951 resultados para Reproducibility
Resumo:
This study vas aimed to validate the American Speech-Language-Hearing Association Functional Assessment Of Communication Skills (ASHA FACS) for a Brazilian population. The scale was translated and adapted into Portuguese. Thirty-two patients with mild Alzheimer disease (AD). 25 patients with moderate AD. and 51 elderly without dementia were examined with Mini Mental State Examination, Geriatric Depression Scale. and Alzheimer Disease Assessment Scale-Cognitive subscale (ADAS-cog). The ASHA FACS was answered by their relative/caregiver. The scale`s internal consistency. its inter-examiner and intra-examiner`s reproducibility. and scale`s criterion validity were researched by correlation with ADAS-cog,. The sensitivity and specificity Were also researched. Statistical analyses indicated that the ASHA FACS has excellent internal consistency (Cronbach alpha = 0.955), test-retest reliability (interclass correlation coefficient = 0.995; P < 0.001). and inter-examiners (interclass correlation coefficient = 0.998: P < 0.001). It showed excellent criterion validity when correlated with ADAS-cog,. The ASHA FACS scale showed good sensitivity (75.0%) and specificity (82.4%) values once it is an ecologic and broad evaluation. The ASHA FACS Portuguese version is a valid and reliable instrument to verify communication alterations in AD patients and fills an important gap of efficiency indicators for speech language therapy in our country.
Resumo:
Background. The mechanical alterations related to the overload of respiratory muscles observed in adults with persistent asthma might lead to the development of chronic alterations in posture, musculoskeletal dysfunction and pain; however, these changes remain poorly understood. Objective. This study aimed to assess postural alignment, muscle shortening and chronic pain in adults with persistent asthma. Methods. This cross-sectional and controlled study enrolled 30 patients with mild (n = 17) and severe ( n = 13) persistent asthma. Fifteen non-asthmatic volunteers were also assessed. Asthma was classified by the Global Initiative for Asthma (GINA) guidelines. Postural alignment and muscle shortening were evaluated by head and shoulder positions, chest wall mobility, and posterior ( trunk and lower limb) muscle flexibility. In addition, the measures used were previously tested for their reproducibility. Pain complaints were also assessed. Results. In comparison with non-asthmatic subjects, patients with mild or severe persistent asthma held their head and shoulders more forward and had lower chest wall expansion, decreased shoulder internal rotation, and decreased thoracic spine flexibility. Chronic lower thoracic, cervical, and shoulder pain was significantly increased in patients with mild or severe asthma compared with non-asthmatic subjects (p < 0.05). Conclusion. Adults with persistent asthma have musculoskeletal dysfunction and chronic pain that is independent of the severity of their disease but that might be related to their age at the onset of disease symptoms.
Resumo:
The authors developed an evaluation scale for sit-stand from the ground for children with Duchenne muscular dystrophy (DMD) and tested its reliability. The construction occurred in stages: (a) the characterization of the movement in healthy children, (b) the characterization of the movement in children with DMD, (c) the elaboration of the 1st version of the scale and the manual, (d) the evaluation by experts and readjustments, and (e) the analysis of inter- and intraexaminer reliability and correlation with the Vignos Scale, age, and time for the execution of the activity. The scale comprehended 3 phases for sitting and 5 for the standing. A very good repeatability of the measures of sitting and standing (ICC = 0.89 and 0.84, respectively) and excellent reproducibility (ICC = 0.93 and 0.92, respectively) was demonstrated. The Kappa coefficient for the 8 phases in the interexaminer analysis varied from 0.77 to 1.00 (excellent reliability), and in the intraexaminer analysis varied from 0.80 to 1.00 (excellent reliability). Good correlation was found between the variables on the Vignos Scale (age: r = 0.58; stand: r = 0.56). The scale is a reliability instrument that allows evaluation of the activity of sitting and standing in children with DMD.
