was 0.87%. This method was also demonstrated for the fast determination of H2O2 in disinfectant sample and satisfactory results were obtained.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The rational design, synthesis and characterization of five phosphorescent platinum complexes [(C boolean AND N) Pt(acac)] [Hacac = acetylacetone, HC boolean AND N = 1-methyl-2-(4-fluorophenyl)benzoimidazole (H-FMBI), 1-methyl-2-phenylbenzoimidazole (H-MBI), 1,2-diphenyl-benzoimidazole (H-PBI), 1-(4-(3,6-di-t-butylcarbazol-9-yl)) phenyl-2-phenylbenzoimidazole (t-BuCz-H-PBI), and 1-(4-(3,6-di-(3,6-di-t-butyl-carbazol-9-yl))carbazol-9-yl) phenyl-2-phenylbenzoimidazole (t-BuCzCz-H-PBI)] have been discussed. The crystal structure of (MBI) Pt(acac) shows a nearly ideal square planar geometry around Pt atom and the weak intermolecular interactions with pi-pi spacing of 3.55 angstrom. All of the complexes emit green phosphorescence from the metal-to-ligand charge-transfer (MLCT) excited state with high quantum efficiency (0.08-0.17) at room temperature.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Four cyclometalated Pt(II) complexes, i.e., [(L-2)PtCl] (1b), [(L-3)PtCl] (1c), [(L-2)PtC CC6H5] (2b) and [(L-3)PtC CC6H5] (2c) (HL2 = 4-[p-(N-butyl-N-phenyl)anilino]-6-phenyl-2,2'-bipyridine and HL3 = 4-[p(-N,N'-dibutyl-N'-phenyl)phenylene-diamino]-phenyl-6-phenyl-2,2'-bipyridine), have been synthesized and verified by H-1 NMR, C-13 NMR and X-ray crystallography. Unlike previously reported complexes [(L-1)PtCl] (1a) and [(L-1)PtC CC6H5] (2a) (HL1 = 4,6-diphenyl-2,2'-bipyridine), intense and continuous absorption bands in the region of 300-500 nm with strong metal-to-ligand charge transfer ((MLCT)-M-1) (d pi(Pt) -> pi*(L)) transitions (epsilon similar to 2 x 10(4) dm(3) mol (1) cm (1)) at 449-467 nm were observed in the UV-Vis absorption spectra of complexes 1b, 1c, 2b and 2c.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Label free electrochemiluminescence (ECL) DNA detection based on catalytic guanine and adenine bases oxidation using tris(2,2'-bipyridyl)ruthenium(II) [Ru(bpy)(3)(2+)] modified glassy carbon (GC) electrode was demonstrated in this work. The modified GC electrode was prepared by casting carbon nanotubes (CNT)/Nafion/Ru(bpy)(3)(2+) composite film on the electrode surface. ECL signals of doublestranded DNA and their thermally denatured counterparts can be distinctly discriminated using cyclic voltammetry (CV) with a low concentration (3.04 x 10(-8) mol/L for Salmon Testes-DNA). Most importantly, sensitive single-base mismatch detection of p53 gene sequence segment was realized with 3.93 x 10(-10) mol/L employing CV stimulation (ECL signal of C/A mismatched DNA oligonucleotides was 1.5-fold higher than that of fully base-paired DNA oligonucleotides). Label free, high sensitivity and simplicity for single-base mismatch discrimination were the main advantages of the present ECL technique for DNA detection over the traditional DNA sensors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The electrochemiluminescence (ECL) of tris(2,29-bipyridyl) ruthenium(II) [Ru(bpy)(3)(2+)] ion-exchanged in the sulfonic-functionalized MCM-41 silicas was developed with tripropylamine (TPrA) as a co-reactant in a carbon paste electrode (CPE) using a room temperature ionic liquid (IL) as a binder. The sulfonic-functionalized silicas MCM-41 were used for preparing an ECL sensor by the electrostatic interactions between Ru( bpy)(3)(2+) cations and sulfonic acid groups. We used the IL as a binder to construct the CPE (IL-CPE) to replace the traditional binder of the CPE (T-CPE)-silicone oil. The results indicated that the MCM-41-modified IL-CPE had more open structures to allow faster diffusion of Ru( bpy)(3)(2+) and that the ionic liquid also acted as a conducting bridge to connect TPrA with Ru( bpy)(3)(2+) sites immobilized in the electrode, resulting in a higher ECL intensity compared with the MCM-41-modified T-CPE. Herein, the detection limit for TPrA of the MCM-41-modified IL-CPE was 7.2 nM, which was two orders of magnitude lower than that observed at the T-CPE. When this new sensor was used in flow injection analysis (FIA), the MCM-41-modified IL-CPE ECL sensor also showed good reproducibility. Furthermore, the sensor could also be renewed easily by mechanical polishing whenever needed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An enhanced electrochemiluminescence (ECL) efficiency is obtained from the ruthenium complex tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy)(3)(2+)) by introduction of an ionic liquid (IL) 1-butyl-3-methylimidazolium tetrafluoroborate (BMImBF(4)). Upon addition of 1% (v/v) BMImBF(4) to 0.1 mm Ru(bpy)(3)(2+) solution, a maximum increase in ECL intensity is obtained both at an indium tin oxide (ITO) electrode (15-fold) and at a glassy carbon (GC) electrode (5- to 64old). Furthermore, upon addition of 1% (v/v) BMImBF4 to 5 pm Ru(bpy)(3)(2+)/100 mm co-reactant systems at a GC electrode, IL adsorption occurs at the electrode surface, which results in a change of the polarity of the electrode surface. Such functionalization greatly improves the functions of both Ru(bpy)(3)(2+) and ionic liquids, as is demonstrated in the sensitive and selective concentration enrichment of the Ru(bpy)(3)(2+) co-reactants.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper. we demonstrate an clectrochemiluminescence (ECL) enhancement of tris(2,2-bipyridyl)rutheniuin(II) (Ru(bpy)(3)(2+)) by the addition of silver(l) ions. The maximum enhancement factor of about 5 was obtained on a glassy carbon electrode in the absence of co-reactant. The enhancement of ECL intensity was possibly attributed to the unique catalytic activity of Ag+ for reactions between Ru(bpy)(3)(3+) with OR The higher enhancement was observed in phosphate buffer solutions compared with that from borate buffer solutions. This resulted from the fact that formation of nanoparticles with large surface area in the phosphate buffer solution exhibited high catalytic activity. The amount of Ag+, solution pH and working electrode materials played important roles for the ECL enhancement. We also studied the effects of Ag+ on Ru(bpy)(3)(2+)/tripropylamine and Ru(bpy)(3)(2+)/C2O42- ECL systems.