Resumo:
The Douleur Neuropathique 4 (DN4) questionnaire was developed by the French Neuropathic Pain Group and is a simple and objective tool, with the ability to distinguish nociceptive from neuropathic pain. The purpose of this work was to validate the DN4 questionnaire in the Portuguese language in order to allow its use in clinical and research settings. A double-blind, accuracy study was conducted, consisting of translation, back-translation, literal evaluation, semantic equivalence, and communication with the target population. The Portuguese version of the questionnaire was applied in a sample of 101 patients with neuropathic (N = 42) or nociceptive pain (N = 59), ranked according to medical diagnosis. The reproducibility, reliability and validity of the instrument were analyzed, and showed a high diagnostic power for this version of the DN4 questionnaire. The Portuguese version of the DN4 questionnaire presented good validity and reliability, allowing it to identify neuropathic pain and neuropathic characteristics of mixed pain syndromes. Perspective: This article presents the first validated neuropathic pain questionnaire in the Portuguese language and represents a useful tool in the assessment of neuropathic pain both in the clinical setting and in population-based studies. The sensible and quick format of this instrument are key factors that will contribute to its widespread use, permitting a true recognition of patients with neuropathic pain. (C) 2010 by the American Pain Society
Resumo:
To validate the Brazilian version of the Brief Pain Inventory (BPI-B) scale and to determine the optimal cutpoints for mild, moderate, and severe pain based on patients` rating of their worst pain. One hundred forty-three outpatients with cancer were recruited in Hospital das Clinicas-University of Sao Paulo, Brazil. Confirmatory factor analysis confirmed two underlying dimensions, pain severity, and pain interference, with Cronbach`s alpha of 0.91 and 0.87, respectively. Convergent validity was shown by the correlation observed between the BPI dimensions with the EORTC-QLQ-C30 pain scale and the McGill Pain Questionnaire. The BPI-B detected significant differences in the two dimensions by disease and performance status, supporting known-group validity. For the worst pain, the optimal cutpoints were 4 and 7 (1-4 = mild pain, 5-7 = moderate, and 8-10 = severe). Our data show that BPI-B is a brief, useful, and valid tool for assessing pain and its impact on patient`s life.
Resumo:
To evaluate the correlation between intraocular pressure (IOP) rise, ocular pulse amplitude (OPA), and choroidal thickness (ChT) during the water drinking test (WDT). Primary open-angle glaucoma (POAG) patients were submitted to the WDT followed by serial IOP measurements using dynamic contour tonometry (DCT), Goldman tonometry (GAT), and ChT measurements using ultrasonographic A and B-scan (USG). A control group not submitted to the test was also evaluated using DCT, GAT, and USG. Intraclass correlation coefficient (ICC) was calculated in the control group in order to assess the reproducibility of measurements. Spearman`s coefficient (rho) was used to assess the correlation between the variables. Thirty eyes were included in the study. There was a significant IOP rise during the WDT using both GAT and DCT (p < 0.001). The OPA and ChT measurements also increased significantly (p < 0.001). Spearman`s correlation between the OPA values and ChT measurements was significant and moderate (rho = 0.40, p = 0.005). The average increase of OPA and ChT measurements occurred 15 min before the IOP rise. There was a significant increase of OPA and ChT measurements followed by an IOP rise during the WDT. Increased choroidal volume due to hemodynamic forces may be enrolled in the mechanism of IOP elevation during this stress test.
Resumo:
PURPOSE: To compare the ability of Fourier-domain (FD) optical coherence tomography (3D OCT-1000; Top, con, Tokyo, Japan) and time domain (TD) OCT (Stratus; Carl Zeiss Meditec Inc, Dublin, California, USA) to detect axonal loss in eyes with band atrophy (BA) of the optic nerve. DESIGN: Cross-sectional study. METHODS: Thirty-six eyes from 36 patients with BA and temporal visual field (VF) defect from chiasmal compression and 36 normal eyes were studied. Subjects were submitted to standard automated perimetry and macular and retinal nerve fiber layer (RNFL) measurements were taken using 3D OCT-1000 and Stratus OCT. Receiver operating characteristic (ROC) curves were calculated for each parameter. Spearman correlation coefficients were obtained to evaluate the relationship between RNFL and macular thickness parameters and severity of VF loss. Measurements from the two devices were compared. RESULTS: Regardless of OCT device, all RNFL and macular thickness parameters were significantly lower in eyes with BA compared with normal eyes, but no statistically significant difference was found with regard to the area under the ROC curve. Structure-function relationships were also similar for the two devices. In both groups, RNFL and macular thickness measurements were generally and in some cases significantly smaller with 3D OCT-1000 than with Stratus OCT. CONCLUSIONS: The introduction of FD technology did not lead to better discrimination ability for detecting BA of the optic nerve compared with TD technology when using the software currently provided by the manufacturer. 3D OCT-1000 FD OCT RNFL and macular measurements were generally smaller than TD Stratus OCT measurements. Investigators should be aware of this fact when comparing measurements obtained with these two devices. (Am J Oplathalmol 2009;147: 56-63. (c) 2009 by Elsevier Inc. All rights reserved.)
Resumo:
Introduction: This study evaluated the interobserver reliability of plain radiograpy versus computed tomography (CT) for the Universal and AO classification systems for distal radius fractures. Patients and methods: Five observers classified 21 sets of distal radius fractures using plain radiographs and CT independently. Kappa statistics were used to establish a relative level of agreement between observers for both readings. Results: Interobserver agreement was rated as moderate for the Universal classification and poor for the AO classification. Reducing the AO system to 9 categories and to its three main types reliability was raised to a ""moderate"" level. No difference was found for interobserver reliability between the Universal classification using plain radiographs and the Universal classification using computed tomography. Interobserver reliability of the AO classification system using plain radiographs was significantly higher than the interobserver reliability of the AO classification system using only computed tomography. Conclusion: From these data, we conclude that classification of distal radius fractures using CT scanning without plain radiographs is not beneficial.
Resumo:
Contents Sex pre-selection of bovine offsprings has commercial relevance for cattle breeders and several methods have been used for embryo sex determination. Polymerase chain reaction (PCR) has proven to be a reliable procedure for accomplishing embryo sexing. To date, most of the PCR-specific primers are derived from the few single-copy Y-chromosome-specific gene sequences already identified in bovines. Their detection demands higher amounts of embryonic genomic material or a nested amplification reaction. In order to circumvent this, limitation we searched for new male-specific sequences potentially useful in embryo sexing using random amplified polymorphic DNA (RAPD) analysis. Random amplified polymorphic DNA (RAPD) assay reproducibility problems can be overcome by its conversion into Sequence Characterized Amplified Region (SCAR) markers. In this work, we describe the identification of two bovine male-specific markers (OPC16(323) and OPF10(1168)) by means of RAPD. These markers were successfully converted into SCARs (OPC16(726) and OPF10(984)) using two pairs of specific primers.Furthermore, inverse PCR (iPCR) methodology was successfully applied to elongate OPC16(323) marker in 159% (from 323 to 837 bp). Both markers are shown to be highly conserved (similarity >= 95%) among bovine zebu and taurine cattle; OPC16(323) is also highly similar to a bubaline Y-chromosome-specific sequence. The primers derived from the two Y-chromosome-specific conserved sequences described in this article showed 100% accuracy when used for identifying male and female bovine genomic DNA, thereby proving their potential usefulness for bovine embryo sexing.
Resumo:
Background and Aims. HTLV-I-transformed T cells secrete biologically active forms of vascular endothelial growth factor (VEGF) and basic fibroblast growth factor (b-FGF). In addition, HTLV-I-transformed cells have a high capacity of adhesion to endothelial cells. Methods. We measured the circulating endothelial progenitor cells (EPCs) and mature endothelial cells (MECs) by flow cytometry in 27 HTLV-I carriers in comparison to 30 healthy, age- and gender-matched subjects. All subjects had HTLV-I positivity confirmed by Western blot and/or polymerase chain reaction (PCR). The numbers of different subpopulations of EPCs and MECSs were evaluated by four-color flow cytometry using a panel of monoclonal antibodies. All reactions were done in duplicate to confirm reproducibility of the results. Results. The median age of all 27 HTLV-I carriers enrolled in this study was 45 years (range: 27-65 years); 11(41%) were male and 16 (59%) were female. The median age of the 30 healthy subjects in the control group was 45.5 years (range: 20-63 years); 11 (36.6%) were male and 19 (63.4%) were female. The number of EPCs was significantly higher in HTLV-I carriers (median 0.8288 cells/mu L, range: 0.0920-3.3176 cells/mu L) as compared to control group (median 0.4905 cells/mu L, range: 0.0000-1.5660 cells/mu L) (p = 0.035). In contrast, the median of the MECs in the HTLV-I carriers was 0.6380 cells/mu L (range: 0.0473-5.7618 cells/mu L) and 0.4950 cells/mu L (range: 0.0000-4.0896 cells/mu L) in the control group, with no statistical difference (p = 0.697). Conclusions. We demonstrated that EPCs, but not MECs, are increased in the peripheral blood of HTLV-I carriers. (C) 2011 IMSS. Published by Elsevier Inc.
Resumo:
Dacryocystorhinostomy is the treatment of choice for the obstruction of the lachrymal apparatus. At the end of last century, the development of the endoscopic instruments for nasosinusal surgery has made it possible to do it through the endoscopic pathway. Nonetheless, anatomical variations make it difficult to have reproducibility endonasaly. Aim: study the endoscopic anatomy of the lachrymal fossa through transillumination of the common canaliculus. Study design: experimental. Materials and Methods: we dissected 40 lachrymal pathways from 20 human cadavers, in three stages: 1. identification and dilation of the lachrymal canaliculus. 2 Optic fiber beam introduction; 3 - endoscopic dissection of the lachrymal sac, describing its position. Results: the most frequent position of the lachrymal sac was between the free border of the middle turbinate and its insertion immediately underneath it. The maxillary line was seen in 95% of the cases. Septoplasty was needed in 12.5%, unicifectomy in 35% and middle turbinectomy in 7.5%. Conclusion: Although the lachrymal sac has a more frequent location, its position varied considerably. The transillumination of the common canaliculus proved useful, solving the problem of the anatomical variability.
Resumo:
The aim was to investigate inter-tester and intra-tester reliability and parallel reliability between a visual assessment method and a method using a pachymeter for locating the mid-point of the patella in determining the medial/lateral patella orientation. Fifteen asymptomatic subjects were assessed and the mid-point of the patella was determined by both methods on two separate occasions two weeks apart. Inter-tester reliability was obtained by ANOVA and by intraclass correlation coefficient (ICC); intra-tester reliability was obtained by a paired t-test and ICC; and parallel reliability was obtained by Pearson`s Correlation and ICC, for the measurement on the first and second evaluations. There was acceptable inter-tester agreement (p = 0.490) and reliability for the visual inspection (ICC = 0.747) and for the pachymeter (ICC = 0.716) at the second evaluation. The inter-tester reliability in the first evaluation was unacceptable (visual ICC = 0.604; pachymeter ICC = 0.612). Although there was statistical similarity between measurements for the first and second evaluations for all testers, intra-tester reliability was not acceptable for both methods: visual (examiner 1 ICC = 0.175; examiner 2 ICC = 0.189; examiner 3 ICC = 0.155) and pachymeter (examiner 1 ICC = 0.214; examiner 2 ICC = 0.246; examiner 3 ICC = 0.069). Parallel reliability gave a perfect correlation at the first evaluation (r=0.828; p<0.001) and at the second (r=0.756; p<0.001) and reliability was between acceptable and very good (ICC = [0.748-0.813]). Both visual and pachymeter methods provide reliable and similar medial/lateral patella orientation and are reliable between different examiners, but the results between the two assessments at 2 weeks` interval demonstrated an unacceptable reliability. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Objective: The purpose of this study was to investigate the reliability and validity of photogrammetry in measuring the lateral spinal inclination angles. Methods: Forty subjects (32 female and 8 males) with a mean age of 23.4 +/- 11.2 years had their scoliosis evaluated by radiographs of their trunk, determined by the Cobb angle method, and by photogrammetry. The statistical methods used included Cronbach alpha, Pearson/Spearman correlation coefficients, and regression analyses. Results: The Cronbach a values showed that the photogrammetric measures showed high internal consistency, which indicated that the sample was bias free. The radiograph method showed to be more precise with intrarater reliabilities of 0.936, 0.975, and 0.945 for the thoracic, lumbar, and thoracolumbar curves, respectively, and interrater reliabilities of 0.942 and 0.879 for the angular measures of the thoracic and thoracolumbar segments, respectively. The regression analyses revealed a high determination coefficient although limited to the adjusted linear model between the radiographic and photographic measures. It was found that with more severe scoliosis, the lateral curve measures obtained with the photogrammetry were for the thoracic and lumbar regions (R = 0.619 and 0.551). Conclusions: The photogrammetric measures were found to be reproducible in this study and could be used as Supplementary information to decrease the number of radiographs necessary for the monitoring of scoliosis. (J Manipulative Physiol Ther 2009;32:423-430)
Resumo:
Blood pressure (BP) measurement is the basis for the diagnosis and management of arterial hypertension. The aim of this study was to compare BP measurements performed in the office and at home (home blood pressure monitoring, HBPM) in children and adolescents with chronic arterial hypertension. HBPM was performed by the patient or by his/her legal guardian. During a 14-day period, three BP measurements were performed in the morning or in the afternoon (daytime measurement) and in the evening (night-time measurement), with 1-min intervals between measurements, totalling six measurements per day. HBPM was defined for systolic blood pressure (SBP) and diastolic blood pressure (DBP) values. HBPM was evaluated in 40 patients (26 boys), mean age of 12.1 years (4-18 years). SBP and DBP records were analysed. The mean differences between average HBP and doctor`s office BP were 0.6 +/- 14 and 4 +/- 13 mm Hg for SBP and DBP, respectively. Average systolic HBPM (daytime and night-time) did not differ from average office BP, and diastolic HBPM (daytime and night-time) was statistically lower than office BP. The comparison of individual BP measurements along the study period (13 days) by s.d. of differences shows a significant decline only for DBP values from day 5, on which difference tends to disappear towards the end of the study. Mean daytime and night-time SBP and DBP values remained stable throughout the study period, confirming HBPM as an acceptable methodology for BP evaluation in hypertensive children and adolescents. Journal of Human Hypertension (2009) 23, 464-469; doi:10.1038/jhh.2008.167; published online 12 March 2009
Resumo:
The Sciatic Functional Index (SFI) is a quite useful tool for the evaluation of functional recovery of the sciatic nerve of rats in a number of experimental injuries and treatments. Although it is an objective method, it depends on the examiner`s ability to adequately recognize and mark the previously established footprint key points, which is an entirely subjective step, thus potentially interfering with the calculations according to the mathematical formulae proposed by different authors. Thus, an interpersonal evaluation of the reproducibility of an SFI computer-aided method was carried out here to study data variability. A severe crush injury was produced on a 5 mm-long segment of the right sciatic nerve of 20 Wistar rats (a 5000 g load directly applied for 10 min) and the SH was measured by four different examiners (an experienced one and three newcomers) preoperatively and at weekly intervals from the 1st to the 8th postoperative week. Three measurements were made for each print and the average was calculated and used for statistical analysis. The results showed that interpersonal correlation was high (0.82) in the 3rd, 4th, 5th, 7th and 8th weeks, with an unexpected but significant (p < 0.01) drop in the 6th week. There was virtually no interpersonal correlation (correlation index close to 0) on the 1st and 2nd weeks, a period during which the variability between animals and examiners (p =0.24 and 0.32, respectively) was similar, certainly due to a poor definition of the footprints. The authors conclude that the SFI method studied here is only reliable from the 3rd week on after a severe lesion of the sciatic nerve of rats. (C) 2008 Elsevier B.V. All rights reserved.